PCB terminal blocks and connectors for power

COMBICON power
PCB terminal blocks and
connectors for power
electronics
COMBICON power
Your connection for power electronics
COMBICON power is the PCB terminal
block and connector range from
Phoenix Contact for PCB connections
from 16 A to 125 A. Particularly in power
electronics, more and more components
and functions are being concentrated on
PCBs. In order to rationalize the installation
and wiring work, a PCB connection that
is both convenient and economic to use is
thus indispensable.
COMBICON
connectors
Up to 125 A
Up to 35 mm2
600 V UL
Whether in frequency inverters or
power supply and charging units, for the
control of wind power generators or for
the connection of solar systems, for the
operation of electric vehicles or simply for
connecting power PCBs: Phoenix Contact
provides you with the perfect connection
for power electronics.
COMBICON
PCB terminal blocks
Up to 125 A
Up to 35 mm2
600 V UL
2
PHOENIX CONTACT
Decide yourself, whether you want a direct
connection to the PCB using our highcapacity PCB terminal blocks, or whether
you would rather operate your application
in a more service-friendly manner with
connectors. Both product types offer you
practical advantages and a host of
connection options.
Customer-specific versions
If you depend on reliability and high
power reserves, you will find the right
connection for your application in the
COMBICON power product range.
But even the largest of standard ranges
is sometimes not sufficient. Here too,
Phoenix Contact can still help you and
develop customized solutions together
with you. So go ahead: minimize your
wiring work and benefit from the
advantages of COMBICON power.
PHOENIX CONTACT
3
COMBICON power connectors
You don't have to be small to be quick
COMBICON power connectors offer
professional solutions for easy connections
in power electronics of up to 125 A.
For applications with high
vibrations
Besides the proven screw connection with
the tension sleeve principle, the new pushin spring-cage connection offers a quick
and tool-free conductor connection. Power
electronics thus become fully pluggable and
easy to maintain.
Take a look at the different combination
options offered by the COMBICON power
connector range and decide for yourself.
Click and Lock
Automatic locking of the plug-in
connection when plugging in.
Space-saving design
PC 5 with Click and Lock
Screw flange
Vibration-resistant connection with
the threaded flange
4
PHOENIX CONTACT
Connection methods
for connectors
Great variety of
plug-in connections
Other features
Push-in connection
Spring-cage connection for quick
conductor contacting without using
a tool
Inverted contact systems
Optimum touch protection for
conductive contacts
Compact design
Unlimited 600 V UL approvals even
with a 6.35 mm pitch
Screw connection
Conductor connection with the
proven tension sleeve principle
PCB-PCB connection
Panel feed-throughs
Fixing in the housing using a screw
or an easy-to-operate snap-on
mechanism without any additional
tool
TWIN connectors
Connecting two conductors to one
electrical potential
Available with push-in spring-cage
connection (TSPC 5) or screw
connection (TPC 16)
Hanging cable-to-cable
connection
Shielding function
Connection of the shield in order
to meet the EMC requirements
Additional strain relief
PHOENIX CONTACT
5
COMBICON power – PCB terminal blocks
High currents firmly under control
COMBICON power impresses with a
wide range of high-performance PCB
terminal blocks of up to 125 A and modern
connection methods.
The high-performance PC terminal blocks
provide connection options for conductors
with cross-sections of 0.2 mm2 to 35 mm2.
The conductor is easily connected using
tension sleeve or the push-in or spring-cage
connection method.
SPT 5 in horizontal and
vertical versions
6
PHOENIX CONTACT
Connection methods for
PCB terminal blocks
Other features
Push-in connection
Spring-cage connection for quick
conductor contacting without using
a tool
Codability
Color coding possible from
position to position thanks to the
modular design
Compact design
Unlimited 600 V UL approvals even
with a 6.35 mm pitch
Screw connection
Conductor connection with the
proven tension sleeve principle
Marking
Individual labeling using SK strips,
Zack marker strip or direct labeling
Integrated test connection
Continuous operating state
monitoring
Spring-cage connection
Force-optimized spring-cage
connection for reliable connection
Mounting flange
Additional screw connection with
mounting flanges
Efficient relief for the solder pins
Plug-in bridge
Easy potential distribution,
for star/delta circuits, for example.
PHOENIX CONTACT
7
UL certification
Technical information about
PCB connection
Approvals such as UL/CUL always bring up
new questions for device manufacturers.
As a responsible manufacturer of device
connection technology, we develop and
test our products such that our customers
will not have any problems with the
international approval of their devices.
When plugged in, the COMBICON power
connectors meet all requirements of
increased shock protectionn for electrical
power drives as per IEC 61800-5-1.
1800-5-1.
