FVT-5001 / FVT-5301 / GVT-5000 Copper to Fiber Media Converter Module User Manual Part No. Model No. 532502 FVT-5001 10/100Base-TX to 100Base-FX SC, Multi-mode 2km (TS-1000) 532530 FVT-5301 10/100Base-TX to 100Base-FX SC, Single-mode 30km (TS-1000) 532500 GVT-5000 1000BaseT to SFP mini-GBIC Converter Module Description Ver. 1.02 - 0701 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. CE Mark Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Table of Contents 1. INTRODUCTION................................................ 1 1.1. 1.2. 1.3. 2. HARDWARE DESCRIPTION ............................ 2 2.1. 2.2. 2.3. 3. FRONT PANEL................................................. 2 FAST ETHERNET LED INDICATORS .................. 3 GIGABIT LED INDICATORS ............................... 4 INSTALLATION ................................................. 5 3.1. 3.2. 4. FAST ETHERNET EXPENSION MODULE ............. 1 GIGABIT EXPENSION MODULE ......................... 1 PACKAGE CONTENTS ...................................... 2 CHASSIS ........................................................ 5 FIBER ............................................................. 6 SPECIFICATION................................................ 7 4.1. 4.2. 4.3. OPTICAL FIBER ............................................... 7 OPTIONAL SFP MODULES ............................... 7 TECHNICAL SPECIFICATION ............................. 8 1. Introduction These converter modules are for FVT-5000 16 slot Converter Chassis with TS-1000 supported. By this converter module, user can get higher bandwidth from your network infrastructure and extend network available link distance by fiber cable 1.1. Comply with IEEE 802.3, 802.3u standards Convert between UTP cabling and Fiber-optic cabling One RJ-45 connector, Auto-MDI/MDIX for UTP port Support 10/100 Mbps Auto-negotiation for UTP port Support TS-1000, Loop Back Test Built in Link Lose Forwarding Technology Remote Monitor/Control for Terminal side Hot swappable 1.2. Fast Ethernet Expansion Module Gigabit Expansion Module Comply with IEEE 802.3, 802.3u, 802.3ab, 802.3z standards Convert between UTP cabling and Fiber-optic cabling One SFP slot for mini-GBIC module One RJ-45 connector, Auto-MDI/MDIX for UTP port Support 10/100/1000 Mbps Auto-negotiation for UTP port Built in Link Lose Forwarding Technology Remote Monitor/Control for Terminal side Hot swappable Note: Gigabit Module does not support TS-1000 1 1.3. - Package Contents Media Converter Module User manual If any item is damaged or missing, please contact your local dealer for service. 2. Hardware Description 2.1. Front Panel FVT-5001 FVT-5301 GVT-5000 2 2.2. Fast Ethernet LED Indicators LED Status Meaning PWR Green Power on SPD (UTP) Green Link on 100Mbps Speed LK/ACT (UTP) LK/ACT (Fiber) FDX/COL (UTP) FDX/COL (Fiber) OFF Link on 10Mbps Speed Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Orange The UTP port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached Orange The fiber port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached Link Lost Forwarding: When LLF is enable, allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side. Therefore, A link loss forward feature is provided in both UTP and Fiber side. 3 2.3. Gigabit LED Indicators LED PWR SPD (UTP) LK/ACT (UTP) LK/ACT (Fiber) FDX/COL (UTP) FDX/COL (Fiber) Status Meaning Green Power on Green Link on 1000Mbps Speed Orange Link on 100Mbps Speed OFF Link on 10Mbps Speed Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Orange The UTP port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached Orange The fiber port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached 4 3. Installation 3.1. Chassis This installation is only for mounting in converter chassis converter module. You can follow the steps below to install modular converters. Remove the module slot cover from the converter chassis. Install the modular converter by inserting it into the guides and sliding it in, and then, press it firmly until the power plug in the chassis plugs into the modular converter receptacle property. Push the thumbscrews in and turn clockwise to tighten. Do not over tighten the thumbscrews. Front Panel with all modules installed 5 3.2. Fiber For the Fast Ethernet Fiber Port: We provide SC connectors (multi/single mode). Please follow the below figure to connect it. Wrong connection will cause the port cannot work properly. ATTENTION This is a Class 1 Laser/LED product Do not stare into the Laser/LED beam 6 4. Specification 4.1. Optical Fiber Wavelength (nm) Avg. Launch Power (dB) Avg. Sensitivity (dB) FVT-5001 SC, Multi-mode 1310 (nm) -18 (dB) -30 (dB) FVT-5301 SC, Single-mode 1310 (nm) -6 (dB) -34 (dB) Model No. Model No. Avg. Power Loss Budget (dBm) Max. FDX Fiber Fiber Size (um) Distance (Km) FVT-5001 SC, Multi-mode 12 (dBm) 2 (Km) 62.5/125 50/125 FVT-5301 SC, Single-mode 28 (dBm) 30(Km) 10/125 8/125 4.2. Optional SFP Modules GVT-5000 supports 3.3V mini-GBIC module Part No. Model No. Description 570622 GVT-0300 Mini-GBIC SFP transceiver Multi-Mode, 550m 551071 GVT-0301 Mini-GBIC SFP transceiver Single-Mode, 10km 551072 GVT-0302 Mini-GBIC SFP transceiver Single-Mode, 70km 7 4.3. Technical Specification Fast Ethernet Module Standard IEEE802.3 10Base-T IEEE802.3u 100Base-TX/100Base-FX IEEE802.3x Flow Control and Back pressure TS-1000 Supported Connector Fiber: Duplex SC RJ-45 Socket: 10/100Mbps Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation Switch architecture Store and Forward Fiber Core: Fiber parameters Multi-Mode (62.5/125um, 50/125um) Single-Mode (8/125um, 10/125um) Wavelength: 1310nm(Multi-mode) 1310nm(Single-mode) Fiber Distance: Multi-Mode Fiber 2KM Single-Mode Fiber 30KM Transparent packet 68 to 1522Bytes Link Lost Forward UTPÎFiber: If UTP port link down, then converter will forced fiber to link down. Fiber Î UTP: If Fiber port link down, the media converter will force UTP port to link down. LED Power, UTP (SPD, LK/ACT, FDX/COL) Fiber (LK/ACT, FDX/COL) Operation Temp. Storage Temp. Operation Humidity EMI & safety 0℃ to 45℃ (32℉ to 113℉) -10℃ to 70℃ 10% to 90% (Non-condensing) CE, FCC Class A 8 Gigabit Ethernet Module Standard IEEE802.3ab 1000Base-T IEEE802.3z 1000Base-SX/LX IEEE802.3x Flow Control and Back pressure Connector Fiber: SFP Slot, 3.3V RJ-45 Socket: 10/100/1000Mbps Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation Switch architecture Store and Forward Fiber parameters Fiber Core: Multi-Mode (62.5/125um, 50/125um) Single-Mode (8/125um, 10/125um) Wavelength: 850nm(Multi-mode) 1310nm(Single-mode) Fiber Distance: Depend on mini-GBIC transceiver type Transparent packet 68 to 1522Bytes LED Power, UTP (SPD, LK/ACT, FDX/COL) Fiber (LK/ACT, FDX/COL) Operation Temp. Storage Temp. Operation Humidity EMI & safety 0℃ to 45℃ (32℉ to 113℉) -10℃ to 70℃ 10% to 90% (Non-condensing) CE, FCC Class A 9