okpac® S/MON/SOB665200B/23/07/2012 page 1 / 6F/GB Relais statique biphasé de puissance Dual Power Solid State Relay SOB665200 Output : 24-600VAC 2x50A Input : 7.5-25VDC → Relais statique biphasé synchrone spécialement adapté aux charges résistives. Dual Zero Cross Solid State Relay especially designed for AC-51 resistive loads. → Sortie thyristors technologie TMS2(*) permettant une longue durée de vie: 24 à 600VAC 2x50A. Back to back thyristors on output with TMS2 (*) technology with a long lifetime expectancy: 24 to 600VAC 2x50A. → Entrée double avec LED de visualisation de couleur verte sur chaque entrée. 2 inputs with green LED visualization for each input. → Entrées doubles avec connecteur type CE100F ITWPANCON ou équivalent Double input with connector CE100F ITWPANCON type or equivalent → Protection IP20 par volets amovibles sur les bornes en option Etiquette repère disponible en option. IP20 protection by optional removable flaps on terminals with optional labels. → Construit en conformité aux normes IEC/EN60947-4-3 et EN60950/VDE0805 ; IEC 60335-1/ VDE0700-1 ; UL-cUL Designed in conformity with IEC/ EN60947-4-3 and EN60950/VDE0805 ; IEC 60335-1/ VDE0700-1 ; UL-cUL Livré sans connecteur de commande, ni volets Delivered without input connector and without flaps → Sur demande: Modèles avec protection en tension: (SOB665330); asynchrone (SOB7) On request : Voltage protection by TVS (SOB665330); Random models (SOB7). FILE Nr. E69913 Avec étiquette de repérage en option With optional labels REG.-Nr.10102 Dimensions Optional labels 1/L1 3/L2 1 2 3 4 2/T1 4/T2 CAD documents: www.celduc-relais.com/uk/plan3d.asp Pin 1==A1+ In1+ A1+ Pin 2 = A2Pin 3 = B1+ Pin 4 = B2Application typique: Résistance 24 kW (Catégorie AC-51) en 400VAC Typical application: 24 kW resistor (AC-51 load) on 400 VAC Le relais doit être monté sur dissipateur thermique. SSR must be mounted on heatsink (*) TMS2 =Thermo Mechanical Stress Solution Proud to serve you All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. celduc ® r e l a i s okpac® S/MON/SOB665200B/23/07/2012 page 2 / 6F/GB Input : Ic = f( Uc) Caractéristiques d'entrée / Control characteristics (at 25°C) par voie/ for each input Paramètre / Parameter DC Symbol Min Typ Max Tension de commande / Control voltage Uc 7.5 12 25 V Courant de commande / Control current (@ Uc ) Ic 6 10 24 mA Uc off 2 Tension de non fonctionnement / Release voltage LED d'entrée / Input LED Tension Inverse / Reverse voltage V verte / green Urv 32 Immunité / Input immunity : EN61000-4-4 2kV Immunité / Input immunity : EN61000-4-5 2KV Caractéristiques de sortie / Output characteristics (at 25°C) Paramètre / Parameter Plage de tension utilisation / Operating voltage range Tension de crête / Peak voltage ( clamping voltage) Niveau de synchronisme / Zero cross level Tension minimum amorçage / Latching voltage Courant nominal / nominal current (AC-51) Courant surcharge / Non repetitive overload current Chute directe à l'état passant / On state voltage drop Tension seuil à l'état passant /On state Threshold voltage Unit Conditions V par voie/ for each output Ie nom Heater tp=10ms (Fig. 3) (Ie = nominal current) Symbol Ue Up Usync Ua Ie AC-51 Itsm V @ 25°C Vto 0.85 V rt 7.5 mΩ Résistance dynamique / On state dynamic resistance Puissance dissipée (max) / Output power dissipation (max value) Résistance thermique jonction/semelle Thermal resistance between junction to case @Ue typ, 50Hz Courant de fuite à l'état bloqué / Off state leakage current Courant minimum de charge / Minimum load current Temps de fermeture / Turn on time @Ue typ, 50Hz @Ue typ, 50Hz Temps d'ouverture / Turn off time Fréquence réseau/ Mains frequency range F mains dv/dt à l'état bloqué / Off state dv/dt di/dt max / Maximum di/dt non repetitive I2t (<10ms) : Value for fusing Immunité / Conducted immunity level IEC/EN61000-4-4 (bursts) Immunité / Conducted immunity level IEC/EN61000-4-5 (surge) Protection court-circuit / Short circuit protection voir/see page 5 Pd Min 24 1200 Typ. 400 35 10 530 50 50 580 0.85 + 0,0075xIe 0.765xIe + 0,0048xIe² Rthj/c Ilk Iemin ton max toff max f dv/dt di/dt I2t Example Max 600 W 0.55 K/W 1 mA mA ms ms Hz V/µs A/µs 5 0,1 500 50-60 1404 1680 2kV criterion B 2kV criterion B Unit V rms V V V A rms A V 10 10 800 50 A 2s Fuse FERRAZ gRC 40A 22x58 Caractéristiques générales / General characteristics (at 25°C) Isolement entrée/sortie - Input to output insulation Isolation sortie/ semelle - Output to case insulation Résistance Isolement / Insulation resistance Tenue aux tensions de chocs / Rated impulse voltage