Hygro-Thermometer Datalogger Model 4465CFA

User's Guide
Hygro-Thermometer Datalogger
Model 4465CFA
4465CFA
76
P
75.0
o
F
Hygro-Thermometer
+ DewPoint
TEMP
HOLD
DEW
READ
MEMORY
Introduction
Congratulations on your purchase of the Extech 4465CFa Hygro-Thermometer. The
Extech Hygro-Thermometer measures and displays Temperature and Relative Humidity.
In addition, Dew Point Temperature is calculated and displayed. The meter incorporates
a 99 memory storage feature whereby temperature, humidity, and dew point readings
can be stored for later recall. This meter is shipped fully tested and calibrated and, with
proper use, will provide years of reliable service.
Safety Information
• Please read the following safety information carefully before attempting to operate or
service the meter.
• Use the meter only as specified in this manual; otherwise, the protection provided by
the meter may be impaired.
Environmental Conditions
•
Altitude: 6562 ft (2000 meters) max.
•
Relative Humidity: 95% max.
•
Ambient operation: 32 to 140 F (0 to 60 C)
•
For indoor use only
o
o
Maintenance and Cleaning
Repairs or servicing not covered in this user guide should be performed by qualified
personnel. Periodically wipe the case with a dry cloth. Do not use abrasives or
solvents.
Safety Symbols
Complies with EMC
2
4465CFa V3.0 3/06
Meter Description
1. Temperature and Humidity Sensor
1
2. Multifunction LCD Display
3. Temperature (TEMP), Relative Humidity (%RH), and Dew
Point Temperature (DEW) Select Switch
4. Temperature units Select Switch (C/F)
5. READ push-button for use with built-in datalogger. Also
functions as Down arrow button for scrolling stored data
6. MEMORY push-button for use with built-in datalogger. Also
functions as Up arrow button for scrolling stored data
7. HOLD ON/OFF switch
4465CFA
2
76
P
75.0
o
F
Hygro-Thermometer
+ DewPoint
The battery compartment and the tripod mount are located on
the rear of the instrument.
3
TEMP
4
5
DEW
HOLD
READ
7
MEMORY
6
Display Description
8
1. Primary Display
9
10
11
2. Secondary Display
FULL RECORD HOLD
3. Auto Power OFF active
4. Memory Location Counter (0-99)
5. Read mode
7
6. Memory mode
6
M
7. Low Battery indicator
5
R
8. Memory full indicator
9. Record Mode active icon
45.0
99 P
4
10. Data Hold mode active icon
3
DEW
1
%RH
75.0
F
2
11. Dew Point Temperature mode
3
4465CFa V3.0 3/06
Operation
Getting Started
1. Set the TEMP, %RH, DEW switch to the desired measurement position.
•
TEMP position: Temperature reading shown on Primary display (top); Relative
Humidity % is shown on Secondary display (lower).
•
%RH position: Relative Humidity % shown on Primary display; Temperature is
shown on the Secondary display
•
DEW position: Dew Point temperature shown on Primary display; Relative
Humidity % shown on Secondary display.
2. Set the HOLD-ON-OFF switch to the ON position. If the display does not switch on
please check that the 9V battery is installed and is fresh.
3. Set the °C/°F selector switch to the desired unit of measure for temperature.
4. The Humidity and Temperature sensors are contained in the tip of the meter. Mount or
hold the meter in the area to be tested. For convenience, a standard tripod mount is
located at the rear of the meter.
5. Allow time for relative humidity readings to stabilize (3 to 5 minutes, typically).
6. When the low battery icon
+
–
flashes on the LCD, replace the 9V battery.
Data Hold
Set the HOLD-ON-OFF switch to the HOLD position to freeze a displayed reading. The
HOLD icon will appear on the LCD display. Move the switch to the ON position to continue
normal operation (the HOLD icon will switch off).
MEMORY READ Feature
Two front panel pushbuttons (MEMORY and READ) control the storage and retrieval of
readings. The MEMORY and READ buttons double as DOWN
and UP
arrow keys
for navigating the meter’s memory locations. Up to 99 readings can be stored and recalled.