8
PHOENIX CONTACT
UL recognizes terminals
and connectors as individual
components (UL 1059). In the
end application, the components
undergo a final evaluation and
are approved together with the
device (UL 508 (C) and UL 840).
u
®
Product standards
Device standards
UL 1059 "Terminal Blocks"
UL 508 "Industrial control equipment"
Phoenix Contact products are mainly tested and recognized
in acc. with UL 1059 so that they can be used in industrial
applications without any restrictions.
Terminals that have been recognized as per UL 1059 meet
the field wiring terminal block requirements stated in UL 508
and can thus be used in devices complying with this standard
without any restrictions. UL 508 also allows the alternative
measurement as per UL 840.
The following table lists the air and creepage distances
required for the components.
The Use Group describes the future usage range of the
termination device.
Use
Group
Definition
Max.
voltage
(V)
UL 508 C "Power conversion equipment"
Required
distances (mm)
Clearance
Creepage
distance
A
Operating elements, panels and similar
150
300
600
12.7
19.1
25.4
19.1
31.8
50.8
B
Conventional devices, incl. office
and electronic data processing devices
and similar
150
300
600
1.6
2.4
9.5
1.6
2.4
12.7
Industrial applications,
without any restrictions
150
300
600
3.2
6.4
9.5
6.4
9.5
12.7
C
D
Industrial applications, items with limited
performance data
(Limited rating)
300
600
1.6
4.8
3.2
9.5
This UL standard is applicable especially for power electronics
(motor controllers, frequency inverters, etc.). The field
wiring terminal block requirements resemble the UL 508
specifications. Here too, the alternative measurement as per
UL 840 is possible.
UL 840 "Insulation coordination including clearances
and creepage distances for electrical equipment"
This standard describes the alternative procedure for designing
the isolation of end products for defined ambient conditions
(surge voltage category, pollution degree, material index) as
long as the device standard allows this.
The following procedures are offered as per UL 840 (3rd
edition 2005) in order to determine the air and creepage
distances:
1. Equivalent clearances The clearances can fall below
the clearance values required in the device standard if the
termination device passes the surge voltage tests described
in UL 840 (table 7.1) without sparkover. The surge voltage
value depends on the clearance required in the product
standard.
2. Clearances for limited surge voltages If it has been
ensured that the surge voltages occurring during the
operation do not exceed a defined maximum value, the
required clearances can also be determined as per table 8.1
if the pollution degree is known.
3. Creepage distances
The general minimum creepage distance requirements
and the special minimum creepage distance requirements
for PCBs described in table 9.1 taking into consideration
the operating voltage, the pollution degree and the creep
resistance of the material must be fulfilled.
PHOENIX CONTACT
9
High capacity PCB
PCB layout for 125 A
Together with high current PCBs, the
COMBICON power connectors enable a
current carrying capacity of up to 125 A.
Different PCB production technologies
offer new device design options. The
functions and modules required can thus be
concentrated on a single PCB, making the
devices compact.
Other assembly processes as well as the
expensive additional device wiring are
therefore not required.
Three different technologies:
are distinguished in PCB production
1. Multi-layer technology
Up to max. 210 μm on the outer layers
Up to max. 400 μm on the inner layers
Advantages: - Better heat distribution
- Transport of higher currents
- Substitute for cut and bend constructions
2. Thick copper technology
Solid copper core inner layers
Inner layers 0.6 – 2 mm
Different and even asymmetrical layer structures are possible
Advantages: - Reduction in interfaces
- Through-contacting not required
- Patented high current technology
3. Wirelaid PCB technology
Enamel-insulated wires in the inside of the PCB
Connection of the contact points using modern
micro-welding technology
Advantages: - High current densities thanks to additional wires
- Control and power sections can be provided on a
single PCB
Thermogram of a test application
with 125 A
10
PHOENIX CONTACT
Three steps to your device approval as
per UL 508 (C) and UL 840
Approval
Pollution degree
The approvals in the product standard
as per UL 1059 and IEC 60664 can be
found in the left column in the upper
line. Moreover, every matrix also gives
information about the resulting device
standards as per UL 508 and UL 840 that
are applicable for any combination of
connector and a suitable base strip.
1. Product standards
Use Group
The matrices on the following pages will
help in finding the right approval for your
device quickly and reliably.
Rated
insulation
voltage
B
UL 1059 C
D
IEC 60664
2
3
Rated
current
250 V
300 V
-
16 A
10 A
320 V
250 V
-
16 A
16 A
The approval for the
individual product as
per UL 1059 in the use
groups B, C and D or
as per IEC 60664 in the
pollution degrees 2 and
3 can be found beside
or below the product
photos.
2. Combination options
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
Connectors
up to 6 mm2
In the center of the matrix, you will
find the approvals for all mutually
suitable combinations of male and
female contacts.
3. Device standards
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
Example for the connector and base strip
combination with the resulting approval as per UL.
600 V UL
… as per UL 508 (C)
The values in the orange field are the
approval values of the device standard
in the UL 508 (C) use groups (refer to
page 9).
