2900 SERIES REED RELAYS 2900 Series Reed Relays Ideally suited to the needs of Automated Test Equipment and RF requirements. The specification tables allow you to select the appropriate relay for your particular application. Slightly larger than the 2200 Series; these relays provide maximum versatility with options such as a Form C with electrostatic or co-axial shielding. If your requirements differ, please consult your local representative or Coto’s Factory. 2900 Series Features u Very small (0.20 in 2), high reliability reed relays u High Insulation Resistance - 1012Ω offered on 2904 u High speed switching compared to electromechanical relays u Hermetically sealed contacts for long life u Epoxy coated steel shell provides magnetic shielding u Optional Electrostatic Shield for reducing capacitive coupling u Optional Coaxial Shield for 50Ω impedance and switching of fast rise time digital pulses u RoHS compliant (except for 2920) DIMENSIONS in Inches (Millimeters) .250 (6.35) .820 (20.82) .280 (7.11) .500 (12.7) .125 (3.18) .700 (17.78) 1 2 3 4 8 7 6 5 .020 (0.51) .100 (2.54) .022 Dia. pins (0.56) Bottom View Ordering Information Part Number Model Number 2904 2911 2920 29XX-XX-XX1 Shielding Options2 0=No Shield 1=Electrostatic Shield 2=Co-axial Shield Coil Voltage 05=5 volts 12=12 volts Coil Options 1=Use for Model #2920 (5 & 12 volt coil) 3=Use for Model #2904 (12 volt coil) and for Model #2911 (5 & 12 volt coil) 4=Use for Model #2904 (5 volt coil) 07082013 tel: (401) 943.2686 | fax: (401) 942.0920 MODEL NUMBER Parameters Test Conditions Units 29042 29112 29202,3 1 Form A 1 Form C 1Form A Hg Wetted COIL SPECS. Nom. Coil Voltage VDC 5 12 5 12 5 12 +/- 10%, 25° C Ω 370 1500 230 1500 75 250 Operate Voltage Must Operate by VDC - Max. 3.8 9.0 3.8 9.0 3.8 9.0 Release Voltage Must Release by VDC - Min. 0.4 1.0 0.4 1.0 0.4 1.0 Max DC/Peak AC Resist. Volts 200 150 500 Coil Resistance CONTACT RATINGS Switching Voltage Switching Current Max DC/Peak AC Resist. Amps 0.5 0.25 1.0 Carry Current Max DC/Peak AC Resist. Amps 1.5 1.0 2.0 Max DC/Peak AC Resist. Watts 10 3 50 Contact Rating Signal Level 1.0V, 10mA x 10 Ops. 500 100 1000 Static Contact Resistance (max. init.) 50mV, 10mA Ω 0.100 0.150 0.075 Dynamic Contact Resistance (max. init.) 0.5V, 50mA at 100 Hz, 1.5 msec Ω 0.200 0.200 0.100 Insulation Resistance (minimum) Between all Isolated Pins at 100V, 25°C, 40% RH Ω 1012 1011 1010 Capacitance - Typical Across Open Contacts Shield Floating Shield Guarding pF pF 1.0 0.3 2.0 1.0 1.4 0.2 Dielectric Strength (minimum) Between Contacts Contacts to Coil Contacts/Shield to Coil VDC/peak AC VDC/peak AC VDC/peak AC 350 350 1500 200 200 1500 1000 1000 1500 Operate Time - including bounce - Typical At Nominal Coil Voltage, 30 Hz Square Wave msec. 0.5 1.0 1.5 msec. 0.1 2.0 1.0 Life Expectancy-Typical 1 6 RELAY SPECIFICATIONS Release Time - Typical Top View: Grid = .1”x.1” (2.54mm x 2.54mm) 5 6 4 3 5 6 4 3 5 4 6 3 7 8 2 1 UP 7 8 2 1 7 8 2 1 Notes: Consult factory for life expectancy at other switching loads. Model 2904, 2911 and 2920, pin #7 is tied to optional electrostatic shield, pins #6 & #7 are tied to optional coaxial shield. 3 Model 2920 has Hg wetted contacts - position sensitive, must be mounted within 30° of vertical plane. See schematic. Hg Content per capsule: Form A, 0.04 grams. 1 2 Environmental Ratings: Storage Temp: -35°C to +100°C; Operating Temp: -20°C to +85°C; Solder Temp: 270°C max; 10 sec. max All electrical parameters measured at 25°C unless otherwise specified. Vibration: 20 G’s to 2000 Hz; Shock: 50 G’s 07082013 For most recent data visit www.cotorelay.com COTO TECHNOLOGY, INC.