Film Capacitors Metallized Polyester Film Capacitors (MKT) Series/Type: B32932 ... B32936 Date: August 2015 © EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Metallized Polyester Film Capacitors (MKT) B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Typical applications For connection in series with the mains For severe ambient conditions Capacitive power supply applications Energy meters Dimensional drawing Climatic Max. operating temperature: 105 °C Climatic category (IEC 60068-1): 40/105/56 Features High stability of capacitance value X2 safety approval (up to 2.2 µF) RoHS-compatible Dimensions in mm Construction Dielectric: metallized polyester Internal series connection Plastic case (UL 94 V-0) Epoxy resin sealing, flame-retardant Terminals Parallel wire leads, lead-free tinned Standard lead lengths: 6 1 mm Special lead lengths available on request Lead spacing ±0.4 Lead diameter d1 ±0.05 Type 15 0.8 B32932 22.5 0.8 B32933 27.5 0.8 B32934 37.5 1.0 B32936 Marking examples Marking Manufacturer's logo, lot number, date code, rated capacitance (coded), capacitance tolerance (code letter), rated AC voltage (IEC), series number, sub-class (X2), dielectric code (MKT), climatic category Delivery mode Bulk (untaped, lead length 6 - 1 mm) Taped (Ammo pack or reel) Approvals Approval mark Standards Certificate EN 60384-14 IEC 60384-14 40028058 UL 60384-14 E97863 CSA E60384-14:09 E97863 Note: X2 safety approval for C ≤ 2.2 µF Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Overview of available types Lead spacing 15 mm 22.5 mm 27.5 mm 37.5 mm Type B32933 B32934 B32936 B32932 CR (µF) 0.047 0.068 0.10 0.15 0.22 0.33 0.47 0.56 0.68 0.82 1.0 1.5 2.2 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Ordering codes and packing units Lead CR spacing mm µF Max. dimensions w×h×l mm Ordering code (composition see below) 15 5.0 × 10.5 × 18.0 5.0 × 10.5 × 18.0 6.0 × 11.0 × 18.0 7.0 × 12.5 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.0 11.0 × 18.5 × 18.0 6.0 × 15.0 × 26.5 6.0 × 15.0 × 26.5 7.0 × 16.0 × 26.5 7.0 × 16.0 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 10.5 × 18.5 × 26.5 12.0 × 22.0 × 26.5 12.0 × 22.0 × 26.5 14.5 × 29.5 × 26.5 14.5 × 29.5 × 26.5 B32932A3473+*** B32932A3683+*** B32932A3104+*** B32932A3154+*** B32932A3224+*** B32932A3334+*** B32932A3474M*** B32933A3104+*** B32933A3154+*** B32933A3224+*** B32933A3334+*** B32933A3474M*** B32933B3474+*** B32933A3564+*** B32933A3684+*** B32933A3824+*** B32933A3105M*** B32933B3105+*** B32933A3155+*** 22.5 0.047 0.068 0.10 0.15 0.22 0.33 0.47 0.10 0.15 0.22 0.33 0.47 0.47 0.56 0.68 0.82 1.0 1.0 1.5 Ammo Straight pack terminals, pcs./MOQ Reel pcs./MOQ 4680 5200 4680 5200 3840 4400 3320 3600 2720 2800 2560 2800 – 2200 2720 2800 2720 2800 2320 2400 2320 2400 1920 2000 1560 1600 1560 1600 1560 1600 – – – – – – – – Straight X2 terminals, safety Untaped appr. pcs./MOQ 4000 X 4000 X 4000 X 4000 X 2000 X 2000 X 1200 X 2880 X 2880 X 2520 X 2520 X 2040 X 2160 X 2160 X 2160 X 1800 X 1800 X 1040 X 1040 X X = approval granted MOQ = Minimum Order Quantity, consisting of 4 packing units. Further intermediate capacitance values on request. Composition of ordering code + = Capacitance tolerance code: M = ±20% K = ±10% Please read Cautions and warnings and Important notes at the end of this document. *** = Packaging code: 289 = Straight terminals, Ammo pack 189 = Straight terminals, Reel 000 = Straight terminals, Untaped (standard lead length 6 1 mm) Page 4 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Ordering codes and packing units Lead CR spacing mm µF Max. dimensions w×h×l mm Ordering code (composition see below) 27.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 21.0 × 31.5 13.5 × 23.0 × 31.5 14.0 × 24.5 × 31.5 18.0 × 27.5 × 31.5 12.0 × 22.0 × 41.5 12.0 × 22.0 × 41.5 14.0 × 25.0 × 41.5 B32934A3474+*** B32934A3564+*** B32934A3684+*** B32934A3824+*** B32934A3105M*** B32934B3105+*** B32934B3155M*** B32934D3155+*** B32934B3225+*** B32936A3105+*** B32936A3155+*** B32936A3225+*** 37.5 0.47 0.56 0.68 0.82 1.0 1.0 1.5 1.5 2.2 1.0 1.5 2.2 Ammo Straight pack terminals, pcs./MOQ Reel pcs./MOQ – 1400 – 1400 – 1400 – 1400 – 1400 – 1400 – 1200 – – – – – – – – – – Straight X2 terminals, safety Untaped appr. pcs./MOQ 1280 X 1280 X 1280 X 1280 X 1280 X 1280 X 1120 X 1040 X 800 X 1620 X 1620 X 1380 X X = approval granted MOQ = Minimum Order Quantity, consisting of 4 packing units. Further intermediate capacitance values on request. Composition of ordering code + = Capacitance tolerance code: M = ±20% K = ±10% Please read