… as per UL 840
The values in the yellow field result
from the alternative measurement as
per UL 840 in the pollution degrees
2 and 3. Prerequisite for the specified
values is the fulfillment of the points
listed on page 9 under UL 840.
This button shows all items in the
COMBICON power range which
fulfill the air and creepage distances
even in field wiring applications for an
unlimited 600 V UL approval.
PHOENIX CONTACT
11
Connectors up to
2.5 mm2 conductor
cross-section
Male contacts
Conductor cross-section
30 - 12 AWG
26 - 12 AWG
2.5 mm2
5.08 mm
Standard
Pitch
FKIC 2,5 HC/...ST-5,08
MSTB(V)2,5 HC/...-GF-5,08
FKIC 2,5 HC/...-STF-5,08
250 V
300 V
320 V
250 V
250 V
300 V
320 V
250 V
Flange
Approval
UL 1059
30 - 12 AWG
MSTB 2,5 HC/...-ST-5,08
MSTB 2,5 HC/...-STF-5,08
5.08 mm
MVSTB(R/W) 2,5 HC/...-STF-5,08
2.5 mm
UL 1059
FKC 2,5 HC/...-STF-5,08
IC(V) 2,5 HC /...-GF-5,08
7.62 mm
30 - 12 AWG
B
C
D
2
3
B
C
D
2
3
B
C
D
2
3
IEC 60664
UL 1059
12
2
3
IEC 60664
UL 1059
IC(V) 2,5 HC/...-G-5,08
B
C
D
IEC 60664
2
26 - 12 AWG
Female contacts
UL 1059
FKC 2,5 HC/...-ST-5,08
2
3
IEC 60664
MSTBT 2,5 HC/...-ST-5,08
MVSTB(R/W) 2,5 HC/...-ST-5,08
B
C
D
IEC 60664
UL 1059
B
C
D
600 V UL
GMSTB 2,5 HCV/...-ST-7,62
GIC 2,5 HC/...-G-7,62
PHOENIX CONTACT
2
3
IEC 60664
UL 1059
IEC 60664
Pollution degree
Standard
Use Group
UL 1059
Pitch
Conductor crosssection
Flange
MSTB(V)A 2,5 HC/...-G-5,08
B
C
D
2
3
Use Group
Pollution
degree
IEC 60664
Rated
insulation
voltage
Rated
current
250 V
300 V
-
16 A
10 A
320 V
250 V
-
16 A
16 A
250 V
300 V
-
16 A
10 A
320 V
250 V
-
16 A
16 A
250 V
300 V
-
16 A
10 A
320 V
250 V
-
16 A
16 A
250 V
300 V
-
16 A
10 A
320 V
250 V
-
16 A
16 A
250 V
300 V
-
16 A
10 A
320 V
250 V
-
16 A
16 A
600 V
600 V
-
-
16 A
16 A
-
1,000 V
1,000 V
-
16 A
16 A
250 V
300 V
-
16 A
10 A
630 V
400 V
-
16 A
16 A
B
C
D
2
3
-
16 A
10 A
16 A
16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
-
16 A
10 A
16 A
16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
320 V - 16 A
250 V - 16 A
30 - 12 AWG
7.62 mm
600 V UL
GMSTBA 2,5 HC/...-G-7,62
250 V
300 V
630 V
400 V
-
16 A
10 A
16 A
16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
630 V - 16 A
400 V - 16 A
UL 508 (C)
600 V - 16 A
600 V - 16 A
–
UL 840
630 V - 16 A
400 V - 16 A
GIC 2,5 HCV/...-ST-7,62
600 V
600 V
1,000 V
1,000 V
-
16 A
16 A
16 A
16 A
UL 508 (C)
600 V - 16 A
600 V - 16 A
–
UL 840
1,000 V - 16 A
1,000 V - 16 A
UL 508 (C)
250 V - 16 A
–
300 V - 10 A
UL 840
630 V - 16 A
400 V - 16 A
PHOENIX CONTACT
13
Connectors up to
6 mm2 conductor
cross-section
30 - 10
4m
Conductor cross-section
Standard
Pitch
DFK-PC 4/...-G-7,62-FS4,8
Flange
PC(V) 4/...-G-7.62
Flange
Shield
Approval
Pollution degree
Standard
Use Group
Pitch
Conductor cross-section
Shield
PC(V) 4/...-GF-7.62
B
UL 1059 C
D
IEC 60664
PC 4/...-STF-7.62
2
3
B
UL 1059 C
D
4 mm2
30 - 10 AWG
PC 4/...-ST-7.62
600 V UL
PC 4 HV/...-ST-7.62
600 V UL
IEC 60664
PC 4 HV/...-STF-7.62
2
3
B
UL 1059 C
D
Female contacts
600 V UL
7.62 mm
PC 4 HV/...-STF-SH-7.62
IEC 60664
2
3
B
UL 1059 C
D
600 V UL
PC 5/...-ST-7.62
600 V UL
PC 5/...-STF-7.62
600 V UL
PC 5/...-STF-SH-7.62
IEC 60664
2
3
6 mm2
24 - 8 AWG
B
UL 1059 C
D
600 V UL
SPC 5/...-ST-7.62
600 V UL
SPC 5/...-STF-7.62
600 V UL
SPC 5/...-STF-SH-7,62
IEC 60664
600
UL*V
600
UL*V
TSPC 5/...-STF-7.62
IEC 60664
2
3
2
3
B
UL 1059 C
D
14
IPC(V) 5/...-G(U)-7.62
PHOENIX CONTACT
IPC(V) 5/...-GF(U)-7.62
IEC 60664
Rated