Degré de protection / Protection level / CEI529 Degré de pollution / Pollution degree Vibrations / Vibration withstand 10 -150 Hz according to IEC 60068-2-6 Tenue aux chocs / Shocks withstand according to IEC 60068-2-27 Température de fonctionnement /Ambient temperature (no icing, no condensation) Température de stockage/ Storage temperature (no icing, no condensation) Humidité relative / Ambient humidity Poids/ Weight Conformité CE / CE Conformity Conformité USA / US Conformity Conformité normes ferroviaires/ Conformity to railways applications Plastique du boitier / Housing Material Semelle / Base plate celducâ Ui Ui Ri Uimp sine test 11ms HR 4000 4000 1000 (@500VDC) 4000 IP20 2 10 > 30 .... 50 -55 /+100 -55/+125 40 to 85 80 IEC/ EN60947-4-3 UL/cUL yes (consult us) PA 6 UL94VO Aluminium, Tinned-plated VRMS VRMS MΩ V g g °C °C % g www.celduc.com r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19 okpac® S/MON/SOB665200B/23/07/2012 page 3 / 6F/GB Fig. 2 Courbes thermiques & Choix dissipateur thermique / Thermal curves and heatsink choice Dissipateurs celduc standard/ Standard celduc heatsinks: - 6K/W correspond à un relais monté sur un adaptateur DIN celduc type 1LD12020 6K/W corresponds to a relay mounted on a DIN rail adapter like celduc 1LD12020 - WF210000/ WF151200 = 2.1- 2.2K/W - WF121000 /WF108110 =1.1-1.2K/W - WF070000 = 0.75K/W - WF050000 = 0.55K/W - WF115100 = 0.9K/W - WF031x = 0.3K/W fig 3 : Courants de surcharges / Overload currents 1 - Itsm non répétitif sans tension réappliquée est donné pour la détermination des protections. 1 - No repetitive Itsm is given without voltage reapplied . This curve is used to define the protection (fuses). 2 -Itsm répétitif est donné pour des surcharges de courant (Tj initiale=70°C). Attention : la répétition de ces surcharges de courant diminue la durée de vie du relais. 2 - Repetitive Itsm is given for inrush current with initial Tj = 70°C. In normal operation, this curve musn't be exceeded. Caution, frequent over load currents will decrease the life expectancy of the SSR. → Attention ! les relais à semi-conducteurs ne procurent pas d'isolation galvanique entre le réseau et la charge. Ils doivent être utilisés associés à un disjoncteur avec propriété de sectionnement ou similaire, afin d'assurer un sectionnement fiable en amont de la ligne dans l'hypothèse d'une défaillance et pour tous les cas où le relais doit être isolé du réseau (maintenance; non utilisation sur une longue durée...). Sous réserve d'installation, d'entretien et d'utilisation conformes à sa destination, à la réglementation, aux normes en vigueur, aux instructions du constructeur et aux règles de l'art. → Warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. Always use in conjunction with an adapted circuit breaker with insulation feature or a similar device in order to ensure a reliable insulation in the event of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...). It is important that the solid state relay is subject to correct installation, maintenance and use conforming to its intended regulations and standards, to the supplier's instructions and to accepted rules of art. celducâ www.celduc.com r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19 okpac® S/MON/SOB665200B/23/07/2012 page 4 / 6F/GB Raccordement / Connections okpac® Raccordement d'entrée / Control wiring 2 = ITW PANCON CE100F24-4 3= or equivalent TYCO C-3-640440-4 okpac® Raccordement de puissance / Power wiring Nombre de fils / Number of wires 1 Fil rigide (sans embout) SOLID (No ferrule) Modèle de tournevis / Couple de serrage Screwdriver type recommandé Vis M5 2 Fil multibrins (avec embout) FINE STRANDED (With ferrule) Fil rigide (sans embout) SOLID (No ferrule) Fil multibrins (avec embout) FINE STRANDED (With ferrule) Recommended Tightening Torque M5 screw N.m 2 1,5 ... 10 mm AWG16....AWG8 2 1,5 ... 6 mm AWG16....AWG10 2 1,5 ... 10 mm AWG16....AWG8 2 1,5 ... 