SafeSite® LED Linear Fixture - UL 844

Patent Pending
SafeSite® LED Linear Fixture - UL 844
for Indoor and Outdoor Hazardous Locations
Application
Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting
fixtures in industrial applications and hazardous location applications.
SafeSite LED Linear Fixture
®
Low Profile - Class I, Div. 2 / Class II
The SafeSite LED Linear fixture’s rugged solid state design makes it highly
resistant to shock and vibration. Its fully gasketed IP66/67 rated enclosure
makes it suitable for dust & wet locations, its 1598A rating guarantees added
protection from salt water spray. The SafeSite LED Linear’s superior design
allows for wiring and mounting versatility and ease of installation for many
lighting applications.
Mechanical Information
Fixture Weight:
4’ - 10 lbs (4.53 kg)
2’ - 7 lbs (3.18 kg)
Shipping Weight:
4’ - 11 lbs (4.99 kg)
2’ - 8 lbs (3.63 kg)
Mounting:
(4) 3/4” NPT openings
Optional swivel bracket - LPXW4
Optional low profile bracket - LPXW4LP
Electrical Specifications
Dimensions in Inches [mm]
Certifications & Ratings
• Class I Div. 2 Groups A, B, C, D
• Class II Div. 1 Groups E, F, G
• Class II Div. 2 Groups F, G
• Class III
• UL 1598/A
• UL 844
• UL 8750
• CSA C22.2 No.137
• CSA C22.2 No.250
• IP66/67
• NEMA 4X
Features & Benefits
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5 year full performance warranty
L70 rated for >100,000 hours @ 25°C
DLC Listed (80 CRI CW & NW models only)
Low profile housing for limited space applications
Dual NPT entries for in / out wiring
Thru wiring capability
Instant on/off operation
Resistant to water, salt, dust & vibration
Resistant up to 20 PSI of hose directed water
Universal input (100-277V AC), 50/60Hz
Mercury free
Temperature compensation technology for longer life
Factory sealed
Integrated wiring box
Light Distribution
Operating Voltage:
100 - 277V AC 50/60Hz
Power Consumption:
Operating Temp:
See ordering information
-40°F to +149°F (-40°C to +65°C)
Harmonics:
IEC 61000-3-2
Noise Requirements/
EMC:
FCC Title 47, Subpart B, Section 15, class
A device. RF Immunity; 10V/m, 80MHz-1GHz
Surge Protection
EN 61000-4-5
4 kV line to line
4 kV line to ground
THD:
< 20%
Power Factor:
> 0.9
Construction
Finish:
Superior dual coat finish
Sealed polyester topcoat
Chemical-resistant epoxy primer
Lens:
Polycarbonate
Photometric Information
CRI:
75, 80
CCT:
5000K (cool white)
4000K (neutral white)
IES Files:
Available at www.dialight.com
All values typical unless otherwise stated
All lumen values are typical (tolerance +/- 10%)
Temperature Ratings
Ambient Temperature Range
T4A Temperature Code
Ambient Temperature Range
T5 Temperature Code
-40°F to +149°F (-40°C to +65°C)
-40°F to +113°F (-40°C to +45°C)
Mounting Options
LPXW4LP
2
Side Mount - LPXW4
www.dialight.com
Top Mount - LPXW4
SafeSite® LED Linear Fixture
Class I Div. 2 Ordering Information
Part Number
Length
Type
CRI
CID1
CID2
LPD3C4M2P
4’
Low Profile
75
•
LPD3C4H2D
4’
Low Profile
75
•
CIID1
CIID2
CIII
Lens
CCT
Fixture
Lumens
Watt
LPW
Optical
Pattern
100-277V AC
Clear
5000K (cool white)
7,250
66
110
circular
100-277V AC
Textured
5000K (cool white)
6,900
66
105
circular
Voltage
LPD3C4H2W
4’
Low Profile
75
•
100-277V AC
Diffused
5000K (cool white)
6,700
66
102
circular
LPD3B4M2P
4’
Low Profile
80
•
