LevelOne FSW-2470 24 10/100BASE-TX + 100Base

LevelOne
FSW-2470
24 10/100BASE-TX + 100Base-FX slot
Web smart Switch
User’s Guide
Rev.1.00-0505
FCC Warning
This Equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Contents
INTRODUCTION ..........................................................................................................1
Features....................................................................................................................1
Software Features.....................................................................................................2
Package Contents.....................................................................................................2
HARDWARE DESCRIPTION.......................................................................................4
Physical Dimension...................................................................................................4
Front Panel ...............................................................................................................4
LED Indicators...........................................................................................................5
Rear Panel ................................................................................................................5
Desktop Installation...................................................................................................6
Rack-mounted Installation.........................................................................................6
Power On ..................................................................................................................7
NETWORK APPLICATION..........................................................................................8
WEB MANAGEMENT ................................................................................................10
About Web-based Management .............................................................................10
Preparing for Web Management .............................................................................10
System Login ..........................................................................................................11
Port Status ..............................................................................................................12
Port Configuration ...................................................................................................14
VLAN Setting ..........................................................................................................15
Trunk Configuration.................................................................................................16
System Configuration..............................................................................................17
Firmware Update.....................................................................................................18
Change Password...................................................................................................19
TROUBLESHOOTING ...............................................................................................21
TECHNICAL SPECIFICATION ..................................................................................23
STEP BY STEP FIRMWARE UPGRADE…………………………………………………25
Introduction
The LevelOne FSW-2470, 24 10/100BASE-TX + 100Base-FX slot Web smart
Switch, is a multi-port Switch that can be used to build high-performance
switched workgroup networks. This switch is a store-and-forward device that
offers low latency for high-speed networking and allows the switch to
auto-learn and store source address in a 4K-entry MAC address table. The
switch is targeted at workgroup, department or backbone computing
environment.
Features
Conforms to IEEE 802.3, 802.3u and 802.3x
Equipped with one uplink 100Base-FX slot and default button
IEEE 802.3x flow control support
Flow control on full-duplex
Back pressure on half-duplex
Auto-MDIX on all ports
N-way Auto-Negotiation
Store-and-Forward switching architecture and no-blocking full wire speed
5Gbps switch back plane
4K-entry MAC address table
Support Port Based VLAN and Port trunk
Port Based priority supported
Embedded 1.25 Mbits memory buffer
19” rack mount design and internal power
1
Software Features
Management
Web interface management
Link speed, Link mode, Port disable/Enable,
Port configuration
Port Flow control disable/Enable, Port Auto
negotiation
VLAN
Class of Service
Port Based VLAN, VLAN entry up to 24 groups.
Support port based priority and per port provide 2
queues (high and low).
Support one trunk group and any 10/100TX port
Trunk
can be assigned as trunk member.
The maximum trunk member can up to 8 ports as
one trunk group.
Firmware Update
TFTP firmware upgrade
Package Contents
Unpack the contents of LevelOne FSW-2470 and verify them against the
checklist below.
1 X FSW-2470, 24 10/100BASE-TX + 100Base-FX slot Web smart Switch
Power Cord
Four Rubber Feet
User Manual
Rack mount kit
2
FSW-2470
Four Rubber Feet
User Manual
Rack-mounted Kit
Power Cord
Package Contents
Compare the contents of the Switch package with the standard checklist above.
If any item is missing or damaged, please contact your local dealer for service.
3
Hardware Description
This Section mainly describes the hardware of FSW-2470, 24 10/100BASE-TX
+ 100Base-FX slot Web smart Switch, and gives a physical and functional
overview of this Switch.
Physical Dimension
The physical dimension of LevelOne FSW-2470 is 440mm x 120mm x 44mm
(Lx W x H).
Front Panel
The Front Panel of the 24 10/100BASE-TX + 100Base-FX slot Web smart
Switch consists LED Indicators, 24 ports auto-negotiation 10/100Mbps
Ethernet RJ-45 connectors, one slot module and a default button.
RJ-45 Ports (Auto MDI/MDIX): 24 ports auto-negotiation 10/100 Mbps
Ethernet RJ-45 connectors
[Auto MDI/MDIX means that you can connect to another switch or workstation
without changing straight through or crossover cabling.]
