DuroSite LED Area Light Installation Manual

INSTALLATION AND MAINTENANCE MANUAL
SAFESITE /DUROSITE HZx/ STW SERIES WITH MOUNTING ACCESSORIES
Document No: 9100-127-2297-99 Rev B
JULY 2015


FOR USE WITH MODEL NUMBERS:
HZXXXXXW01
HZXXXXXW45
HZXXXXXS45
STWXXXXW01
STWXXXXW45
STWXXXXS45
These instructions contain important safety information, read and follow them
carefully. Dialight will not accept any responsibility for injury, damage or loss which
may occur due to incorrect installation, operation or maintenance
1: Introduction
This HZx/STW Series light is designed for illumination of hazardous and non-hazardous locations.
It uses the latest in solid state lighting technology for long life, low maintenance, and high
efficiency.
The unique optical design focuses light downward to where it is needed, giving improved efficiency
over a conventional HID luminaire.
An internal power-factor-corrected supply allows it to be used from any nominal 100V-277V,
50/60Hz single phase AC supply without any variation in light output.
When using 208V (two 120V phases), connect the black wire to one phase and the white wire to
the other phase. Since the light fixture does not have an internal fuse in-line with the white wire
(normally the Neutral) a fuse may be connected in series with it if required.
Model HZx/STW is suitable for use in the following locations:

HAZARDOUS LOCATIONS:

NON-HAZARDOUS LOCATIONS:
CLASS I DIV 2 GROUPS A, B, C, D
Ta - Ambient Temp: -40 TO +65°C
Temp Rating: T5 (100°C) when Ta <= 45
Temp Rating: T4 (135°C) when Ta <=65
SUITABLE FOR WET LOCATIONS
UL1598/1598A
Note: Save these instructions for future reference.
Document No: 9100-127-2297-99 Rev B
2: Installation
Hazardous Locations Warning:
To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected,
and maintained by a qualified electrician only, in accordance with all applicable electrical codes.
Hazardous Locations Warning:
To avoid electric shock:

Be certain electrical power is OFF before and during installation and maintenance.

Luminaire must be connected to a wiring system with an equipment-grounding conductor.
Hazardous Locations Warning:
To avoid explosion:
 Make sure the supply voltage is within the luminaries’ voltage rating.
 Ensure the marked T Rating is less than the ignition temperature of the Hazardous Atmosphere.
 Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
 Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
 WARNING - EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR
SUITABILITY FOR CLASS I, DIVISION 2.
 AVERTISSEMENT - RISQUE D'EXPLOSION - LA SUBSTITUTIOND E COMPOSANTSP EUTR
ENDRE CE MATERIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I,
DIVISION 2.
Hazardous Locations Warning:
To Avoid Explosion (Continued) :

EXPLOSION HAZARD- DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN
SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS
 AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DECONNECTER L'EQUIPEMENT,
COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON
DANGEREUX
Hazardous Locations Warning:





DO NOT let power cord touch hot surfaces
DO NOT mount near gas or electric heaters
Equipment should be mounted in locations and at heights where it will not be subjected to
tampering by unauthorized personnel.
The use of accessory equipment not recommend by the manufacture may cause an unsafe
condition
DO NOT use this equipment for other than intended use
Page 2 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
Warning:




The technical data indicated on the Luminaire are to be observed.
Changes to the design and modifications of the Luminaire are not permitted
Only genuine Dialight replacement parts are to be used when unforeseen maintenance is
required
Must install using NEMA 4x rated components to maintain rating.
Warning: POLYCARBONATE LENS SUSCEPTIBLE TO CHEMICAL ATTACK AVOID USE
WITH:
o Strong Bases
 Ammonium Hydroxide
 Sodium Hydroxide
 Potassium Hydroxide
o Halogenated solvents
 Methylene Chloride
 Chloroform
 Carbon Tetra Chloride
o The Ketones
 Acetone
 Acetonitrile
 Ethyl Acetate
 Methyl Ethyl Ketone – (MEK)
o Also Avoid Use With
 Benzene
 Benzyl Alcohol
 Lacquer Thinner
 Mineral Spirits
 Jet Fuel
AVOID USE WITH:





Dimethyl Sulfoxide
Diethyl Ether
Carbon Disulfide
Eylene
Urea
***NOTE: This list is not comprehensive and is not meant to be so. It is up to the end user to test
and verify the product is suitable for use in a given location***
For supply connections use wire rated for at least 90°C
Recommended mounting height: 8 feet to 24 feet (2.4 m to 7.3 m)
NOTE:



