Patent Pending SafeSite® LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations Application Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting fixtures in industrial applications and hazardous location applications. SafeSite® LED Linear Fixture Low Profile - Class I, Div. 2 / Class II The SafeSite LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration. Its fully gasketed IP 66 rated enclosure makes it suitable for dust & wet locations, its 1598A rating guarantees added protection from salt water spray. The SafeSite LED Linear’s superior design allows for wiring and mounting versatility and ease of installation for many lighting applications. Mechanical Information Fixture Weight: 4’ - 10 lbs (4.53 kg) 2’ - 7 lbs (3.18 kg) Shipping Weight: 4’ - 11 lbs (4.99 kg) 2’ - 8 lbs (3.63 kg) Mounting: (4) 3/4” NPT openings Optional swivel bracket - LPXW4 Optional low profile bracket - LPXW4LP Electrical Specifications Dimensions in Inches [mm] Certifications & Ratings • Class I Div. 2 Groups A, B, C, D • Class II Div. 1 Groups E, F, G • Class II Div. 2 Groups F, G • Class III Div. 1 • Class III Div. 2 • UL 1598/A • UL 844 • UL 8750 • CSA C22.2 No.137 • CSA C22.2 No.250 • IP 66/67 • NEMA 4X Features & Benefits • • • • • • • • • • • • • 5 year full performance warranty L70 rated for >100,000 hours @ 25°C Low profile housing for limited space applications Dual NPT entries for in / out wiring Thru wiring capability Instant on/off operation Resistant to water, salt, dust & vibration Resistant up to 20 PSI of hose directed water Universal input (100-277V AC), 50/60Hz Mercury free Temperature compensation technology for longer life Factory sealed Integrated wiring box Light Distribution Operating Voltage: 100 - 277V AC 50/60Hz Power Consumption: Operating Temp: See ordering information -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz Surge Protection EN 61000-4-5 4 kV line to line 4 kV line to ground THD: < 20% Power Factor: > 0.9 Construction Body: Powder coated aluminum Lens: Polycarbonate Photometric Information CRI: 75 CCT: 5,000K (cool white) IES Files: Available upon request All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%) *Consult factory for 80 min CRI Temperature Ratings Ambient Temperature Range T4A Temperature Code Ambient Temperature Range T5 Temperature Code -40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C) Mounting Options LPXW4LP 2 Side Mount - LPXW4 www.dialight.com Top Mount - LPXW4 Application The first of its kind, Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting fixtures in industrial applications and hazardous location applications. SafeSite® LED Linear Fixture Top Conduit Mount- Class I, Div. 2 / Class II The SafeSite LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration. Its fully gasketed IP 66 rated enclosure makes it suitable for dust & wet locations, its 1598A rating guarantees added protection from salt water spray. The SafeSite LED Linear’s superior design allows for mounting versatility and ease of installation for many lighting applications. Mechanical Information Fixture Weight: 4’ - 11 lbs (4.99 kg) 2’ - 10 lbs (4.53 kg) Shipping Weight: 4’ -13 lbs (5.90 kg) 2’ - 12 lbs (5.44 kg) Mounting: (3) 3/4” NPT openings Optional swivel bracket - LTXW4 Optional low profile bracket - LTXW4LP Electrical Specifications Bracket not included Dimensions in Inches [mm] Certifications & Ratings • Class I Div. 2 Groups A, B, C, D • Class II Div. 1 Groups E, F, G • Class II Div. 2 Groups F, G • Class III Div. 1 • Class III Div. 2 • UL 1598/A • UL 844 • UL 8750 • CSA C22.2 No.137 • CSA C22.2 No.250 • IP 66 • NEMA 4X 100 - 