100-277V AC
Clear
5000K (cool white)
6,500
66
98
circular
LPD3B4H2D
4’
Low Profile
80
•
100-277V AC
Textured
5000K (cool white)
6,200
66
94
circular
LPD3B4H2W
4’
Low Profile
80
•
100-277V AC
Diffused
5000K (cool white)
6,000
66
91
circular
LPD3C4D2P
2’
Low Profile
75
•
100-277V AC
Clear
5000K (cool white)
3,600
33
109
circular
LPD3C4B2D
2’
Low Profile
75
•
100-277V AC
Textured
5000K (cool white)
3,400
33
103
circular
LPD3C4B2W
2’
Low Profile
75
•
100-277V AC
Diffused
5000K (cool white)
3,300
33
100
circular
LPD3B4D2P
2’
Low Profile
80
•
100-277V AC
Clear
5000K (cool white)
3,200
33
97
circular
LPD3B4B2D
2’
Low Profile
80
•
100-277V AC
Textured
5000K (cool white)
3,000
33
91
circular
LPD3B4B2W
2’
Low Profile
80
•
100-277V AC
Diffused
5000K (cool white)
2,900
33
88
circular
Class II Ordering Information
Part
Number
Length
Type
CRI
LPF3C4M2P
4’
Low Profile
75
CID1
CID2
CIID1
CIID2
CIII
Voltage
Lens
CCT
Fixture
Lumens
Watt
LPW
Optical
Pattern
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
7,000
66
106
circular
LPF3C4H2D
4’
Low Profile
75
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
6,600
66
100
circular
LPF3B4M2P
4’
Low Profile
80
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
6,300
66
95
circular
LPF3B4H2D
4’
Low Profile
80
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
6,000
66
91
circular
LPF3C4D2P
2’
Low Profile
75
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
3,500
33
106
circular
LPF3C4B2D
2’
Low Profile
75
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
3,300
33
100
circular
LPF3B4D2P
2’
Low Profile
80
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
3,100
33
94
circular
LPF3B4B2D
2’
Low Profile
80
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
2,900
33
88
circular
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSD3C4MEP becomes LSD3N4MEP
2
450 Lumens in Battery Backup mode
3
All lumen values are typical (tolerance +/- 10%)
4
See application note on page 3 regarding “sustained” and “maintained” battery modes
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC
Low Profile Models - Class I, Div. 2 / Class II
Part Number
Material
Description
Kit Includes
LPXW4
316
Stainless Steel
Mounting bracket
Can be angled at 0°, 30°, 45°, 60° & 90°
Mounting bracket
Mounting hardware
LPXW4LP
316
Stainless Steel
Low profile mounting bracket
Can be angled at 0° and 15°
Mounting bracket
Mounting hardware
LTXENDCAPKIT
304
Stainless Steel
Chain mount and secondary retention bracket
2 Brackets
Mounting hardware
LTXSAFEKIT
304
Stainless Steel
Safety Cable Kit for secondary retention
2 brackets
2 53” Safety cables
Mounting hardware
www.dialight.com
3
Application
The first of its kind, Dialight’s SafeSite® LED linear fixture replaces HID and
fluorescent lighting fixtures in industrial applications and hazardous location
applications.
SafeSite® LED Linear Fixture
Top Conduit Mount- Class I, Div. 2 / Class II
The SafeSite LED Linear fixture’s rugged solid state design makes it highly
resistant to shock and vibration. Its fully gasketed IP66 rated enclosure makes
it suitable for dust & wet locations, its 1598A rating guarantees added protection
from salt water spray. The SafeSite LED Linear’s superior design allows for
mounting versatility and ease of installation for many lighting applications.