Cautions and warnings and Important notes at the end of this document. *** = Packaging code: 289 = Straight terminals, Ammo pack 189 = Straight terminals, Reel 000 = Straight terminals, Untaped (standard lead length 6 1 mm) Page 5 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Technical data Max. operating temperature Top,max (Top = Tamb + self-heating) +105 °C Dissipation factor tan δ (in 10-3) at 20 °C (upper limit values) tan δ 1 kHz 10 kHz C ≤ 1 µF 8 15 C > 1 µF 8 Insulation resistance Rins or time constant τ = CR Rins at 20 °C, rel. humidity ≤ 65% (minimum as-delivered values) CR ≤ 0.33 µF CR > 0.33 µF 30000 MΩ 10000 s DC test voltage 1312 V DC, 2 s (4.3 VR according to IEC 60384-14) Passive flammability category to IEC 40 (CO) 752 B Capacitance tolerances (measured at 1 kHz) ±10% (K), ±20% (M) Rated AC voltage ( IEC 60384-14 ) 305 V (50/60 Hz) Operating voltage Vop at high temperature TA ≤ 105 °C Vop = 1.25 VAC (1000 h) Damp heat test Test conditions 1. Temperature: Relative humidity (RH): Test duration: Voltage value: +85 °C ±2 °C 85% ±2% 1000 hours 240 V AC, 50 Hz 2. Temperature: Relative humidity (RH): Test duration: Voltage value: +40 °C ±2 °C 93% ±2% 2000 hours 305 V AC, 50 Hz Limit values after damp heat test Reference standard Please read Cautions and warnings and Important notes at the end of this document. Capacitance change (∆C/C): Dissipation factor change (∆tan δ): ∆tan δ/tan δ: Insulation resistance Rins or time constant τ = CR Rins: AEC-Q200 Page 6 of 18 ≤ 10% ≤ 5 10-3 (at 1 kHz) ≤ 100% (at 10 kHz) > 10 MΩ B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed in V/µs. "k0" represents the maximum permissible pulse characteristic of the waveform applied to the capacitor, expressed in V2/µs. Note: The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the capacitor. dV/dt and k0 values Lead spacing (mm) dV/dt (V/µs) k0 (V2/µs) Please read Cautions and warnings and Important notes at the end of this document. 15 90 108000 22.5 50 60000 Page 7 of 18 27.5 35 42000 37.5 25 30000 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Mounting guidelines 1 Soldering 1.1 Solderability of leads The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1. Before a solderability test is carried out, terminals are subjected to accelerated ageing (to IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far higher than the upper category temperature of the capacitors, the terminal wires should be cut off from the capacitor before the ageing procedure to prevent the solderability being impaired by the products of any capacitor decomposition that might occur. Solder bath temperature 235 ±5 °C Soldering time 2.0 ±0.5 s Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane Evaluation criteria: Visual inspection Wetting of wire surface by new solder ≥90%, free-flowing solder 1.2 Resistance to soldering heat Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A. Conditions: Series Solder bath temperature Soldering time MKT boxed (except 2.5 × 6.5 × 7.2 mm) 260 ±5 °C coated uncoated (lead spacing > 10 mm) MFP MKP (lead spacing > 7.5 mm) MKT boxed (case 2.5 × 6.5 × 7.2 mm) MKP (lead spacing ≤ 7.5 mm) MKT uncoated (lead spacing ≤ 10 mm) insulated (B32559) Please read Cautions and warnings and Important notes at the end of this document. Page 8 of 18 10 ±1 s 5 ±1 s <4s recommended soldering profile for MKT uncoated (lead spacing ≤ 10 mm) and insulated (B32559) B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane Shield Heat-absorbing board, (1.5 ±0.5) mm thick, between capacitor body and liquid solder Evaluation criteria: Visual inspection ∆C/C0 tan δ Please read Cautions and warnings and Important notes at the end of this document. No visible damage 2% for MKT/MKP/MFP 5% for EMI suppression capacitors As specified in sectional specification Page 9 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC 1.3 General notes on soldering Permissible heat exposure loads on film capacitors are primarily characterized by the upper category temperature Tmax. Long exposure to temperatures above this type-related temperature limit can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical characteristics. For short exposures (as in practical soldering processes) the heat load (and thus the possible effects on a capacitor) will also depend on other factors like: Pre-heating temperature and time Forced cooling immediately after soldering Terminal characteristics: diameter, length, thermal resistance, special configurations (e.g. crimping) Height of capacitor above solder bath Shadowing