Module (Optional): 1 port 100FX(SC) and 1 port 100FX(SC, 30Km)
module.
Reset Button: for system reset and factory default.
System reset: press 3 seconds and release.
Factory default: press 5 seconds and release.
The Front view of the 24 10/100BASE-TX + 100Base-FX slot Web smart Switch
4
LED Indicators
The LED Indicators gives real-time information of systematic operation status.
The following table provides descriptions of LED status and their meaning.
LED
Status
Description
Power
Green
Power On
(POW)
Off
Power is not connected
Green
The port is connecting with the device.
Blinks
The port is receiving or transmitting data.
Off
No device attached.
Amber
The port is operating in Full-duplex mode.
Blinks
Collision of Packets occurs in the port.
Off
In half-duplex mode
LK/ACT
FD/COL
The Description of LED Indicators
Rear Panel
The 3-pronged power plug is located at the rear Panel of the 24
10/100BASE-TX + 100Base-FX slot Web smart Switch. The Switch will work
with AC in the range 100-240V AC, 50-60Hz.
The Rear Panel of 24 10/100BASE-TX + 100Base-FX slot Web smart Switch
5
Desktop Installation
Set the Switch on a sufficiently large flat space with a power outlet nearby. The
surface where you put your Switch should be clean, smooth, level and sturdy.
Make sure there is enough clearance around the Switch to allow attachment of
cables, power cord and allow air circulation.
Attaching Rubber Feet
1.
Make sure mounting surface on the bottom of the Switch is grease and
dust free.
2.
Remove adhesive backing from your Rubber Feet.
3.
Apply the Rubber Feet to each corner on the bottom of the Switch. These
footpads can prevent the Switch from shock/vibration.
Rack-mounted Installation
The 24 10/100BASE-TX + 100Base-FX slot Web smart Switch comes with a
rack-mounted kit and can be mounted in an EIA standard size, 19-inch Rack.
The Switch can be placed in a wiring closet with other equipment. Perform the
following steps to rack mount the switch:
1.
Position one bracket to align with the holes on one side of the switch and
secure it with the smaller bracket screws. Then attach the remaining
bracket to the other side of the Switch.
2.
After attached mounting brackets, position the Switch in the rack by lining
up the holes in the brackets with the appropriate holes on the rack. Secure
the Switch to the rack with a screwdriver and the rack-mounting screws.
Note: For proper ventilation, allow about at least 4 inches (10 cm) of
clearance on the front and 3.4 inches (8 cm) on the back of the Switch.
This is especially important for enclosed rack installation.
6
Power On
Connect the power cord to the power socket on the rear panel of the Switch.
The other side of power cord connects to the power outlet. The internal power
supply of the Switch works with voltage range of AC in the 100-240VAC,
frequency 50~60Hz. Check the power indicator on the front panel to see if
power is properly supplied.
7
Network Application
This section provides you a few samples of network topology in witch the
Switch is used. In general, LevelOne FSW-2470 Web smart Switch is
designed as a segment switch. That is, with its address table (4k MAC address)
and high performance, it is ideal for interconnecting networking segments.
PC, workstations, and servers can communicate each other by directly
connecting with 24 10/100BASE-TX + 100Base-FX slot Web smart Switch.
The switch automatically learns nodes address, which are subsequently used
to filter and forward all traffic based on the destination address.
By using Uplink port, the Switch can connect with another switch or hub to
interconnect other small-switched workgroups to form a larger switched
network.
Small Workgroup
LevelOne FSW-2470 Web smart Switch can be used as a standalone switch to
which personal computers, server, printer server, are directly connect to form
small workgroup.
Segment Bridge
For enterprise networks where large data broadcasts are constantly processed,
this switch is an ideal solution for department users to connect to the corporate
backbone.
In the illustration below, two Ethernet switches with PCs, print server, and local
8
server attached, are both connect to the Switch. All the devices in this network
can communicate with each other through the Switch. Connecting servers to
the Switch allow other users to access the data on server.
9
Web Management
This section introduces the configuration and functions of the Web-Based
management.
About Web-based Management
Inside the CPU board of the switch exists an embedded HTML web site
residing in flash memory. It offers advanced management features and allow
users to manage the switch from anywhere on the network through a standard
browser such as Microsoft Internet Explorer.
