3 6 5 W H i g h D e n s ity PFC Switcher with 12V aux & 5V Stand By ASL365 series Single Outputs with 12V Auxillary and 5 Volt Stand By Universal 90 to 264VAC Input 18W/in3 Power Density 12VDC to 48VDC Outputs 3,000VAC Input to Output Isolation Short Circuit Protection 3” x 5” x 1.28” This specification describes an open frame 365W forced air / 200W convection cooled power supply that provides three independent direct constant voltage outputs, one of which may be configured as a stand by power supply (5V) powered from an external main AC source or UPS and utilizes an active PFC (Power Factor Correction) topology in an industry standard 3” x 5” x 1.28” package. Also included is a 12V auxilary output suitable for driving a fan. The supply shall meet the requirements (80-Plus) of the Energy Star 4.0 document and the anticipated 90+ requirement for 2010. The supply is also RoHS/WEEE compliant. Model Number O/P VDC Iout (Convection / 200LFM) 12V aux. 5VSB (5 Volt Stand By) OVP ASL365-12 ASL365-24 ASL365-48 0.5 / 1A 0.5 / 1A 0.5 / 1A 1 / 2A 1 / 2A 1 / 2A 12VDC 24VDC 48VDC 16.6 / 30.4A 8.3 / 15.2A 4.16 / 7.6A All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted WWW.ASTRODYNE.COM 13.2-15V 26.4-30V 52-60V Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASL365 3 6 5 W H i g h D e n s ity PFC Switcher with 12V aux & 5V Stand By INPUT SPECIFICATIONS Input Voltage Range Harmonic Input Current Input Current FL Input Power Rating Inrush Current Efficiency Input Frequency Power Factor (90VAC) Under Voltage Lockout Transients Leakage Current (115/230 I/P) 90-264VAC EN61000-3-2 (230V/50Hz; 100V/50 or 60Hz) <5A @ 90VAC; <2.5A @ 180VAC <430 Watts 53A @ 110V; 116A @ 220V, typ. 90%, typ. 47-63Hz 0.98% min. No Damage IEC61000-4-4 Level 3 IEC61000-4-5 Level 3 110/275uA OUTPUT SPECIFICATIONS Voltage Adjust ±5% Main Output typ. Load Regulation Main O/P: ±1% max.; all others ±5% Line Regulation ±1% High Line to Low Line Tolerance Main O/P: ±3% 5VSB: ±5% 12V aux.: ±15% Transient Response (50% Load Change) 10% Recover within 1mS Start Up 5VSB: 700mS, typ. All other outputs: 500mS, typ. Hold Up Main O/P: 20mS. typ. 5VSB: 2S, typ. Rise Time 5VSB: 0.7S All Other Outputs: 20mS max. Overshoot (Power On/Off) Vout x 1.1; 50mS max. Ripple/Noise (Note 1) 12V aux: 2% of Output All other outputs: ±1% Short Circuit Auto Recovery; No Damage * Over Current Protection 150%, Auto Recovery Over Voltage Protection (OVP) 5VSB: 5.5-6.8V Main O/P: See Model Selection Chart Remote Sense <250mV drop compensation PS Enable PS is off until enable signal (TTL or Ground) is applied DC OK Signal goes TTL high to indicate DC WWW.ASTRODYNE.COM 5V Standby (5VSB) 12V Auxilary series regulation 2A current always on when AC input is present 1A current to power cooling fan(s) GENERAL SPECIFICATIONS Isolation I/P-O/P Safety Standards Size 3000VAC 1 Minute UL/cUL 60950 3” x 5” x 1.28” ENVIRONMENTAL SPECIFICATIONS Oper. Temperature -20 to +50°C (See Derate Curve)* Max. Heatsink Temperature 110°C @ 50°C ambient Cooling 200LFM >200W O/P Power Relative Humidity 95% Non Condensing Storage Temperature -40 to +80°C * Operating Altitude 5KFT ASL, derated to 40°C @ 10KFT Shock 10G, 11mS Half Sine, 3 Axis Vibration 0.5G, 10-300Hz, 3 Axis MTBF >250,000 Hrs, 75% Load, 35°C EMI/EMC EN55022:1998 (CISPR22 Class B Conducted) Voltage Fluctuation EN61000-3-3 ESD EN61000-4-2, 15KV Air, 8KV Contact Radiated Field EN61000-4-3, 3V/m, 80-1000MHz 80% Modulated; 3M distance EFT EN61000-4-4, 2kV on AC port for 1 minute ±1kV on signal/ctrl lines Surge EN61000-4-5, ±1kV line to line; ±2kV line to earth Conducted RF EN61000-4-6, 3Vrms, 0.15-80MHz 80% Modulated Voltage Variations EN61000-4-11: >95% dip, 0.5 period 30% dip. 0.25 period >95% reduction, 250 periods Harmonic Current Emissions IEC61000-3-2 Class D Note 1: O/P Noise measured directly at the pins/terminals at nominal load with a 0.1uF bypass and 47uF electrolytic capacitor; pk-pk @ 20MHz bandwidth. * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 3 6 5 W H i g h D e n s ity PFC Switcher with 12V aux & 5V Stand By ASL365 series MECHANICAL SPECIFICATION *See Note About J3 *Note: For proper ON operation please provide a connection (short) between Pins 6 (PS ON) and 8 (-5 AUX GND) on Connector J3 WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 3 6 5 W H i g h D e n s ity PFC Switcher with 12V aux & 5V Stand By ASL365 series DERATE CURVE WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458