insulation
voltage
2
3
Rated
current
300 V
300 V
600 V
-
20 A
20 A
5A
630 V
400 V
-
20 A
20 A
600 V
600 V
-
-
20 A
20 A
-
1,000 V 800 V -
20 A
20 A
600 V
600 V
-
-
20 A
20 A
-
800 V
500 V
-
20 A
20 A
600 V
600 V
-
-
41 A
41 A
-
1,000 V 1,000 V -
41 A
41 A
600 V
600 V
-
B
UL 1059 C
D
TSPC 5/...-ST-7.62
B
UL 1059 Use Group C
D
2
IEC 60664 Pollution
degree 3
-
35 A
35 A
-
1,000 V 1,000 V -
41 A
41 A
600 V * 600 V * -
35 A *
35 A *
-
1,000 V 1,000 V -
41 A
41 A
300 V
300 V
600 V
-
41 A
41 A
5A
630 V
630 V
-
41 A
41 A
300 V
300 V
630 V
400 V
-
20 A
20 A
20 A
20 A
300 V
300 V
400 V
400 V
-
20 A
20 A
15 A
15 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
630 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
630 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
400 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
400 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
400 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
400 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
–
UL 840
400 V - 20 A
400 V - 20 A
Male contacts
0 AWG
mm2
24 - 8 AWG
6 mm2
7.62 mm
600V UL
DFK-PC 4/...-GF-7,62
PCVK 4-7,62-(PE)
PC(V) 5/...-G(U)-7,62
IPC 5/...-ST-7,62
PC(V) 5/...-GF(U)-7,62
IPC 5/...-ST(G)F-7,62
600V UL*
600V UL*
ISPC 5/...STGCL-7,62
DFK-PC 5/...ST-7,62
600V UL
600V UL*
ISPC 5/...-ST(G)F-7,62
600V UL*
DFK-PC 5/...STF-7,62
600V UL
-
20 A
20 A
5A
20 A
20 A
300 V
300 V
600 V
630 V
500 V
-
20 A
20 A
5A
20 A
20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
400 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
500 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
500 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
500 V - 20 A
UL 508 (C)
300 V - 20 A
300 V - 20 A
600 V - 5 A
UL 840
630 V - 20 A
500 V - 20 A
300 V
150 V
630 V
500 V
-
41 A
41 A
41 A
41 A
600 V
600 V
1,000 V
1,000 V
-
41 A
41 A
41 A
41 A
DFK-PC(V) 5/...-GF(U)-7,62
600V UL*
IPC 5/...-ST(G)F-SH-7.62
300 V
300 V
600 V
630 V
400 V
DFK-PC(V) 5/...-G(U)-7,62
DFK-PC 5/...STF-SH-7,62 DFK-PC 5/...-GF(U)-SH-7.62
600 V *
600 V *
1,000 V
1,000 V
-
35 A *
35 A *
41 A
41 A
600 V *
600 V *
1,000 V
1,000 V
-
41 A *
41 A *
41 A
41 A
UL 508 (C)
UL 508 (C)
UL 508 (C)
UL 508 (C)
300 V - 41 A
600 V - 41 A
600 V - 35 A
600 V - 41 A
150 V - 41 A
600 V - 41 A
600 V - 35 A
600 V - 41 A
–
–
–
–
UL 840
UL 840
UL 840
UL 840
630 V - 41 A
1,000 V - 41 A
1,000 V - 35 A
1,000 V - 41 A
500 V - 41 A
1,000 V - 41 A
1,000 V - 35 A
1,000 V - 41 A
UL 508 (C)
UL 508 (C)
UL 508 (C)
UL 508 (C)
300 V - 35 A
600 V - 35 A
600 V - 35 A
600 V - 35 A
150 V - 35 A
600 V - 35 A
600 V - 35 A
600 V - 35 A
–
–
–
–
UL 840
UL 840
UL 840
UL 840
630 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
500 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
UL 508 (C)
UL 508 (C)
UL 508 (C)
UL 508 (C)
300 V - 35 A
600 V - 35 A
600 V - 35 A
600 V - 35 A
150 V - 35 A
600 V - 35 A
600 V - 35 A
600 V - 35 A
–
–
–
–
UL 840
UL 840
UL 840
UL 840
630 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
500 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
1,000 V - 35 A
UL 508 (C)
UL 508 (C)
UL 508 (C)
300 V - 41 A
300 V - 41 A
300 V - 35 A
150 V - 41 A
300 V - 41 A
300 V - 35 A
–
–
–
UL 840
UL 840
UL 840
630 V - 41 A
630 V - 41 A
630 V - 35 A
500 V - 41 A
630 V - 41 A
630 V - 35 A
* The specified UL value is expected for the approbation. The corresponding approval of this article is being prepared.
