LED Power
AQF60C SERIES
60 Watts
KEY FEATURES
 Open Frame LED Power Supply
 Universal Input: 90-305 VAC
 <0.5W No Load Input Power
 Bulit-in Active PFC Function
 Free Air Convection
 High Reliability
 With Constant Current & Constant Voltage
 LED Power Application
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
AQF60C-24S
Max Output Wattage (W)
Voltage
60W
Input
Output
Protection
Isolation
Physical
Safety
AQF60C-54S
90-305 VAC or 127-430 VDC
47-63 Hz
Current (Full load)
0.64 A max. (115 VAC) / 0.32 A max. (230 VAC) / 0.3 A max. (277 VAC)
Inrush Current (<2ms) (Cold Start)
40 A max. (115 VAC) / 70 A max. (230 VAC)
Leakage Current
<0.75 mA max.
Power Factor
PF>0.97 (115 VAC) / PF>0.9 (230 VAC) at Full Load
Voltage (V.DC.)
24V
36V
48V
54V
Constant Current Range (V.DC.)
15.5 ~ 24V
21.6 ~ 36V
28.8 ~ 48V
32.4 ~ 54V
Voltage Accuracy
±2%
Current Accuracy
±10%
Current (Convection) (mA) max
2500
1666
1250
1111
Current ADJ Range (mA)
Voltage ADJ Range (V.DC.)
(10-100% Load)
Line Regulation (10-100%)
1500 ~ 2500
999 ~ 1666
750 ~ 1250
666 ~ 1111
23.5 ~ 26V
34.5 ~ 37.5V
46 ~ 48.5V
53 ~ 55.5V
±1%
Load Regulation (10-100%)
±1%
Ripple & Noise (max.)
200mVp-p
Efficiency (typ.)
88%
Hold-up Time
25 ms min.
Over Power Protection
Auto recovery, 105 ~ 160% rated output power
Over Voltage Protection(for C.C Mode)
Auto recovery
Short Circuit Protection
Auto recovery
Input-Output (V.AC)
3750V
Input-FG
(V.AC)
1880V
Output-FG
.(V.AC)
250mVp-p
89%
89%
500V
-40°C…+85°C
Temperature Coefficient
±0.02%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>100,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.
Dimension (L x W x H)
4.17 x 2.04 x 1.06 Inches
Weight
200 g ±15%
Cooling Method
Free air convection
Agency Approvals
UL8750、IEC / EN 61347-2-13、 IEC / EN 61347-1
EMI
EN 55015、Class B
EMS (Noise Immunity)
EN 61547
Surge
2KV L-L, 4KV L-E
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
89%
-40°C…+70°C (with derating)
Storage Temperature
(Conducted & Radiated Emission)
EMC
AQF60C-48S
Frequency (Hz)
Operating Temperature
Environment
AQF60C-36S
( 106.0 x 52.0 x 27.0 mm ) Tolerance 0.5 mm
-1-
VER : A_3
update : 2015.09.04
LED Power
AQF60C SERIES
60 Watts
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. It's recommended to add Varistor 14S561K at L / N input side in parallel.
MECHANICAL DIMENSION
( Top View )
PIN#
Single
1
AC IN (L)
2
AC IN (N)
3
-DC OUT
4
+DC OUT
DERATING
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_3
update : 2015.09.04
LED Power
AQF60C SERIES
60 Watts
EFFICIENCY VERSUS LOAD
AQF60C-24S
VIN
Input Voltage (V)
Efficiency (%)
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
115
180
230
264
Load (%)
0
10
20
30
40
50
87.20
89.00
89.80
89.90
90.00
115V (%)
0.00
86.00
87.50
88.00
86.50
86.69
277
305
230V (%)
0.00
82.13
86.20
86.50
87.80
88.00
90.20
90.30
Load (%)
60
70
80
90
100
115V (%)
87.50
87.70
88.30
89.00
89.07
230V (%)
87.68
87.74
88.78
89.80
89.93
100.00%
90.00%
92.50%
80.00%
90.00%
70.00%
87.50%
60.00%
EFF%
EFF%
Efficiency
90
95.00%
85.00%
50.00%
40.00%
82.50%
30.00%
80.00%
20.00%
77.50%
10.00%
75.00%
90V
VS
115V
180V
230V
264V
277
0.00%
305
0%
10%
20%
30%
40%
VIN
50%
60%
70%
80%
90%
100%
LOAD
AQF60C-36S
VIN
Input Voltage (V)
Efficiency (%)
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
115
180
230
264
Load (%)
0
10
20
30
40
50
89.60
90.30
91.30
91.43
91.50
115V (%)
0.00
81.36
86.80
88.93
89.34
88.43
277
305
230V (%)
0.00
83.50
87.00
89.43
90.70
91.32
91.60
91.70
Load (%)
60
70
80
90
100
115V (%)
89.00
89.42
90.00
90.30
90.50
230V (%)
89.00
89.16
90.50
90.80
91.10
100.00%
90.00%
92.50%
80.00%
90.00%
70.00%
87.50%
60.00%
EFF%
EFF%
Efficiency
90
95.00%
85.00%
50.00%
40.00%
82.50%
30.00%
80.00%
20.00%
77.50%
10.00%
75.00%
90V
VS
115V
180V
230V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
264V
277
305
0.00%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
-3-
VER : A_3
update : 2015.09.04
LED Power
AQF60C SERIES
60 Watts
EFFICIENCY VERSUS LOAD
AQF60C-48S
VIN
Input Voltage (V)
Efficiency (%)
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
115
180
230
264
Load (%)
0
10
20
30
40
50
87.90
89.30
90.45
90.60
90.90
115V (%)
0.00
86.00
87.10
87.00
88.50
88.80
277
305
230V (%)
0.00
81.60
86.40
88.00
89.00
89.15
91.10
91.22
Load (%)
60
70
80
90
100
115V (%)
89.00
88.00
88.15
90.30
89.55
230V (%)
89.30
88.50
88.71
90.80
90.92
100.00%
90.00%
92.50%
80.00%
90.00%
70.00%
87.50%
60.00%
EFF%
EFF%
Efficiency
90
95.00%
85.00%
50.00%
40.00%
82.50%
30.00%
80.00%
20.00%
77.50%
10.00%
75.00%
90V
VS
115V
180V
230V
264V
277
0.00%
305
0%
10%
20%
30%
40%
VIN
50%
60%
70%
80%
90%
100%
LOAD
AQF60C-54S
VIN
Input Voltage (V)
Efficiency (%)
Input Voltage (V)
Efficiency (%)
VS
Efficiency
LOAD
115
180
230
264
Load (%)
0
10
20
30
40
50
87.78
89.00
91.25
91.45
91.60
115V (%)
0.00
86.00
87.10
87.00
88.50
88.80
277
305
230V (%)
0.00
81.60
86.40
88.00
89.00
89.15
91.70
91.75
Load (%)
60
70
80
90
100
115V (%)
87.80
89.00
89.25
89.75
90.00
230V (%)
89.30
89.70
90.20
90.75
91.39
100.00%
90.00%
92.50%
80.00%
90.00%
70.00%
87.50%
60.00%
EFF%
EFF%
Efficiency
90
95.00%
85.00%
50.00%
40.00%
82.50%
30.00%
80.00%
20.00%
77.50%
10.00%
75.00%
90V
VS
115V
180V
230V
VIN
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
264V
277
305
0.00%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
-4-