FVT-5001 / FVT-5301 / GVT-5000 Media Converter Module

FVT-5001 / FVT-5301 / GVT-5000
Copper to Fiber
Media Converter Module
User Manual
Part No.
Model
No.
532502
FVT-5001
10/100Base-TX to 100Base-FX
SC, Multi-mode 2km (TS-1000)
532530
FVT-5301
10/100Base-TX to 100Base-FX
SC, Single-mode 30km (TS-1000)
532500
GVT-5000
1000BaseT to SFP mini-GBIC
Converter Module
Description
Ver. 1.02 - 0701
FCC Warning
This Equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a class A product. In a domestic environment this product
may cause radio interference in which case the user may be
required to take adequate measures.
Table of Contents
1.
INTRODUCTION................................................ 1
1.1.
1.2.
1.3.
2.
HARDWARE DESCRIPTION ............................ 2
2.1.
2.2.
2.3.
3.
FRONT PANEL................................................. 2
FAST ETHERNET LED INDICATORS .................. 3
GIGABIT LED INDICATORS ............................... 4
INSTALLATION ................................................. 5
3.1.
3.2.
4.
FAST ETHERNET EXPENSION MODULE ............. 1
GIGABIT EXPENSION MODULE ......................... 1
PACKAGE CONTENTS ...................................... 2
CHASSIS ........................................................ 5
FIBER ............................................................. 6
SPECIFICATION................................................ 7
4.1.
4.2.
4.3.
OPTICAL FIBER ............................................... 7
OPTIONAL SFP MODULES ............................... 7
TECHNICAL SPECIFICATION ............................. 8
1.
Introduction
These converter modules are for FVT-5000 16 slot Converter
Chassis with TS-1000 supported. By this converter module, user
can get higher bandwidth from your network infrastructure and
extend network available link distance by fiber cable
1.1.
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Comply with IEEE 802.3, 802.3u standards
Convert between UTP cabling and Fiber-optic cabling
One RJ-45 connector, Auto-MDI/MDIX for UTP port
Support 10/100 Mbps Auto-negotiation for UTP port
Support TS-1000, Loop Back Test
Built in Link Lose Forwarding Technology
Remote Monitor/Control for Terminal side
Hot swappable
1.2.
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Fast Ethernet Expansion Module
Gigabit Expansion Module
Comply with IEEE 802.3, 802.3u, 802.3ab, 802.3z standards
Convert between UTP cabling and Fiber-optic cabling
One SFP slot for mini-GBIC module
One RJ-45 connector, Auto-MDI/MDIX for UTP port
Support 10/100/1000 Mbps Auto-negotiation for UTP port
Built in Link Lose Forwarding Technology
Remote Monitor/Control for Terminal side
Hot swappable
Note:
Gigabit Module does not support TS-1000
1
1.3.
-
Package Contents
Media Converter Module
User manual
If any item is damaged or missing, please contact your local dealer
for service.
2.
Hardware Description
2.1.
Front Panel
FVT-5001
FVT-5301
GVT-5000
2
2.2.
Fast Ethernet LED Indicators
LED
Status
Meaning
PWR
Green
Power on
SPD
(UTP)
Green
Link on 100Mbps Speed
LK/ACT
(UTP)
LK/ACT
(Fiber)
FDX/COL
(UTP)
FDX/COL
(Fiber)
OFF
Link on 10Mbps Speed
Green
The unit is linking with it’s link partner.
Blinks
The unit is transmitting or receiving packets
Off
No device attached
Green
The unit is linking with it’s link partner.
Blinks
The unit is transmitting or receiving packets
Off
No device attached
Orange
The UTP port is operating in full-duplex mode.
Blinks
Collision of Packets occurs in the port.
Off
Half-duplex mode or no device attached
Orange
The fiber port is operating in full-duplex mode.
Blinks
Collision of Packets occurs in the port.
Off
Half-duplex mode or no device attached
Link Lost Forwarding:
When LLF is enable, allow UTP link failures to be reported to the
fiber side and also allow Fiber link failure to be reported to the UTP
side. Therefore, A link loss forward feature is provided in both UTP
and Fiber side.
3
2.3.
Gigabit LED Indicators
LED
PWR
SPD
(UTP)
LK/ACT
(UTP)
LK/ACT
(Fiber)
FDX/COL
(UTP)
FDX/COL
(Fiber)
Status
Meaning
Green
Power on
Green
Link on 1000Mbps Speed
Orange
Link on 100Mbps Speed
OFF
Link on 10Mbps Speed
Green
The unit is linking with it’s link partner.
Blinks
The unit is transmitting or receiving packets
Off
No device attached
Green
The unit is linking with it’s link partner.