300 V
150 V
630 V
500 V
-
41 A
41 A
41 A
41 A
UL 508 (C)
300 V - 41 A
150 V - 41 A
–
UL 840
630 V - 41 A
500 V - 41 A
UL 508 (C)
300 V - 35 A
150 V - 35 A
–
UL 840
630 V - 35 A
500 V - 35 A
UL 508 (C)
300 V - 35 A
150 V - 35 A
–
UL 840
630 V - 35 A
500 V - 35 A
PHOENIX CONTACT
15
Connectors up to
16 mm2 conductor
cross-section
Conductor cross-section
Standard
Pitch
Flange
PC(V) 6-16 /...-G1(U)-10,16
I
Flange
Shield
Approval
Pollution degree
Standard
Use Group
Pitch
IP
B
UL 1059 C
D
6 mm2
20 - 8 AWG
Conductor cross-section
Shield
PC(V) 6-16/...-G1F(U)-10,16
600 V UL
PC(U) 6/...-ST-10,16
600 V UL
PC 6/...-STF-10,16
600 V UL
PC 6/...-STF-SH-10,16
IEC 60664
600 V UL
600 V UL
PC 16/...-STF-10,16
600 V UL
PC 16/...-STF-SH-10,16
IEC 60664
2
3
2
3
600 VUL
IEC 60664
TPC 16/...-STF-10,16
10.16 mm
20 - 6 AWG
16 mm2
Female contacts
600 VUL
B
UL 1059 C
D
IPC(V) 16/...G(U)-10,16
IEC 60664
IPC(V) 16/...GF(U)-10,16
DFK-IPC(V) 16/...-GF(U)-10,16
DFK-IPC16 /...-GF(U)-SH-10,16
IEC 60664
2
3
18 - 4 AWG
16
600 V UL
600 V UL
DFK-IPC 16/...-STF-10,16
600 V UL
DFK-IPC 16/...-STF-SH-10,16
IEC 60664
2
3
600 V UL
600 V UL
SPC 16/...-STF-10,16
600 V UL
SPC 16/...-STF-SH-10,16
IEC 60664
-
66 A
66 A
-
1,000 V 1,000 V -
76 A
76 A
-
66 A
66 A
-
1,000 V 1,000 V -
76 A
76 A
-
66 A
66 A
5A
1,000 V 1,000 V -
76 A
76 A
-
66 A
66 A
5A
1,000 V 1,000 V -
76 A
76 A
600 V
600 V
2
3
B
UL 1059 C
D
SPC 16/...-ST-10,16
PHOENIX CONTACT
41 A
41 A
300 V
300 V
600 V
B
UL 1059 C
D
DFK-IPC 16/...-ST-10,16
1,000 V 1,000 V -
300 V
300 V
600 V
B
UL 1059 C
D
DFK-IPC(V) 16/...-G(U)-10,16
50 A
50 A
-
600 V
600 V
2
3
-
66 A
66 A
-
1,000 V 1,000 V -
76 A
76 A
600 V
600 V
2
3
Rated
current
-
600 V
600 V
-
B
UL 1059 C
D
TPC 16/...-ST-10,16
Rated
insulation
voltage
600 V
600 V
-
B
UL 1059 C
D
PC 16/...-ST-10,16
B
UL 1059 Use Group C
D
2
IEC 60664 Pollution
degree 3
-
66 A
66 A
-
1,000 V 1,000 V -
76 A
76 A
300 V
300 V
600 V
1,000 V
1,000 V
-
66 A
66 A
5A
76 A
76 A
UL 508 (C)
300 V - 50 A
300 V - 50 A
600 V - 5 A
UL 840
1,000 V - 41 A
1,000 V - 41 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
Male contacts
18 - 6 AWG
16 mm2
10.16 mm
600 V UL
IPC 16 /...-ST-10,16
600 V UL
ISPC 16 /...-ST-10,16
600 V UL
PC 16/...-ST(G)F-10,16
600 V UL
DFK-PC 6-16/...-G(U)-10,16
DFK-PC 16/...-ST-10,16
DFK-PC 6-16/...-GF(U)-10,16
DFK-PC 16/...-STF-10,16
600 V UL
600 V UL
ISPC 16/...-ST(G)F-10,16
600 V UL
600 V UL
PC 16/...-ST(G)F-SH-10,16
600 V
600 V
1,000 V
1,000 V
-
66 A
66 A
76 A
76 A
UL 508 (C)
600 V - 50 A
600 V - 50 A
–
UL 840
1,000 V - 41 A
1,000 V - 41 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
DFK-PC 6-16/...-GF(U)-SH-10,16 DFK-PC 16/...-STF-SH-10,16
600 V
600 V
1,000 V
1,000 V
-
66 A
66 A
76 A
76 A
UL 508 (C)
600 V - 50 A
600 V - 50 A
–
UL 840
1,000 V - 41 A