by neighboring components Additional heating due to heat dissipation by neighboring components Use of solder-resist coatings The overheating associated with some of these factors can usually be reduced by suitable countermeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced cooling process may possibly have to be included. EPCOS recommendations As a reference, the recommended wave soldering profile for our film capacitors is as follows: Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Body remperature should follow the description below: MKP capacitor During pre-heating: Tp ≤ 110 °C During soldering: Ts ≤ 120 °C, ts ≤ 45 s MKT capacitor During pre-heating: Tp ≤ 125 °C During soldering: Ts ≤ 160 °C, ts ≤ 45 s When SMD components are used together with leaded ones, the film capacitors should not pass into the SMD adhesive curing oven. The leaded components should be assembled after the SMD curing step. Leaded film capacitors are not suitable for reflow soldering. For uncoated MKT capacitors with lead spacings ≤10 mm (B32560/B32561) the following measures are recommended: pre-heating to not more than 110 °C in the preheater phase rapid cooling after soldering Please refer to EPCOS Film Capacitor Data Book in case more details are needed. Please read Cautions and warnings and Important notes at the end of this document. Page 11 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Cautions and warnings Do not exceed the upper category temperature (UCT). Do not apply any mechanical stress to the capacitor terminals. Avoid any compressive, tensile or flexural stress. Do not move the capacitor after it has been soldered to the PC board. Do not pick up the PC board by the soldered capacitor. Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified lead spacing. Do not exceed the specified time or temperature limits during soldering. Avoid external energy inputs, such as fire or electricity. Avoid overload of the capacitors. The table below summarizes the safety instructions that must always be observed. A detailed description can be found in the relevant sections of the chapters "General technical information" and "Mounting guidelines". Topic Storage conditions Flammability Resistance to vibration Safety information Reference chapter "General technical information" Make sure that capacitors are stored within the 4.5 specified range of time, temperature and humidity "Storage conditions" conditions. Avoid external energy, such as fire or electricity 5.3 (passive flammability), avoid overload of the "Flammability" capacitors (active flammability) and consider the flammability of materials. Do not exceed the tested ability to withstand 5.2 vibration. The capacitors are tested to "Resistance to vibration" IEC 60068-2-6. EPCOS offers film capacitors specially designed for operation under more severe vibration regimes such as those found in automotive applications. Consult our catalog "Film Capacitors for Automotive Electronics". Please read Cautions and warnings and Important notes at the end of this document. Page 12 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Topic Safety information Soldering Do not exceed the specified time or temperature limits during soldering. Cleaning Use only suitable solvents for cleaning capacitors. Embedding of When embedding finished circuit assemblies in capacitors in plastic resins, chemical and thermal influences finished assemblies must be taken into account. Caution: Consult us first, if you also wish to embed other uncoated component types! Reference chapter "Mounting guidelines" 1 "Soldering" 2 "Cleaning" 3 "Embedding of capacitors in finished assemblies" Display of ordering codes for EPCOS products The ordering code for one and the same product can be represented differently in data sheets, data books, other publications and the website of EPCOS, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes. Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Symbols and terms Symbol α αC A βC C CR ∆C ∆C/C ∆C/CR dt ∆t ∆T ∆tan δ ∆V dV/dt ∆V/∆t E ESL ESR f f1 f2 fr FD FT i IC English Heat transfer coefficient Temperature coefficient of capacitance Capacitor surface area Humidity coefficient of capacitance Capacitance Rated capacitance Absolute capacitance change Relative capacitance change (relative deviation of actual value) Capacitance tolerance (relative deviation from rated capacitance) Time differential Time interval Absolute temperature change (self-heating) Absolute change of dissipation factor Absolute voltage change Time differential of voltage function (rate of voltage rise) Voltage change per time interval Activation energy for diffusion Self-inductance Equivalent series resistance Frequency Frequency limit for reducing permissible AC voltage due to thermal limits German Wärmeübergangszahl Temperaturkoeffizient der Kapazität Kondensatoroberfläche Feuchtekoeffizient der Kapazität Kapazität Nennkapazität Absolute Kapazitätsänderung Relative Kapazitätsänderung (relative Abweichung vom Ist-Wert) Kapazitätstoleranz (relative Abweichung vom Nennwert) Differentielle Zeit Zeitintervall Absolute Temperaturänderung (Selbsterwärmung) Absolute Änderung des Verlustfaktors Absolute Spannungsänderung Differentielle Spannungsänderung (Spannungsflankensteilheit) Spannungsänderung pro Zeitintervall Aktivierungsenergie zur Diffusion Eigeninduktivität Ersatz-Serienwiderstand Frequenz Grenzfrequenz für thermisch bedingte Reduzierung der zulässigen Wechselspannung Frequency limit for reducing permissible Grenzfrequenz für strombedingte AC voltage due to current limit Reduzierung der zulässigen Wechselspannung Resonant frequency Resonanzfrequenz Thermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur Diffusion Derating factor Deratingfaktor Current (peak) Stromspitze Category current (max. continuous Kategoriestrom (max. Dauerstrom) current) Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Symbol IRMS iz k0 LS λ λ0 λtest Pdiss Pgen Q ρ R R Ri Rins RP RS S t T τ tan δ tan δD tan δP tan δS TA Tmax Tmin tOL Top TR Tref tSL English (Sinusoidal) alternating current, root-mean-square value Capacitance drift Pulse characteristic Series inductance Failure rate Constant failure rate during useful service life Failure rate, determined by tests Dissipated power Generated power Heat energy Density of water vapor in air Universal molar constant for gases Ohmic resistance of discharge circuit Internal resistance Insulation resistance Parallel resistance Series resistance severity (humidity test) Time Temperature Time constant Dissipation factor Dielectric component of dissipation factor Parallel component of dissipation factor Series component of dissipation factor Temperature of the air surrounding the component Upper category temperature Lower category temperature Operating life at operating temperature and voltage Operating temperature Rated temperature Reference temperature Reference service life Please read Cautions and warnings and Important notes at the end of this document. German (Sinusförmiger) Wechselstrom Inkonstanz der Kapazität Impulskennwert Serieninduktivität Ausfallrate Konstante Ausfallrate in der Nutzungsphase Experimentell ermittelte Ausfallrate Abgegebene Verlustleistung Erzeugte Verlustleistung Wärmeenergie Dichte von Wasserdampf in Luft Allg. Molarkonstante für Gas Ohmscher Widerstand des Entladekreises Innenwiderstand Isolationswiderstand Parallelwiderstand Serienwiderstand Schärfegrad (Feuchtetest) Zeit Temperatur Zeitkonstante Verlustfaktor Dielektrischer Anteil des Verlustfaktors Parallelanteil des Verlfustfaktors Serienanteil des Verlustfaktors Temperatur der Luft, die das Bauteil umgibt Obere Kategorietemperatur Untere Kategorietemperatur Betriebszeit bei Betriebstemperatur und -spannung Beriebstemperatur Nenntemperatur Referenztemperatur Referenz-Lebensdauer Page 15 of 18 B32932 ... B32936 AC applications (heavy duty series) / 305 V AC Symbol VAC VC VC,RMS English AC voltage Category voltage Category AC voltage VCD Vch VDC VFB Vi Vo Vop Vp Vpp VR Corona-discharge onset voltage Charging voltage DC voltage Fly-back capacitor voltage Input voltage Output voltage Operating voltage Peak pulse voltage Peak-to-peak voltage Impedance Rated voltage Amplitude of rated AC voltage R VRMS German Wechselspannung Kategoriespannung (Sinusförmige) Kategorie-Wechselspannung Teilentlade-Einsatzspannung Ladespannung Gleichspannung Spannung (Flyback) Eingangsspannung Ausgangssspannung Betriebsspannung Impuls-Spitzenspannung Spannungshub Nennspannung Amplitude der Nenn-Wechselspannung VSC Vsn (Sinusoidal) alternating voltage, root-mean-square value S-correction voltage Snubber capacitor voltage Z Impedance Spannung bei Anwendung "S-correction" Spannung bei Anwendung "Beschaltung" Scheinwiderstand Lead spacing Rastermaß Please read Cautions and warnings and Important notes at the end of this document. (Sinusförmige) Wechselspannung Page 16 of 18 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). Page 17 of 18 Important notes 7. The trade names EPCOS, Alu-X, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 18 of 18