Blinks
The unit is transmitting or receiving packets
Off
No device attached
Orange
The UTP port is operating in full-duplex mode.
Blinks
Collision of Packets occurs in the port.
Off
Half-duplex mode or no device attached
Orange
The fiber port is operating in full-duplex mode.
Blinks
Collision of Packets occurs in the port.
Off
Half-duplex mode or no device attached
4
3.
Installation
3.1.
Chassis
This installation is only for mounting in converter chassis converter
module. You can follow the steps below to install modular
converters.
Remove the module slot cover from the converter chassis.
Install the modular converter by inserting it into the guides and
sliding it in, and then, press it firmly until the power plug in the
chassis plugs into the modular converter receptacle property.
Push the thumbscrews in and turn clockwise to tighten.
Do not over tighten the thumbscrews.
Front Panel with all modules installed
5
3.2.
Fiber
For the Fast Ethernet Fiber Port: We provide SC connectors
(multi/single mode). Please follow the below figure to connect it.
Wrong connection will cause the port cannot work properly.
ATTENTION
This is a Class 1 Laser/LED product
Do not stare into the Laser/LED beam
6
4.
Specification
4.1.
Optical Fiber
Wavelength
(nm)
Avg. Launch
Power (dB)
Avg.
Sensitivity (dB)
FVT-5001
SC, Multi-mode
1310 (nm)
-18 (dB)
-30 (dB)
FVT-5301
SC, Single-mode
1310 (nm)
-6 (dB)
-34 (dB)
Model No.
Model No.
Avg. Power
Loss Budget
(dBm)
Max. FDX Fiber
Fiber Size (um)
Distance (Km)
FVT-5001
SC, Multi-mode
12 (dBm)
2 (Km)
62.5/125
50/125
FVT-5301
SC, Single-mode
28 (dBm)
30(Km)
10/125
8/125
4.2.
Optional SFP Modules
GVT-5000 supports 3.3V mini-GBIC module
Part No.
Model No.
Description
570622
GVT-0300
Mini-GBIC SFP transceiver
Multi-Mode, 550m
551071
GVT-0301
Mini-GBIC SFP transceiver
Single-Mode, 10km
551072
GVT-0302
Mini-GBIC SFP transceiver
Single-Mode, 70km
7
4.3.
Technical Specification
Fast Ethernet Module
Standard
IEEE802.3 10Base-T
IEEE802.3u 100Base-TX/100Base-FX
IEEE802.3x Flow Control and Back pressure
TS-1000 Supported
Connector
Fiber: Duplex SC
RJ-45 Socket: 10/100Mbps
Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation
Switch
architecture
Store and Forward
Fiber Core:
Fiber
parameters
Multi-Mode (62.5/125um, 50/125um)
Single-Mode (8/125um, 10/125um)
Wavelength: 1310nm(Multi-mode)
1310nm(Single-mode)
Fiber Distance:
Multi-Mode Fiber 2KM
Single-Mode Fiber 30KM
Transparent
packet
68 to 1522Bytes
Link Lost
Forward
UTPÎFiber:
If UTP port link down, then converter will
forced fiber to link down.
Fiber Î UTP: If Fiber port link down, the media converter
will force UTP port to link down.
LED
Power, UTP (SPD, LK/ACT, FDX/COL)
Fiber (LK/ACT, FDX/COL)
Operation
Temp.
Storage
Temp.
Operation
Humidity
EMI & safety
0℃ to 45℃ (32℉ to 113℉)
-10℃ to 70℃
10% to 90% (Non-condensing)
CE, FCC Class A
8
Gigabit Ethernet Module
Standard
IEEE802.3ab 1000Base-T
IEEE802.3z 1000Base-SX/LX
IEEE802.3x Flow Control and Back pressure
Connector
Fiber: SFP Slot, 3.3V
RJ-45 Socket: 10/100/1000Mbps
Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation
Switch
architecture
Store and Forward
Fiber
parameters
Fiber Core:
Multi-Mode (62.5/125um, 50/125um)
Single-Mode (8/125um, 10/125um)
Wavelength: 850nm(Multi-mode)
1310nm(Single-mode)
Fiber Distance:
Depend on mini-GBIC transceiver type
Transparent
packet
68 to 1522Bytes
LED
Power, UTP (SPD, LK/ACT, FDX/COL)
Fiber (LK/ACT, FDX/COL)
Operation
Temp.
Storage
Temp.
Operation
Humidity
EMI & safety
0℃ to 45℃ (32℉ to 113℉)
-10℃ to 70℃
10% to 90% (Non-condensing)
CE, FCC Class A
9