6 mm AWG16....AWG10 Directement avec fils avec ou sans embouts/ Direct connection with wires with or without ferrules Puissance avec cosses / Power with ring terminals. POZIDRIV 2 Mini 2 / Typ 2.4 / Max 3 Avec cosses/ With ring terminals Volets IP20 / IP20 flaps Les volets 1K453000 sont à commander séparément Flaps reference 1K453000 must be ordered separately. W max =12,6mm Etiquettes/ Labels: 16 mm2 (AWG6) 25 mm2 (AWG4) 35mm2 (AWG2 /AWG3) 50mm2 (AWG0 /AWG1) Des cosses et kits d'adaptation peuvent être fournis : voir relais forte puissance et documentation connexion forte puissance/ Suitable ring terminals and special kit for high current can be delivered: see high power SSR and data-sheet for power connection. Des étiquettes de repérage sont aussi disponibles. Quantités par 200 pièces Montage sur volets (1MZ09000). Marking labels are available, for mounting on flaps. Part number : 1MZ09000 (delivered per 200 parts) FASTONS : Nous consulter / Consult us celducâ www.celduc.com r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19 okpac® S/MON/SOB665200B/23/07/2012 page 5 / 6F/GB Montage / Mounting: −> Les relais statiques de la gamme okpac® doivent être montés sur dissipateur thermique. Une gamme étendue de dissipateurs est disponible. Voir exemples ci dessous et la gamme "WF" sur www.celduc.com. okpac® SSRs must be mounted on heatsinks. A large range of heatsinks is available. See below some examples and "WF" range on www.celduc.com. −> Pour le montage du relais sur dissipateur utiliser de la graisse thermique ou un "thermal pad" haute performance spécifié par celduc® . Une version autocollante précollée sur le relais (5TH23000) est aussi disponible: nous consulter For heatsink mounting, it is necessary to use thermal grease or thermal pad with high conductibility specified by celduc®. An adhesive model (5TH23000) mounted by celduc® on the SSR is also available: please contact us. M4x12mm 1,2N.m mini Thermal grease or pad Poussez et fermer. Push and close Thermal pads : 5TH21000 1LD12020 Utilisation des volets IP20 IP20 flaps using Adaptateur DIN DIN rail adaptator Heatsinks : WF151200 (2-2,5 K/W) WF108110 (1.2 K/W) WF115100 (0.9K/W) WF031x (0.3 K/W) Application typique / Typical LOAD −> Les produit SOB6 sont définis principalement pour charge résistive AC-51 (chauffage). SOB9 products are specially designed for AC-51 résistive load (heating). Protection / Protection : −> La protection d'un relais statique contre les court-circuits de la charge peut être faite par fusibles rapides avec des I2t = 1/2 I2t du relais . Un test en laboratoire a été effectué sur les fusibles de marque FERRAZ. Une protection par MCB ( disjoncteurs modulaires miniatures) est aussi possible. Voir notre note application ( protection SSR) et utiliser des relais avec I2t >5000A2s To protect the SSR against a short-circuit of the load , use a fuse with a I2t value = 1/2 I2t value specified page 2. A test has been made with FERRAZ fuses . It is possible to protect SSR by MCB ( miniature circuit breaker). In this case, see application note ( SSR protection) and use a SSR with high I2t value (5000A2s minimum). celducâ www.celduc.com r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19 okpac® S/MON/SOB665200B/23/07/2012 page 6 / 6F/GB CEM / EMC : −> Immunité : Nous spécifions dans nos notices le niveau d'immunité de nos produits selon les normes essentielles pour ce type de produit, c'est à dire EN61000-4-4 &5. Immunity : We give in our data-sheets the immunity level of our SSRs according to the main standards for these products: EN61000-4-4 &5. −> Emission: Nos relais statiques sont principalement conçus et conformes pour la classe d'appareils A (Industrie). L'utilisation du produit dans des environnements domestiques peut amener l'utilisateur à employer des moyens d'atténuation supplémentaires. En effet, les relais statiques sont des dispositifs complexes qui doivent être interconnectés avec d'autres materiels (charges, cables, etc) pour former un système. Etant donné que les autres materiels ou interconnexions ne sont pas de la responsabilité de celduc®, il est de la responsabilité du réalisateur du système de s'assurer que les systèmes contenant des relais statiques satisfont aux prescriptions de toutes les règles et règlements applicables au niveau des systèmes. Consulter celduc® qui peut vous conseiller ou réaliser des essais dans son laboratoire sur votre application. Emission: celduc® SSRs are mainly designed in compliance with standards for class A equipment (Industry). Use of this product in domestic environments may cause radio interference. In this case the user may be required to employ additionnal devices to reduce noise. SSRs are complex devices that must be interconnected with other equipment (loads, cables, etc.) to form a system. Because the other equipment or the interconnections may not be under the control of celduc®, it shall be the responsability of the system integrator to ensure that systems containing SSRs comply with the requirement of any rules and regulations applicable at the system level. Consult celduc® for advices. Tests can be performed in our laboratory. celducâ www.celduc.com r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19