Mechanical Information
Bracket not included
Dimensions in Inches [mm]
Certifications & Ratings
• Class I Div. 2 Groups A, B, C, D
• Class II Div. 1 Groups E, F, G
• Class II Div. 2 Groups F, G
• Class III
• UL 1598/A
• UL 844
• UL 8750
• CSA C22.2 No.137
• CSA C22.2 No.250
• IP66
• NEMA 4X
4’ - 11 lbs (4.99 kg)
2’ - 10 lbs (4.53 kg)
Shipping Weight:
4’ -13 lbs (5.90 kg)
2’ - 12 lbs (5.44 kg)
Mounting:
(3) 3/4” NPT openings
Optional swivel bracket - LTXW4
Optional low profile bracket - LTXW4LP
Electrical Specifications
Operating Voltage:
100 - 277V AC 50/60Hz
Power Consumption:
Operating Temp:
See ordering information
-40°F to +149°F (-40°C to +65°C)
Harmonics:
IEC 61000-3-2
Noise Requirements/
EMC:
Surge Protection
Features & Benefits
•
•
•
•
•
•
•
•
•
•
•
•
Fixture Weight:
5 year full performance warranty
L70 rated for >100,000 hours @ 25°C
DLC Listed (80 CRI CW & NW models only)
Instant on/off operation
Resistant to water, salt, dust & vibration
Vibration tested to UL 844 for 35 hours @ 2,000 CPM
Resistant up to 20 PSI of hose directed water
Universal input (100-277V AC), 50/60Hz
Mercury free
Temperature compensation technology for longer life
Factory sealed
Integrated wiring box
FCC Title 47, Subpart B, Section 15, class
A device. RF Immunity; 10V/m, 80MHz-1GHz
EN 61000-4-5
4 kV line to line
4 kV line to ground
THD:
< 20%
Power Factor:
> 0.9
Construction
Finish:
Superior dual coat finish
Sealed polyester topcoat
Chemical-resistant epoxy primer
Lens:
Polycarbonate
Photometric Information
Light Distribution
CRI:
75,80
CCT:
5000K (cool white)
4000K (neutral white)
IES Files:
Available at www.dialight.com
All values typical unless otherwise stated
All lumen values are typical (tolerance +/- 10%)
Temperature Ratings
Ambient Temperature Range
T4A Temperature Code
Ambient Temperature Range
T5 Temperature Code
-40°F to +149°F (-40°C to +65°C)
-40°F to +113°F (-40°C to +45°C)
Mounting Options
Conduit Top Mount
4
Conduit Side Mount
www.dialight.com
LTXW4
LTXW4LP
SafeSite® LED Linear Fixture
Class I Div. 2 Ordering Information
Voltage
Lens
CCT
Fixture
Lumens
Watt
LPW
Optical
Pattern
•
100-277V AC
Clear
5000K (cool white)
7,250
66
110
circular
75
•
100-277V AC
Textured
5000K (cool white)
6,900
66
105
circular
75
•
100-277V AC
Diffused
5000K (cool white)
6,700
66
102
circular
Part Number
Length
Type
CRI
LTD3C4M2P
4’
Top Conduit
75
LTD3C4H2D
4’
Top Conduit
LTD3C4H2W
4’
Top Conduit
CID1
CID2
CIID1
CIID2
CIII
LTD3B4M2P
4’
Top Conduit
80
•
100-277V AC
Clear
5000K (cool white)
6,500
66
98
circular
LTD3B4H2D
4’
Top Conduit
80
•
100-277V AC
Textured
5000K (cool white)
6,200
66
94
circular
LTD3B4H2W
4’
Top Conduit
80
•
100-277V AC
Diffused
5000K (cool white)
6,000
66
91
circular
LTD3C4D2P
2’
Top Conduit
75
•
100-277V AC
Clear
5000K (cool white)
3,600
33
109
circular
LTD3C4B2D
2’
Top Conduit
75
•
100-277V AC
Textured
5000K (cool white)
3,400
33
103
circular
LTD3C4B2W
2’
Top Conduit
75
•
100-277V AC
Diffused
5000K (cool white)
3,300
33
100
circular
