Patent Pending SafeSite® LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations Application Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting fixtures in industrial applications and hazardous location applications. SafeSite LED Linear Fixture ® Low Profile - Class I, Div. 2 / Class II The SafeSite LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration. Its fully gasketed IP66/67 rated enclosure makes it suitable for dust & wet locations, its 1598A rating guarantees added protection from salt water spray. The SafeSite LED Linear’s superior design allows for wiring and mounting versatility and ease of installation for many lighting applications. Mechanical Information Fixture Weight: 4’ - 10 lbs (4.53 kg) 2’ - 7 lbs (3.18 kg) Shipping Weight: 4’ - 11 lbs (4.99 kg) 2’ - 8 lbs (3.63 kg) Mounting: (4) 3/4” NPT openings Optional swivel bracket - LPXW4 Optional low profile bracket - LPXW4LP Electrical Specifications Dimensions in Inches [mm] Certifications & Ratings • Class I Div. 2 Groups A, B, C, D • Class II Div. 1 Groups E, F, G • Class II Div. 2 Groups F, G • Class III • UL 1598/A • UL 844 • UL 8750 • CSA C22.2 No.137 • CSA C22.2 No.250 • IP66/67 • NEMA 4X Features & Benefits • • • • • • • • • • • • • • 5 year full performance warranty L70 rated for >100,000 hours @ 25°C DLC Listed (80 CRI CW & NW models only) Low profile housing for limited space applications Dual NPT entries for in / out wiring Thru wiring capability Instant on/off operation Resistant to water, salt, dust & vibration Resistant up to 20 PSI of hose directed water Universal input (100-277V AC), 50/60Hz Mercury free Temperature compensation technology for longer life Factory sealed Integrated wiring box Light Distribution Operating Voltage: 100 - 277V AC 50/60Hz Power Consumption: Operating Temp: See ordering information -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz Surge Protection EN 61000-4-5 4 kV line to line 4 kV line to ground THD: < 20% Power Factor: > 0.9 Construction Finish: Superior dual coat finish Sealed polyester topcoat Chemical-resistant epoxy primer Lens: Polycarbonate Photometric Information CRI: 75, 80 CCT: 5000K (cool white) 4000K (neutral white) IES Files: Available at www.dialight.com All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%) Temperature Ratings Ambient Temperature Range T4A Temperature Code Ambient Temperature Range T5 Temperature Code -40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C) Mounting Options LPXW4LP 2 Side Mount - LPXW4 www.dialight.com Top Mount - LPXW4 SafeSite® LED Linear Fixture Class I Div. 2 Ordering Information Part Number Length Type CRI CID1 CID2 LPD3C4M2P 4’ Low Profile 75 • LPD3C4H2D 4’ Low Profile 75 • CIID1 CIID2 CIII Lens CCT Fixture Lumens Watt LPW Optical Pattern 100-277V AC Clear 5000K (cool white) 7,250 66 110 circular 100-277V AC Textured 5000K (cool white) 6,900 66 105 circular Voltage LPD3C4H2W 4’ Low Profile 75 • 100-277V AC Diffused 5000K (cool white) 6,700 66 102 circular LPD3B4M2P 4’ Low Profile 80 • 100-277V AC Clear 5000K (cool white) 6,500 66 98 circular LPD3B4H2D 4’ Low Profile 80 • 100-277V AC Textured 5000K (cool white) 6,200 66 94 circular LPD3B4H2W 4’ Low Profile 80 • 100-277V AC Diffused 5000K (cool white) 6,000 66 91 circular LPD3C4D2P 2’ Low Profile 75 • 100-277V AC Clear 5000K (cool white) 3,600 33 109 circular LPD3C4B2D 2’ Low Profile 75 • 100-277V AC Textured 5000K (cool white) 3,400 33 103 circular LPD3C4B2W 2’ Low Profile 75 • 100-277V AC Diffused 5000K (cool white) 3,300 33 100 circular LPD3B4D2P 2’ Low Profile 80 • 100-277V AC Clear 5000K (cool white) 3,200 33 97 circular LPD3B4B2D 2’ Low Profile 80 • 100-277V AC Textured 5000K (cool white) 3,000 33 91 circular LPD3B4B2W 2’ Low Profile 80 • 100-277V AC Diffused 5000K (cool white) 2,900 33 88 circular Class II Ordering Information Part Number Length Type CRI LPF3C4M2P 4’ Low Profile 75 CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCT Fixture Lumens Watt LPW Optical Pattern E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 7,000 66 106 circular LPF3C4H2D 4’ Low Profile 75 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 6,600 66 100 circular LPF3B4M2P 4’ Low Profile 80 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 6,300 66 95 circular LPF3B4H2D 4’ Low Profile 80 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91 circular LPF3C4D2P 2’ Low Profile 75 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 3,500 33 106 circular LPF3C4B2D 2’ Low Profile 