For maximum long term reliability and light output, the light must be installed in free air.
The HZx/ STW Series fixtures are design incorporates an over-temperature control circuit that
reduces input power should internal temperatures reach a maximum level. As a result, light output
may be reduced.
Necessary precautions must be taken by the installer to prevent the moisture and all other
contaminants from entering a mount through the cable, pole or conduit entries.
Page 3 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
Wall Mount Steps:
NOTE: Wall Mount Fixtures are to be mounted to vertical surfaces structurally adequate to support the
fixture in a safe manner. All 5 conduit connection ports are ¾-14 NPT. The 0° Wall Mount shown in all figures
below. All steps also apply to the 45° Wall Mount
1.
Assure electrical power is OFF.
2.
Mark and drill 4 holes of the appropriate size and depth to accept 5/16 (or M8) diameter threaded
fasteners. (not supplied) Spacing per Figure 1
Figure 1: Required Wall Hole Pattern
3.
Separate the Wall Mount from the fixture assembly by loosening the single ¼-20 nut and swing the
bolt free (do not remove the nut.) Rotate the Wall mount until it freely separates from the fixture. See
Figure 2 and
Figure 3
¼-20 Nut
Figure 2: Loosen and rotate ¼-20 nut
Figure 3: Separate Wall Mount from Fixture
Page 4 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
Firmly secure the Wall Mount to the wall surface using four 5/16 or M8 diameter fasteners with the
appropriate anchoring system. Fastener hardware not provided. See Figure 4.
NOTE: If connecting to the rear ¾-14 NPT port (port facing the wall) use a cable gland properly
rated for the application to seal the Wall Mount fixture. Cable gland not supplied.
4.
Figure 4: Anchor Wall Mount to Wall
5.
Attach ¾-14 NPT threaded conduit into the required ports and bring the electrical wiring into the Wall
Mount. All conduit connections and unused ¾-14 NPT ports must be environmentally sealed. Unused ports are closed using the NPT threaded plugs provided or equivalent.
NOTE: The Wall Mount is supplied with 5 conduit entries top, bottom, left, right and rear. The
top conduit entry port is open (no NPT plug) If this port not used assure it is environmental
sealed using a proper ¾-14 NPT plug.
6.
Make all wire connections per local electric code. See Figure 5
o For single phase (120 / 277 VAC):

Green wire connects to Safety Ground. (use pigtails supplied)

White wire connects to Neutral

Black wire connects to HOT
Figure 5: Wiring Diagram
NOTE: Inspect and assure connections are made properly.
7.
Rotate fixture shut, Swing ¼-20 bolt into place and tighten nut to seal assembly shut. Torque ¼-20
nut to 4 ft-lbs [5.4 N-m]. See Figure 6
When closing the assembly assure that the red colored oring is properly
seated and there is no wires or object interfering with the oring seal or
sealing surfaces.
Page 5 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
Torque ¼-20 Nut to
4 ft-lbs [5.4 N-m]
Figure 6: Close and Torque ¼-20 nut
8.
Restore power and verify operation.
Prior to restoring power assure that all unused ¾”-14 ports are properly
plugged
45° Stanchion Mount Steps:
NOTE: The 45° Stanchion Mount fixture is intended to be mounted to 2” x 11-1/2 NPT threaded
vertical pole sealed to the proper IPXX rating for the application. Use the appropriate NPT threaded
reducing bushing to adapter a stanchion Mount fixture to a 1.5” x 11-1/2 NPT threaded pole.
1.
Assure electrical power is OFF.
Page 6 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
2.
Loosen and back off ¼-20 nut. Do not remove nut. Rotate bolt and separate the Stanchion Mount
from the Light Fixture assembly. See Figures 7 and 8
¼-20 Nut
Light
Fixture
Stanchion
Mount
Figure 7: Loosen and rotate bolt clear
3.
Figure 8: Separate Stanchion Mount from Light Fixture
Back off 5/16-18 screw provided such that it will not interfere with the attachment operation. Firmly
thread the Stanchion Mount to the 2X11.5 NPT threaded pole. Properly engage the threads and turn
the Stanchion Mount by hand until tight. Continue tightening using a wrench until the proper
orientation is achieved. Torque the 5/16-18 screw to 10 ft-lbs [14 N-m]. If attaching to a 1.5x11.5 NPT
threaded pole attach a reducer bushing to the pole first. See Figure 9 and
Figure 10
5/16-18
Screw
Figure 9: 2” X 11.5 NPT THREAED POLE
Figure 10: 1.5” X 11.5 NPT REDUCER BUSHING
Page 7 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
4.
Hang the Light Fixture on the Stanchion Mount and prepare for electrical wiring.
Figure 11: Hang Light Fixture onto Stanchion Mount
5.
Make all wire connections per local electric code. See Figure 5
o For single phase (120 / 277 VAC):