The Web-Based Management supports Internet Explorer 5.0. It is based on
Java Applets with an aim to reduce network bandwidth consumption, enhance
access speed and present an easy viewing screen.
[Note] By default, IE5.0 or later version does not allow Java Applets to open
sockets. The user has to explicitly modify the browser setting to enable Java
Applets to use network ports.
Preparing for Web Management
The default value of the switch is as below:
IP Address: 192.168.16.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.16.254
User Name: root
Password: root
10
System Login
1.
Install the switch on your network.
2.
Launch the Internet Explorer.
3.
Type http:// and the IP address of the switch. Press “Enter”.
4.
The login screen appears.
Login Interface
5.
Key in the user name and password. The default user name “root” and
password “ root ”.
6.
Click ”OK”, then the home screen of the Web-based management
appears.
11
Home Interface
Port Status
In Port status function, you can view all ports current status.
Link Status: green means the port active. Gray means the port inactive.
Speed: the port transmitting speed.
Duplex: the port duplex mode.
Flow Control: the port flow control status.
12
Port Status interface
Select the port and click Counters
button, you can see the port counter
information as the following figure shown. Click
counters. Click
Cancel
Refresh
button to reset the
button will bring the screen back to previous page.
13
Port Counter Information Interface
Port Configuration
You can configure speed, status, flow control, duplex mode, port base priority,
port priority mapping and backpressure of each port. After configuration, click
Apply
button to apply the new configuration.
Advertise 10M Half: when auto negotiation is enabling, you can set up
the port speed is “On” or “Off”.
Advertise 10M Full: when auto negotiation is enabling, you can set up
the port speed is “On” or “Off”.
Advertise 100M Half: when auto negotiation is enabling, you can set up
the port speed is “On” or “Off”.
Advertise 100M Full: when auto negotiation is enabling, you can set up
the port speed is “On” or “Off”.
Full Duplex Flow Control: when auto negotiation is enabling, you can set
up the full duplex flow control status is “On” or “Off”.
14
Auto Negotiation: set up the auto negotiation status. “Enable” means the
port speed is auto negotiation and detect. The port speed has four modes
and can be configured at the same time. “Disable” means the auto
negotiation is in force status. You can configure the port speed in “Speed”
and “Duplex” selection.
Speed: set the port speed is 100M or 10M.
Duplex: set the port in full-duplex or half-duplex mode.
Port State: enable or disable the port function. “Close” means the port is
unusable. “Open” means the port is functional.
Port Priority Mapping: set the port priority level.
Back Pressure Support: enable or disable back pressure function.
Port configuration interface
VLAN Setting
The system supports 24 VLAN groups. Select the VLAN group # and port
member. Use
<<Add
button to add the VLAN group members and click
15
Apply
button to complete the VLAN configuration. Use
Remove>>
button to remove unwanted group members.
VLAN Setting Interface
Trunk Configuration
The system supports only one trunk group. The trunk group supports up to 8
port members. If the port members are more than 8, it will cause the system
abnormal. Mark the port number and click
setting.
16
Apply
button to apply the
Trunk Configuration interface
[Note] The trunk members must in the same VLAN group. Otherwise, the
trunk function will not operate.
System Configuration
You can configure the IP, subnet mask, and gateway. The firmware version
shown on the screen may vary with the factory firmware release period. Click
Submit
button to apply the new configuration.
17
System Configuration Interface
Firmware Update
You can update the latest firmware version.
1. Contact your switch vendor for the newest firmware.
2. After you got the new firmware, save in your local hard disk.
3. Go to Internet, search for the Bootp server utility and download it.
4. Install the Bootp server utility that you found.
5. Run the Bootp server utility and set the boot file direction to where the new
firmware is.
6. Go to the Firmware Update interface and click
Update
button to star
firmware loading.
7. After updated, please power off the switch and then power on the switch.
Please refer to page 25 fir step- by-step firmware upgrade instrunction.
18
Firmware Update Interface
Change Password
You can change the default username and password for the safety. The
username and password is 8 characters length and must use the
alphanumeric integer, characters or numbers. The system cannot recognize
the symbol other than numbers and characters. Enter the new username and
new password, click
Apply
button to apply the new username and
password.
19
Change Password Interface
20
Troubleshooting
This section is intended to help you solve the most common problems on the
FSW-2470 Web smart Switch.