75 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100 circular LPF3B4D2P 2’ Low Profile 80 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 3,100 33 94 circular LPF3B4B2D 2’ Low Profile 80 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 2,900 33 88 circular Notes: 1 Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSD3C4MEP becomes LSD3N4MEP 2 450 Lumens in Battery Backup mode 3 All lumen values are typical (tolerance +/- 10%) 4 See application note on page 3 regarding “sustained” and “maintained” battery modes For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC Low Profile Models - Class I, Div. 2 / Class II Part Number Material Description Kit Includes LPXW4 316 Stainless Steel Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware LPXW4LP 316 Stainless Steel Low profile mounting bracket Can be angled at 0° and 15° Mounting bracket Mounting hardware LTXENDCAPKIT 304 Stainless Steel Chain mount and secondary retention bracket 2 Brackets Mounting hardware LTXSAFEKIT 304 Stainless Steel Safety Cable Kit for secondary retention 2 brackets 2 53” Safety cables Mounting hardware www.dialight.com 3 Application The first of its kind, Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting fixtures in industrial applications and hazardous location applications. SafeSite® LED Linear Fixture Top Conduit Mount- Class I, Div. 2 / Class II The SafeSite LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration. Its fully gasketed IP66 rated enclosure makes it suitable for dust & wet locations, its 1598A rating guarantees added protection from salt water spray. The SafeSite LED Linear’s superior design allows for mounting versatility and ease of installation for many lighting applications. Mechanical Information Bracket not included Dimensions in Inches [mm] Certifications & Ratings • Class I Div. 2 Groups A, B, C, D • Class II Div. 1 Groups E, F, G • Class II Div. 2 Groups F, G • Class III • UL 1598/A • UL 844 • UL 8750 • CSA C22.2 No.137 • CSA C22.2 No.250 • IP66 • NEMA 4X 4’ - 11 lbs (4.99 kg) 2’ - 10 lbs (4.53 kg) Shipping Weight: 4’ -13 lbs (5.90 kg) 2’ - 12 lbs (5.44 kg) Mounting: (3) 3/4” NPT openings Optional swivel bracket - LTXW4 Optional low profile bracket - LTXW4LP Electrical Specifications Operating Voltage: 100 - 277V AC 50/60Hz Power Consumption: Operating Temp: See ordering information -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: Surge Protection Features & Benefits • • • • • • • • • • • • Fixture Weight: 5 year full performance warranty L70 rated for >100,000 hours @ 25°C DLC Listed (80 CRI CW & NW models only) Instant on/off operation Resistant to water, salt, dust & vibration Vibration tested to UL 844 for 35 hours @ 2,000 CPM Resistant up to 20 PSI of hose directed water Universal input (100-277V AC), 50/60Hz Mercury free Temperature compensation technology for longer life Factory sealed Integrated wiring box FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz EN 61000-4-5 4 kV line to line 4 kV line to ground THD: < 20% Power Factor: > 0.9 Construction Finish: Superior dual coat finish Sealed polyester topcoat Chemical-resistant epoxy primer Lens: Polycarbonate Photometric Information Light Distribution CRI: 75,80 CCT: 5000K (cool white) 4000K (neutral white) IES Files: Available at www.dialight.com All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%) Temperature Ratings Ambient Temperature Range T4A Temperature Code Ambient Temperature Range T5 Temperature Code -40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C) Mounting Options Conduit Top Mount 4 Conduit Side Mount www.dialight.com LTXW4 LTXW4LP SafeSite® LED Linear Fixture Class I Div. 2 Ordering Information Voltage Lens CCT Fixture Lumens Watt LPW Optical Pattern • 100-277V AC Clear 5000K (cool white) 7,250 66 110 circular 75 • 100-277V AC Textured 5000K (cool white) 6,900 66 105 circular 75 • 100-277V AC Diffused 5000K (cool white) 6,700 66 102 circular Part Number Length Type CRI LTD3C4M2P 4’ Top Conduit 75 LTD3C4H2D 4’ Top Conduit LTD3C4H2W 4’ Top Conduit CID1 CID2 CIID1 CIID2 CIII LTD3B4M2P 4’ Top Conduit 80 • 100-277V AC Clear 5000K (cool white) 6,500 66 98 circular LTD3B4H2D 4’ Top Conduit 80 • 100-277V AC Textured 5000K (cool white) 6,200 66 94 circular LTD3B4H2W 4’ Top Conduit 80 • 100-277V AC Diffused 5000K (cool white) 6,000 66 91 circular LTD3C4D2P 2’ Top Conduit 75 • 100-277V AC Clear 5000K (cool white) 3,600 33 109 circular LTD3C4B2D 2’ Top Conduit 75 • 100-277V AC Textured 5000K (cool white) 3,400 33 103 circular LTD3C4B2W 2’ Top Conduit 75 • 100-277V AC Diffused 5000K (cool white) 3,300 33 100 circular circular LTD3B4D2P 2’ Top Conduit 80 • 100-277V AC Clear 5000K (cool white) 3,200 33 97 LTD3B4B2D 2’ Top Conduit 80 • 100-277V AC Textured 5000K (cool white) 3,000 33 91 circular LTD3B4B2W 2’ Top Conduit 80 • 100-277V AC Diffused 5000K (cool white) 2,900 33 88 circular CCT Fixture Lumens Watt LPW Optical Pattern Class II Ordering Information Part Number Length Type CRI CID1 CID2 CIID1 CIID2 CIII Voltage Lens LTF3C4M2P 4’ Top Conduit 75 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 7,000 66 106 circular LTF3C4H2D 4’ Top Conduit 75 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 6,600 66 100 circular LTF3B4M2P 4’ Top Conduit 80 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 6,300 66 95 circular LTF3B4H2D 4’ Top Conduit 80 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 6,000 66 91 circular LTF3C4D2P 2’ Top Conduit 75 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 3,500 33 106 circular LTF3C4B2D 2’ Top Conduit 75 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 3,300 33 100 circular LTF3B4D2P 2’ Top Conduit 80 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 3,100 33 94 circular LTF3B4B2D 2’ Top Conduit 80 E/F/G F/G • 100 - 277V AC Diffused 5000K (cool white) 2,900 33 88 circular Notes: 1 Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LTF3C4D2P becomes LTF3N4D2P For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC Top Conduit Mount Models - Class I, Div. 2 / Class II Part Number Material Description Kit Includes LTXW4LP 5052 Aluminum Low profile mounting bracket Can be angled at 0° and 15° Mounting bracket Mounting hardware LTXW4 6061 Aluminum Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware LTXENDCAPKIT 304 Stainless Steel Chain mount and secondary retention bracket 2 Brackets Mounting hardware LTXSAFEKIT 304 Stainless Steel Safety Cable Kit for secondary retention 2 brackets 2 53” Safety cables Mounting hardware LTXLSXW4 6061 Aluminum Retrofit bracket adapter (used to connect LTM model fixtures to an existing LSXW4 bracket) 2 Bracket adapters Mounting hardware www.dialight.com 5 Application: Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting fixtures in industrial and hazardous applications. The SafeSite® LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration. Its fully gasketed IP66 rated enclosure makes it suitable for dusty & wet locations. The SafeSite LED Linear’s superior design allows for mounting versatility and ease of installation for many lighting applications. SafeSite LED Linear Fixture ® Battery Backup - Class I, Div. 2 / Class II This fixture is offered in sustained and maintained configurations. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode. Maintained has two AC inputs. The fixture can be turned on and off via AC-1 and Fixture only enters battery backup mode when AC-2 is lost or low. Mechanical Information Fixture Weight: 18.0 lbs (8.16 kg) Shipping Weight: 21.0 lbs (9.53 kg) Mounting: (1) Threaded 3/4” NPT Side (2) Threaded 3/4” NPT Ends Electrical specifications: Operating Voltage: 100-277V AC 50/60 Hz Power Consumption: 85W -20°F to +149°F (-20°C to +65°C) Operating Temp: Battery: 3.6V 10Ah NiMH Certifications Expected Battery Life: 4 years • • • • • • • • • • • Battery Duration: >3 hours Harmonics: IEC 61000-3-2 Dimensions in Inches [mm] Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III UL1598/A UL 844 UL 924 CSA C22.2 #250.0 CSA C22.2 No.137 IP66 NEMA 4X Noise Requirements/ EMC: Surge Protection Features & Benefits • • • • • • • • • • 5 year full performance warranty (excluding batteries) L70 rated for >100,000 hours @ 25°C 450 lumens in battery backup mode consistent throughout life of battery Low power consumption Battery status indication light Instant on/off operation Superior color rendition index compared to HPS, LPS, MV Mercury free Resistant to shock and vibration Temperature compensation technology for longer life Light Distribution FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz EN 61000-4-5 1 kV line to line, 2 kV line to ground THD: < 20% Power Factor: > 0.9 Construction Finish: Superior dual coat finish Sealed polyester topcoat Chemical-resistant epoxy primer Lens: Polycarbonate Photometric Information CRI: 75 CCT: 5000K (cool white) IES Files: available at www.dialight.com All values typical unless otherwise state All lumen values are typical (tolerance +/- 