INSTALLATION AND MAINTENANCE MANUAL SAFESITE /DUROSITE HZx/ STW SERIES WITH MOUNTING ACCESSORIES Document No: 9100-127-2297-99 Rev B JULY 2015 FOR USE WITH MODEL NUMBERS: HZXXXXXW01 HZXXXXXW45 HZXXXXXS45 STWXXXXW01 STWXXXXW45 STWXXXXS45 These instructions contain important safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect installation, operation or maintenance 1: Introduction This HZx/STW Series light is designed for illumination of hazardous and non-hazardous locations. It uses the latest in solid state lighting technology for long life, low maintenance, and high efficiency. The unique optical design focuses light downward to where it is needed, giving improved efficiency over a conventional HID luminaire. An internal power-factor-corrected supply allows it to be used from any nominal 100V-277V, 50/60Hz single phase AC supply without any variation in light output. When using 208V (two 120V phases), connect the black wire to one phase and the white wire to the other phase. Since the light fixture does not have an internal fuse in-line with the white wire (normally the Neutral) a fuse may be connected in series with it if required. Model HZx/STW is suitable for use in the following locations: HAZARDOUS LOCATIONS: NON-HAZARDOUS LOCATIONS: CLASS I DIV 2 GROUPS A, B, C, D Ta - Ambient Temp: -40 TO +65°C Temp Rating: T5 (100°C) when Ta <= 45 Temp Rating: T4 (135°C) when Ta <=65 SUITABLE FOR WET LOCATIONS UL1598/1598A Note: Save these instructions for future reference. Document No: 9100-127-2297-99 Rev B 2: Installation Hazardous Locations Warning: To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. Hazardous Locations Warning: To avoid electric shock: Be certain electrical power is OFF before and during installation and maintenance. Luminaire must be connected to a wiring system with an equipment-grounding conductor. Hazardous Locations Warning: To avoid explosion: Make sure the supply voltage is within the luminaries’ voltage rating. Ensure the marked T Rating is less than the ignition temperature of the Hazardous Atmosphere. Do not operate in ambient temperatures above those indicated on the luminaire nameplate. Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. WARNING - EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. AVERTISSEMENT - RISQUE D'EXPLOSION - LA SUBSTITUTIOND E COMPOSANTSP EUTR ENDRE CE MATERIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I, DIVISION 2. Hazardous Locations Warning: To Avoid Explosion (Continued) : EXPLOSION HAZARD- DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DECONNECTER L'EQUIPEMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX Hazardous Locations Warning: DO NOT let power cord touch hot surfaces DO NOT mount near gas or electric heaters Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommend by the manufacture may cause an unsafe condition DO NOT use this equipment for other than intended use Page 2 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B Warning: The technical data indicated on the Luminaire are to be observed. Changes to the design and modifications of the Luminaire are not permitted Only genuine Dialight replacement parts are to be used when unforeseen maintenance is required Must install using NEMA 4x rated components to maintain rating. Warning: POLYCARBONATE LENS SUSCEPTIBLE TO CHEMICAL ATTACK AVOID USE WITH: o Strong Bases Ammonium Hydroxide Sodium Hydroxide Potassium Hydroxide o Halogenated solvents Methylene Chloride Chloroform Carbon Tetra Chloride o The Ketones Acetone Acetonitrile Ethyl Acetate Methyl Ethyl Ketone – (MEK) o Also Avoid Use With Benzene Benzyl Alcohol Lacquer Thinner Mineral Spirits Jet Fuel AVOID USE WITH: Dimethyl Sulfoxide Diethyl Ether Carbon Disulfide Eylene Urea ***NOTE: This list is not comprehensive and is not meant to be so. It is up to the end user to test and verify the product is suitable for use in a given location*** For supply connections use wire rated for at least 90°C