277V AC 50/60Hz Power Consumption: Operating Temp: See ordering information -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: Features & Benefits • • • • • • • • • • • Operating Voltage: 5 year full performance warranty L70 rated for >100,000 hours @ 25°C Instant on/off operation Resistant to water, salt, dust & vibration Vibration tested to UL 844 for 35 hours @ 2,000 CPM Resistant up to 20 PSI of hose directed water Universal input (100-277V AC), 50/60Hz Mercury free Temperature compensation technology for longer life Factory sealed Integrated wiring box FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz Surge Protection EN 61000-4-5 4 kV line to line 4 kV line to ground THD: < 20% Power Factor: > 0.9 Construction Body: Powder coated aluminum Lens: Polycarbonate Photometric Information Light Distribution CRI: 75 CCT: 5,000K (cool white) IES Files: Available upon request All values typical unless otherwise stated All lumen values are typical (tolerance +/- 10%) *Consult factory for 80 min CRI Temperature Ratings Ambient Temperature Range T4A Temperature Code Ambient Temperature Range T5 Temperature Code -40°F to +149°F (-40°C to +65°C) -40°F to +113°F (-40°C to +45°C) Mounting Options Conduit Top Mount Conduit Side Mount www.dialight.com LTXW4 LTXW4LP 3 Application: Dialight’s SafeSite® LED linear fixture replaces HID and fluorescent lighting fixtures in industrial and hazardous applications. The SafeSite® LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration. Its fully gasketed IP 66 rated enclosure makes it suitable for dusty & wet locations. The SafeSite LED Linear’s superior design allows for mounting versatility and ease of installation for many lighting applications. SafeSite® LED Linear Fixture Battery Backup - Class I, Div. 2 / Class II This fixture is offered in sustained and maintained configurations. Sustained has a single AC input and battery backup mode is entered upon any loss of power. Fixture cannot be turned off without entering battery backup mode. Maintained has two AC inputs. The fixture can be turned on and off via AC-1 and Fixture only enters battery backup mode when AC-2 is lost or low. Mechanical Information Fixture Weight: 18.0 lbs (8.16 kg) Shipping Weight: 21.0 lbs (9.53 kg) Mounting: (1) Threaded 3/4” NPT Side (2) Threaded 3/4” NPT Ends Electrical specifications: Dimensions in Inches [mm] Certifications • • • • • • • • • • • • Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III, Division 1 Class III, Division 2 UL1598/A UL 844 UL 924 CSA C22.2 #250.0 CSA C22.2 No.137 IP 66 NEMA 4X Operating Voltage: 100-277V AC 50/60 Hz Power Consumption: Operating Temp: 85W -20°F to +149°F (-20°C to +65°C) Battery: 3.6V 10Ah NiMH Expected Battery Life: 4 years Battery Duration: >3 hours Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: Surge Protection FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz EN 61000-4-5 1 kV line to line 2 kV line to ground - Features & Benefits • • • • • • • • • • 5 year full performance warranty (excludng batteries) L70 rated for >100,000 hours @ 25°C 450 lumens in battery backup mode consistent throughout life of battery Low power consumption Battery status indication light Instant on/off operation Superior color rendition index compared to HPS, LPS, MV Mercury free Resistant to shock and vibration Temperature compensation technology for longer life Light Distribution THD: < 20% Power Factor: > 0.9 Construction Body: Powder Coated Aluminum Lens: Polycarbonate Photometric Information CRI: 75 CCT: 5,650K (cool white) IES Files: Available upon request All values typical unless otherwise state All lumen