atc30 series electrical specifications key features

VER : A_5
update : 2015.07.14
AC-DC Power Module
ATC30 SERIES
30 Watts
KEY FEATURES
 Switching Power Module for PCB Mountable
 Fully Encapsulated Plastic Case
 Universal Input Range 90-305VAC
 High Efficiency up to 89%
 Isolation Class II
 <0.3W No Load Input Power
 Very Small 2.52” x 1.77” x 0.92 “ Package
 Screw Terminal For Optional
 CE, CB and UL Approval
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated
Model No.
( Single Output )
Max Output Wattage (W)
Voltage
ATC30-3.3S
16.5W
(Note1)
Frequency (Hz)
Input
Output
Isolation
Environment
Physical
Safety
EMC
ATC30-12S
30W
ATC30-15S
30W
ATC30-24S
30W
90-305 VAC or 120-430 VDC
47-63 Hz
Current (Full load)
600 mA max. (115 VAC) /400 mA max. (230 VAC)
Inrush Current (<2ms)
30 A max. (115 VAC) / 60 A max. (230 VAC)
Leakage Current
0.25 mA max.
No Load Input Power (<240 VAC)
<0.3W
External Fuse (mandatory)
3.15 A slow blow type
Voltage (V.DC.)
3.3V
Voltage Accuracy
±2%
5V
12V
15V
24V
5000
2500
2000
1250
Current (mA) max
5000
Line Regulation (LL-HL) (typ.)
±0.5%
Load Regulation (10-100%) (typ.)
±1.5%
±1%
Maximum Capacitive Load
6800 uF
6800 uF
1600 uF
1200 uF
470 uF
100mVp-p
100mVp-p
150mVp-p
150mVp-p
240mVp-p
Efficiency (at 230 VAC)
80%
84%
89%
86%
86%
Hold-up Time
10 ms min.
Over Power Protection
Hiccup technique, auto-recovery
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Ripple & Noise (max.)
Protection
ATC30-5S
25W
(Note2)
Input-Output (V.AC)
3000V
Input-FG (V.AC)
1500V
Output-FG (V.AC)
500V
Operating Temperature
-40°C…+70°C (with derating)
Storage Temperature
-40°C…+85°C
Max Case Operating Temperature
Under 115 VAC 78°C , others 85°C
Temperature Coefficient
±0.02%/°C
Humidity
95% RH
MTBF
>400,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.52 x 1.77 x 0.92 Inches
Case Material
Plastic resin with Fiberglass (flammability to UL 94V-0)
Weight
130 g
Cooling Method
Free air convection
Agency Approvals
CE, UL/cUL, CB
EMI (Conducted & Radiated Emission)
EN 55022 class B
EMS (Noise Immunity)
EN 55024
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
( 64.0 x 45.0 x 23.5 mm ) Tolerance 0.5 mm
-1-
VER : A_5
update : 2015.07.14
AC-DC Power Module
ATC30 SERIES
30 Watts
NOTE
1. Please check the derating carve for more details.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
3. It's necessary to add Varistor 14S561K at L / N input side in parallel.
4. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw
MECHANICAL DIMENSION
( Top View )
PIN#
Single
1
AC IN (N)
2
AC IN (L)
3
-DC OUT
4
NO PIN
5
+DC OUT
DERATING
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_5
update : 2015.07.14
AC-DC Power Module
ATC30 SERIES
30 Watts
EFFICIENCY VERSUS LOAD
ATC30-12S
VIN
Input Voltage (V)
Efficiency (%)
VS
Efficiency
90
115
180
230
264
305
87.6
88.4
90.2
90.4
90.2
89.9
95.00%
92.50%
90.00%
EFF%
87.50%
85.00%
82.50%
80.00%
77.50%
75.00%
90
115
180
230
264
305
VIN
LOAD
VS
Efficiency
Load (%)
10
20
30
40
50
60
70
80
90
100
230V (%)
84.6
87.9
89.3
90.2
90.3
89.9
89.9
90.1
90.1
90.4
91.00%
90.00%
89.00%
88.00%
EFF%
87.00%
86.00%
85.00%
84.00%
83.00%
82.00%
81.00%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-
VER : A_5
update : 2015.07.14
AC-DC Power Module
ATC30 SERIES
30 Watts
SCREW TERMINAL
ATC30-A2
PIN#
Single
1
NO CONNECT
2
AC IN (N)
3
AC IN (L)
4.
NO CONNECT
5
-DC OUT
6
NO CONNECT
7
+DC OUT
8
NO CONNECT
PIN#
Single
1
NO CONNECT
2
AC IN (N)
3
AC IN (L)
4.
NO CONNECT
5
-DC OUT
6
NO CONNECT
7
+DC OUT
8
NO CONNECT
ATC30-A5
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-4-