PFC-375 Series FEATURES Compact 1/2 Brick

PFC-375 Series
375 Watt PFC Front End
Univerter® Power Factor Correction Module
The Univerter PFC-375 Power Factor Correction
modules are AC to DC converters that operate from
a wide range of AC input voltages and frequencies
with extremely high conversion efficiency and near
unity power factor. The PFC-375 produces an output
of 375 VDC suitable for driving 300V input DC-DC
converters, motors, pumps and a host of other loads.
The wide AC input voltage range and frequency
range are 90 to 265 VAC and 47 to 880 Hz
respectively, making this product suitable for land,
sea and air based applications requiring AC to DC
conversion with line harmonic reduction or PFC.
Typical applications include 115/230 VAC, 50/60 Hz
systems and 115 VAC, 400 Hz or 360-800 Hz
military and commercial aircraft power systems
requiring MIL-STD-704 or DO-160 compliance.
These compact, rugged modules use advanced
e lec tr ic al d es i gn a n d th er m al m ana g em ent
techniques to m ak e them suitable for harsh
environments and thermally challenged applications.
FEATURES
Optimized for Airborne and other Harsh
Environment Applications
Compact 1/2 Brick Package
2.4 x 2.3 x 0.5 in.
MODEL SELECTION
Part Number
Structure:
90-265 VAC INPUT, 47-800Hz
370VDC Output
W
Efficiency 94% typical 115VAC, 400Hz Input,
97% typical at 230VAC, 50Hz input
Extremely High Power Factor and Low THD
Potted Module with IMS Technology
-40°C to +100°C Base Plate Rated – No Output
Power Derating
Available in Lead Free ROHS Compliant or
SnPb Solder Versions
Ride-Through Time is very long and depends
only on the Bulk Cap Voltage, down to 40 Vdc.
Load Enable directly interfaces with
MicroVerter and PicoVerter DC-DC Converter
logic on/off pin.
XX
YYY
PFC-375W-XX-YYY
A: Aux Power Output
P: Parallel Option
T: Extended Temp Range
-55°C to +100°C
C: Conformal Coating
LF: Lead Free and RoHS
Compliant
RL: Tin-Free construction
Other Special Configurations
TBD
MODEL
Input
Voltage, VAC
Input
Frequency, Hz
PFC-375
90 - 265
47 - 880
PFC-375 Series
375 Watt Power Factor Correction Module
375 VDC Output, ½ Brick Package
ABSOLUTE MAXIMUM RATINGS
Exceeding absolute maximum ratings may
cause permanent damage or reduce
reliability
PARAMETER
OPTION
MINIMUM
MAXIMUM
UNITS
CONDITIONS
Input Voltage (AC1 to AC2)
265
VAC
Continuous
Input Voltage (AC1 to AC2)
280
VAC
100ms max.
Circuit-to-Case Voltage
2500
Vdc
Storage Temperature
Standard
-55
110
°C
Operating Temperature
Standard
-40
100
°C
Baseplate
Operating Temperature
T
-55
100
°C
Baseplate
260
°C
< 5 sec
Soldering Temperature
SPECIFICATIONS
Electrical specifications apply for in = 115Vac, 60 Hz to 400 Hz Full Load, Tc = 25 °C and external application circuit
components shown in figure 1, unless specified otherwise.
INPUT SPECIFICATIONS
MINIMUM
TYPICAL
MAXIMUM
85
115/230
265
VAC
47
50/60/400
880
Hz
Input Voltage
Input Line Frequency
Power Factor
0.99
UNITS
CONDITIONS
1.0
Total Harmonic Distortion
<5%
Maximum Input Current
3.5
4.5
%
Conforming to IEC 1000-3-2
Arms
Vin = 90VAC, Full Load, Tc = 25°C
Inrush Current
Input 115 Vac
15
Apeak
Thermistor Temperature 25°C
Input 230 Vac
30
Apeak
Thermistor Temperature 25°C
µArms
Vin = 115VAC, TC=25°C
Input-to-Case Leakage Current
Start-up Voltage
Input Under Voltage
Hold-up time/Ride Through time
Astrodyne Corp. 1-800-823-8082
TBD
70
80
65
85
75
30
VAC
85
VAC
ms
PFC-375 Datasheet 05-02-12
HV Bus voltage at end of hold-up/ride
through interval – 220VDC
Page 2 of 6
PFC-375 Series
375 Watt Power Factor Correction Module
375 VDC Output, ½ Brick Package
OUTPUT SPECIFICATIONS
Output Voltage
MINIMUM
TYPICAL
MAXIMUM
370
375
Output Over Voltage Protection
Output Current
0
Output Current Limit
NONE
Efficiency
94%
Output Ripple
Vaux Output Voltage (OPTION-A)
UNITS
CONDITIONS
380
Vdc
Vin = 115VAC, Tc = 25°C
415
Vdc
Non-shutdown Vmax.