Storing a reading
Momentarily press the MEMORY button to store the current reading (the M icon will
flash on the LCD display). The memory location number (0 - 99) is always shown on the
lower left side of the LCD display for easy reference. Each time the MEMORY button is
pressed the meter beeps and the location number increments by one. When the
memory is filled, the meter beeps twice and the display will flash the icon FULL.
Viewing stored readings
To view stored readings, the meter must first be placed in the READ mode by
momentarily pressing the READ button (the R icon will appear on the LCD). Now, use
the DOWN
arrow button to step through the storage locations. Use the UP arrow
button to jump ten (10) readings at a time. To exit the READ mode, press and hold the
READ button for 3 seconds until two beeps are heard (the R display icon will switch off).
Please note that the memory can only be read in reverse order (99 first down to 1.)
Clearing all stored readings
With the meter off, press and hold the MEMORY button while turning the meter on. The
CLr (clear) display icon will appear. Release the MEMORY button; all of the readings
stored in the meter are now erased.
Battery Replacement
The Battery Compartment is located on the lower back of the instrument housing. Slide the
compartment cover off in the direction of the arrow. Replace the 9V battery and secure the
appears on the display when the battery
compartment cover. The low battery symbol
requires changing.
+
4
–
4465CFa V3.0 3/06
Calibration
Separate calibration documentation is available covering the calibration procedures for this
instrument. Contact the Extech Technical Support department for additional information.
Automatic Power OFF
The meter automatically shuts off after a 10 minute period of inactivity. To disable this
feature, hold the READ button while turning the meter on. The ‘P’ display icon appears and
the meter beeps when the Auto Power OFF feature is enabled.
Specifications
General Specifications
Display
Multi-function LCD display
Measurement
Relative Humidity% (RH), Temperature (°C & °F),
and Dew Point Temperature (°C & °F)
Data Hold
Freezes Display
Data Storage
99 readings can be stored and recalled
Response Time
Humidity
45% to 95%: ≤ 3 minutes
Measurement rate
2.5 readings per second
95% to 45%: ≤ 5 minutes
Operating Temperature 32 to 122°F (0 to 50 °C)
Operating Humidity
< 80% RH
Storage Temperature
14 to 140°F (-10 to 60°C)
Storage Humidity
< 70% RH
Power Supply
9V battery
Battery life
400 hours (approx.)
Weight
7.0 oz. (198 g)
Size
10.6 x 2.7 x1.0" (180 x 72 x 32mm)
Measurement Specifications
% Relative
Humidity
Temperature
Range
Resolution
Accuracy
10% to 95% RH
0.1% RH
30 to 95% RH: ±3% RH
10 to 30% RH: ±5% RH
ο
ο
ο
-4 F to 140 F
(-20οC to 60 οC)
0.1 F/C
Dew Point -56 οF to 140 οF
Temperature (-49οC to 60 οC)
0.1ο F/C
5
±1.5 οF (±0.8οC)
4465CFa V3.0 3/06
Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and
workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables).
If it should become necessary to return the instrument for service during or beyond the warranty period,
contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website
www.extech.com for contact information. A Return Authorization (RA) number must be issued before any
product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper
packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the
user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or
unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for
a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's
total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no
other warranty, whether written or oral, is expressed or implied.
Calibration and Repair Services
Extech offers repair and calibration services for the products we sell. Extech also
provides NIST certification for most products. Call the Customer Service Department for
information on calibration services available for this product. Extech recommends that
annual calibrations be performed to verify meter performance and accuracy.
Support line (781) 890-7440
Technical support: Extension 200; E-mail: [email protected]
Repair & Returns: Extension 210; E-mail: [email protected]
Product specifications subject to change without notice
For the latest version of this User’s Guide, Software updates, and other
up-to-the-minute product information, visit our website: www.extech.com
Copyright © 2006 Extech Instruments Corporation
All rights reserved including the right of reproduction in whole or in part in any form.
6
4465CFa V3.0 3/06