values are typical (tolerance +/- 10%) Temperature Ratings Ambient Temperature Range T4A Temperature Code Ambient Temperature Range T5 Temperature Code -20°F to +149°F (-20°C to +65°C) -20°F to +113°F (-20°C to +45°C) Mounting Options In-line Conduit Mount 4 Overhead Conduit Mount www.dialight.com LSXW4 Application The first of its kind, the Dialight SafeSite® LED linear luminaire was designed specifically to replace HID and fluorescent lighting fixtures in industrial and hazardous location applications. The SafeSite LED Linear fixture’s rugged solid state design makes it highly resistant to shock and vibration , while it’s superior design allows for increased mounting versatility and ease of installation. Mechanical Information SafeSite® LED Linear Fixture Class I, Div. 1 47.46 (1205,4) Fixture Weight: 4’ - 26.0 lbs (11.79 kg) 2’ - 17.5 lbs (7.94 kg)’ Shipping Weight: 4’ - 28.0 lbs (12.70 kg) 2’ - 19.5 lbs (8.85 kg) Mounting: (1) Threaded 3/4” NPT Side (2) Threaded 3/4” NPT Ends Electrical specifications: 4.25 (108) 25.56 (649,1) 6.98 (177,4) Operating Voltage: 100 - 277V AC 50/60Hz or 347 - 480V AC 50/60Hz Power Consumption: See ordering information Operating Temp: -40°F to +149°F (-40°C to +65°C) Harmonics: IEC 61000-3-2 Noise Requirements/ EMC: Dimensions in Inches [mm] Certifications • • • • • • • • Class I, Div 1 Groups C, D UL 844 UL1598 CSA 22.2 No.137 UL 8750 ABS Design Assessed: # 12-HS942957-PDA IP 66 NEMA 4X FCC Title 47, Subpart B, Section 15, class A device. RF Immunity; 10V/m, 80MHz-1GHz Surge Protection EN 61000-4-5 4 kV line to line 4 kV line to ground THD: < 20% Power Factor: > 0.9 Construction Body: Powder Coated Aluminum Lens: Glass Photometric Information Light Distribution CRI: 75 CCT: 5,000K Cool White (100-277V AC) 5,650K Cool White (347-480V AC) IES Files: Available upon request All values typical unless otherwise state All lumen values are typical (tolerance +/- 10%) Temperature Ratings LSC3C4M3GEX (4ft) Ambient Temperature Range T4a Temperature Code LSC3C4D3GEX (2ft) Ambient Temperature Range T5 Temperature Code -40°F to +149°F (-40°C to +65°C) -40°F to +149°F (-40°C to +65°C) Mounting Options Conduit Top Mount Conduit Side Mount www.dialight.com LSXW5 5 SafeSite® LED Linear Fixture Class I Div. 2 Ordering Information Initial Fixture Lumens2,3,4 Watt Lumens Per Watt Clear 3,500 33 106 Clear 7,000 66 106 100 - 277V AC Diffused 3,300 33 100 100 - 277V AC Diffused 6,600 66 100 Top Conduit 100 - 277V AC Clear 3,500 33 106 4’ Top Conduit 100 - 277V AC Clear 7,000 66 106 2’ Top Conduit 100 - 277V AC Diffused 3,300 33 100 4’ Top Conduit 100 - 277V AC Diffused 6,600 66 100 Lens6 Class I, Div 2 Length Type5 Voltage LPD3C4D2P 2’ Low Profile 100 - 277V AC LPD3C4M2P 4’ Low Profile 100 - 277V AC LPD3C4B2D 2’ Low Profile LPD3C4H2D 4’ Low Profile LTD3C4D2P 2’ LTD3C4M2P LTD3C4B2D LTD3C4H2D Part Number1 Battery Backup LSD3C4MEP 4’ Sustained 100 - 277V AC Clear 7,000 85 85 LSD3C4MNP 4’ Maintained 100 - 277V AC Clear 7,000 85 85 Notes: 1 Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSD3C4MEP becomes LSD3N4MEP 2 450 Lumens in Battery Backup mode 3 Expect a 10% reduction in Lumens for 80 CRI minimum fixtures 4 All lumen values are typical (tolerance +/- 10%) 5 See application note on page 3 regarding “sustained” and “maintained” battery modes For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC Class II Ordering Information 1 Part Number1 Length Type CIID1 CIID2 CIIID1 CIIID2 Voltage Lens Initial Fixture Lumens Watt Lumens Per Watt Class II LPF3C4D2P 2' Low Profile E/F/G F/G • • 100 - 277V AC Clear 3,500 33 106 LPF3C4M2P 4' Low Profile E/F/G F/G • • 100 - 