Incorrect connections
The switch port can auto detect straight or crossover cable when you link
switch with other Ethernet device. For the RJ-45 connector should use correct
UTP or STP cable, 10/100Mbps port use 2 pairs twisted cable and Gigabit
1000T port use 4 pairs twisted cable. If the RJ-45 connector is not correct pin
on right position then the link will fail.
For fiber connection, please notice that
fiber cable mode and fiber module should be match.
Faulty or loose cables
Look for loose or obviously faulty connections. If they appear to be OK, make
sure the connections are snug. IF that does not correct the problem, try a
different cable.
Non-standard cables
Non-standard and miss-wired cables may cause numerous network collisions
and other network problem, and can seriously impair network performance. A
category 5-cable tester is a recommended tool for every 100Base-T network
installation.
Improper Network Topologies
It is important to make sure that you have a valid network topology. Common
topology faults include excessive cable length and too many repeaters (hubs)
21
between end nodes. In addition, you should make sure that your network
topology contains no data path loops. Between any two ends nodes, there
should be only one active cabling path at any time. Data path loops will cause
broadcast storms that will severely impact your network performance.
Diagnosing LED Indicators
The Switch can be easily monitored through panel indicators to assist in
identifying problems, which describes common problems you may encounter
and where you can find possible solutions.
If the power indicator does turn on when the power cord is plugged in, you may
have a problem with power outlet, or power cord. However, if the Switch
powers off after running for a while check for loose power connections, power
losses or surges at power outlet. If you still cannot resolve the problem, contact
your local dealer for assistance.
Cabling
RJ-45 ports: use unshielded twisted-pair (UTP) or shield twisted-pair ( STP )
cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10Mbps
connections or 100Ω Category 5 cable for 100Mbps connections. Also be
sure that the length of any twisted-pair connection does not exceed 100
meters (328 feet).
22
Technical Specification
This section provides the specifications of LevelOne FSW-2470,
24 10/100BASE-TX + 100Base-FX slot Web smart Switch.
IEEE 802.3 10BASE-T Ethernet,
Standard
IEEE 802.3u 100BASE-TX/100Base-FX
IEEE802.3x Flow Control and Back-pressure
Protocol
CSMA/CD
Technology
Store and forward switching architecture
Per unit: Power
LED Indicators
Per port: Link/Activity, Full duplex/Collision
Module: Link, Full-Duplex/Collision, TX, RX
Transfer Rate
14,880 pps Ethernet port,
148,800 pps Fast Ethernet port
10BASE-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
Network Cable
EIA/TIA-568 100-ohm (100m)
100BASE-TX: 2-pair UTP/STP Cat. 5 cable
EIA/TIA-568 100-ohm (100m)
Back-plane
5Gbps
MAC address
4K MAC address table
Memory
1.25Mbits
23
Default Button
System reset / Factory default
Power Supply
100-240 VAC, 50~60Hz, 3.3V/7A
Power
Consumption
15 Watt (max.)
Operation Temp.
0℃ to 45℃ (32℉ to 113℉)
Operation Humidity
10% to 90% (Non-condensing)
Storage Temp.
-10℃ to 70℃
Dimensions
440 mm (W) x 120 mm (D) x 44 mm (H)
EMI
FCC Class A, CE
Safety
UL, cUL, CE/EN60950
24
Step-by-Step firmware upgrade
This section will guide you through the firmware upgrde by using TFTP32.
(1) Copy the TFTP32 folder to the desktop of Windows and set this PC’s IP in same
subnet as FSW-2470 you would like to update.
(2) Copy the F/W Bin file to TFTP32 folder
25
(3) Execute tfptd32.exe then the PC will be a TFTP server
(4) Set TFTP DHCP server information:
1. IP pool starting addressÆ any free same subnet IP as TFTP server
2. Size of poolÆ any
3. Boot fileÆ full file name of the F/W Bin file
4. MaskÆ same as TFTP server
26
(5) Login to the web management of FSW-2470 then check the Firmware
Update page, click the “Update” button for F/W update.
(6) FSW-2470 ‘s F/W is being updating.
27
(7) Click the TFTP server tab to make sure F/W Bin file has been transmitted to
FSW-2470 completely then press the reset button of the switch 1 minute later.
(8) New F/W is updated successfully.
28