DELTA P/N : SIQ125R Series Mechanical dimensions Dimensions (Unit : mm) A 12.2 ± 0.3 B 6.0 MAX C 12.2 ± 0.3 D 7.6 ± 0.3 E 5.0 F 2.2 G 5.4 H 7.0 I 12.8 Electrical Characteristics @25℃ , 100KHz, 0.1V for0.47~8.2uH and SIQ125RA, 1KHz,1V for 10~1000uH 1. 2. 3. Delta P/N L1 (uH) R47 R82 1R3 2R1 2R8 3R1 4R0 4R4 4R7 5R8 7R5 8R2 100 120 150 180 220 270 330 390 470 560 680 820 101 121 151 181 221 271 331 391 471 561 681 821 102 0.47 0.82 1.3 2.1 2.8 3.1 4.0 4.4 4.7 5.8 7.5 8.2 10 12 15 18 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 SIQ125R DCR Irated2 (mΩ) MAX (Adc) 12 14 8 7 17 6 20 5 21 24 4.4 4.2 25 27 30 34 40 51 57 68 75 110 120 140 160 170 230 290 400 460 510 690 770 860 1200 1340 1530 4 3.5 3.3 3 2.8 2.3 2.1 2 1.8 1.7 1.5 1.4 1.3 1.1 1.0 0.9 0.8 0.75 0.68 0.65 0.58 0.54 0.48 0.43 0.40 SIQ125RA DCR Irated3 (mΩ) MAX (Adc) 2.2 18.5 3.2 16.8 4 15 5.3 8 8.1 7 10 6 15 21 8 7 23 25 6 5 33 45 47 4.2 4.2 3.8 57 3 140 2.1 Tolerance of inductance : +30%/-20% for 0.47~8.2uH, ±20% for 10~1000uH. Irated is the DC current which cause the inductance drop less than 25% of it’s nominal inductance without current and the surface temperature of the part increase less than 45 ℃. Operating temperature: -40℃ to 125℃ (Self-temperature rise included).