EN29LV320B EN29LV320B 32 Megabit (4096K x 8-bit / 2048K x 16-bit) Flash Memory Boot Sector Flash Memory, CMOS 3.0 Volt-only FEATURES • Single power supply operation - Full voltage range: 2.7 to 3.6 volts read and write operations • High performance - Access times as fast as 70 ns • Low power consumption (typical values at 5 MHz) - 9 mA typical active read current - 20 mA typical program/erase current - Less than 1 µA current in standby or automatic sleep mode • Flexible Sector Architecture: - Eight 8-Kbyte sectors, sixty-three 64k-byte sectors - 8-Kbyte sectors for Top or Bottom boot - Sector/Sector Group protection: Hardware locking of sectors to prevent program or erase operations within individual sectors Additionally, temporary Sector Group Unprotect allows code changes in previously locked sectors • - High performance program/erase speed Word program time: 8µs typical Sector erase time: 100ms typical Chip erase time: 8s typical • JEDEC Standard compatible • Standard DATA# polling and toggle bits feature • Erase Suspend / Resume modes: Read and program another Sector during Erase Suspend Mode • Support JEDEC Common Flash Interface (CFI). • Low Vcc write inhibit < 2.5V • Minimum 100K program/erase endurance cycles • RESET# hardware reset pin - Hardware method to reset the device to read mode • WP#/ACC input pin - Write Protect (WP#) function allows protection of outermost two boot sectors, regardless of sector protect status - Acceleration (ACC) function provides accelerated program times • Package Options - 48-pin TSOP (Type 1) - 48 ball 6mm x 8mm TFBGA • Industrial Temperature Range GENERAL DESCRIPTION The EN29LV320B is a 32-Megabit, electrically erasable, read/write non-volatile flash memory, organized as 4,194,304 bytes or 2.097,152 words. Any word can be programmed typically in 8µs. The EN29LV320B features 3.0V voltage read and write operation, with access times as fast as 70ns to eliminate the need for WAIT states in high-performance microprocessor systems. The EN29LV320B has separate Output Enable (OE#), Chip Enable (CE#), and Write Enable (WE#) controls, which eliminate bus contention issues. This device is designed to allow either single Sector or full Chip erase operation, where each Sector can be individually protected against program/erase operations or temporarily unprotected to erase or program. The device can sustain a minimum of 100K program/erase cycles on each Sector. . This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 1 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B CONNECTION DIAGRAMS TFBGA Top View, Balls Facing Down A6 A13 A5 A9 B6 A12 B5 A8 A4 B4 WE# RESET# A3 B3 RY/BY# WP# /ACC A2 B2 A7 A17 A1 B1 A3 A4 C6 A14 C5 A10 C4 NC C3 A18 C2 A6 C1 A2 D6 A15 D5 A11 E6 A16 E5 DQ7 F6 BYTE# F5 DQ14 G6 DQ15/A-1 G5 DQ13 H6 Vss H5 DQ6 D4 E4 F4 G4 H4 A19 DQ5 DQ12 Vcc DQ4 D3 E3 F3 G3 H3 A20 DQ2 DQ10 DQ11 DQ3 D2 E2 F2 G2 H2 A5 DQ0 DQ8 DQ9 DQ1 D1 E1 F1 G1 H1 A1 A0 CE# OE# Vss This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 2 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B TABLE 1. PIN DESCRIPTION LOGIC DIAGRAM Pin Name Function A0-A20 21 Address inputs DQ0-DQ14 15 Data Inputs/Outputs A0 – A20 DQ15 / A-1 DQ15 (data input/output, in word mode), A-1 (LSB address input, in byte mode) WP#/ACC CE# Chip Enable RESET# OE# Output Enable OE# WE# Write Enable WP#/ACC Write Protect / Acceleration Pin RESET# Hardware Reset Pin BYTE# Byte/Word mode selection RY/BY# Ready/Busy Output Vcc Supply Voltage (2.7-3.6V) Vss Ground NC Not Connected to anything EN29 LV320 DQ0 – DQ15 (A-1) CE# WE# BYTE# RY/BY# This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 3 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Table 2A. Top Boot Sector Address Tables (EN29LV320BT) Sector A20 – A12 Sector Size (Kbytes / Kwords) Address Range (h) Byte mode (x8) Address Range (h) Word Mode (x16) SA0 000000xxx 64/32 000000–00FFFF 000000–007FFF SA1 000001xxx 64/32 010000–01FFFF 008000–00FFFF SA2 000010xxx 64/32 020000–02FFFF 010000–017FFF SA3 000011xxx 64/32 030000–03FFFF 018000–01FFFF SA4 000100xxx 64/32 040000–04FFFF 020000–027FFF SA5 000101xxx 64/32 050000–05FFFF 028000–02FFFF SA6 000110xxx 64/32 060000–06FFFF 030000–037FFF SA7 000111xxx 64/32 070000–07FFFF 038000–03FFFF SA8 001000xxx 64/32 080000–08FFFF 040000–047FFF SA9 001001xxx 64/32 090000–09FFFF 048000–04FFFF SA10 001010xxx 64/32 0A0000–0AFFFF 050000–057FFF SA11 001011xxx 64/32 0B0000–0BFFFF 058000–05FFFF SA12 001100xxx 64/32 0C0000–0CFFFF 060000–067FFF SA13 001101xxx 64/32 0D0000–0DFFFF 068000–06FFFF SA14 001110xxx 64/32 0E0000–0EFFFF 070000–077FFF SA15 001111xxx 64/32 0F0000–0FFFFF 078000–07FFFF SA16 010000xxx 64/32 100000–10FFFF 080000–087FFF SA17 010001xxx 64/32 110000–11FFFF 088000–08FFFF SA18 010010xxx 64/32 120000–12FFFF 090000–097FFF SA19 010011xxx 64/32 130000–13FFFF 098000–09FFFF SA20 010100xxx 64/32 140000–14FFFF 0A0000–0A7FFF SA21 010101xxx 64/32 150000–15FFFF 0A8000–0AFFFF SA22 010110xxx 64/32 160000–16FFFF 0B0000–0B7FFF SA23 010111xxx 64/32 170000–17FFFF 0B8000–0BFFFF SA24 011000xxx 64/32 180000–18FFFF 0C0000–0C7FFF SA25 011001xxx 64/32 190000–19FFFF 0C8000–0CFFFF SA26 011010xxx 64/32 1A0000–1AFFFF 0D0000–0D7FFF SA27 011011xxx 64/32 1B0000–1BFFFF 0D8000–0DFFFF SA28 011100xxx 64/32 1C0000–1CFFFF 0E0000–0E7FFF SA29 011101xxx 64/32 1D0000–1DFFFF 0E8000–0EFFFF SA30 011110xxx 64/32 1E0000–1EFFFF 0F0000–0F7FFF SA31 011111xxx 64/32 1F0000–1FFFFF 0F8000–0FFFFF SA32 100000xxx 64/32 200000–20FFFF 100000–107FFF SA33 100001xxx 64/32 210000–21FFFF 108000–10FFFF SA34 100010xxx 64/32 220000–22FFFF 110000–117FFF SA35 100011xxx 64/32 230000–23FFFF 118000–11FFFF SA36 100100xxx 64/32 240000–24FFFF 120000–127FFF SA37 100101xxx 64/32 250000–25FFFF 128000–12FFFF SA38 100110xxx 64/32 260000–26FFFF 130000–137FFF SA39 100111xxx 64/32 270000–27FFFF 138000–13FFFF This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 4 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B SA40 101000xxx 64/32 280000–28FFFF 140000–147FFF SA41 101001xxx 64/32 290000–29FFFF 148000–14FFFF SA42 101010xxx 64/32 2A0000–2AFFFF 150000–157FFF SA43 101011xxx 64/32 2B0000–2BFFFF 158000–15FFFF SA44 101100xxx 64/32 2C0000–2CFFFF 160000–167FFF SA45 101101xxx 64/32 2D0000–2DFFFF 168000–16FFFF SA46 101110xxx 64/32 2E0000–2EFFFF 170000–177FFF SA47 101111xxx 64/32 2F0000–2FFFFF 178000–17FFFF SA48 110000xxx 64/32 300000–30FFFF 180000–187FFF SA49 110001xxx 64/32 310000–31FFFF 188000–18FFFF SA50 110010xxx 64/32 320000–32FFFF 190000–197FFF SA51 110011xxx 64/32 330000–33FFFF 198000–19FFFF SA52 110100xxx 64/32 340000–34FFFF 1A0000–1A7FFF SA53 110101xxx 64/32 350000–35FFFF 1A8000–1AFFFF SA54 110110xxx 64/32 360000–36FFFF 1B0000–1B7FFF SA55 110111xxx 64/32 370000–37FFFF 1B8000–1BFFFF SA56 111000xxx 64/32 380000–38FFFF 1C0000–1C7FFF SA57 111001xxx 64/32 390000–39FFFF 1C8000–1CFFFF SA58 111010xxx 64/32 3A0000–3AFFFF 1D0000–1D7FFF SA59 111011xxx 64/32 3B0000–3BFFFF 1D8000–1DFFFF SA60 111100xxx 64/32 3C0000–3CFFFF 1E0000–1E7FFF SA61 111101xxx 64/32 3D0000–3DFFFF 1E8000–1EFFFF SA62 111110xxx 64/32 3E0000–3EFFFF 1F0000–1F7FFF SA63 111111000 8/4 3F0000–3F1FFF 1F8000–1F8FFF SA64 111111001 8/4 3F2000–3F3FFF 1F9000–1F9FFF SA65 111111010 8/4 3F4000–3F5FFF 1FA000–1FAFFF SA66 111111011 8/4 3F6000–3F7FFF 1FB000–1FBFFF SA67 111111100 8/4 3F8000–3F9FFF 1FC000–1FCFFF SA68 111111101 8/4 3FA000–3FBFFF 1FD000–1FDFFF SA69 111111110 8/4 3FC000–3FDFFF 1FE000–1FEFFF SA70 111111111 8/4 3FE000–3FFFFF 1FF000–1FFFFF Note: The address bus is A20:A-1 in byte mode where BYTE# = VIL or A20:A0 in word mode where BYTE# = VIH This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 5 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Table 2B. Bottom Boot Sector Address Tables (EN29LV320BB) Sector A20 – A12 Sector Size (Kbytes / Kwords) Address Range (h) Byte mode (x8) Address Range (h) Word Mode (x16) SA0 000000000 8/4 000000–001FFF 000000–000FFF SA1 000000001 8/4 002000–003FFF 001000–001FFF SA2 000000010 8/4 004000–005FFF 002000–002FFF SA3 000000011 8/4 006000–007FFF 003000–003FFF SA4 000000100 8/4 008000–009FFF 004000–004FFF SA5 000000101 8/4 00A000–00BFFF 005000–005FFF SA6 000000110 8/4 00C000–00DFFF 006000–006FFF SA7 000000111 8/4 00E000–00FFFF 007000–007FFF SA8 000001xxx 64/32 010000–01FFFF 008000–00FFFF SA9 000010xxx 64/32 020000–02FFFF 010000–017FFF SA10 000011xxx 64/32 030000–03FFFF 018000–01FFFF SA11 000100xxx 64/32 040000–04FFFF 020000–027FFF SA12 000101xxx 64/32 050000–05FFFF 028000–02FFFF SA13 000110xxx 64/32 060000–06FFFF 030000–037FFF SA14 000111xxx 64/32 070000–07FFFF 038000–03FFFF SA15 001000xxx 64/32 080000–08FFFF 040000–047FFF SA16 001001xxx 64/32 090000–09FFFF 048000–04FFFF SA17 001010xxx 64/32 0A0000–0AFFFF 050000–057FFF SA18 001011xxx 