1,000 V - 41 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
300 V
300 V
600 V
1,000 V
1,000 V
-
66 A
66 A
5A
76 A
76 A
600 V
600 V
1,000 V
1,000 V
-
66 A
66 A
76 A
76 A
UL 508 (C)
300 V - 50 A
300 V - 50 A
600 V - 5 A
UL 840
1,000 V - 41 A
1,000 V - 41 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 50 A
600 V - 50 A
–
UL 840
1,000 V - 41 A
1,000 V - 41 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
300 V - 66 A
300 V - 66 A
600 V - 5 A
UL 840
1,000 V - 66 A
1,000 V - 66 A
UL 508 (C)
600 V - 66 A
600 V - 66 A
–
UL 840
1,000 V - 66 A
1,000 V - 66 A
PHOENIX
PHOENIX
CONTACT
CONTACT 1717
Connectors up to
35 mm2 conductor
cross-section
Male contacts
20 - 2 AWG
35 mm2
Conductor cross-section
15 mm
Pitch
600V UL*
Pollution degree
Use Group
Pitch
Conductor crosssection
PC(V) 35 HC/...-GF-15,0
B
UL 1059 Use Group C
D
2
IEC 60664 Pollution
degree 3
Rated
insulation
voltage
Rated
current
600 V *
600 V *
1,000 V
1,000 V
-
115 A*
115 A*
125 A
125 A
UL 508 (C)
600 V - 115 A
600 V - 115 A
UL 840
600V UL*
2 1,000 V
125 A
1,000 V - 115 A
IEC 60664
PC 35 HC/...- STF-15,0
1,000 V - 115 A
3 1,000 V
125 A
UL 508 (C)
B
600 V *
115 A*
600 V - 115 A
UL 1059 C
600 V *
115 A*
600 V - 115 A
D
UL 840
600V UL*
2 1,000 V
125 A
1,000 V - 115 A
IEC 60664
PC 35 HC/...-STF-SH-15,0
1,000 V - 115 A
3 1,000 V
125 A
* The specified UL value is expected for the approbation. The corresponding approval of this article is being prepared.
18
15 mm
35 mm2
B
UL 1059 C
D
20 - 2 AWG
Female contacts
Approval
PHOENIX CONTACT
600 V *
600 V *
-
115 A*
115 A*
-
600V UL*
PC 35 HC/4-GF-SH-15,0
600 V *
600 V *
1,000 V
1,000 V
-
115 A*
115 A*
125 A
125 A
UL 508 (C)
600 V - 115 A
600 V - 115 A
UL 840
1,000 V - 115 A
1,000 V - 115 A
UL 508 (C)
600 V - 115 A
600 V - 115 A
UL 840
1,000 V - 115 A
1,000 V - 115 A
A New Record!
Safe connection paired with high capacity
can be plugged
onto
PCB
The PC 35 series is normally equipped with a
screw flange which connects the connector and
the base strip safely. Thanks to the threaded flange
on the base strip, this can also be used as panel
feed-through, thus offering a firm hold in the device
without any additional work.
PHOENIX CONTACT
19
PCB terminal blocks
up to 6 mm2 conductor
cross-section
Pollution degree
Z pinning
Use Group
Linear pinning
Approval
UL 1059
MKDS 5/...-6,35
MKDS 5/...-7,62
30 - 10 AWG
2
3
IEC 60664
MKDS 5/...-9,5
UL 1059
MKKDS 5/...-6,35
B
C
D
B
C
D
2
3
IEC 60664
MKKDS 5/...-9,5
UL 1059
4 mm
UL 1059
SMKDS 5/...-6,35
UL 1059
UL 1059
FRONT 4-6,35
600 VUL*
6 mm
UL 1059
600 VUL*
SPT 5/1-H/V-7,5
PHOENIX CONTACT
2
3
B
C
D
2
3
SPT 5 /...H/V-7,5-ZB
B
C
D
2
3
IEC 60664
2
24 - 8 AWG
MKDS 5 HV/...-ZB-6,35
IEC 60664
* The specified UL value is expected for the approval. The corresponding certification for this article is being prepared.
