Powered by XTV121200 12V 120Ah XTV 12950 is a general battery up to 12 years expected life in standby service or more than 400 cycles at 100% discharge in cycle service . XTV!has a wider operating temperature range, which makes them more suitable for the systems in harsh conditions. Specification Cells Per Unit Voltage Per Unit Capacity Weight Maximum Discharge Current Internal Resistance Operating Temperature Range 6 12 120 Ah @ 10hr-rate to 1.80 V per cell @25 (77 ) Approx. 40.6 kg(89.51 lbs) 800A(5sec) Approx. 6.5m Discharge: -20 ~50 (-4 ~122 ) (-4 ~122 ) Charge: -20 ~50 (5 ~104 ) Storage: -15 ~40 3 (77 5 ) Nominal Operating Temperature Range 25 13.5 to 13.8 VDC/unit Average at 25 (77 ) Float Charging Voltage Recommended Maximum Charging 36A Current Limit 14.4 to 15.0 VDC/unit Average at 25 (77 ) Equalization and Cycle Service Self Discharge CSB Batteries can be stored for more than 6 months at 25 (77 ). Please charge batteries before using. For higher temperatures the time interval will be shorter. Terminal I2-Thread lead alloy recessed terminal to accept M6 bolt PP (UL 94-V0/File E50955)*Flammability resistance Container Material of (UL 94-HB/File E216959) can be available upon request. Dimensions : Unit: mm (inch) Overall Height (H) 275.7±2.5 (10.85±0.08) Container height (h) 273.2±2.5 (10.75±0.08) Length (L) 343±2.5 (13.50±0.1) Constant Current Discharge Characteristics F.V/Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5MIN 449 396 369 328 298 246 10MIN 310 290 277 255 231 206 15MIN 237 226 220 210 193 169 30MIN 144 141 138 133 125 115 1HR 85.9 84.1 83.2 80.9 77.8 72.6 2HR 51.1 49.8 49.5 48.0 46.0 43.0 3HR 35.2 34.8 34.3 33.4 32.8 31.0 5MIN 4199 3883 3751 3517 3098 2637 10MIN 3135 2980 2892 2713 2519 2240 15MIN 2523 2448 2420 2269 2079 1832 30MIN 1561 1544 1529 1481 1411 1311 1HR 953 940 937 918 885 834 2HR 568 560 555 543 521 494 3HR 402 398 395 386 377 359 Unit:A (25 4HR 26.9 26.8 26.5 26.0 25.6 24.2 Constant Power Discharge Characteristics F.V/Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V CSB-manufactured batteries are ULrecognized components under UL924 and UL1989. CSB is also certified by ISO 9001 and ISO 14001. 5HR 22.2 22.0 21.9 21.6 21.2 20.1 Unit:W (25 4HR 315 310 308 303 296 281 5HR 259 257 256 252 246 234 Width (W) 170±2 (6.69±0.08) ,77 8HR 14.8 14.7 14.6 14.3 14.1 13.6 ,77 8HR 174 172 171 170 167 161 ) 10HR 12.3 12.2 12.1 11.9 11.8 11.2 20HR 6.43 6.40 6.37 6.30 6.18 5.94 ) 10HR 144 143 142 141 140 134 20HR 75.3 74.5 74.1 73.8 72.6 70.5 RA: 0808 12V 120Ah XTV 121200 140 0.20 2.60 120 0.17 2.40 100 0.14 2.20 80 0.11 2.00 60 0.08 1.80 40 0.05 1.60 20 0.02 1.40 )Ratio 13.65V 0 140 0.20 2.60 120 0.17 2.40 100 0.14 2.20 80 0.11 2.00 60 0.08 1.80 40 0.05 1.60 20 0.02 1.40 0 Application (2.275V/Cell) 4 8 12 16 )Ratio 4 8 12 16 Charge Voltage(V/Cell) Set Point Cycle Use 2.45 2.40~2.50 Standby 25 (77 ) 2.275 2.25~2.30 E-mail: [email protected] 24 68 Temperature 25 (77 ) Tel: +886-2-2555-5600 Fax: +886-2-2555-3300 20 Allowable Range 20 24 Max.Charge Current Final Discharge Voltage V/Cell 1.75 1.70 1.60 1.30 0.3C Discharge Current(A) 0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C EUROPE OFFICE Tel: +31(0)180 418 140 Fax: +31(0)180 418 327 E-mail: [email protected] Tel: +86-755-8831-6488/6396/16356 Fax: +86-755-8831-6548 E-mail: [email protected]