64/32 0B0000–0BFFFF 058000–05FFFF SA19 001100xxx 64/32 0C0000–0CFFFF 060000–067FFF SA20 001101xxx 64/32 0D0000–0DFFFF 068000–06FFFF SA21 001110xxx 64/32 0E0000–0EFFFF 070000–077FFF SA22 001111xxx 64/32 0F0000–0FFFFF 078000–07FFFF SA23 010000xxx 64/32 100000–10FFFF 080000–087FFF SA24 010001xxx 64/32 110000–11FFFF 088000–08FFFF SA25 010010xxx 64/32 120000–12FFFF 090000–097FFF SA26 010011xxx 64/32 130000–13FFFF 098000–09FFFF SA27 010100xxx 64/32 140000–14FFFF 0A0000–0A7FFF SA28 010101xxx 64/32 150000–15FFFF 0A8000–0AFFFF SA29 010110xxx 64/32 160000–16FFFF 0B0000–0B7FFF SA30 010111xxx 64/32 170000–17FFFF 0B8000–0BFFFF SA31 011000xxx 64/32 180000–18FFFF 0C0000–0C7FFF SA32 011001xxx 64/32 190000–19FFFF 0C8000–0CFFFF SA33 011010xxx 64/32 1A0000–1AFFFF 0D0000–0D7FFF SA34 011011xxx 64/32 1B0000–1BFFFF 0D8000–0DFFFF SA35 011100xxx 64/32 1C0000–1CFFFF 0E0000–0E7FFF SA36 011101xxx 64/32 1D0000–1DFFFF 0E8000–0EFFFF SA37 011110xxx 64/32 1E0000–1EFFFF 0F0000–0F7FFF SA38 011111xxx 64/32 1F0000–1FFFFF 0F8000–0FFFFF SA39 100000xxx 64/32 200000–20FFFF 100000–107FFF This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 6 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B SA40 100001xxx 64/32 210000–21FFFF 108000–10FFFF SA41 100010xxx 64/32 220000–22FFFF 110000–117FFF SA42 100011xxx 64/32 230000–23FFFF 118000–11FFFF SA43 100100xxx 64/32 240000–24FFFF 120000–127FFF SA44 100101xxx 64/32 250000–25FFFF 128000–12FFFF SA45 100110xxx 64/32 260000–26FFFF 130000–137FFF SA46 100111xxx 64/32 270000–27FFFF 138000–13FFFF SA47 101000xxx 64/32 280000–28FFFF 140000–147FFF SA48 101001xxx 64/32 290000–29FFFF 148000–14FFFF SA49 101010xxx 64/32 2A0000–2AFFFF 150000–157FFF SA50 101011xxx 64/32 2B0000–2BFFFF 158000–15FFFF SA51 101100xxx 64/32 2C0000–2CFFFF 160000–167FFF SA52 101101xxx 64/32 2D0000–2DFFFF 168000–16FFFF SA53 101110xxx 64/32 2E0000–2EFFFF 170000–177FFF SA54 101111xxx 64/32 2F0000–2FFFFF 178000–17FFFF SA55 110000xxx 64/32 300000–30FFFF 180000–187FFF SA56 110001xxx 64/32 310000–31FFFF 188000–18FFFF SA57 110010xxx 64/32 320000–32FFFF 190000–197FFF SA58 110011xxx 64/32 330000–33FFFF 198000–19FFFF SA59 110100xxx 64/32 340000–34FFFF 1A0000–1A7FFF SA60 110101xxx 64/32 350000–35FFFF 1A8000–1AFFFF SA61 110110xxx 64/32 360000–36FFFF 1B0000–1B7FFF SA62 110111xxx 64/32 370000–37FFFF 1B8000–1BFFFF SA63 111000xxx 64/32 380000–38FFFF 1C0000–1C7FFF SA64 111001xxx 64/32 390000–39FFFF 1C8000–1CFFFF SA65 111010xxx 64/32 3A0000–3AFFFF 1D0000–1D7FFF SA66 111011xxx 64/32 3B0000–3BFFFF 1D8000–1DFFFF SA67 111100xxx 64/32 3C0000–3CFFFF 1E0000–1E7FFF SA68 111101xxx 64/32 3D0000–3DFFFF 1E8000–1EFFFF SA69 111110xxx 64/32 3E0000–3EFFFF 1F0000–1F7FFF SA70 111111xxx 64/32 3F0000–3FFFFF 1F8000–1FFFFF Note: The address bus is A20:A-1 in byte mode where BYTE# = VIL or A20:A0 in word mode where BYTE# = VIH This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 7 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Table 3. PRODUCT SELECTOR GUIDE Product Number EN29LV320B Speed -70 Max Access Time, ns (tacc) 70 Max CE# Access, ns (tce) 70 Max OE# Access, ns (toe) 30 BLOCK DIAGRAM RY/BY# Vcc Vss DQ0-DQ15 (A-1) Block Protect Switches Erase Voltage Generator Input/Output Buffers State Control WE# Command Register Program Voltage Generator Chip Enable Output Enable Logic CE# OE# Vcc Detector Timer Address Latch STB STB Data Latch Y-Decoder Y-Gating X-Decoder Cell Matrix A0-A20 This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 8 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B TABLE 4. OPERATING MODES 32M FLASH USER MODE TABLE Operation Read Write CE# L L OE# L H WE# H L RESET# H H WP#/ACC L/H (Note 1) A0A20 AIN AIN DQ0DQ7 DOUT DIN Accelerated Program L H L H VHH AIN DIN DQ8-DQ15 BYTE# BYTE# = VIL = VIH DOUT DQ8DQ14= DIN High-Z, DQ15 = DIN A-1 Vcc ±0.3V H L X X X Vcc±0.3V H X High-Z High-Z High-Z X H X X H X H H L H L/H L/H High-Z High-Z High-Z High-Z High-Z High-Z High-Z High-Z High-Z Sector (Group) Protect L H L VID L/H (Note 2) X X Sector Unprotect L H L VID (Note 1) (Note 2) X X Temporary Sector Unprotect X X X SA, A6=L, A1=H, A0=L SA, A6=H, A1=H, A0=L X X X VID (Note 1) (Note 2) (Note 2) High-Z CMOS Standby TTL Standby Output Disable Hardware Reset AIN L=logic low= VIL, H=Logic High= VIH, VID =VHH =11 ± 0.5V = 10.5-11.5V, X=Don’t Care (either L or H, but not floating ), SA=Sector Addresses, DIN=Data In, DOUT=Data Out, AIN=Address In Notes: 1. If WP#/ACC = VIL , the two outermost boot sectors remain protected. If WP# / ACC = VIH, the outermost boot sector protection depends on whether they were last protected or unprotected. If WP#/ACC = VHH, all sectors will be unprotected. 2. Please refer to “Sector/Sector Group Protection & Chip Unprotection”, Flowchart 7a and Flowchart 7b. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 9 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B TABLE 5. Autoselect Codes (Using High Voltage, VID) 32M FLASH MANUFACTURER/DEVICE ID TABLE Description CE# OE# WE# L L H Device ID Word L L H Byte L L H Word L L H Byte L L H L L H Device ID (bottom boot sector) Sector Protection Verification A11 to A10 A9 2 A8 A7 A6 A5 to A2 A1 A0 DQ8 to DQ15 X L X L L X DQ7 to DQ0 1 Manufacturer ID: Eon (top boot sector) A20 to A12 H X X VID X X VID X X L X L H X X VID X X L X L H SA X VID X X L X H L L 1Ch 7Fh 22h F6h X F6h 22h F9h X F9h 01h X X (Protected) 00h (Unprotected) L=logic low= VIL, H=Logic High= VIH, VID =11 ± 0.5V, X=Don’t Care (either L or H, but not floating!), SA=Sector Addresses Note: 1. A8=H is recommended for Manufacturing ID check. If a manufacturing ID is read with A8=L, the chip will output a configuration code 7Fh. 2. A9 = VID is for HV A9 Autoselect mode only. A9 must be ≤ Vcc (CMOS logic level) for Command Autoselect Mode. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 10 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B USER MODE DEFINITIONS Word / Byte Configuration The signal set on the BYTE# pin controls whether the device data I/O pins DQ15-DQ0 operate in the byte or word configuration. When the BYTE# Pin is set at logic ‘1’, then the device is in word configuration, DQ15-DQ0 are active and are controlled by CE# and OE#. On the other hand, if the BYTE# Pin is set at logic ‘0’, then the device is in byte configuration, and only data I/O pins DQ0-DQ7 are active and controlled by CE# and OE#. The data I/O pins DQ8-DQ14 are tri-stated, and the DQ15 pin is used as an input for the LSB (A-1) address function. Standby Mode The EN29LV320B has a CMOS-compatible standby mode, which reduces the current to < 1µA (typical). It is placed in CMOS-compatible standby when the CE# pin is at VCC ± 0.5. RESET# and BYTE# pin must also be at CMOS input levels. The device also has a TTL-compatible standby mode, which reduces the maximum VCC current to < 1mA. It is placed in TTL-compatible standby when the CE# pin is at VIH. When in standby modes, the outputs are in a high-impedance state independent of the OE# input. Automatic Sleep Mode The EN29LV320B has an automatic sleep mode, which minimizes power consumption. The devices will enter this mode automatically when the states of address bus remain stable for tacc + 30ns. ICC4 in the DC Characteristics table shows the current specification. With standard access times, the device will output new data when addresses change. Read Mode The device is automatically set to reading array data after device power-up or hardware reset. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm. After the device accepts a Sector Erase Suspend command, the device enters the Sector Erase Suspend mode. The system can read array data using the standard read timings, except that if it reads at an address within erase-suspended sectors, the device outputs status data. After completing a programming operation in the Sector Erase Suspend mode, the system may once again read array data with the same exception. See “Sector Erase Suspend/Resume Commands” for more additional information. The system must issue the reset command to re-enable the device for reading array data if DQ5 goes high or while in the autoselect mode. See the “Reset Command” for additional details. Output Disable Mode When the OE# pin is at a logic high level (VIH), the output from the EN29LV320B is disabled. The output pins are placed in a high impedance state. Autoselect Identification Mode The autoselect mode provides manufacturer and device identification, and sector protection verification, through identifier codes output on DQ15–DQ0. This mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programming algorithm. However, the autoselect codes can also be accessed in-system through the command register. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 11 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B When using programming equipment, the autoselect mode requires VID (10.5 V to 11.5 V) on address pin A9. Address pins A6, A1, and A0 must be as shown in Autoselect Codes table. In addition, when verifying sector protection, the sector address must appear on the appropriate highest order address bits. Refer to the corresponding Sector Address Tables. The “Command Definitions” table shows the remaining address bits that are don’t-care. When all necessary bits have been set as required, the programming equipment may then read the corresponding identifier code on DQ15–DQ0. To access the autoselect codes in-system; the host system can issue the autoselect command via the command register, as shown in the Command Definitions table. This method does not require VID. See “Command Definitions” for details on using the autoselect mode. Writing Command Sequences To write a command or command sequence to program data to the device or erase data, the system has to drive WE# and CE# to VIL, and OE# to VIH. For program operations, the BYTE# pin determines whether the device accepts program data in bytes or words. An erase operation can erase one sector or the whole chip. The system can also read the autoselect codes by entering the autoselect mode, which need the autoselect command sequence to be written. Please refer to the “Command Definitions” for all the available commands. RESET#: Hardware Reset When RESET# is driven low for tRP, all output pins are tristates. All commands written in the internal state machine are reset to reading array data. Please refer to timing diagram for RESET# pin in “AC Characteristics”. Sector/Sector Group Protection & Chip Unprotection The hardware sector group protection feature disables both program and erase operations in any sector. The hardware chip unprotection feature re-enables both program and erase operations in previously protected sectors. A sector group implies three or four adjacent sectors that would be protected at the same time. Please see the following tables which show the organization of sector groups. There are two methods to enable this hardware protection circuitry. The first one requires only that the RESET# pin be at VID and then standard microprocessor timings can be used to enable or disable this feature. See Flowchart 7a and 7b for the algorithm and Figure. 12 for the timings. When doing Chip Unprotect, all the unprotected sector groups must be protected prior to any unprotect write cycle. The second method is for programming equipment. This method requires VID to be applied to both OE# and A9 pins and non-standard microprocessor timings are used. This method is described in a separate document named EN29LV320B Supplement, which can be obtained by contacting a representative of Eon Silicon Solution, Inc. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 12 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B TABLE 6. Top Boot Sector/Sector Group Organization Table (EN29LV320BT) for (Un)Protection Sector Group Sectors SG 0 SG 1 SG 2 SG 3 SG 4 SG 5 SG 6 SG 7 SG 8 SG 9 SG10 SG11 SG12 SG13 SG14 SA 0-SA 3 SA 4-SA 7 SA 8-SA11 SA12-SA15 SA16-SA19 SA20-SA23 SA24-SA27 SA28-SA31 SA32-SA35 SA36-SA39 SA40-SA43 SA44-SA47 SA48-SA51 SA52-SA55 SA56-SA59 SG15 SA60-SA62 SG16 SG17 SG18 SG19 SG20 SG21 SG22 SG23 SA63 SA64 SA65 SA66 SA67 SA68 SA69 SA70 A20-A12 0000XXXXX 0001XXXXX 0010XXXXX 0011XXXXX 0100XXXXX 0101XXXXX 0110XXXXX 0111XXXXX 1000XXXXX 1001XXXXX 1010XXXXX 1011XXXXX 1100XXXXX 1101XXXXX 1110XXXXX 111100XXX 111101XXX 111110XXX 111111000 111111001 111111010 111111011 111111100 111111101 111111110 111111111 Sector Group Size 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 3 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes TABLE 7. Bottom Boot Sector/Sector Group Organization Table (EN29LV320BB) for (Un)Protection Sector Group Sectors SG23 SG22 SG21 SG20 SG19 SG18 SG17 SG16 SG15 SG14 SG13 SG12 SG11 SG10 SG 9 SA70-SA67 SA66-SA63 SA62-SA59 SA58-SA55 SA54-SA51 SA50-SA47 SA46-SA43 SA42-SA39 SA38-SA35 SA34-SA31 SA30-SA27 SA26-SA23 SA22-SA19 SA18-SA15 SA14-SA11 SG 8 SA10-SA 8 SG SG SG SG SG SG SG SG SA SA SA SA SA SA SA SA 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 A20-A12 1111XXXXX 1110XXXXX 1101XXXXX 1100XXXXX 1011XXXXX 1010XXXXX 1001XXXXX 1000XXXXX 0111XXXXX 0110XXXXX 0101XXXXX 0100XXXXX 0011XXXXX 0010XXXXX 0001XXXXX 000011XXX 000010XXX 000001XXX 000000111 000000110 000000101 000000100 000000011 000000010 000000001 000000000 Sector Group Size 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 3 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 13 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Write Protect / Accelerated Program (WP# / ACC) The WP#/ACC pin provides two functions. The Write Protect (WP#) function provides a hardware method of protecting the outermost two 8K-byte Boot Sector. The ACC function allows faster manufacturing throughput at the factory, using an external high voltage. When WP#/ACC is Low, the device protects the outermost two 8K-byte Boot Sector; no matter the sectors are protected or unprotected using the method described in “Sector/Sector Group Protection & Chip Unprotection”, Program and Erase operations in these sectors are ignored. When WP#/ACC is High, the device reverts to the previous protection status of the outermost two 8Kbyte boot sector. Program and Erase operations can now modify the data in the two outermost 8K-byte Boot Sector unless the sector is protected using Sector Protection. When WP#/ACC is raised to VHH the memory automatically enters the Accelerated Program mode, this mode permit the system to skip the normal command unlock sequences and program byte/word locations directly to reduces the time required for program operation. When WP#/ACC returns to VIH or VIL, normal operation resumes. The transitions from VIH or VIL to VHH and from VHH to VIH or VIL must be slower than tVHH, see Figure 11. Note that the WP#/ACC pin must not be left floating or unconnected. In addition, WP#/ACC pin must not be at VHH for operations other than accelerated programming. It could cause the device to be damaged. Never raise this pin to VHH from any mode except Read mode. Otherwise the memory may be left in an indeterminate state. A 0.1µF capacitor should be connected between the WP#/ACC pin and the VSS Ground pin to decouple the current surges from the power supply. The PCB track widths must be sufficient to carry the currents required during Accelerated Program mode. Temporary Sector Unprotect This feature allows temporary unprotection of previously protected sector groups to change data while in-system. The Temporary Sector Unprotect mode is activated by setting the RESET# pin to VBIDB. During this mode, formerly protected sectors can be programmed or erased by simply selecting the sector addresses. Once VBIDB is removed from the RESET# pin, all the previously protected sectors are protected again. See accompanying flowchart and figure 10 for more timing details. Notes: 1. All protected sectors are unprotected. (If WP#/ACC=VIL, outermost boot sectors will remain protected.) 2. Previously protected sectors are protected again. Start Reset#=VID (note 1) Perform Erase or Program Operations RESET#=VIH Temporary Sector Unprotect Completed (note 2) This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 14 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B COMMON FLASH INTERFACE (CFI) The common flash interface (CFI) specification outlines device and host systems software interrogation handshake, which allows specific vendor-specified software algorithms to be used for entire families of devices. Software support can then be device-independent, JEDEC IDindependent, and forward- and backward-compatible for the specified flash device families. Flash vendors can standardize their existing interfaces for long-term compatibility. This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to address 55h in word mode (or address AAh in byte mode), any time the device is ready to read array data. The system can read CFI information at the addresses given in Tables 5-8.In word mode, the upper address bits (A7–MSB) must be all zeros. To terminate reading CFI data, the system must write the reset command. The system can also write the CFI query command when the device is in the autoselect mode. The device enters the CFI query mode and the system can read CFI data at the addresses given in Tables 5–8. The system must write the reset command to return the device to the autoselect mode. Table 8. CFI Query Identification String Addresses (Word Mode) 10h 11h 12h 13h 14h 15h 16h 17h 18h 19h 1Ah