277V AC Clear 7,000 66 106 LPF3C4B2D 2' Low Profile E/F/G F/G • • 100 - 277V AC Diffused 3,300 33 100 LPF3C4H2D 4' Low Profile E/F/G F/G • • 100 - 277V AC Diffused 6,600 66 100 LTF3C4D2P 2' Top Conduit E/F/G F/G • • 100 - 277V AC Clear 3,500 33 106 LTF3C4M2P 4' Top Conduit E/F/G F/G • • 100 - 277V AC Clear 7,000 66 106 LTF3C4B2D 2' Top Conduit E/F/G F/G • • 100 - 277V AC Diffused 3,300 33 100 LTF3C4H2D 4' Top Conduit E/F/G F/G • • 100 - 277V AC Diffused 6,600 66 100 Battery Backup LSF3C4MEP 4’ Sustained E/F/G F/G • • 100 - 277V AC Clear 7,000 85 85 LSF3C4MNP 4’ Maintained E/F/G F/G • • 100 - 277V AC Clear 7,000 85 85 Notes: 1 Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LTF3C4D2P becomes LTF3N4D2P For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC Class I Div. 1 Ordering Information Part Number1 Length Voltage Lens Initial Fixture Lumens Watt Lumens Per Watt LSC3C4M3GEX 4’ 100 - 277V AC Clear 7,000 66 106 LSC3C5M3GEX 4’ 347 - 480V AC Clear 7,250 78 93 LSC3C4D3GEX 2’ 100 - 277V AC Clear 3,500 33 106 LSC3C5D3GEX 2’ 347 - 480V AC Clear 3,600 39 92 Class I, Div 1 Notes: 1 Part numbers listed in the above table are cool white. For neutral white models replace the 5th character with N. Ex. LSC3C4D3GEX becomes LSC3N4D3GEX For Dialight’s complete list of DLC qualified products, please click this link: www.dialight.com/DLC 6 www.dialight.com SafeSite® LED Linear Fixture - Options and Accessories Low Profile Models - Class I, Div. 2 / Class II Description Material Part Number Kit Includes Class I, Div. 2 / Class II - Low Profile Models LPXW4 316 Stainless Steel Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware LPXW4LP 316 Stainless Steel Low profile mounting bracket Can be angled at 0° and 15° Mounting bracket Mounting hardware LTXENDCAPKIT 304 Stainless Steel Chain mount and secondary retention bracket 2 Brackets Mounting hardware LTXSAFEKIT 304 Stainless Steel Safety Cable Kit for secondary retention 2 brackets 2 53” Safety cables Mounting hardware Top Conduit Mount Models - Class I, Div. 2 / Class II Part Number Description Material Kit Includes Class I, Div. 2 / Class II - Standard Models LTXW4 6061 Aluminum Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware LTXW4LP 5052 Aluminum Low profile mounting bracket Can be angled at 0° and 15° Mounting bracket Mounting hardware LTXENDCAPKIT 304 Stainless Steel Chain mount and secondary retention bracket 2 Brackets Mounting hardware LTXSAFEKIT 304 Stainless Steel Safety Cable Kit for secondary retention 2 brackets 2 53” Safety cables Mounting hardware LTXLSXW4 6061 Aluminum Retrofit bracket adapter (used to connect LTM model fixtures to an existing LSXW4 bracket) 2 Bracket adapters Mounting hardware www.dialight.com 7 SafeSite® LED Linear Fixture - Options and Accessories Battery Back up Models - Class I, Div. 2 / Class II Part Number Material Description Kit Includes Battery Back up Models LSXW4 6061 Aluminum Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware LSXENDCAPKIT 304 Stainless Steel Chain mount brackets 2 Mounting brackets Mounting hardware HZXSAFEKIT 316 Stainless Steel Safety Cable Kit 2 Eyelets 2 53” Safety cables Mounting hardware Standard Models - Class I, Div 1 Part Number Material Description Kit Includes Class I, Div 1 Models LSXW5 6061 Aluminum Mounting bracket Can be angled at 0°, 30°, 45°, 60° & 90° Mounting bracket Mounting hardware HZXSAFEKIT 316 Stainless Steel Safety Cable Kit 2 Eyelets 2 53” Safety cables Mounting hardware Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/MDTFSLINX001.pdf. Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT. www.dialight.com MDTFSLINX001_K 8