EXTECH RH490

User's Guide
Precision Hygro-Thermometer
Model RH490
Introduction
Congratulations on your purchase of the Extech RH490 Precision HygroThermometer. This device measures Humidity, Air Temperature, Dew Point
temperature, Wet Bulb temperature and Grains of Water Vapor Per Pound of Air.
Advanced features include Data Hold, Auto Power Off, and MAX/MIN reading. This
meter is shipped fully tested and calibrated and with proper use will provide years
of reliable service.
Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free
of defects in parts and workmanship for one year from date of shipment (a six
month limited warranty applies to sensors and cables). If it should become
necessary to return the instrument for service during or beyond the warranty
period, contact the Customer Service Department at (781) 890-7440 ext. 210 for
authorization or visit our website www.extech.com for contact information. A
Return Authorization (RA) number must be issued before any product is returned
to Extech. The sender is responsible for shipping charges, freight, insurance and
proper packaging to prevent damage in transit. This warranty does not apply to
defects resulting from action of the user such as misuse, improper wiring,
operation outside of specification, improper maintenance or repair, or
unauthorized modification. Extech specifically disclaims any implied warranties
or merchantability or fitness for a specific purpose and will not be liable for any
direct, indirect, incidental or consequential damages. Extech's total liability is
limited to repair or replacement of the product. The warranty set forth above is
inclusive and no other warranty, whether written or oral, is expressed or implied.
Copyright © 2006 Extech Instruments Corporation
All rights reserved including the right of reproduction in whole or in part in any form.
2
RH490 V2.0 12/06
Meter Description
1.
Humidity & Temperature Sensor
2.
LCD Display
3.
Power ON/OFF button
4.
°F/°C/WBT (wet bulb)/Dew Point button
5.
Hold/MIN-MAX button
6.
%RH, GPP, g/Kg, Backlight button
Note: The battery compartment is located
on the rear of the instrument
Display Description
Relative Humidity %
Dew Point
3. Wet Bulb
4. °C/°F
5. Temp/WB/DP Display
6. Maximum
7. Minimum
8. Low Battery
9. Hold
10. RH% Display
11. Auto Off
12. Grains per pound
1.
2.
3
RH490 V2.0 12/06
Operation
Power
Press the power button “
“ to turn power on or off.
%RH
1. To select %RH measurement, press the
“%RH/GPP/g/Kg” button.
2. Hold the probe in the area to be tested.
3. Allow adequate time for readings to stabilize.
4. The Relative Humidity measurement appears in the
top display.
5. Pressing the “°F/°C/WBT/Dew Point” button
toggles the lower display between Temperature
(°F), Temperature (°C), Dew Point (°C), Dew Point
(°F), Wet Bulb (°C) and Wet Bulb (°F).
Mixing Ratio (Grains Per Pound or Grams Per Kilograms)
1. To select GPP or g/kg measurement, press the
“%RH/GPP/g/Kg” button.
2. Hold the probe in the area to be tested.
3. Allow adequate time for readings to stabilize.
4. The GPP or g/Kg measurement appears in the top
display.
5. Pressing the “°F/°C/WBT/Dew Point” button
toggles the lower display between Temperature
(°F), Temperature (°C), Dew Point (°C), Dew Point
(°F), Wet Bulb (°C) and Wet Bulb (°F).
4
RH490 V2.0 12/06
Dew Point
1. To select the Dew Point measurement, press the
“°F/°C/WBT/Dew Point” button until DEWPOINT
(°F or °C) appears in the lower right.
2. Dew Point temperature is now displayed.
Wet Bulb
1. To select the Wet Bulb measurement, press the
“°F/°C/WBT/Dew Point” button until WET BULB
(°F or °C) appears in the lower right.
2. Wet Bulb temperature is now displayed.
Temperature
1.
2.
To select the temperature measurement, press the
“°F/°C/WBT/Dew Point” button until “°C” or “°F”
appears in the lower right.
Temperature is now displayed.
