FVT-6001 / FVT-6301 Copper to Fiber Smart Media Converter User Manual Part No. Model No. 532602 FVT-6001 10/100Base-TX to 100Base-FX SC, Multi-mode 2km (TS-1000) 532630 FVT-6301 10/100Base-TX to 100Base-FX SC, Single-mode 30km (TS-1000) Description Ver. 1.00 - 0611 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. CE Mark Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Table of Contents 1. INTRODUCTION................................................1 1.1. 1.2. 2. HARDWARE DESCRIPTION ............................ 2 2.1. 2.2. 2.3. 2.4. 3. FRONT PANEL.................................................2 REAR PANEL ..................................................2 LED INDICATORS ............................................3 DIP-SWITCH ...................................................4 CONNECTION ...................................................5 3.1. 3.2. 3.3. 4. FEATURES ......................................................1 PACKAGE CONTENTS ......................................2 CABLING ........................................................5 RJ-45 PORT ...................................................5 FIBER .............................................................6 SPECIFICATION................................................7 4.1. 4.2. OPTICAL FIBER ...............................................7 TECHNICAL SPECIFICATION ............................. 8 1. Introduction The LevelOne 10/100 TX to 100FX Media Converter is a cost-effective solution for the converting between 10/100Base-TX and 100Base-FX cabling, it allows you to extend the cabling distance of your 100Base-FX network. The 10/100 TX to 100FX Media Converter provides cabling connectors: SC multi- mode fiber connector and SC single-mode fiber connector. There are 4 DIPswitches to set the operation mode for UTP, Fiber ports and link loss forwarding function. With TS1000 compliant, it supports alarm output, display and loop-back test functions simplify maintenance and fault isolation tasks The 10/100 TX to 100FX Media Converter can be slotted in FVT-4000 Multi-Converter Chassis, which allows your network connectivity to be more flexible. It also can be use as stand-alone without slot in Multi-Converter Chassis. The package has included the AC power adaptor for stand-alone using. 1.1. Features Comply with IEEE 802.3, 802.3u, and 802.3x standards Convert between UTP cabling and Fiber-optic Support 10/100 Mbps Auto-negotiation for UTP port SC Fiber cabling connectivity up to 30Km Store-and-forward switching to separate two collision domains Link- Lost-Forwarding function 4DIP-switches to set the operation mode Standalone and Chassis design Support TS-1000 for CPE side 1 1.2. - Package Contents FVT-6001 / FVT-6301 Media Converter Power Adaptor DC 9V, 0.7A User manual Compare the contents of your converter module with the checklist above. If any item is damaged or missing, please contact your local dealer for service. 2. Hardware Description 2.1. Front Panel 1 (1) RJ-45 Port (2) LED 2.2. 2 3 (3) DIP-Switch (4) SC Fiber Connector Rear Panel Power Adapter: DC 9V, 0.7A 2 4 The rear panel contains a power socket. This power socket accepts DC9V voltage and minimum 0.7A supplied current. 2.3. LED Indicators LED PWR 100 LK/ACT (UTP) LK/ACT (Fiber) FDX/COL (UTP) FDX/COL (Fiber) Status Meaning Green Power on Green 100Mbps UTP Speed OFF 10 Mbps UTP Speed Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Orange The UTP port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached Orange The fiber port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached 3 2.4. DIP-switch The DIP-switch is used to configure operation mode for LLF (Link Lost Forwarding) and operation mode for UTP/Fiber port. The default value of DIPswitch is OFF. No 1 2 3 4 Status ON OFF ON OFF ON OFF ON OFF Description UTP 100Mbps Full Duplex mode UTP Auto-Nego Fiber in Half Duplex Fiber in Full Duplex LLF Enable LLF Disable Pure converter mode