Recommended mounting height: 8 feet to 24 feet (2.4 m to 7.3 m) NOTE: For maximum long term reliability and light output, the light must be installed in free air. The HZx/ STW Series fixtures are design incorporates an over-temperature control circuit that reduces input power should internal temperatures reach a maximum level. As a result, light output may be reduced. Necessary precautions must be taken by the installer to prevent the moisture and all other contaminants from entering a mount through the cable, pole or conduit entries. Page 3 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B Wall Mount Steps: NOTE: Wall Mount Fixtures are to be mounted to vertical surfaces structurally adequate to support the fixture in a safe manner. All 5 conduit connection ports are ¾-14 NPT. The 0° Wall Mount shown in all figures below. All steps also apply to the 45° Wall Mount 1. Assure electrical power is OFF. 2. Mark and drill 4 holes of the appropriate size and depth to accept 5/16 (or M8) diameter threaded fasteners. (not supplied) Spacing per Figure 1 Figure 1: Required Wall Hole Pattern 3. Separate the Wall Mount from the fixture assembly by loosening the single ¼-20 nut and swing the bolt free (do not remove the nut.) Rotate the Wall mount until it freely separates from the fixture. See Figure 2 and Figure 3 ¼-20 Nut Figure 2: Loosen and rotate ¼-20 nut Figure 3: Separate Wall Mount from Fixture Page 4 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B Firmly secure the Wall Mount to the wall surface using four 5/16 or M8 diameter fasteners with the appropriate anchoring system. Fastener hardware not provided. See Figure 4. NOTE: If connecting to the rear ¾-14 NPT port (port facing the wall) use a cable gland properly rated for the application to seal the Wall Mount fixture. Cable gland not supplied. 4. Figure 4: Anchor Wall Mount to Wall 5. Attach ¾-14 NPT threaded conduit into the required ports and bring the electrical wiring into the Wall Mount. All conduit connections and unused ¾-14 NPT ports must be environmentally sealed. Unused ports are closed using the NPT threaded plugs provided or equivalent. NOTE: The Wall Mount is supplied with 5 conduit entries top, bottom, left, right and rear. The top conduit entry port is open (no NPT plug) If this port not used assure it is environmental sealed using a proper ¾-14 NPT plug. 6. Make all wire connections per local electric code. See Figure 5 o For single phase (120 / 277 VAC): Green wire connects to Safety Ground. (use pigtails supplied) White wire connects to Neutral Black wire connects to HOT Figure 5: Wiring Diagram NOTE: Inspect and assure connections are made properly. 7. Rotate fixture shut, Swing ¼-20 bolt into place and tighten nut to seal assembly shut. Torque ¼-20 nut to 4 ft-lbs [5.4 N-m]. See Figure 6 When closing the assembly assure that the red colored oring is properly seated and there is no wires or object interfering with the oring seal or sealing surfaces. Page 5 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B Torque ¼-20 Nut to 4 ft-lbs [5.4 N-m] Figure 6: Close and Torque ¼-20 nut 8. Restore power and verify operation. Prior to restoring power assure that all unused ¾”-14 ports are properly plugged 45° Stanchion Mount Steps: NOTE: The 45° Stanchion Mount fixture is intended to be mounted to 2” x 11-1/2 NPT threaded vertical pole sealed to the proper IPXX rating for the application. Use the appropriate NPT threaded reducing bushing to adapter a stanchion Mount fixture to a 1.5” x 11-1/2 NPT threaded pole. 1. Assure electrical power is OFF. Page 6 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B 2. Loosen and back off ¼-20 nut. Do not remove nut. Rotate bolt and separate the Stanchion Mount from the Light Fixture assembly. See Figures 7 and 8 ¼-20 Nut Light Fixture Stanchion Mount Figure 7: Loosen and rotate bolt clear 3. Figure 8: Separate Stanchion Mount from Light Fixture Back off 5/16-18 screw provided such that it will not