circular
LTD3B4D2P
2’
Top Conduit
80
•
100-277V AC
Clear
5000K (cool white)
3,200
33
97
LTD3B4B2D
2’
Top Conduit
80
•
100-277V AC
Textured
5000K (cool white)
3,000
33
91
circular
LTD3B4B2W
2’
Top Conduit
80
•
100-277V AC
Diffused
5000K (cool white)
2,900
33
88
circular
CCT
Fixture
Lumens
Watt
LPW
Optical
Pattern
Class II Ordering Information
Part
Number
Length
Type
CRI
CID1
CID2
CIID1
CIID2
CIII
Voltage
Lens
LTF3C4M2P
4’
Top Conduit
75
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
7,000
66
106
circular
LTF3C4H2D
4’
Top Conduit
75
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
6,600
66
100
circular
LTF3B4M2P
4’
Top Conduit
80
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
6,300
66
95
circular
LTF3B4H2D
4’
Top Conduit
80
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
6,000
66
91
circular
LTF3C4D2P
2’
Top Conduit
75
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
3,500
33
106
circular
LTF3C4B2D
2’
Top Conduit
75
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
3,300
33
100
circular
LTF3B4D2P
2’
Top Conduit
80
E/F/G
F/G
•
100 - 277V AC
Clear
5000K (cool white)
3,100
33
94
circular
LTF3B4B2D
2’
Top Conduit
80
E/F/G
F/G
•
100 - 277V AC
Diffused
5000K (cool white)
2,900
33
88
circular
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LTF3C4D2P becomes LTF3N4D2P
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC
Top Conduit Mount Models - Class I, Div. 2 / Class II
Part Number
Material
Description
Kit Includes
LTXW4LP
5052
Aluminum
Low profile mounting bracket
Can be angled at 0° and 15°
Mounting bracket
Mounting hardware
LTXW4
6061
Aluminum
Mounting bracket
Can be angled at 0°, 30°, 45°, 60° & 90°
Mounting bracket
Mounting hardware
LTXENDCAPKIT
304
Stainless Steel
Chain mount and secondary retention bracket
2 Brackets
Mounting hardware
LTXSAFEKIT
304
Stainless Steel
Safety Cable Kit for secondary retention
2 brackets
2 53” Safety cables
Mounting hardware
LTXLSXW4
6061
Aluminum
Retrofit bracket adapter
(used to connect LTM model fixtures to an existing
LSXW4 bracket)
2 Bracket adapters
Mounting hardware
www.dialight.com
5
Application:
Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting
fixtures in industrial and hazardous applications. The SafeSite® LED Linear
fixture’s rugged solid state design makes it highly resistant to shock and
vibration. Its fully gasketed IP66 rated enclosure makes it suitable for dusty &
wet locations. The SafeSite LED Linear’s superior design allows for mounting
versatility and ease of installation for many lighting applications.
SafeSite LED Linear Fixture
®
Battery Backup - Class I, Div. 2 / Class II
This fixture is offered in sustained and maintained configurations.
Sustained has a single AC input and battery backup mode is entered
upon any loss of power. Fixture cannot be turned off without entering
battery backup mode. Maintained has two AC inputs. The fixture can be
turned on and off via AC-1 and Fixture only enters battery backup mode
when AC-2 is lost or low.
