MK150S C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies series 88-264VAC Auto Ranging Input Compact Footprint High Efficiency Regulated Outputs 4242VDC Isolation Built in EMI Filter 3.5”W x 6”L x 1.75”H Model Number Output Voltage Output Amps (max) Ripple/Noise pp,typ MK150S-5 MK150S-12 MK150S-15 MK150S-24 5 VDC 12 VDC 15 VDC 24 VDC 30 12.5 10 6.25 WWW.ASTRODYNE.COM 100mv 100mv 100mv 100mv ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies MK150S INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: Oper. Temperature Storage Temperature Relative Humidity EMI (Designed to Meet) MTBF 88-132/176-264 VAC Auto Voltage Select 47-63 Hz 20A @ 100VAC * 40A @ 200VAC * OUTPUT SPECIFICATIONS Voltage and Current Line/Load Regulation (NL-FL) Voltage Tolerance DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise Over Voltage Protection Over Current Protection Short Circuit Protection Hold Up Time Turn On Time Rise Time Over/Under Shoot See Selection Chart ± 0.5%, typ ± 1%, typ ± 6%, typ ± 0.03%/°C 100mV, typ 130%, Latching, Re-power * 160%, Auto-recovery Auto-recovery 20mS, typ (Nom I/P, FL) ≤ 1.0 sec, typ ≤ 20 msec, typ < 10% of FS series 0 to +60°C (See Derate Curve) -25 to +85°C * 10% to 90%, non-cond * EN55011, Class B 100,000 Hrs Mil Std 217, 25°C PHYSICAL SPECIFICATIONS Size Construction Weight 6” x 3.5” x 1.75” Enclosed 1.37 lb, (630g) GENERAL SPECIFICATIONS Isolation Efficiency Switching Frequency Safety UL/cUL: UL-EU: CE: CB: I/P-O/P: 4242VDC I/P-Ground: 2121VDC O/P-Ground: 707VDC 77~80%, typ 100Khz, (fixed, typical) UL60950-1 2nd ed./ C22.2 60950-1 2nd ed. EN60950-1 2nd ed. EN60601-1-2 IEC60950-1 2nd ed. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 MK150S C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies MECHANICAL DIMENSIONS (See Note Below) (See Note Below) Pin # Outputs 1 2 3 4 5 6 7 ACL ACN GND + Output + Output - Output - Output series (See Note Below) AAASSSTTTRRRO O D N O OD DYYYN NEEE PPPAAACCCIIIFFFIIICCC CCCO ORRRPPP Note: For our M3 x 0.5 aluminum threaded holes: Recommended 2.5 in-lbs, 3Curve in-lbs maximum (2.9 kgf-cm/3.5 kgf-cm max) 7.torque: Derating PLEASE NOTE: EEELLLimprove EEECCCTTTRRRIIICCCspecifications AAALLL SSSPPPEEECCCIIIFFFIIICCCand AAATTTIIIO To safety O N ON N isolation, connection designations may have changed from prior revisions. Please verify connections per product labels on input and output connections prior to applying power to the unit OUTPUT DERATING CURVE 120% 100% Load(%) 80% Line 2 60% Line 1 Line 3 40% 20% 0% ℃ 10℃ 20℃ 30℃ 40℃ 50℃ 60℃ 70℃ 1. Line 1 : Force air cooling. 2. Line 2 : 12V,15V & 24V convection cooling. 3. Line 3 : 5V convection cooling. WWW.ASTRODYNE.COM 1413 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458