Green wire connects to Safety Ground. (use pigtails supplied)

White wire connects to Neutral

Black wire connects to HOT
Figure 12: Wiring Diagram
SINGLE PHASE 120/277 VAC WIRE COLOR CODE - IEC (US)
BROWN (BLACK) = LIVE
BLUE (WHITE) = NEUTRAL
GREEN-YELLOW (GREEN) = GROUND
NOTE: Inspect and assure connections are made properly.
When closing the assembly assure that the red colored oring is properly
seated and there is no wires or object interfering with the oring seal or sealing
surfaces.
6.
Rotate fixture shut, assure no object is interfering with the oring seal or sealing surfaces. Swing ¼-20
bolt into place and tighten nut to seal assembly shut. Torque ¼-20 nut to 4 ft-lbs [5.4 N-m]. Torque
the 5/16-18 screw to 10 ft-lbs [14 N-m]. See Figure 13
Page 8 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
Figure 13
7.
Restore power and verify operation.
3: Maintenance

To avoid personal injury, disconnect power to the light and allow the unit to cool down
before performing maintenance.
Warning: No user serviceable parts inside of fixture. Risk of electric shock. Removal of
the lens will void the warranty.
1) Perform visual, mechanical and electrical inspections on a regular basis. We recommend
routine checks to be made on a yearly basis. Frequency of use and environment should
determine this. It is recommended to follow an Electrical Preventive Maintenance Program
as described in NFPA 70B: Recommended Practice for Electrical Equipment.
2) The lens should be cleaned periodically as needed to ensure continued photometric
performance. Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use
mild soap or a liquid cleaner.
3) Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or
contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.
4) Do not operate if the lens is cracked or damaged.
5) During the routine check all fasteners used to mount the fixture should be examined for
condition and proper torque value.
Page 9 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
COOLING FINS
POLYCARBONATE
LENS
4: Specifications
Nominal AC Supply Voltage
100-277VAC, 50-60Hz, single phase
Power consumption
70W
55W
43W
21W
Operating temperature range
-40°F to +149°F [-40°C to +65°C]
T4 @ 149°F [65°C]
Power factor
>0.90
ATHD
<20%
Dimensions
0° Wall Mount
45° Wall Mount
45° Stanchion Mount
See Figure 14
See Figure 15
See Figure 16
nominal (XXX8, XXX9 SRS)
nominal [XXX4, XXX5 SRS)
nominal (XXX2, XXX3 SRS)
nominal (XXX0, XXX1 SRS)
Weight
0° Wall Mount
45° Wall Mount
45° Stanchion Mount
15.0 lbs [6.8 kgf]
14.2 lbs [6.4 kgf]
14.8 lbs [6.7 kgf]
Connections - Wall Mount
45° Stanchion
¾”-14 NPT ports (five total)
2”-11.5 NPT port (1.5”-11.5 NPT with reducer)
Intertek Certified to
ANSI/UL-844 and CAN/CSA C22.2 No. 137
Page 10 of 11
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
Document No: 9100-127-2297-99 Rev B
Figure 14: 0° Wall Mount
Figure 15: 45° Wall Mount
Figure 16: 45° Stanchion Mount
DIMENSIONS ARE FOR REFERENCE ONLY.
All statements, technical information and recommendations contained herein are based on information and
tests we believe to be reliable. The accuracy or completeness thereof is not guaranteed. In accordance with
Dialight Corporation “Terms and Conditions of Sale”, and since conditions of use are outside our control, the
purchaser should determine the suitability of the product for his intended use and assumes all risk and liability
whatsoever in connection therewith.
REV.
B
ECO No. DRN
27110
SCR
CHK
VJD
APP
SB
QA
SV
CM
JN
DATE
8/3/15
Page 11 of 11