SIQ125R

DELTA P/N : SIQ125R Series
Mechanical dimensions
Dimensions (Unit : mm)
A
12.2 ± 0.3
B
6.0 MAX
C
12.2 ± 0.3
D
7.6 ± 0.3
E
5.0
F
2.2
G
5.4
H
7.0
I
12.8
Electrical Characteristics @25℃ , 100KHz, 0.1V for0.47~8.2uH and SIQ125RA, 1KHz,1V for 10~1000uH
1.
2.
3.
Delta P/N
L1
(uH)
R47
R82
1R3
2R1
2R8
3R1
4R0
4R4
4R7
5R8
7R5
8R2
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
0.47
0.82
1.3
2.1
2.8
3.1
4.0
4.4
4.7
5.8
7.5
8.2
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
SIQ125R
DCR
Irated2
(mΩ) MAX
(Adc)
12
14
8
7
17
6
20
5
21
24
4.4
4.2
25
27
30
34
40
51
57
68
75
110
120
140
160
170
230
290
400
460
510
690
770
860
1200
1340
1530
4
3.5
3.3
3
2.8
2.3
2.1
2
1.8
1.7
1.5
1.4
1.3
1.1
1.0
0.9
0.8
0.75
0.68
0.65
0.58
0.54
0.48
0.43
0.40
SIQ125RA
DCR
Irated3
(mΩ) MAX
(Adc)
2.2
18.5
3.2
16.8
4
15
5.3
8
8.1
7
10
6
15
21
8
7
23
25
6
5
33
45
47
4.2
4.2
3.8
57
3
140
2.1
Tolerance of inductance : +30%/-20% for 0.47~8.2uH, ±20% for 10~1000uH.
Irated is the DC current which cause the inductance drop less than 25% of it’s nominal inductance without current
and the surface temperature of the part increase less than 45 ℃.
Operating temperature: -40℃ to 125℃ (Self-temperature rise included).