1.0
ADC
%
13
12.0
CONTROL SPECIFICATIONS
12.5
MINIMUM
18.0
TYPICAL
V p-p
Vin = 115VAC, f=60Hz
Vdc
Vaux Load = _________
MAXIMUM
UNITS
LD ENA Threshold (Vout rising)
320
360
Vdc
LD ENA threshold (Vout falling)
205
235
Vdc
LD ENA Logic Low Current
20
mA
LD ENA Logic Low Voltage
0.5
Vdc
ISOLATION SPECIFICATIONS
MINIMUM
Input-to-Output Isolation
TYPICAL
MAXIMUM
Non-isolated
UNITS
2500
Vdc
Output-to-Case Isolation
2500
Vdc
THERMAL/ MECHANICAL SPECIFICATIONS
TBD
pF
TYPICAL
MAXIMUM
Thermal Shutdown Temperature
105
110
Thermal Shutdown Restart Temperature
Thermal Resistance, Case to Ambient
Size
Weight
Astrodyne Corp. 1-800-823-8082
MINIMUM
CONDITIONS
Vdc
Input-to-Case Isolation
Circuit-to-Case Capacitance
CONDITIONS
UNITS
CONDITIONS
°C
Baseplate temperature
85
°C
Baseplate temperature
6.6
°C/W
Natural Convection in Free Air,
No Heatsink, Tc = 100°C
inch
1/2 Brick
2.40 x 2.30 x 0.50
4.2
PFC-375 Datasheet 05-02-12
oz.
Page 3 of 6
PFC-375 Series
375 Watt Power Factor Correction Module
375 VDC Output, ½ Brick Package
EMC COMPLIANCE
EXTERNAL FILTER
MIL-STD-461E
TBD
RTCA DO-160E
TBD
RELIABILITY
MTBF Prediction
Astrodyne Corp. 1-800-823-8082
MINIMUM
TYPICAL
COMPLIANCE
MAXIMUM
2.0
PFC-375 Datasheet 05-02-12
UNITS
CONDITIONS
M hrs
MIL-217F GB 25°C
Page 4 of 6
PFC-375 Series
375 Watt Power Factor Correction Module
375 VDC Output, ½ Brick Package
Pin Function/Description
LD ENA
AC1, AC2
These are the AC input terminals. The input should
be connected to a suitable filter such as the F250-6
in order for the PFC module to perform properly and
to comply with applicable EMI/EMC performance
standards. A standard filter for the PFC-375 is
under development. A suitable fuse and inrush
limiting thermistor should be connected in series
with the input as well.
+Out
This is the positive output terminal. It should be
connected to the positive terminal of the bulk
capacitor. The 375 VDC output will appear here
with respect to the – Out terminal. The hold-up
capacitor value ranges are provided in the
specifications.
This terminal provides logic control to downstream
DC/DC converters. The LD ENA signal will be an
active low signal until the PFC output voltage
reaches a specified value after the application of
input voltage. It will switch logic state to open
collector upon the PFC output reaching 340 Vdc. If
AC power is lost or removed, the LD ENA will return
to the low state when the PFC output drops to 220
Vdc. For most RO DC-DC products, it is not
necessary to use the LD ENA terminal.
-Out
This is the PFC negative output terminal. It should
be connected directly to the negative terminal of the
hold up capacitor. The hold-up capacitor must be
located in close proximity to the PFC output
terminals.
Application Diagram
The connection diagram below shows proper connections of the PFC-375 module to a typical application circuit
including fuse, filter, bulk capacitor and inrush limiting thermistor.
Figure 1 – Typical Application Circuit
Additional applications information is available to assist in the selection of the external component
Astrodyne Corp. 1-800-823-8082
PFC-375 Datasheet 05-02-12
Page 5 of 6
PFC-375 Series
375 Watt Power Factor Correction Module
375 VDC Output, ½ Brick Package
Astrodyne Corp. 1-800-823-8082
PFC-375 Datasheet 05-02-12
Page 6 of 6