SMKDS 5/...-6,35
UL 1059/UL 508 (C)
250 V - 30 A
–
300 V - 10 A
IEC 60664
630 V - 32 A
500 V - 32 A
B
C
D
IEC 60664
FRONT 4-7,62
UL 1059
20
2
3
IEC 60664
ZFKDS 4-10
24 - 10 AWG
ZFKDS 4-7,5
B
C
D
IEC 60664
SMKDS 5/...-9,5
MKDS 5/...-6,35
UL 1059/UL 508 (C)
300 V - 30 A
–
300 V - 10 A
IEC 60664
630 V - 32 A
500 V - 32 A
MKKDS 5/...-6,35
UL 1059/UL 508 (C)
300 V - 30 A
–
300 V - 10 A
IEC 60664
630 V - 32 A
500 V - 32 A
2
3
IEC 60664
2
Conductor cross-section
MKDS 5 HV/...-9,52-Z
Linear
B
C
D
600 V UL
MKDS 5 HV/...-9,52
6.35 mm
B
C
D
2
3
FRONT 4 - 6,35
UL 1059/UL 508 (C)
250 V - 30 A
–
300 V - 10 A
IEC 60664
320 V - 32 A
320 V - 32 A
Pitch
6.35 mm
Z pinning
7.5 mm
Linear
7.62 mm
Z pinning
9.52 mm
Linear
Linear
MKDS 5/...-7,62
UL 1059/UL 508 (C)
300 V - 30 A
–
300 V - 10 A
IEC 60664
630 V - 32 A
500 V - 32 A
MKDS 5/...-9,5
UL 1059/UL 508 (C)
300 V - 30 A
300 V - 30 A
600 V - 5 A
IEC 60664
1,000 V - 32 A
690 V - 32 A
MKKDS 5/...-9,5
UL 1059/UL 508 (C)
300 V - 30 A
300 V - 30 A
600 V - 5 A
IEC 60664
1,000 V - 32 A
690 V - 32 A
MKDS 5 HV/...-9,52
UL 1059/UL 508 (C)
300 V - 30 A
300 V - 30 A
600 V - 5 A
IEC 60664/UL 840
1,000 V - 32 A 1)
800 V - 32 A 1)
SMKDS 5/...-9,5
UL 1059/UL 508 (C)
250 V - 30 A
300 V - 30 A
–
IEC 60664
1,000 V - 32 A
690 V - 32 A
ZFKDS 4-7,5
UL 1059/UL 508 (C)
300 V - 30 A
150 V - 30 A
300 V - 10 A
IEC 60664
630 V - 32 A
500 V - 32 A
10 mm
Z pinning
Linear
MKDS 5 HV/...-9,52-Z
UL 1059/UL 508 (C)
600 V - 30 A
600 V - 30 A
–
IEC 60664/UL 840
1,000 V - 32 A 1)
690 V - 32 A 1)
ZFKDS 4-10
UL 1059/UL 508 (C)
300 V - 30 A
300 V - 30 A
600 V - 5 A
IEC 60664
630 V - 32 A
630 V - 32 A
FRONT 4 -7,62
UL 1059/UL 508 (C)
250 V - 30 A
–
300 V - 10 A
IEC 60664
630 V - 32 A
500 V - 32 A
MKDS 5 HV/...-ZB-6,35
UL 1059/UL 508 (C)
600 V* - 30 A*
600 V* - 30 A*
–
IEC 60664 / UL 840
1,000 V - 41 A 1)
800 V - 41 A 1)
SPT 5/1-H/V-7,5
UL 1059/UL 508 (C)
300 V* - 35 A*
150 V* - 35 A*
600 V* - 5 A*
IEC 60664
1,000 V - 41 A
800 V - 41 A
SPT 5 /...H/V-7,5-ZB
UL 1059/UL 508 (C)
300 V* - 35 A*
600 V* - 35 A*
–
IEC 60664/UL 840
1,000 V - 41 A 2)
800 V - 41 A 2)
1)
Current value as per UL 840: 30 A
2)
Current value as per UL 840: 35 A
PHOENIX CONTACT
21
PCB terminal blocks
up to 25 mm2 conductor
cross-section
Pollution degree
Z pinning
Use Group
Linear pinning
Approval
24 - 6 AWG
UL 1059
600 V UL
ZFKDS 10-10
KDS 10(-PE)-SO
16 mm2
KDS 10(-PE)
B
C
D
2
3
IEC 60664
UL 1059
UL 1059
UL 1059
B
C
D
18 - 4 AWG
25 mm2
20 - 2 AWG
B
C
D
600 V
SPT 16/1-H/V-10,0
SPT 16/...-H/V-10,0-ZB
600 V UL
2
3
IEC 60664
UL 1059
B
C
D
2
3
* The specified UL value is expected for the approbation. The corresponding approval of this article is being prepared.