Mechanical Information
Fixture Weight:
18.0 lbs (8.16 kg)
Shipping Weight:
21.0 lbs (9.53 kg)
Mounting:
(1) Threaded 3/4” NPT Side
(2) Threaded 3/4” NPT Ends
Electrical specifications:
Operating Voltage:
100-277V AC 50/60 Hz
Power Consumption:
85W
-20°F to +149°F (-20°C to +65°C)
Operating Temp:
Battery:
3.6V 10Ah NiMH
Certifications
Expected Battery Life:
4 years
•
•
•
•
•
•
•
•
•
•
•
Battery Duration:
>3 hours
Harmonics:
IEC 61000-3-2
Dimensions in Inches [mm]
Class I, Division 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
UL1598/A
UL 844
UL 924
CSA C22.2 #250.0
CSA C22.2 No.137
IP66
NEMA 4X
Noise Requirements/
EMC:
Surge Protection
Features & Benefits
•
•
•
•
•
•
•
•
•
•
5 year full performance warranty (excluding batteries)
L70 rated for >100,000 hours @ 25°C
450 lumens in battery backup mode consistent throughout life of battery
Low power consumption
Battery status indication light
Instant on/off operation
Superior color rendition index compared to HPS, LPS, MV
Mercury free
Resistant to shock and vibration
Temperature compensation technology for longer life
Light Distribution
FCC Title 47, Subpart B, Section 15, class
A device. RF Immunity; 10V/m,
80MHz-1GHz
EN 61000-4-5
1 kV line to line, 2 kV line to ground
THD:
< 20%
Power Factor:
> 0.9
Construction
Finish:
Superior dual coat finish
Sealed polyester topcoat
Chemical-resistant epoxy primer
Lens:
Polycarbonate
Photometric Information
CRI:
75
CCT:
5000K (cool white)
IES Files:
available at www.dialight.com
All values typical unless otherwise state
All lumen values are typical (tolerance +/- 10%)
Temperature Ratings
Ambient Temperature Range
T4A Temperature Code
Ambient Temperature Range
T5 Temperature Code
-20°F to +149°F (-20°C to +65°C)
-20°F to +113°F (-20°C to +45°C)
Mounting Options
In-line Conduit Mount
6
Overhead Conduit Mount
www.dialight.com
LSXW4
SafeSite® LED Linear Fixture
Class I Div. 2 Ordering Information
Part Number1 Length
1
Type
CRI
CID1
CID2
CIID1
CIID2
CIII
Voltage
Lens
CCT
Fixture
Lumens
Watt
LPW
LSD3C4MEP
4’
Sustained
75
•
•
100 - 277V AC
Clear 5000K (cool white)
7,000
85
85
LSD3C4MNP
4’
Maintained
75
•
•
100 - 277V AC
Clear 5000K (cool white)
7,000
85
85
Fixture
Lumens
Watt
LPW
Class II Ordering Information
Part
Number1
Length
Type
CRI
CID1
CID2
CIID1
CIID2
CIII
Voltage
Lens
CCT
LSF3C4MEP
4’
Sustained
75
E/F/G F/G
•
100 - 277V AC
Clear 5000K (cool white)
7,000
85
85
LSF3C4MNP
4’
Maintained
75
E/F/G F/G
•
100 - 277V AC
Clear 5000K (cool white)
7,000
85
85
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSF3C4D2P becomes LSF3N4D2P
2
450 Lumens in Battery Backup mode
3
Expect a 10% reduction in Lumens for 80 CRI minimum fixtures
4
All lumen values are typical (tolerance +/- 10%)
5
See application note on page 6 regarding “sustained” and “maintained” battery modes
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC
Battery Back up Models - Class I, Div. 2 / Class II
Part Number
Material
Description
Kit Includes
LSXW4
6061
Aluminum
Mounting bracket
Can be angled at 0°, 30°, 45°, 60° & 90°
Mounting bracket
Mounting hardware
LSXENDCAPKIT
304
Stainless Steel
Chain mount brackets
2 Mounting brackets
Mounting hardware
HZXSAFEKIT
316
Stainless Steel
Safety Cable Kit
2 Eyelets
2 53” Safety cables
Mounting hardware
www.dialight.com
7
Application
The first of its kind, the Dialight SafeSite® LED linear luminaire was designed
specifically to replace HID and fluorescent lighting fixtures in industrial and
hazardous location applications. The SafeSite LED Linear fixture’s rugged solid
state design makes it highly resistant to shock and vibration , while it’s superior
design allows for increased mounting versatility and ease of installation.
