3030-10 HiTESTER Field Measuring Instruments Tough and Reliable multimeter Only from p o r D roof! p ! e f Sa o t y s Ea se ! u Rugged and easy to use, this meter can withstand a 1 meter drop onto a concrete floor. The 3030-10 has enhanced safety features and complies with a wide range of safety standards. HIOKI has long experience in the analog tester market, and now brings to it enhanced safety and usability. e ith thds: w s e ar pli Com ing stand follow 0 1 0 1 IEC C EM 60 years of Technology and Reliability ● Drop-proof design allows meter to withstand a 1m drop onto a concrete floor. ● Protected against transient voltages up to 250 V AC, preventing electric shock accidents before they can happen The internal circuit protects the resistance and milliamp ranges against transient voltages up to 250 V AC, preventing electric shock accidents before they can happen. Even in the event of an internal short-circuit, a current-limiting resistor is provided, to restrict shortcircuit currents. ● LED check function Visual check function available to confirm the LED light emission. ● Battery check function Battery level can be checked even when a real load is applied. ● Temperature measurement support (with optional probes) ● CE marking Assured for safe use by anyone, anywhere in the world. Carrying handle of the supplied case becomes a stand. ■Specification Item Max. scale reading Tolerance DC voltage 0.3/3/12/30/120/ 300/600V Notes ±2.5% of full scale 20 kΩ (16.7 kΩ in 0.3 V range) AC voltage 12/30/120/300/ 600V ±2.5% of full scale 9 kΩ/V (12 V ±4%) DC current 60µ/30/300mA ±3% of full scale Internal voltage drop 300 mV Resistance 3k/30k/300k/3MΩ ±3% of scale length Internal voltage 3 V Temperature −50 ∼ 150˚C scale ±3% of scale length With optional temperature measurement probes Battery check 0.9 ∼ 1.8V ±6% of scale length Load resistance 10 Ω LED check Yes Safety standards IEC 61010, CAT III 600V Batteries R6P/AA × 2 Dimensions 95(W) × 141(H) × 39(D) , approx. 280g 3030-10 HiTESTER (Supplied with 9207 test leads and 9390 carrying case) Options 9021-01 Thermister Temperature Probe * 9005-01 Clamp on Probe * 9017 High-Voltage Probe * These products are not CE-marked. 9021-01 Notes on measuring power line. DANGER Accessories 9207 Test Leads (1 set); 9390 Carrying Case (1) Before taking a measurement, check the position of the range switch. Do not measure voltage outside the set voltage range or voltage at levels in excess of the measurement limit. Doing so may damage the unit or cause an accident resulting in injury or death. Do not input voltage to the current measurement, resistance measurement, and battery test ranges. Doing so may damage the unit or cause an accident resulting in injury or death. NOTE: Protective system: The Ω and mA ranges are protected up to 250 VAC commercial power input and Meter overload protection. DISTRIBUTED BY HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@ hiokiusa.com Shanghai Representative Office : 1704 Shanghai Times Square Office 93 Huaihai Zhong Road Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: [email protected] All information correct as of May. 20, 2004. All specifications are subject to change without notice. 303010E3-45M-03K Printed in Japan