Switch Converter mode Link Lost Forwarding: When LLF is enable, allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side. Therefore, A link loss forward feature is provided in both UTP and Fiber side. Pure Converter mode (Fast Ethernet Module): When pure converter mode is enabling (on), it operates with the minimum latency. The transmission flow does not wait until entire frame is ready, but instead it forwards the received data immediately after the data being received. And TP port should be forced at 100M in this application. When DIP-Switch is in Switch Converter mode (off), the converter function is same as Switch Hub. Note: Please don’t change the DIP-switch setting when UTP or fiber port is transmitting or receiving data. It may cause some data error. 4 3. Connection 3.1. Cabling Twisted-pair segment can be use unshielded twisted pair (UTP) or shielded twisted pair (STP) cabling. The cable must comply with the IEEE 802.3u 100Base TX standard for Category 5. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long. Fiber segment using multi-mode connector type must use 50 or 62.5/125 um multi-mode fiber cable. You can connect two devices up to a 2-kilometer (6,562 ft.) distance. Fiber segment using single-mode connector type must use 8/125 or 9/125 um single-mode fiber cable. You can connect two devices in the distance of 30 Kilometers in full duplex operation. For half-duplex operation, the recommended maximum distance is 412 meters (1,352 ft.) 3.2. RJ-45 Port RJ-45 Port (Auto MDI/MDIX): the Ethernet RJ-45 will auto-sense for 10Base-T or 100Base-TX connections. Auto MDI/MDIX means that you can connect to another Switch or workstation without changing non-crossover or crossover cabling. See the below figures for straight through and crossover cable schematic. Pin Number Assignment 1 Tx+ 2 Tx3 Rx+ 6 RxRJ-45 Pin Assignments [Note] “+” and “-” signs represent the polarity of the wires that make up each wire pair. 5 3.3. Fiber Fiber Port: It is a 100 Base-FX connection. We provide SC connectors (multi/single mode). Please follow the below figure to connect it. Wrong connection will cause the port cannot work properly. ATTENTION This is a Class 1 Laser/LED product Do not stare into the Laser/LED beam 6 4. Specification 4.1. Optical Fiber Wavelength (nm) Avg. Launch Power (dB) Avg. Sensitivity (dB) FVT-6001 SC, Multi-mode 1310 (nm) -18 (dB) -30 (dB) FVT-6301 SC, Single-mode 1310 (nm) -6 (dB) -34 (dB) Model No. Model No. Avg. Power Loss Budget (dBm) Max. FDX Fiber Fiber Size (um) Distance (Km) FVT-6001 SC, Multi-mode 12 (dBm) 2 (Km) 62.5/125 50/125 FVT-6301 SC, Single-mode 28 (dBm) 30(Km) 10/125 8/125 7 4.2. Technical Specification Standard Connector Switch architecture IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX/100BASE-FX IEEE802.3x Flow Control and Back pressure Fiber: Duplex SC RJ-45 Socket: CAT-3/5 (10/100Mbps) Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation Store and Forward Fiber Core: Fiber parameters Transparent packet Link Lost Forward DIP Switch LED Power Dimension Operation Temp. Storage Temp. Operation Humidity EMI & safety Multi-Mode (62.5/125um, 50/125um) Single-Mode (8/125um, 10/125um) Wavelength: 1310nm(Multi-mode) 1310nm(Single-mode) Fiber Distance: Multi-Mode Fiber 2KM Single-Mode Fiber 30KM 64 to 1536 packet size (Maximum) 64 to 1518Bytes for Non-VLAN Ethernet packet 68 to 1522Bytes for Tag-VLAN packet. UTPÎFiber: If UTP port link down, then converter will forced fiber to link down. Fiber Î UTP: If Fiber port link down, the media converter will force UTP port to link down. DIP Switch 1: UTP Auto-Nego/100Mbps Full Duplex mode DIP Switch 2: Fiber Full/Half Duplex DIP Switch 3: LLF (Link Lose Forwarding) Disable/Enable DIP Switch 4: Switch Converter / Pure converter mode Power, UTP (100Mbps, LK/ACT, FDX/COL) Fiber (LK/ACT, FDX/COL) DC9V / 0.7A 119mm x 85mm x 26mm 0℃ to 45℃ (32℉ to 113℉) -10℃ to 70℃ 10% to 90% (Non-condensing) CE, FCC Class A 8