HM75 - BI Technologies

HM75
Electrical / Environmental
•
•
•
•
•
Operating Temperature Range
Ambient Temperature, Maximum
Insulation System
Temperature Rise, Maximum
Operating Frequency
-40°C to +125°C
85°C
Class B, 130°C
40°C
Up to 3MHz
High Current Surface Mount Inductors
S
RomHpliant
Co
Specifications @ 25°C
Rated Inductance
Rated
L w/o DC DCR Current
Part
LDC
LO (1)
Max. IRMS (2)
Number
µH Typ. µH ± 20% mW
Amps
HM75-10R33LF
0.33
0.33
4.0
7.0
HM75-10R47LF 0.47
0.47
7.9
6.0
HM75-101R0LF
1.0
1.0
12.5
4.4
HM75-101R5LF
1.5
1.6
14.5
4.2
HM75-102R2LF
2.2
2.26
24.1
3.1
HM75-103R3LF
3.3
3.45
31.8
2.9
HM75-104R7LF
4.7
4.85
54.7
2.2
HM75-106R8LF
6.8
6.9
57.1
1.7
HM75-10100LF
10
10.4
81.3
1.5
HM75-10150LF
15
15.3
124
1.2
HM75-10220LF
22
23
183
1.0
HM75-10330LF
33
33.6
265
0.82
HM75-10470LF
47
48.5
334
0.72
HM75-20R33LF
0.33
0.33
2.0
16
HM75-20R68LF
0.68
0.80
3.5
12
HM75-201R0LF
1.0
1.1
4.6
10
HM75-201R5LF
1.5
1.5
6.1
9
HM75-202R2LF
2.2
2.3
7.8
7.4
HM75-202R7LF
2.7
2.9
10.0
6.6
HM75-203R3LF
3.3
3.3
11.0
5.9
HM75-204R7LF
4.7
4.8
15.1
4.8
HM75-20100LF
10
10.0
35
3.3
HM75-20150LF
15
15.43
45
3.1
HM75-20220LF
22
22.5
62
2.8
HM75-20330LF
33
33.2
92
2.1
HM75-20470LF
47
48.7
139
1.7
HM75-20680LF
68
68.2
177
1.5
HM75-20101LF
100
103
237
1.2
HM75-30R47LF
0.47
0.45
2.1
16
HM75-301R0LF
1.0
1.34
3.8
12.5
HM75-301R5LF
1.5
1.65
4.9
10
HM75-302R2LF
2.2
2.3
5.1
9.2
HM75-303R3LF
3.3
3.44
10
8.0
HM75-304R7LF
4.7
5.0
11.4
6.5
HM75-306R8LF
6.8
6.9
17.8
5.8
HM75-30100LF
10
11
22.8
4.3
HM75-30150LF
15
16.4
35.0
3.9
ISAT (3)
Amps
10.0
7.7
5.3
4.5
3.5
3.0
2.6
2.2
1.9
1.5
1.2
0.99
0.87
20
13
11
9
7.8
7.0
6.4
5.4
4.3
3.0
2.0
1.7
1.4
1.2
0.95
25.1
15.3
12
10.2
9.3
7.7
6.2
5.2
4.36
Rated Inductance
Rated
L w/o DC DCR Current
Part
LDC
LO (1)
Max. IRMS (2)
Number
µH Typ. µH ± 20% mW
Amps
HM75-30220LF
22
23.9
49.1
3.1
HM75-30330LF
33
33.9
69
2.4
HM75-30470LF
47
51
108.2
1.9
HM75-30680LF
68
69.5
156
1.6
HM75-30101LF
100
101.4
205.5
1.4
HM75-40R47LF
0.47
0.47
1.7
19.2
HM75-401R0LF
1.0
0.92
2.5
17.3
HM75-401R3LF
1.3
1.3
3.5
15
HM75-402R2LF
2.2
2.2
4.7
12
HM75-403R3LF
3.3
3.3
8.4
10
HM75-403R9LF
3.9
3.9
7.5
9
HM75-404R7LF
4.7
5.3
9.5
8.5
HM75-406R0LF
6.0
6.0
13.7
7.5
HM75-407R8LF
7.8
7.8
15.4
7.5
HM75-40100LF
10
10.0
22.0
6.0
HM75-40150LF
15
15.6
29.5
5.5
HM75-40220LF
22
22.6
34
4.5
HM75-40330LF
33
34.5
52
3.7
HM75-40470LF
47
48.0
71
3.1
HM75-40680LF
68
69.2
104
2.4
HM75-40101LF
100
103
156
2.0
HM75-50R78LF
0.78
0.78
2.6
15
HM75-501R0LF
1.0
0.92
3.1
17.3
HM75-501R5LF
1.5
1.52
4.0
15
HM75-502R2LF
2.2
2.27
5.6
12
HM75-503R3LF
3.3
3.2
7.0
11
HM75-503R9LF
3.9
4.0
10
9
HM75-504R7LF
4.7
4.7
9.5
6.5
HM75-507R5LF
7.5
7.5
15
6
HM75-50100LF
10
10
40
3.5
HM75-50150LF
15
15
50
3.0
HM75-50220LF
22
22
66
2.5
HM75-50330LF
33
33
80
2.0
HM75-50470LF
47
47
110
1.6
HM75-50680LF
68
68
170
1.2
HM75-50101LF
100
100
220
1.2
ISAT (3)
Amps
3.7
3.0
2.4
2.0
1.8
51.7
37.3
25
20
17
15
15
12
11
10
9.1
7.6
6.1
5.2
4.3
3.6
30
37.3
28.9
23.7
20.0
15
10.7
9.8
8.0
7.0
5.5
4.0
3.8
3.0
2.5
Notes: (1) Inductance is measured at 100kHz, 100 mVrms, OADC.
(2) RMS current is the approximate current at which inductance will decrease by 10% from its initial value (zero DC)
or the DC current at which ∆T = 40°C, whichever is lower.
(3) Saturation current for approximately 30% roll-off.
www.bitechnologies.com
2009/10 EDITION MAGNETIC COMPONENTS SELECTOR GUIDE
We reserve the right to change specifications without prior notice.
101
Outline Dimensions (Inch/mm)
Case size
A
B
C
D
E
F
10
.350
8.89
.240
6.09
.217
5.5
.249
6.33
.137
3.48
.225
5.72
20
30
.530
13.46
.768
19.5
.395
10.03
.52
13.21
.272
6.90
.283
7.2
.410
10.41
.610
15.5
.135
3.43
.135
3.43
.295
7.49
.283
7.2
40
.865
21.97
.60
15.24
.315
8.0
.690
17.53
.150
3.81
.370
9.40
50
.530
13.46
.395
10.03
.50
12.7
.410
10.41
.135
3.43
.295
7.49
Packaging
Standard: Embossed Tape and Reel
Reel: Diameter:
Capacity: Case size 10
Case size 20
Case size 30
Case size 40
Case size 50
=
=
=
=
=
=
13” (330.2mm)
1,000 Units
550 Units
450 Units
275 Units
250 Units
Ordering Information
HM75 - 20
101
LF
TR
Model Series
Tape & Reel Packing
Case Size:
Lead Free
Inductance Code:
First 2 digits are significant. Last digit denotes
the number of trailing zeros. For values below
10µH, “R“ denotes the decimal point.
102
MAGNETIC COMPONENTS SELECTOR GUIDE 2009/10 EDITION
We reserve the right to change specifications without prior notice.
www.bitechnologies.com