Mechanical Information
SafeSite® LED Linear Fixture
Class I, Div. 1
47.46
(1205,4)
Fixture Weight:
4’ - 26.0 lbs (11.79 kg)
2’ - 17.5 lbs (7.94 kg)’
Shipping Weight:
4’ - 28.0 lbs (12.70 kg)
2’ - 19.5 lbs (8.85 kg)
Mounting:
(1) Threaded 3/4” NPT Side
(2) Threaded 3/4” NPT Ends
Electrical specifications:
25.56
(649,1)
4.25
(108)
6.98
(177,4)
Operating Voltage:
100 - 277V AC 50/60Hz or
347 - 480V AC 50/60Hz
Power Consumption:
See ordering information
Operating Temp:
-40°F to +149°F (-40°C to +65°C)
Harmonics:
IEC 61000-3-2
Noise Requirements/
EMC:
FCC Title 47, Subpart B, Section 15, class
A device. RF Immunity; 10V/m, 80MHz-1GHz
Dimensions in Inches [mm]
Surge Protection
EN 61000-4-5
4 kV line to line
4 kV line to ground
THD:
< 20%
Power Factor:
> 0.9
Certifications
•
•
•
•
•
•
•
•
Class I, Div 1 Groups C, D
UL 844
UL1598
CSA 22.2 No.137
UL 8750
ABS Design Assessed: # 12-HS942957-PDA
IP66
NEMA 4X
Construction
Finish:
Superior dual coat finish
Sealed polyester topcoat
Chemical-resistant epoxy primer
Lens:
Glass
Photometric Information
Light Distribution
CRI:
75
CCT:
5000K Cool White
IES Files:
Available upon request
All values typical unless otherwise state
All lumen values are typical (tolerance +/- 10%)
Temperature Ratings
LSC3C4M3GEX (4ft)
Ambient Temperature Range
T4a Temperature Code
LSC3C4D3GEX (2ft)
Ambient Temperature Range
T5 Temperature Code
-40°F to +149°F (-40°C to +65°C)
-40°F to +149°F (-40°C to +65°C)
Mounting Options
Conduit Top Mount
8
Conduit Side Mount
www.dialight.com
LSXW5
SafeSite® LED Linear Fixture
Class I Div. 1 Ordering Information
Part Number1
Length
Voltage
Lens
Fixture Lumens
Watt
Lumens Per Watt
LSC3C4M3GEX
4’
100 - 277V AC
LSC3C5M3GEX
Clear
7,000
66
106
4’
347 - 480V AC
Clear
7,250
78
93
LSC3C4D3GEX
2’
100 - 277V AC
Clear
3,500
33
106
LSC3C5D3GEX
2’
347 - 480V AC
Clear
3,600
39
92
Class I, Div 1
Notes:
1
Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSC3C4D3GEX becomes LSC3N4D3GEX
For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC
Standard Models - Class I, Div 1
Part Number
Material
Description
Kit Includes
LSXW5
6061
Aluminum
Mounting bracket
Can be angled at 0°, 30°, 45°, 60° & 90°
Mounting bracket
Mounting hardware
HZXSAFEKIT
316
Stainless Steel
Safety Cable Kit
2 Eyelets
2 53” Safety cables
Mounting hardware
Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: www.
dialight.com/Assets/Brochures_And_Catalogs/Illumination/MDTFSLINX001.pdf. Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW],
DIALIGHT DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE,
TITLE, AND NONINFRINGEMENT.
www.dialight.com
MDTFSLINX001_M
SafeSite® LED Linear Fixture - UL 844
for Indoor and Outdoor Hazardous Locations