MKDSP 25/...-15,00(-F)
22
2
3
IEC 60664
UL 1059
PHOENIX CONTACT
IEC 60664
KDS 10(-PE)-SO
UL 1059/UL 508 (C)
250 V - 65 A
300 V - 65 A
600 V - 5 A
IEC 60664
630 V - 76 A
630 V - 76 A
2
3
600 V UL
MKDS 10 HV/...-ZB...-10,16
ZFKDS 10-10
UL 1059/UL 508 (C)
300 V - 65 A
150 V - 65 A
300 V - 10 A
IEC 60664
400 V - 76 A
320 V - 76 A
KDS 10(-PE)
UL 1059/UL 508 (C)
250 V - 65 A
300 V - 65 A
600 V - 5 A
IEC 60664
320 V - 76 A
250 V - 76 A
B
C
D
IEC 60664
MKDSP 10 HV/...-12,7
Z pinning
2
3
600 V UL
MKDSP 10 HV/...-10,16
Linear
B
C
D
IEC 60664
MKDSP 10/...-10,16
20 - 6 AWG
2
3
IEC 60664
ZFKDS 10-15
UL 1059
Conductor cross-section
B
C
D
10 mm
SPT 16/1-H/V-10,0
SPT 16/...-H/V-10,0-ZB
UL 1059/UL 508 (C)
300 V * - 66 A *
150 V * - 66 A *
300 V * - 10 A *
IEC 60664/UL 840
400 V - 76 A 3)
400 V - 76 A 3)
UL 1059/UL 508 (C)
600 V * - 66 A *
600 V * - 66 A *
–
IEC 60664 / UL 840
1,000 V - 76 A 3)
1,000 V - 76 A 3)
Pitch
10.16 mm
Linear
Z pinning
12.7 mm
15 mm
Linear
Linear
ZFKDS 10-15
UL 1059/UL 508 (C)
600 V - 65 A
600 V - 65 A
–
IEC 60664/UL 840
1,000 V - 76 A 1)
1,000 V - 76 A 1)
MKDSP 10/...-10,16
UL 1059/UL 508 (C)
300 V - 60 A
300 V - 60 A
600 V - 5 A
IEC 60664
1,000 V - 76 A
690 V - 76 A
MKDSP 10 HV/...-10,16
UL 1059/UL 508 (C)
300 V - 60 A
300 V - 60 A
600 V - 5 A
IEC 60664 / UL 840
1,000 V - 76 A 2)
690 V - 76 A 2)
MKDSP 10 HV/...-12,7
UL 1059/UL 508 (C)
600 V - 60 A
600 V - 60 A
–
IEC 60664/UL 840
1,000 V - 76 A 2)
1,000 V - 76 A 2)
www.select.phoenixcontact.com/combicon
The search engine
with CAD download
COMBICON Select supports your
workflow – from the PCB layout to
housing design through to the actual
order – by means of:
- Systematic and fast selection of
products for PCB terminal blocks,
connectors and electronic housings
- Integrated Internet-aided engineering
with an extensive CAD library
- Easy-to-use e-shopping functions
MKDS 10 HV/...-ZB-10,16
UL 1059/UL 508 (C)
600 V - 60 A
600 V - 60 A
–
IEC 60664/UL 840
1,000 V - 76 A 2)
800 V - 76 A 2)
MKDSP 25/...-15,00(-F)
UL 1059/UL 508 (C)
600 V - 115 A
600 V - 115 A
–
IEC 60664/UL 840
1,000 V - 125 A 4)
1,000 V - 125 A 4)
1)
Current value as per UL 840: 65 A
2)
Current value as per UL 840: 60 A
3)
Current value as per UL 840: 66 A
4)
Current value as per UL 840: 115 A
Four simple steps:
1. Enter the requirements
2. Select the product suggestion
3. View the data sheet and the drawings
4. Import the 2D or the 3D data
PHOENIX CONTACT
23
Further information on the products
introduced and the world of solutions from
Phoenix Contact can be found at
www.phoenixcontact.de/katalog
Industrial Connection Technology,
Marking Systems and Mounting Material
CLIPLINE
Industrial Connectors
PLUSCON
Or contact us directly!
PCB Connection Technology
and Electronic Housings
COMBICON
TRABTECH
Signal Converters, Switching Devices,
Power Supply Units
© PHOENIX CONTACT 2008
Surge Protection
AUTOMATION
PHOENIX CONTACT GmbH & Co. KG
D-32823 Blomberg, Germany
Phone: +49/5235/3-00
Fax
+49/5235/3-1 07 099
www.phoenixcontact.com
MNR 5127085/01.10.2008-06
Components and Systems
Printed in Germany
INTERFACE