Adresses (Byte Mode) 20h 22h 24h 26h 28h 2Ah 2Ch 2Eh 30h 32h 34h Data 0051h 0052h 0059h 0002h 0000h 0040h 0000h 0000h 0000h 0000h 0000h Description Query Unique ASCII string “QRY” Primary OEM Command Set Address for Primary Extended Table Alternate OEM Command set (00h = none exists) Address for Alternate OEM Extended Table (00h = none exists) Table 9. System Interface String Addresses (Word Mode) Addresses (Byte Mode) 1Bh 36h 1Ch 38h 1Dh 1Eh 1Fh 3Ah 3Ch 3Eh 20h 40h 21h 22h 23h 24h 25h 42h 44h 46h 48h 4Ah 26h 4Ch Data 0027h 0036h 0000h 0000h 0004h 0000h 000Ah 0000h 0005h 0000h 0004h 0000h Description Vcc Min (write/erase) DQ7-DQ4: volt, DQ3 –DQ0: 100 millivolt Vcc Max (write/erase) DQ7-DQ4: volt, DQ3 –DQ0: 100 millivolt Vpp Min. voltage (00h = no Vpp pin present) Vpp Max. voltage (00h = no Vpp pin present) N Typical timeout per single byte/word write 2 µS N Typical timeout for Min, size buffer write 2 µS (00h = not supported) N Typical timeout per individual block erase 2 ms N Typical timeout for full chip erase 2 ms (00h = not supported) Max. timeout for byte/word write 2N times typical N Max. timeout for buffer write 2 times typical N Max. timeout per individual block erase 2 times typical N Max timeout for full chip erase 2 times typical (00h = not supported) This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 15 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Table 10. Device Geometry Definition Addresses (Word mode) 27h 28h 29h 2Ah 2Bh 2Ch 2Dh 2Eh 2Fh 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h 3Ah 3Bh 3Ch Addresses (Byte Mode) 4Eh 50h 52h 54h 56h 58h 5Ah 5Ch 5Eh 60h 62h 64h 66h 68h 6Ah 6Ch 6Eh 70h 72h 74h 76h 78h Addresses (Word Mode) 40h 41h 42h 43h 44h Addresses (Byte Mode) 80h 82h 84h 86h 88h Data 0050h 0052h 0049h 0031h 0031h 45h 8Ah 0000h 46h 8Ch 0002h 47h 8Eh 0004h 48h 90h 0001h 49h 92h 0004h 4Ah 94h 0000h 4Bh 96h 0000h 4Ch 98h 0000h 4Dh 9Ah 00A5h 4Eh 9Ch 00B5h 4Fh 9Eh 0002h/ 0003h Data 0016h 0002h 0000h 0000h 0000h 0002h 0007h 0000h 0020h 0000h 003Eh 0000h 0000h 0001h 0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h Description N Device Size = 2 bytes Flash Device Interface description (refer to CFI publication 100) N Max. number of byte in multi-byte write = 2 (00h = not supported) Number of Erase Block Regions within device Erase Block Region 1 Information (refer to the CFI specification of CFI publication 100) Erase Block Region 2 Information Erase Block Region 3 Information Erase Block Region 4 Information Table 11. Primary Vendor-specific Extended Query Description Query-unique ASCII string “PRI” Major version number, ASCII Minor version number, ASCII Address Sensitive Unlock 0 = Required, 1 = Not Required Erase Suspend 0 = Not Supported, 1 = To Read Only, 2 = To Read & Write Sector Protect 0 = Not Supported, X = Number of sectors in per group Sector Temporary Unprotect 00 = Not Supported, 01 = Supported Sector Protect/Unprotect scheme 01 = 29F040 mode, 02 = 29F016 mode, 03 = 29F400 mode, 04 = 29LV800A mode Simultaneous Operation 00 = Not Supported, 01 = Supported Burst Mode Type 00 = Not Supported, 01 = Supported Page Mode Type 00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page Minimum ACC (Acceleration) Supply Voltage 00 = Not Supported, DQ7-DQ4 : Volts, DQ3-DQ0 : 100mV Maximum ACC (Acceleration) Supply Voltage 00 = Not Supported, DQ7-DQ4 : Volts, DQ3-DQ0 : 100mV Top/Bottom Boot Sector Identifier 02h = Bottom Boot, 03h = Top Boot This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 16 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Hardware Data protection The command sequence requirement of unlock cycles for programming or erasing provides data protection against inadvertent writes as seen in the Command Definitions table. Additionally, the following hardware data protection measures prevent accidental erasure or programming, which might otherwise be caused by false system level signals during Vcc power up and power down transitions, or from system noise. Low VCC Write Inhibit When Vcc is less than VLKO, the device does not accept any write cycles. This protects data during Vcc power up and power down. The command register and all internal program/erase circuits are disabled, and the device resets. Subsequent writes are ignored until Vcc is greater than VLKO. The system must provide the proper signals to the control pins to prevent unintentional writes when Vcc is greater than VLKO. Write Pulse “Glitch” protection Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle. Logical Inhibit Write cycles are inhibited by holding any one of OE# = VIL, CE# = VIH, or WE# = VIH. To initiate a write cycle, CE# and WE# must be a logical zero while OE# is a logical one. If CE#, WE#, and OE# are all logical zero (not recommended usage), it will be considered a read. Power-up Write Inhibit During power-up, the device automatically resets to READ mode and locks out write cycles. Even with CE# = VIL, WE#= VIL and OE# = VIH, the device will not accept commands on the rising edge of WE#. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 17 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B COMMAND DEFINITIONS The operations of the device are selected by one or more commands written into the command register. Commands are made up of data sequences written at specific addresses via the command register. The sequences for the specified operation are defined in the Command Definitions table (Table 9). Incorrect addresses, incorrect data values or improper sequences will reset the device to Read Mode. Table 12. EN29LV320B Command Definitions Cycles Bus Cycles Read 1 RA RD Reset 1 xxx F0 Command Sequence Autoselect Manufacturer ID Word Byte Device ID Top Boot Word Device ID Bottom Boot Word Sector Protect Verify Program Chip Erase Sector Erase Byte Byte Word Byte Word Byte Word Byte Word Byte 4 4 4 4 4 6 6 st 1 Cycle 555 AAA 555 AAA 555 AAA 555 AAA 555 AAA 555 AAA 555 AAA AA AA AA AA AA AA AA 1 xxx B0 Sector Erase Resume 1 xxx 30 CFI Query Byte 1 55 AA 2AA 555 2AA 555 2AA 555 Cycle 55 55 55 2AA Sector Erase Suspend Word 2 nd 555 2AA 555 2AA 555 2AA 555 55 55 55 55 rd 3 Cycle 555 AAA 555 AAA 555 AAA 555 AAA 555 AAA 555 AAA 555 AAA th 4 Cycle 000 100 000 200 x01 7F 1C 7F 1C 22F6 x02 F6 x01 22F9 x02 F9 90 (SA) X02 (SA) X04 00 01 00 01 A0 PA 90 90 90 80 80 555 AAA 555 AAA th 5 Cycle th 6 Cycle PD AA AA 2AA 555 2AA 555 55 55 555 AAA SA 98 Address and Data values indicated are in hex. Unless specified, all bus cycles are write cycles RA = Read Address: address of the memory location to be read. This is a read cycle. RD = Read Data: data read from location RA during Read operation. This is a read cycle. PA = Program Address: address of the memory location to be programmed. X = Don’t-Care PD = Program Data: data to be programmed at location PA SA = Sector Address: address of the Sector to be erased or verified. Address bits A20-A12 uniquely select any Sector. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 18 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com 10 30 EN29LV320B Reading Array Data The device is automatically set to reading array data after power up. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm. Following a Sector Erase Suspend command, Sector Erase Suspend mode is entered. The system can read array data using the standard read timings from sectors other than the one which is being erasesuspended. If the system reads at an address within erase-suspended sectors, the device outputs status data. After completing a programming operation in the Sector Erase Suspend mode, the system may once again read array data with the same exception. The Reset command must be issued to re-enable the device for reading array data if DQ5 goes high during an active program or erase operation or while in the autoselect mode. See next section for details on Reset. Reset Command Writing the reset command to the device resets the device to reading array data. Address bits are don’tcare for this command. The reset command may be written between the cycle sequences in an erase command sequence before erasing begins. This resets the device to reading array data. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to reading array data (also applies to programming in Sector Erase Suspend mode). Once programming begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the cycle sequences in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to reading array data. If DQ5 goes high during a program or erase operation, writing the reset command returns the device to reading array data (also applies in Sector Erase Suspend mode). Autoselect Command Sequence The autoselect command sequence allows the host system to access the manufacturer and devices ID codes, and determine whether or not a sector (group) is protected. The Command Definitions table shows the address and data requirements. This is an alternative to the method that requires VID on address bit A9 and is intended for commercial programmers. Two unlock cycles followed by the autoselect command initiate the autoselect command sequence. Autoselect mode is then entered and the system may read at addresses shown in Table 9 any number of times, without needing another command sequence. The system must write the reset command to exit the autoselect mode and return to reading array data. Word / Byte Programming Command The device can be programmed by byte or by word, depending on the state of the BYTE# Pin. Programming the EN29LV320B is performed by using a four-bus-cycle operation (two unlock write cycles followed by the Program Setup command and Program Data Write cycle). When the program command is executed, no additional CPU controls or timings are necessary. An internal timer terminates the program operation automatically. Address is latched on the falling edge of CE# or WE#, whichever is last; data is latched on the rising edge of CE# or WE#, whichever is first. Any commands written to the device during the program operation are ignored. Programming status can be checked by sampling data on DQ7 (DATA# polling) or on DQ6 (toggle bit). When the program operation is successfully completed, the device returns to read mode and the user can read the data This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 19 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B programmed to the device at that address. Note that data can not be programmed from a “0” to a “1”. Attempting to do so may halt the operation and set DQ5 to “1”, or cause the Data# Polling algorithm to indicate the operation was successful. However, a succeeding read will show that the data is still “0”. Only erase operations can convert a “0” to a “1”. When programming time limit is exceeded, DQ5 will produce a logical “1” and a Reset command can return the device to Read mode. Programming is allowed in any sequence across sector boundaries. Chip Erase Command Chip erase is a six-bus-cycle operation. The chip erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the chip erase command, which in turn invokes the Embedded Erase algorithm. The device does not require the system to preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. The Command Definitions table shows the address and data requirements for the chip erase command sequence. Any commands written to the chip during the Embedded Chip Erase algorithm are ignored. The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. See “Write Operation Status” for information on these status bits. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. Sector Erase Command Sequence Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by writing two un-lock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the address of the sector to be erased, and the sector erase command. The Command Definitions table shows the address and data requirements for the sector erase command sequence. Once the sector erase operation has begun, only the Sector Erase Suspend command is valid. All other commands are ignored. If there are several sectors to be erased, Sector Erase Command sequences must be issued for each sector. That is, only a sector address can be specified for each Sector Erase command. Users must issue another Sector Erase command for the next sector to be erased after the previous one is completed. When the Embedded Erase algorithm is completed, the device returns to reading array data and addresses are no longer latched. The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. Refer to “Write Operation Status” for information on these status bits. Flowchart 4 illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations tables in the “AC Characteristics” section for parameters, and to the Sector Erase Operations Timing diagram for timing waveforms. Sector Erase Suspend / Resume Command The Sector Erase Suspend command allows the system to interrupt a sector erase operation and then read data from, or program data to, any sector not selected for erasure. This command is valid only during the sector erase operation. The Sector Erase Suspend command is ignored if written during the chip erase operation or Embedded Program algorithm. Addresses are don’t-cares when writing the Sector Erase Suspend command. When the Sector Erase Suspend command is written during a sector erase operation, the device requires a maximum of 20 µs to suspend the erase operation. After the erase operation has been suspended, the system can read array data from or program data to any sector not selected for erasure. Normal read and write timings and command definitions apply. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 20 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Please note that Autoselect command sequence can not be accepted during Sector Erase Suspend. Reading at any address within erase-suspended sectors produces status data on DQ7–DQ0. The system can use DQ7, or DQ6 and DQ2 together, to determine if a sector is actively erasing or is erasesuspended. See “Write Operation Status” for information on these status bits. After an erase-suspended program operation is complete, the system can once again read array data within non-suspended sectors. The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard program operation. See “Write Operation Status” for more information. The Autoselect command is not supported during Sector Erase Suspend Mode. The system must write the Sector Erase Resume command (address bits are don’t-care) to exit the sector erase suspend mode and continue the sector erase operation. Further writes of the Resume command are ignored. Another Sector Erase Suspend command can be written after the device has resumed erasing. WRITE OPERATION STATUS DQ7: DATA# Polling The EN29LV320B provides DATA# polling on DQ7 to indicate the status of the embedded operations. The DATA# Polling feature is active during the Word/Byte Programming, Sector Erase, Chip Erase, and Sector Erase Suspend. (See Table 10) When the embedded programming is in progress, an attempt to read the device will produce the complement of the data written to DQ7. Upon the completion of the programming operation, an attempt to read the device will produce the true data written to DQ7. DATA# polling is valid after the rising edge of the fourth WE# or CE# pulse in the four-cycle sequence for program. When the embedded Erase is in progress, an attempt to read the device will produce a “0” at the DQ7 output. Upon the completion of the embedded Erase, the device will produce the “1” at the DQ7 output during the read cycles. For Chip Erase or Sector Erase, DATA# polling is valid after the rising edge of the last WE# or CE# pulse in the six-cycle sequence. DATA# Polling must be performed at any address within a sector that is being programmed or erased and not a protected sector. Otherwise, DATA# polling may give an inaccurate result if the address used is in a protected sector. Just prior to the completion of the embedded operations, DQ7 may change asynchronously when the output enable (OE#) is low. This means that the device is driving status information on DQ7 at one instant of time and valid data at the next instant of time. Depending on the time the system samples the DQ7 output, it may read the status of valid data. Even if the device has completed the embedded operation and DQ7 has a valid data, the data output on DQ0-DQ6 may be still invalid. The valid data on DQ0-DQ7 should be read on the subsequent read attempts. The flowchart for DATA# Polling (DQ7) is shown on Flowchart 5. The DATA# Polling (DQ7) timing diagram is shown in Figure 6. RY/BY#: Ready/Busy Status output The RY/BY# is a dedicated, open-drain output pin that indicates whether an Embedded Algorithm is in progress or completed. The RY/BY# status is valid after the rising edge of the final WE# pulse in the command sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together in parallel with a pull-up resistor to Vcc. In the output-low period, signifying Busy, the device is actively erasing or programming. This includes programming in the Erase Suspend mode. If the output is high, signifying the Ready, the device is ready to read array data (including during the Erase Suspend mode), or is in the standby mode. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 21 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B DQ6: Toggle Bit I The EN29LV320B provides a “Toggle Bit” on DQ6 to indicate the status of the embedded programming and erase operations. (See Table 10) During an embedded Program or Erase operation, successive attempts to read data from the device at any address (by active OE# or CE#) will result in DQ6 toggling between “zero” and “one”. Once the embedded Program or Erase operation is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During Programming, the Toggle Bit is valid after the rising edge of the fourth WE# pulse in the four-cycle sequence. During Erase operation, the Toggle Bit is valid after the rising edge of the sixth WE# pulse for sector erase or chip erase. In embedded programming, if the sector being written to is protected, DQ6 will toggles for about 2 µs, then stop toggling without the data in the sector having changed. In Sector Erase or Chip Erase, if all selected sectors are protected, DQ6 will toggle for about 100 µs. The chip will then return to the read mode without changing data in all protected sectors. The flowchart for the Toggle Bit (DQ6) is shown in Flowchart 6. The Toggle Bit timing diagram is shown in Figure 7. DQ5: Exceeded Timing Limits DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count limit. Under these conditions DQ5 produces a “1.” This is a failure condition that indicates the program or erase cycle was not successfully completed. Since it is possible that DQ5 can become a 1 when the device has successfully completed its operation and has returned to read mode, the user must check again to see if the DQ6 is toggling after detecting a “1” on DQ5. The DQ5 failure condition may appear if the system tries to program a “1” to a location that is previously programmed to “0.” Only an erase operation can change a “0” back to a “1.” Under this condition, the device halts the operation, and when the operation has exceeded the timing limits, DQ5 produces a “1.” Under both these conditions, the system must issue the reset command to return the device to reading array data. DQ3: Sector Erase Timer After writing a sector erase command sequence, the output on DQ3 can be checked to determine whether or not an erase operation has begun. (The sector erase timer does not apply to the chip erase command.) When sector erase starts, DQ3 switches from “0” to “1”. This device does not support multiple sector erase (continuous sector erase) command sequences so it is not very meaningful since it immediately shows as a “1” after the first 30h command. Future devices may support this feature. DQ2: Erase Toggle Bit II The “Toggle Bit” on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector is erase-suspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command sequence. DQ2 toggles when the system reads at addresses within those sectors that have been selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and mode information. Refer to the following table to compare outputs for DQ2 and DQ6. Flowchart 6 shows the toggle bit algorithm, and the section “DQ2: Toggle Bit” explains the algorithm. See also the “DQ6: Toggle Bit I” subsection. Refer to the Toggle Bit Timings figure for the toggle bit This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 22 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B timing diagram. The DQ2 vs. DQ6 figure shows the differences between DQ2 and DQ6 in graphical form. Reading Toggle Bits DQ6/DQ2 Refer to Flowchart 6 for the following discussion. Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is toggling. Typically, a system would note and store the value of the toggle bit after the first read. After the second read, the system would compare the new value of the toggle bit with the first. If the toggle bit is not toggling, the device has completed the program or erase operation. The system can read array data on DQ7–DQ0 on the following read cycle. However, after the initial two read cycles, the system determines that the toggle bit is still toggling. And the system also should note whether the value of DQ5 is high (see the section on DQ5). If it is, the system should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling just as DQ5 went high. If the toggle bit is no longer toggling, the device has successfully completed the program or erase operation. If it is still toggling, the device did not complete the operation successfully, and the system must write the reset command to return to reading array data. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 23 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Table 13. Write Operation Status Operation Standard Mode Erase Suspend Mode DQ7 DQ6 DQ5 DQ3 DQ2 RY/BY# Embedded Program Algorithm DQ7# Toggle 0 N/A No toggle 0 Embedded Erase Algorithm 0 Toggle 0 1 Toggle 0 1 No Toggle 0 N/A Toggle 1 Data Data Data Data Data 1 DQ7# Toggle 0 N/A N/A 0 Reading within Erase Suspended Sector Reading within Non-Erase Suspended Sector Erase-Suspend Program Table 14. Status Register Bits DQ Name Logic Level ‘1’ 7 DATA# POLLING ‘0’ DQ7 DQ7# ‘-1-0-1-0-1-0-1-’ 6 TOGGLE BIT DQ6 ‘-1-1-1-1-1-1-1-‘ 5 TIME OUT BIT 3 ERASE TIME OUT BIT 2 TOGGLE BIT Definition Erase Complete or erased sector in Sector Erase Suspend Erase On-Going Program Complete or data of non-erased sector during Sector Erase Suspend Program On-Going Erase or Program On-going Read during Sector Erase Suspend Erase Complete ‘1’ Program or Erase Error ‘0’ Program or Erase On-going ‘1’ Erase operation start ‘0’ Erase timeout period on-going ‘-1-0-1-0-1-0-1-’ Chip Erase, Sector Erase or Read within EraseSuspended sector. (When DQ5=1, Erase Error due to currently addressed Sector or Program on Erase-Suspended sector DQ2 Read on addresses of non Erase-Suspend sectors Notes: DQ7: DATA# Polling: indicates the P/E status check during Program or Erase, and on completion before checking bits DQ5 for Program or Erase Success. DQ6: Toggle Bit: remains at constant level when P/E operations are complete or erase suspend is acknowledged. Successive reads output complementary data on DQ6 while programming or Erase operation are on-going. DQ5: Time Out Bit: set to “1” if failure in programming or erase DQ3: Sector Erase Command Timeout Bit: Operation has started. Only possible command is Erase suspend (ES). DQ2: Toggle Bit: indicates the Erase status and allows identification of the erased Sector. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 24 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B EMBEDDED ALGORITHMS Flowchart 1. Embedded Program START Write Program Command Sequence (shown below) Data# Poll Device Verify Data? Increment Address Last No Address? Yes Programming Done Flowchart 2. Embedded Program Command Sequence (See the Command Definitions section for more information.) 555H / AAH 2AAH / 55H 555H / A0H PROGRAM ADDRESS / PROGRAM DATA This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 25 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Flowchart 3. Embedded Erase START Write Erase Command Sequence Data Poll from System or Toggle Bit successfully completed No Data =FFh? Yes Erase Done Flowchart 4. Embedded Erase Command Sequence (See the Command Definitions section for more information.) Chip Erase Sector Erase 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/80H 555H/80H 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/10H Sector Address/30H This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 26 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Flowchart 5. DATA# Polling Algorithm Start Read Data DQ7 = Data? Yes No No DQ5 = 1? Yes Read Data (1) Notes: (1) This second read is necessary in case the first read was done at the exact instant when the status data was in transition. DQ7 = Data? Yes No Fail Pass Start Flowchart 6. Toggle Bit Algorithm Read Data twice DQ6 = Toggle? No Yes No DQ5 = 1? Yes Read Data twice (2) Notes: (2) This second set of reads is necessary in case the first set of reads was done at the exact instant when the status data was in transition. DQ6 = Toggle? No Yes Fail This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 27 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 Pass www.eonssi.com EN29LV320B Flowchart 7a. In-System Sector (Group) Protect Flowchart START PLSCNT = 1 RESET# = VID Wait 1 µs Temporary Chip Unprotect Mode No First Write Cycle = 60h? Yes Set up sector (group) address To Protect: Write 60h to sector addr with A6 = 0, A1 = 1, A0 = 0 Wait 150 µs To Verify: Write 40h to sector(group) address with A6 = 0, A1 = 1, A0 = 0 Increment PLSCNT Reset PLSCNT = 1 Wait 0.4 µs Read from sector address with A6 = 0, A1 = 1, A0 = 0 No PLSCNT = 25? Yes Device failed No Data = 01h? Yes Protect another sector? Yes No Remove VID from RESET# Write reset command Sector Protect Algorithm Sector Protect complete This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 28 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Flowchart 7b. In-System Chip Unprotect Flowchart START PLSCNT = 1 Protect all sectors (groups): The indicated portion of the sector protect algorithm must be performed for all unprotected sectors prior to issuing the first sector unprotect address (see Diagram 7a.) RESET# = VID Wait 1 µS First Write Cycle = 60h? No Temporary Chip Unprotect Mode Yes No All sectors protected? Yes Set up first sector address Chip Unprotect: Write 60H to sector address with A6 = 1, A1 = 1, A0 = 0 Wait 15 ms Increment PLSCNT Verify Chip Unprotect: Write 40h to sector address with A6 = 1, A1 = 1, A0 =0 Wait 0.4 µS No PLSCCNT = 1000? Yes Device failed Read from sector address with A6 = 1, A1 = 1, A0 = 0 No Set up next sector (group) address Data = 00h? Yes Last sector verified? No Yes Chip Unprotect Algorithm Remove VID from RESET# Write reset command Chip Unprotect complete This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 29 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B DC Characteristics Table 15. DC Characteristics (Ta = 0°C to 70°C or - 40°C to 85°C; VCC = 2.7-3.6V) Symbol Parameter ILI Input Leakage Current ILO Output Leakage Current ICC1 Active Read Current ( Byte mode ) Active Read Current ( Word mode ) ICC2 Supply Current (Program or Erase) ICC3 Supply Current (Standby - CMOS) ICC4 Reset Current ICC5 Automatic Sleep Mode VIL Input Low Voltage VIH Input High Voltage Test Conditions Max Unit ±5 µA ±5 µA CE# = VIL ; OE# = VIH ; f = 5MHz 9 16 mA 9 16 mA CE# = VIL, OE# = VIH , 20 30 mA 1 5.0 µA RESET# = Vss ± 0.3V 1 5.0 µA VIH = Vcc ± 0.3V 1 5.0 µA -0.5 0.7 x Vcc 0.8 Vcc + 0.3 V 10.5 11.5 V 10.5 11.5 V 0.45 V 0V≤ VOUT ≤ Vcc WE# = VIL CE# = BYTE# = RESET# = Vcc ± 0.3V (Note 1) VIL = Vss ± 0.3V VOL IOL = 4.0 mA VOH Output High Voltage CMOS IOH = -100 µA VLKO Supply voltage (Erase and Program lock-out) VID Typ 0V≤ VIN ≤ Vcc #WP/ACC Voltage (Write Protect / Program Acceleration) Voltage for Autoselect or Temporary Sector Unprotect Output Low Voltage VHH Min Vcc 0.4V 2.3 V V 2.5 V Notes: 1. BYTE# pin can also be GND ± 0.3V. BYTE# and RESET# pin input buffers are always enabled so that they draw power if not at full CMOS supply voltages. 2. Maximum ICC specifications are tested with Vcc = Vcc max. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 30 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Test Conditions Test Specifications Test Conditions -70 Unit Output Load Capacitance, CL 30 pF Input Rise and Fall times 5 ns Input Pulse Levels Input timing measurement reference levels Output timing measurement reference levels 0.0-3.0 V 1.5 V 1.5 V This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 31 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B AC CHARACTERISTICS Table 16. Hardware Reset (RESET#) Parameter Std tRP1 tRP2 tRH tRB1 tRB2 tREADY1 tREADY2 Description RESET# Pulse Width (During Embedded Algorithms) RESET# Pulse Width (NOT During Embedded Algorithms) Reset# High Time Before Read RY/BY# Recovery Time ( to CE#, OE# go low) RY/BY# Recovery Time ( to WE# go low) Reset# Pin Low (During Embedded Algorithms) to Read or Write Reset# Pin Low (NOT During Embedded Algorithms) to Read or Write Test Setup Min Min Min Min Min Speed -70 10 500 50 0 50 Max 20 us Max 500 ns Unit us ns ns ns ns Figure 1. AC Waveforms for RESET# Reset# Timings This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 32 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B AC CHARACTERISTICS Table 17. Word / Byte Configuration (BYTE#) Std Parameter tBCS tCBH tRBH Description Byte# to CE# switching setup time CE# to Byte# switching hold time RY/BY# to Byte# switching hold time Test Setup Min Min Min Speed -70 Unit 0 0 0 ns ns ns Figure 2. AC Waveforms for BYTE# CE# OE# Byte# tCBH tBCS Byte# timings for Read Operations CE# WE# Byte# tBCS tRBH RY/BY# Byte #timings for Write Operations Note: Switching BYTE# pin not allowed during embedded operations This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 33 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B AC CHARACTERISTICS Table 18. Read-only Operations Characteristics Parameter Symbols Speed Test Setup Description JEDEC Standard tAVAV tRC Read Cycle Time tAVQV tACC Address to Output Delay tELQV tCE Chip Enable To Output Delay tGLQV tOE tEHQZ Unit -70 Min 70 ns CE# = VIL OE#= VIL Max 70 ns OE#= VIL Max 70 ns Output Enable to Output Delay Max 30 ns tDF Chip Enable to Output High Z Max 20 ns tGHQZ tDF Output Enable to Output High Z Max 20 ns tAXQX tOH Output Hold Time from Addresses, CE# or OE#, whichever occurs first Min 0 ns tOEH Output Enable Hold Time MIn 0 ns Min 10 ns Read Toggle and DATA# Polling Notes: 1. High Z is Not 100% tested. 2. For - 70 Vcc = 2.7V – 3.6V Output Load: 30pF Input Rise and Fall Times: 5ns Input Pulse Levels: 0.0 V to 3.0 V Timing Measurement Reference Level, Input and Output: 1.5 V Figure 3. AC Waveforms for READ Operations tRC Addresses Addresses Stable tACC CE# tDF tOE OE# tOEH WE# tCE HIGH Z Outputs tOH Output Valid HIGH Z RESET# RY/BY# 0V This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 34 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B AC CHARACTERISTICS Table 19. Write (Erase/Program) Operations Parameter Symbols Speed Description Unit JEDEC Standard tAVAV tWC Write Cycle Time Min 70 ns tAVWL tAS Address Setup Time Min 0 ns tWLAX tAH Address Hold Time Min 45 ns tDVWH tDS Data Setup Time Min 30 ns tWHDX tDH Data Hold Time Min 0 ns Output Enable Setup Time Min 0 ns Output Read Enable Toggle and Hold Time DATA# Polling Read Recovery Time before Write (OE# High to WE# Low) MIn 0 ns Min 10 ns Min 0 ns tOES tOEH -70 tGHWL tGHWL tELWL tCS CE# Setup Time Min 0 ns tWHEH tCH CE# Hold Time Min 0 ns tWLWH tWP Write Pulse Width Min 45 ns tWHDL tWPH Write Pulse Width High Min 20 ns tWHW1 tWHWH1 Programming Operation Byte Typ 8 Word Typ 8 tWHW1 tWHWH1 Accelerated Programming Operation (Word AND Byte Mode) Typ 7 µs tWHW2 tWHWH2 Sector Erase Operation Typ 0.1 s tWHW3 tWHWH3 Chip Erase Operation Typ 8 s Vcc Setup Time Min 50 µs WE# High to RY/BY# Low Min 70 ns Min 0 ns tVCS t BUSY B tRB µs Recovery Time from RY/BY# Notes: tWC is Not 100% tested. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 35 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B AC CHARACTERISTICS Table 20. Write (Erase/Program) Operations Alternate CE# Controlled Writes Parameter Symbols Speed Options Description Unit JEDEC Standard tAVAV tWC Write Cycle Time Min 70 ns tAVEL tAS Address Setup Time Min 0 ns tELAX tAH Address Hold Time Min 45 ns tDVEH tDS Data Setup Time Min 30 ns tEHDX tDH Data Hold Time Min 0 ns Output Enable Setup Time Min 0 ns Min 0 ns Min 10 ns Min 0 ns tOES tOEH -70 Output Enable Read Toggle and Data Polling Read Recovery Time before Write (OE# High to CE# Low) Hold Time tGHEL tGHEL tWLEL tWS WE# Setup Time Min 0 ns tEHWH tWH WE# Hold Time Min 0 ns tELEH tCP CE# Pulse Width Min 35 ns tEHEL tCPH CE# Pulse Width High Min 20 ns tWHW1 tWHWH1 Programming Operation Byte Typ 8 Word Typ 8 tWHW1 tWHWH1 Accelerated Programming Operation (Word AND Byte Mode) Typ 7 µs tWHW2 tWHWH2 Sector Erase Operation Typ 0.1 s Vcc Setup Time Min 50 µs Min 0 ns tVCS tRB Recovery Time from RY/BY# µs Notes: tWC is Not 100% tested. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 36 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B AC CHARACTERISTICS Figure 4. AC Waveforms for WE# Control Chip/Sector Erase Operations Timings Erase Command Sequence (last 2 cycles) tAS tWC Addresses 0x2AA Read Status Data (last two cycles) tAH SA VA VA 0x555 for chip erase CE# tGHW tCH OE# tWP WE# tCS tWP 0x55 Data tDS tWHWH2 or tWHWH3 0x30 tDH Status tBUS DOUT tRB RY/BY# VCC tVCS Notes: 1. SA=Sector Address (for sector erase), VA=Valid Address for reading status, Dout =true data at read address. 2. Vcc shown only to illustrate tvcs measurement references. It cannot occur as shown during a valid command sequence. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 37 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Figure 5. Program Operation Timings Program Command Sequence (last 2 cycles) tAS tWC Addresses 0x555 Program Command Sequence (last 2 cycles) tAH PA PA PA CE# tGHWL OE# tCH tWP WE# tWPH tCS Data RY/BY# PD OxA0 tDS tWHWH1 tDH Status DOUT tBUSY tRB tVCS VCC Notes: 1. PA=Program Address, PD=Program Data, DOUT is the true data at the program address. 2. VCC shown in order to illustrate tVCS measurement references. It cannot occur as shown during a valid command sequence. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 38 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Figure 6. AC Waveforms for /DATA Polling During Embedded Algorithm Operations tRC Addresses VA VA VA tACC tCH tCE CE# tOE OE# tOEH tDF WE# tOH DQ[7] Complement Complement DQ[6:0] Status Data Status Data True Valid Data True Valid Data tBUS RY/BY# Notes: 1. VA=Valid Address for reading Data# Polling status data 2. This diagram shows the first status cycle after the command sequence, the last status read cycle and the array data read cycle. Figure 7. AC Waveforms for Toggle Bit During Embedded Algorithm Operations tRC Addresses VA VA VA VA tACC tCH tCE CE# tOE OE# tOEH WE# tDF tOH DQ6, DQ2 tBUSY Valid Status Valid Status Valid Status (first read) (second read) (stops toggling) Valid Data RY/BY# This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 39 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Figure 8. Alternate CE# Controlled Write Operation Timings 0x555 for Program 0x2AA for Erase PA for Program SA for Sector Erase 0x555 for Chip Erase Addresses VA tWC tAS tAH WE# tWH tGHEL OE# tCP tWS tCPH tCWHWH1 / tCWHWH2 / tCWHWH3 CE# tDS tBUSY tDH Status Data 0xA0 for Program 0x55 for Erase DOUT PD for Program 0x30 for Sector Erase 0x10 for Chip Erase RY/BY# tRH Reset# Notes: PA = address of the memory location to be programmed. PD = data to be programmed at byte address. VA = Valid Address for reading program or erase status Dout = array data read at VA Shown above are the last two cycles of the program or erase command sequence and the last status read cycle RESETt# shown to illustrate tRH measurement references. It cannot occur as shown during a valid command sequence. Figure 9. DQ2 vs. DQ6 Enter Embedded Erase WE# Enter Erase Suspend Program Erase Suspend Erase Enter Suspend Read Erase Resume Enter Suspend Program Erase Suspend Read Erase Erase Complete DQ6 DQ2 This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 40 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B AC CHARACTERISTICS Table 21. Temporary Sector Unprotect Parameter Std Description tVIDR VID Rise and Fall Time tVIHH VHH Rise and Fall Time RESET# Setup Time for Temporary Sector Unprotect(Note) tRSP Speed Option -70 Unit Min 500 ns Min 500 ns Min 4 µs Notes: Not 100% tested. Figure 10. Temporary Sector Unprotect Timing Diagram VID RESET# 0 or 3 V 0 or 3 V tVIDR tVIDR CE# WE# tRSP RY/BY# AC CHARACTERISTICS Write Protect / Accelerated Program Figure 11. Accelerated Program Timing Diagram VHH WP#/ACC 0 or 3 V 0 or 3 V tVHH tVHH CE# WE# tRSP AC CHARACTERISTICS Sector (Group) Protect and Chip Unprotect This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 41 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Figure 12. Sector (Group) Protect and Chip Unprotect Timing Diagram VID RESET# Vcc 0V 0V tVIDR tVIDR SA, A6,A1,A0 Data 60h Valid Valid Valid 60h 40h Status Sector Protect/Unprotect CE# WE# Verify >0.4µS >1µS Protect: 150 uS Unprotect: 15 mS OE# Notes: Use standard microprocessor timings for this device for read and write cycles. For Sector (Group) Protect, use A6=0, A1=1, A0=0. For Chip Unprotect, use A6=1, A1=1, A0=0. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 42 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Table 22. ERASE AND PROGRAM PERFORMANCE Parameter Typ Sector Erase Time Limits Max 0.1 2 Sec Chip Erase Time 8 70 Sec Byte Programming Time 8 200 µS Accelerated Byte/Word Program Time 7 200 µS Word Programming Time 8 200 µS Byte 33.6 100.8 Word 16.8 50.4 Chip Programming Time Erase/Program Endurance 100K Comments Unit Excludes 00h programming prior to erasure Excludes system level overhead Sec Cycles Minimum 100K cycles Notes: 1. Typical program and erase times assume the following conditions: room temperature, 3V and checkboard pattern programmed. 2. Maximum program and erase times assume the following conditions: worst case Vcc, 90 C and 100,000 cycles. Table 23. 48-PIN TSOP PACKAGE CAPACITANCE Parameter Symbol Parameter Description Test Setup Typ Max Unit CIN Input Capacitance VIN = 0 6 7.5 pF COUT Output Capacitance VOUT = 0 8.5 12 pF CIN2 Control Pin Capacitance VIN = 0 7.5 9 pF Note: Test conditions are Temperature = 25°C and f = 1.0 MHz. Table 24. DATA RETENTION Parameter Description Data Retention Time Test Conditions Min Unit 150°C 10 Years 125°C 20 Years This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 43 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B ABSOLUTE MAXIMUM RATINGS Parameter Value Storage Temperature -65 to +150 Plastic Packages -65 to +125 Ambient Temperature With Power Applied 1 C C -55 to +125 Output Short Circuit Current Voltage with Respect to Ground Unit C 200 mA A9, OE#, RESET# 2 and WP#/ACC -0.5 to +11.5 V All other pins 3 -0.5 to Vcc+0.5 V Vcc -0.5 to + 4.0 V Notes: 1. No more than one output shorted at a time. Duration of the short circuit should not be greater than one second. 2. Minimum DC input voltage on A9, OE#, RESET# and WP#/ACC pins is –0.5V. During voltage transitions, A9, OE#, RESET# and WP#/ACC pins may undershoot V ss to –1.0V for periods of up to 50ns and to –2.0V for periods of up to 20ns. See figure below. Maximum DC input voltage on A9, OE#, and RESET# is 11.5V which may overshoot to 12.5V for periods up to 20ns. 3. Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, inputs may undershoot V ss to –1.0V for periods of up to 50ns and to –2.0 V for periods of up to 20ns. See figure below. Maximum DC voltage on output and I/O pins is V cc + 0.5 V. During voltage transitions, outputs may overshoot to V cc + 1.5 V for periods up to 20ns. See figure below. 4. Stresses above the values so mentioned above may cause permanent damage to the device. These values are for a stress rating only and do not imply that the device should be operated at conditions up to or above these values. Exposure of the device to the maximum rating values for extended periods of time may adversely affect the device reliability. B B B B B B B B RECOMMENDED OPERATING RANGES 1 P P Parameter Value Ambient Operating Temperature Industrial Devices Operating Supply Voltage Vcc 1. -40 to 85 Full Voltage Range: 2.7 to 3.6V Unit C V Recommended Operating Ranges define those limits between which the functionality of the device is guaranteed. Vcc +1.5V V Maximum Negative Overshoot Waveform Maximum Positive Overshoot Waveform This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 44 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B FIGURE 13. 48L TSOP 12mm x 20mm package outline This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 45 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B FIGURE 14. 48L TFBGA 6mm x 8mm package outline SYMBOL DIMENSION IN MM MIN. NOR MAX A --- --- 1.30 A1 0.23 0.29 --- A2 0.84 0.91 --- D 7.90 8.00 8.10 E 5.90 6.00 6.10 D1 --- 5.60 --- E1 --- 4.00 --- e --- 0.80 --- b 0.35 0.40 Note : 1. Coplanarity: 0.1 mm 0.45 This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 46 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Purpose Eon Silicon Solution Inc. (hereinafter called “Eon”) is going to provide its products’ top marking on ICs with < cFeon > from January 1st, 2009, and without any change of the part number and the compositions of the ICs. Eon is still keeping the promise of quality for all the products with the same as that of Eon delivered before. Please be advised with the change and appreciate your kindly cooperation and fully support Eon’s product family. Eon products’ New Top Marking cFeon Top Marking Example: cFeon Part Number: XXXX-XXX Lot Number: XXXXX Date Code: XXXXX For More Information Please contact your local sales office for additional information about Eon memory solutions. This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 47 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B ORDERING INFORMATION EN29LV320B T 70 T I P PACKAGING CONTENT (Blank) = Conventional P = RoHS compliant TEMPERATURE RANGE I = Industrial (-40°C to +85°C) PACKAGE T = 48-pin TSOP B = 48-Ball Thin Fine Pitch Ball Grid Array (TFBGA) 0.80mm pitch, 6mm x 8mm package SPEED 70 = 70ns BOOT CODE SECTOR ARCHITECTURE T = Top boot Sector B = Bottom boot Sector BASE PART NUMBER EN = EON Silicon Solution Inc. 29LV = FLASH, 3V Read, Program and Erase 320 = 32 Megabit (4M x 8 / 2M x 16) B = version identifier This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 48 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com EN29LV320B Revisions List Revision No Description Date A 2009/1/14 Initial Release This Data Sheet may be revised by subsequent versions © 2004 Eon Silicon Solution, Inc., 49 or modifications due to changes in technical specifications. Rev. A, Issue Date: 2009/01/14 www.eonssi.com