interfere with the attachment operation. Firmly thread the Stanchion Mount to the 2X11.5 NPT threaded pole. Properly engage the threads and turn the Stanchion Mount by hand until tight. Continue tightening using a wrench until the proper orientation is achieved. Torque the 5/16-18 screw to 10 ft-lbs [14 N-m]. If attaching to a 1.5x11.5 NPT threaded pole attach a reducer bushing to the pole first. See Figure 9 and Figure 10 5/16-18 Screw Figure 9: 2” X 11.5 NPT THREAED POLE Figure 10: 1.5” X 11.5 NPT REDUCER BUSHING Page 7 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B 4. Hang the Light Fixture on the Stanchion Mount and prepare for electrical wiring. Figure 11: Hang Light Fixture onto Stanchion Mount 5. Make all wire connections per local electric code. See Figure 5 o For single phase (120 / 277 VAC): Green wire connects to Safety Ground. (use pigtails supplied) White wire connects to Neutral Black wire connects to HOT Figure 12: Wiring Diagram SINGLE PHASE 120/277 VAC WIRE COLOR CODE - IEC (US) BROWN (BLACK) = LIVE BLUE (WHITE) = NEUTRAL GREEN-YELLOW (GREEN) = GROUND NOTE: Inspect and assure connections are made properly. When closing the assembly assure that the red colored oring is properly seated and there is no wires or object interfering with the oring seal or sealing surfaces. 6. Rotate fixture shut, assure no object is interfering with the oring seal or sealing surfaces. Swing ¼-20 bolt into place and tighten nut to seal assembly shut. Torque ¼-20 nut to 4 ft-lbs [5.4 N-m]. Torque the 5/16-18 screw to 10 ft-lbs [14 N-m]. See Figure 13 Page 8 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B Figure 13 7. Restore power and verify operation. 3: Maintenance To avoid personal injury, disconnect power to the light and allow the unit to cool down before performing maintenance. Warning: No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void the warranty. 1) Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine checks to be made on a yearly basis. Frequency of use and environment should determine this. It is recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B: Recommended Practice for Electrical Equipment. 2) The lens should be cleaned periodically as needed to ensure continued photometric performance. Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid cleaner. 3) Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed. 4) Do not operate if the lens is cracked or damaged. 5) During the routine check all fasteners used to mount the fixture should be examined for condition and proper torque value. Page 9 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B COOLING FINS POLYCARBONATE LENS 4: Specifications Nominal AC Supply Voltage 100-277VAC, 50-60Hz, single phase Power consumption 70W 55W 43W 21W Operating temperature range -40°F to +149°F [-40°C to +65°C] T4 @ 149°F [65°C] Power factor >0.90 ATHD <20% Dimensions 0° Wall Mount 45° Wall Mount 45° Stanchion Mount See Figure 14 See Figure 15 See Figure 16 nominal (XXX8, XXX9 SRS) nominal [XXX4, XXX5 SRS) nominal (XXX2, XXX3 SRS) nominal (XXX0, XXX1 SRS) Weight 0° Wall Mount 45° Wall Mount 45° Stanchion Mount 15.0 lbs [6.8 kgf] 14.2 lbs [6.4 kgf] 14.8 lbs [6.7 kgf] Connections - Wall Mount 45° Stanchion ¾”-14 NPT ports (five total) 2”-11.5 NPT port (1.5”-11.5 NPT with reducer) Intertek Certified to ANSI/UL-844 and CAN/CSA C22.2 No. 137 Page 10 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com Document No: 9100-127-2297-99 Rev B Figure 14: 0° Wall Mount Figure 15: 45° Wall Mount Figure 16: 45° Stanchion Mount DIMENSIONS ARE FOR REFERENCE ONLY. All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof is not guaranteed. In accordance with Dialight Corporation “Terms and Conditions of Sale”, and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith. REV. B ECO No. DRN 27110 SCR CHK VJD APP SB QA SV CM JN DATE 8/3/15 Page 11 of 11 1501 Route 34 South, Farmingdale, NJ 07727 Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com