VER : A_4 update : 2015.06.05 AC-DC Power Module AYC SERIES 2 Watts KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-305VAC, 47-63 Hz Isolation Class II Maximum No-Load Watts < 0.3W CE, CB and UL Approval 3-Year Product Warranty ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. ( Single Output ) Max Output Wattage (W) Voltage Input Output Protection Isolation Environment Physical Safety EMC AYC-3.3S AYC-5S AYC-9S AYC-12S AYC-15S AYC-24S 2W 90-305 VAC or 120-430 VDC Frequency (Hz) 47-63 Hz Current (Full load) 75 mA max. (115 VAC) / 55 mA max. (230 VAC) Inrush Current (<2ms) 30 A max. (115 VAC) / 50 A max. (230 VAC) Leakage Current (<240 VAC) 0.25 mA max. External Fuse (mandatory) 3.15 A slow blow type External Varistor 14S561K Voltage (V.DC.) 3.3V Voltage Accuracy ±6% Current (mA) max 600 Line Regulation (LL-HL) (typ.) ±5% Load Regulation (10-100%) (typ.) ±6% Minimum Load 0% Maximum Capacitive Load 7000uF Ripple & Noise (Vp-p) 300mV Efficiency (at 115 VAC) 66% Hold-up Time (at 230 VAC) 15 ms min. 5V 9V 12V 15V 24V 400 222 167 133 83 4000uF 1200uF 500uF 350uF 110uF 70% 73% 73% 73% 75% Over Power Protection Hiccup technique, auto-recovery Short Circuit Protection Hiccup mode, indefinite (automatic recovery) Input-Output (V.AC) 3000V Operating Temperature -40°C…+80°C ( with derating ) Storage Temperature -40°C…+85°C Temperature Coefficient ±0.02%/°C Humidity 95% RH MTBF >450,000 h @ 25°C (MIL-HDBK-217F) Dimension (L x W x H) 1.33 x 0.87 x 0.67 Inches ( 33.7 x 22.2 x 17.0 mm ) Tolerance 0.5 mm Case Material Plastic resin with Fiberglass (flammability to UL 94V-0) Weight 20.1 g Cooling Method Free air convection Agency Approvals UL, cUL, CE, CB EMI (Conducted & Radiated Emission) EN 55022 class B EMS (Noise Immunity) EN 55024 http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- VER : A_4 update : 2015.06.05 AC-DC Power Module AYC SERIES 2 Watts NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. Hold-up Time measured at 90% Vout. 3. It's necessary Varistor 14S561K at L / N input side in parallel. 4. It's necessary 10R / 15φ thermistor at L input side in series connection. 5. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw MECHANICAL DIMENSION ( Top View ) BLOCK DIAGRAM http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 PIN# Single 1 AC IN (N) 2 AC IN (L) 3 -DC OUT 4 +DC OUT DERATING -2-