DATA SHEET Part Number: SL32 0R540 Ordering Different Lead Types: Inside Kinked Leads Outside Kinked Leads Not Available Use -B after Ametherm’s part # For example: to order an inside kinked lead use part number SL32 0R540-B D D D T C B L S S S STRAIGHT LEADS OUTSIDE KINKED LEADS INSIDE KINKED LEADS Electrical Specifications: Mechanical Specifications: Resistance @ 25°C Max Steady State Current Up to 65°C Max Recommended Energy Rating (Joules) Actual Failure Point of Instantaneous Energy (Joules) Resistance @ 100% of Max Current Resistance @ 50% of Max Current Body Temperature @ 100% Current Rating Dissipation Constant Thermal Time Constant Material Type Max Recommended Capacitance @ 240/440 VAC 0.5 Ω ± 20% 40.0 A 250.0 J 495.0 J 0.008 Ω 0.038 Ω 234 °C 45.4Mw/°C 194 seconds “B” 4000µF/1250µF UL File Number: #E209153 D T Lead Diameter S L Straight Leads Coating Run Down B C 30.0 ± 2.5 mm 5.0 ± 1.0 mm 1.0 ± 0.1 mm 7.8 ± 2.0 mm 38.0 ± 9.0 mm 5.0 ± 1.0 mm 11.5 ± 3.50 mm 3.82 ± 1.0 mm Revision Date: March 19, 2003 Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701 Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670 www.ametherm.com