Data Hold
1. Press the ”H MAX MIN” button momentarily to
freeze the displayed readings. ”HOLD” will appear
on the upper left-hand side of the display.
2. Press the ”H MAX MIN” button three more times to
return to normal operation. (Steps through MAX
and MIN)
5
RH490 V2.0 12/06
Minimum (MIN) Maximum (MAX) Function
The MIN/MAX mode allows the user to view only the lowest (MIN) or highest
(MAX) readings.
1. Press the ”H MAX MIN” button twice and “MIN” appears on the display. The
LCD is now displaying the minimum value recorded in both the top and
bottom display. The display will not change until a lower reading is
registered.
2. Press the ”H MAX MIN” button again and “MAX”
appears on the display. The LCD is now displaying
the maximum value recorded in both the top and
bottom display. The display will not change until a
higher reading is registered.
3. To exit the MIN/MAX mode, press the ”H MAX
MIN” button again. The “MAX” icon will disappear.
Note: Max and Min values are recorded into memory
while the meter is on. The values are erased
when power is turned off.
Backlight
Press and hold the light button “
“ until the backlight turns on. To turn the
backlight off, press and hold the light button “
“ until the backlight turns off.
Automatic Power OFF
The meter has a default setting that automatically shuts the meter off after 10
minutes (indicated by the
symbol on the display).
This battery saving feature can be disabled.
To disable the auto power off function, press and hold the ”H MAX MIN” hold
button while powering on. The
symbol will not appear when auto power off
has been disabled.
The meter will revert to the default auto-off mode when powered off.
Maintenance
Cleaning and storage
1. The meter should be cleaned with a damp cloth and mild detergent when
necessary. Do not use solvents or abrasives.
2. Store the meter in an area with moderate temperature and humidity (refer to
the operating and storage range in the specifications chart earlier in this
manual).
Battery Replacement
When the battery becomes weak the “
“ battery symbol will appear on the
LCD. Replace the 9 Volt battery by removing the Philips head screw holding the
rear battery compartment cover to access the battery compartment. Ensure that
the compartment cover is securely fastened when finished.
6
RH490 V2.0 12/06
Specifications
Function
Range and Resolution
Accuracy
Humidity
0.0 to 10.0%RH
±3%RH
Temperature
Wet Bulb
10.0 to 90.0%RH
±2%RH
90.0 to 100.0%RH
±3%RH
-22.0 to – 3.9oF
-30.0 to -19.9oC
o
±2.7 F
o
±1.5 C
-4.0 to 158.0oF
-20.0 to 70.0oC
±1.8 F
±1oC
158.1 to 199.0oF
70.1 to 100.0oC
o
±2.7 F
±1.5oC
o
32 to 176°F (0 to 80°C)
Dew Point
Mixing Ratio
-22 to 199°F (-30 to 100°C)
Calculated from RH and air
0 to 1120 GPP (grains per pound) temperature measurements
0 to 160 g/kg (grams per kilogram)
Display
Dual LCD
Response Time:
<30 seconds (90% of final value in moving air)
o
o
Operating Conditions 32 to 122 F (0 to 50 C); < 80% RH non-condensing
Storage Conditions -40 to 185oF (-40 to 85oC); <99% RH non-condensing
Power Supply
9 Volt battery
Battery Life
Approx. 24 hours
Dimensions / Weight 7.8 x 1.7 x 1.3” (200 x 45 x 33mm); 7 oz. (200g)
Calibration and Repair Services
Extech offers repair and calibration services for the products we sell. Extech
also provides NIST certification for most products. Call the Customer Service
Department for information on calibration services available for this product.
Extech recommends that annual calibrations be performed to verify meter
performance and accuracy.
Support line (781) 890-7440
Technical support: Extension 200; E-mail: [email protected]
Repair & Returns: Extension 210; E-mail: [email protected]
Product specifications subject to change without notice
For the latest version of this User’s Guide, Software updates, and other
up-to-the-minute product information, visit our website: www.extech.com
7
RH490 V2.0 12/06