APF100 - ARCH Electronics Corp.

.
VER : B_2
update : 2015.09.04
LED Power
APF100 SERIES
100 Watts
KEY FEATURES
 Fully Isolated Plastic Case with IP67 Level
 Universal Input: 90-305 VAC or 120-430 VDC
 Bulit-in Active PFC Function
 Free Air Convection
 High Reliability
 Isolation Class II
 LED Power Application
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
APF100-12S
Max Output Wattage (W)
Voltage
100W
Input
Output
Protection
Isolation
Environment
Physical
Safety
APF100-36S
APF100-48S
APF100-54S
90-305 VAC or 120-430 VDC
Frequency (Hz)
47-63 Hz
Current (Full load)
1.5 A max. (115 VAC) / 0.7 A max. (230 VAC) / 0.6 A max. (277 VAC)
Inrush Current (<2ms)
40 A max. (115 VAC) / 60 A max. (230 VAC)
Leakage Current
<0.75 mA max.
Power Factor
PF>0.97 (115 VAC) / PF>0.95 (230 VAC) / PF>0.9 (277 VAC) at Full Load
Voltage (V.DC.)
12V
24V
36V
48V
54V
Constant Current Range (V.DC.)
6 ~ 12V
12 ~ 24V
18 ~ 36V
24 ~ 48V
27 ~ 54V
Voltage Accuracy
±2%
Current (Convection) (mA) max
8333
4166
2777
2083
1852
Current ADJ Range (mA)
833 ~ 8333
416 ~ 4166
277 ~2777
208 ~ 2083
185 ~ 1852
Line Regulation
±1%
Load Regulation
±1%
Maximum Capacitive Load
100,000 uF
50,000 uF
8,000 uF
4,000 uF
3,000 uF
Ripple & Noise (max.)
100mVp-p
100mVp-p
100mVp-p
200mVp-p
200mVp-p
Efficiency (typ.)
89%
91.5%
91.5%
91.5%
91.5%
Hold-up Time
25 ms min.
Over Power Protection
Auto recovery
Over Voltage Protection
Auto recovery
Overt Temperature Protection
Auto recovery
Short Circuit Protection
Auto recovery
Input-Output (V.AC)
3750V
Input-FG
(V.AC)
1880V
Output-FG
.(V.AC)
500V
Operating Temperature
-30°C…+60°C (with derating)
Storage Temperature
-40°C…+85°C
Temperature Coefficient
±0.02%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>75,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.
Dimension (L x W x H)
5.67 x 2.76 x 1.48 Inches
Weight
660 g ±15%
Cooling Method
Free air convection
Agency Approvals
EN61347-1:2008、 EN61347-2-13:2006
EMI
EN 55015
(Conducted & Radiated Emission)
EMC
APF100-24S
EMS (Noise Immunity)
EN 61547
Surge
2KV L-N
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
( 144.0 x 70.0 x 37.5 mm ) Tolerance 2mm
-1-
.
VER : B_2
update : 2015.09.04
LED Power
APF100 SERIES
100 Watts
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. It's recommended to add Varistor 14S561K at L / N input side in parallel.
MECHANICAL DIMENSION
( Top View )
DERATING
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
.
VER : B_2
update : 2015.09.04
LED Power
APF100 SERIES
100 Watts
DIMMING OPERATION
Output constant current level can be adjusted through output cable by connecting a
3~10Vdc or 10V PWM signal between DIM+ and DIMI.
3~10V dimming function for output current adjustment (typ.)
110.0%
100.0%
90.0%
80.0%
70.0%
Io
(%)
60.0%
50.0%
40.0%
30.0%
20.0%
10.0%
0.0%
3V
II.
4V
5V
6V
7V
DIM (V)
8V
9V
10V
10V PWM signal for output current adjustment (typ.) : Frequency range:100Hz~3KHz
110.0%
100.0%
90.0%
80.0%
70.0%
Io 60.0%
(%) 50.0%
40.0%
30.0%
20.0%
10.0%
0.0%
30%
40%
50%
60%
70%
80%
90%
100%
DIM(PWM)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-