10%) Temperature Ratings Ambient Temperature Range T4A Temperature Code Ambient Temperature Range T5 Temperature Code -20°F to +149°F (-20°C to +65°C) -20°F to +113°F (-20°C to +45°C) Mounting Options In-line Conduit Mount 6 Overhead Conduit Mount www.dialight.com LSXW4 SafeSite® LED Linear Fixture Class I Div. 2 Ordering Information Part Number1 Length 1 Type CRI CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCT Fixture Lumens Watt LPW LSD3C4MEP 4’ Sustained 75 • • 100 - 277V AC Clear 5000K (cool white) 7,000 85 85 LSD3C4MNP 4’ Maintained 75 • • 100 - 277V AC Clear 5000K (cool white) 7,000 85 85 Fixture Lumens Watt LPW Class II Ordering Information Part Number1 Length Type CRI CID1 CID2 CIID1 CIID2 CIII Voltage Lens CCT LSF3C4MEP 4’ Sustained 75 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 7,000 85 85 LSF3C4MNP 4’ Maintained 75 E/F/G F/G • 100 - 277V AC Clear 5000K (cool white) 7,000 85 85 Notes: 1 Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSF3C4D2P becomes LSF3N4D2P 2 450 Lumens in Battery Backup mode 3 Expect a 10% reduction in Lumens for 80 CRI minimum fixtures 4 All lumen values are typical (tolerance +/- 10%) 5 See application note on page 6 regarding “sustained” and “maintained” battery modes For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC Battery Back up Models - Class I, Div. 2 / Class II Part Number Material Description Kit Includes LSXW4 6061 Aluminum Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware LSXENDCAPKIT 304 Stainless Steel Chain mount brackets 2 Mounting brackets Mounting hardware HZXSAFEKIT 316 Stainless Steel Safety Cable Kit 2 Eyelets 2 53” Safety cables Mounting hardware www.dialight.com 7 Application The first of its kind, the Dialight SafeSite® LED linear luminaire was designed specifically to replace HID and fluorescent lighting fixtures in industrial and hazardous location applications. The SafeSite LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration , while it’s superior design allows for increased mounting versatility and ease of installation. Mechanical Information SafeSite® LED Linear Fixture Class I, Div. 1 47.46 (1205,4) Fixture Weight: 4’ - 26.0 lbs (11.79 kg) 2’ - 17.5 lbs (7.94 kg)’ Shipping Weight: 4’ - 28.0 lbs (12.70 kg) 2’ - 19.5 lbs (8.85 kg) Mounting: (1) Threaded 3/4” NPT Side (2) Threaded 3/4” NPT Ends Electrical specifications: 25.56 (649,1) 4.25 (108) 6.98 (177,4) Operating Voltage: 100 - 277V AC 50/60Hz or 347 - 480V AC 50/60Hz Power Consumption: See ordering information Operating Temp: -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz Dimensions in Inches [mm] Surge Protection EN 61000-4-5 4 kV line to line 4 kV line to ground THD: < 20% Power Factor: > 0.9 Certifications • • • • • • • • Class I, Div 1 Groups C, D UL 844 UL1598 CSA 22.2 No.137 UL 8750 ABS Design Assessed: # 12-HS942957-PDA IP66 NEMA 4X Construction Finish: Superior dual coat finish Sealed polyester topcoat Chemical-resistant epoxy primer Lens: Glass Photometric Information Light Distribution CRI: 75 CCT: 5000K Cool White IES Files: Available upon request All values typical unless otherwise state All lumen values are typical (tolerance +/- 10%) Temperature Ratings LSC3C4M3GEX (4ft) Ambient Temperature Range T4a Temperature Code LSC3C4D3GEX (2ft) Ambient Temperature Range T5 Temperature Code -40°F to +149°F (-40°C to +65°C) -40°F to +149°F (-40°C to +65°C) Mounting Options Conduit Top Mount 8 Conduit Side Mount www.dialight.com LSXW5 SafeSite® LED Linear Fixture Class I Div. 1 Ordering Information Part Number1 Length Voltage Lens Fixture Lumens Watt Lumens Per Watt LSC3C4M3GEX 4’ 100 - 277V AC LSC3C5M3GEX Clear 7,000 66 106 4’ 347 - 480V AC Clear 7,250 78 93 LSC3C4D3GEX 2’ 100 - 277V AC Clear 3,500 33 106 LSC3C5D3GEX 2’ 347 - 480V AC Clear 3,600 39 92 Class I, Div 1 Notes: 1 Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSC3C4D3GEX becomes LSC3N4D3GEX For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC Standard Models - Class I, Div 1 Part Number Material Description Kit Includes LSXW5 6061 Aluminum Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware HZXSAFEKIT 316 Stainless Steel Safety Cable Kit 2 Eyelets 2 53” Safety cables Mounting hardware Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: www. dialight.com/Assets/Brochures_And_Catalogs/Illumination/MDTFSLINX001.pdf. Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT. www.dialight.com MDTFSLINX001_M SafeSite® LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations