Preliminary Manual Evaluation Kit User’s Manual Digital Variable Gain Amplifier(DVGA) BVA 303/305/518 BeRex ●website: www.berex.com ●email: [email protected] 1 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual Table of contents Introduction ……………………………………………………………...………………………………………………….…………….….. 3 Applications Support ………………………………………...……………………………………………………………….….……. 3 Evaluation Kit Contents and Requirements ……………………………………………………………………….……… 3 Kit Contents ………………………………………………………………...…….…….………………………………………………...…. 3 Software Requirements ……………………………………………………………..…………………………………………….……… 3 Hardware Requirements………………………………………………………………………………...……………………...………… 4 MCM BVA303/305/518 Evaluation Board Assembly ……………………………………………...…………..… 5 Overview ………………………………………………………………………………………………...…………………………………... 5 MCM BVA303/305 Evaluation Board Outline showing functional overview ...…………………………………………………. 6 DVGA Interface Board V1.0 Hardware Operation ……………………….………………………………………………………...… 7 MCM BVA518 Evaluation Board Outline showing functional overview ...…………………………………………………. 8 DVGA Interface Board V3.0 Hardware Operation ……………………….………………………………………………………...… 9 How to set up PUP …………………………………………... ……………………….………………………………………………………….. 10 USB Interface Board ………………………………………………………………….…………………………………………….…. 11 USB Interface Board Overview ………………………………………………………………………………………………………… 11 Connection of the USB Interface Board to the Evaluation Board …………………………..…………………………………… 11 USB Driver Installation for windows 8 or 7…………………………………….……………………………………………………… 12 USB Driver Installation for windows XP…………………………………….……………………………………………………… 13 EVK Software Installation ………………………………………………………………………………………….……………..… 16 Using the Application Software Graphical User Interface ………………………………………….…….... 19 Evaluation Board Overview….…………………………………………………….……………………………………………….. 22 Tips for Direct control Serial mode …..……………………………………………………………………………………... 23 Technical Resources …..………………………………………………………………………………………………………………... 24 BeRex ●website: www.berex.com ●email: [email protected] 2 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual Introduction The BVA303/305/518 is a gain amplifier with enhanced 6-bit RF Digital Step Attenuator(DVGA) designed for use in 3G/4G wireless infrastructure and other high performance RF applications. An integrated digital control interface supports both serial and parallel programming of the attenuation, including the capability to program an initial attenuation state at power-up. Covering a 31.5 dB attenuation range in 0.5 dB steps, it maintains high linearity and low power consumption from 30~40MHz through 4 GHz. BVA303/305/518 also features an external negative supply option, and is offered in a 24-lead 4x4 mm QFN package. The BVA303/305/518 Evaluation Kit (EVK) includes the application software and hardware required to control and evaluate the functionality of the DVGA using a PC running the Windows operating system to control the USB interface board Application support For any technical inquiries regarding the evaluation kit or software, please visit applications support at www.Berex.com (fastest response) or call (82)-2-568-2754. Evaluation Kit Contents and Requirements Kit Contents The BVA303/305/518 Evaluation Kit (EVK) includes all of the specific software and hardware required to evaluate the DVGA. Included in the EVK are: Quantity Description 1 BVA303/305/518 Evaluation RF Board Assembly 1 USB Interface Board Assembly 1 USB 2.0 Type A to Type B Mini Cable Software Requirements The application software will need to be installed on a computer with the following minimum requirements: PC compatible with Windows™ XP, Vista, 7, or 8 Mouse USB port HTML browser with internet access Administrative privileges BeRex ●website: www.berex.com ●email: [email protected] 3 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual Hardware Requirements In order to evaluate the DVGA(Digital Variable Gain Amplifier) performance of the evaluation board, the following equipment is required: DC power supplies and DC cables Signal Generator Spectrum Analyzer Vector network analyzer CAUTION: The BVA303/305/518 DVGA EVK contains components that might be damaged by exposure to voltages in excess of the specified voltage, including voltages produced by electrostatic discharges. Handle the board in accordance with procedures for handling static-sensitive components. Avoid applying excessive voltages to the power supply terminals or signal inputs or outputs. BeRex ●website: www.berex.com ●email: [email protected] 4 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual MCM BVA303/305/518 Evaluation Board Assembly Preliminary Manual Overview The Evaluation Board is assembled with a BVA303/305/518 DVGA, SP2T mechanical switch (P/S), Parallel Programming switches (D1~D6,LE), several headers, and SMA connectors. The P/S switch is used for Parallel or Serial mode selection. The D1~D6,LE switches are used for setting the control bits in Direct Parallel programming mode. Figure 1. MCM BVA303/305/518 Evaluation Board Assembly < BVA303/305 > BeRex ●website: www.berex.com < BVA518 > ●email: [email protected] 5 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Figure 2. MCM BVA303/305 Evaluation Board Outline Showing Functional Overview VSS Jumper to GND Preliminary Manual VDD and VDD_DIG Jumper Together Port of Direct connect to LE/CLK/DATA 1. Data 2. LE 3. CLK 4. GND Mini USB Connector port Parallel/Serial Mode Selection 1. Direction Left(←) is Parellel/Latched Parallel 2. Direction Right(→) is Serial 1. 2. 3. 4. 1. 2. 3. 4. Programming Switches(LE,D1~D6) Power supply Connector 1. 2. 3. 4. VDD(3V) VDD_DIG(3V) GND GND Set for PUP “High” “High” in Direct Parallel Mode Set for PUP “Low” "Middle"Set for Latched Parallel/ Serial Mode, Using GUI on PC Power-up Selector Jumper 1. PUP1:High, PUP2:High – 31.5dB 2. PUP1:High, PUP2:Low – 16dB 3. PUP1: Low, PUP2:High – 8dB “Low” in Direct Parallel Mode 4. PUP1: Low, PUP2:Low – 0dB (refer to datasheet's table 5) RF In(DSA Input) RF out(Amp output) < BVA303/305 RF & Interface(V1.0) Evaluation Board> BeRex ●website: www.berex.com ●email: [email protected] 6 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual DVGA Interface Board V1.0 Hardware Operation (BVA303/305 Evaluation Board Realease) 1. Verify that all DC power supplies are turned off before proceeding 2. Connect the jumper on JP1, JP2 Preliminary Manual 3. Set jumpers of PUP1 (J7) and PUP2 (J8) to be “HIGH” at upper position and “LOW” at down position 4. Position the P/S switch to Parallel or Serial mode (Left:Parallel & Latched Parallel, Right:Serial) 5. Set the D1~D6 and LE mechanical programming switches on board to support Direct Parallel, Latched Parallel, or Serial mode a. Serial or Latched Parallel mode(using GUI application software on PC) - Place D1~D6 and LE at the middle position to support Latched Parallel and Serial modes with GUI application software and proper position of P/S switch b. In Direct Parallel mode(Using SP3T switch on Interface board without PC) - D1~D6 can be set to “HIGH” or “LOW” to manually program the attenuation state while LE is connected to “HIGH” without using the Mini USB Interface and GUI application software Table 1. SP3T Switch Descriptions for parallel mode D1 0.5dB D2 1dB D3 2dB D4 4dB D5 8dB D6 16dB LE Latch enable 6. Provide external power supply to the J4 connector (refer to the Operating Ranges table in the datasheet for the voltage range) a. VDD is the positive power supply with 3.0V typical b. VDD_DIG is the positive power supply for control signals with 1.8V typical, and it can be connected to VDD with jumper on JP1 to simplify the test set-up c. VSS is the external negative power supply with –3.3V typical. To simplify the test set-up, it can also be shorted to GND with jumper on JP2 to enable using the internal negative voltage generator Remark : In order to evaluate the DVGA of the evaluation board on parallel or serial mode, You should connect the USB cable to a PC. And then to supply an External power VDD or VDD_DIG to the evaluation board. BeRex ●website: www.berex.com ●email: [email protected] 7 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Figure 3. MCM 518 Evaluation Board Outline Showing Functional Overview VSS Jumper to GND VDD and VDD_DIG Jumper Together Preliminary Manual Option Switch for using Serial or Parallel select Mini USB Connector port Parallel/Serial Mode Selection 1. Direction high(↑) is Parellel/Latched Parallel 2. Direction Low(↓) is Serial Programming Switches(D1~D6,LE) 1. 2. 3. 4. 1. 2. 3. 4. Port of Direct connect to LE/CLK/DATA 1. Data 2. LE 3. CLK 4. GND Power supply Connector 1. 2. 3. 4. VDD(5V) VDD_DIG(5V) GND GND “High” in Direct Parallel Mode Set for PUP “High” "Middle"Set for Latched Parallel/ Serial Mode, Using GUI on PC Set for PUP “Low” Power-up Selector Jumper “Low” in Direct Parallel Mode 1. PUP1:High, PUP2:High – 31.5dB 2. PUP1:High, PUP2:Low – 16dB 3. PUP1: Low, PUP2:High – 8dB 4. PUP1: Low, PUP2:Low – 0dB (refer to datasheet's table 5) RF In(DSA Input) RF out(Amp output) < BVA518 RF & Interface(V3.0) Evaluation Board> BeRex ●website: www.berex.com ●email: [email protected] 8 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual DVGA Interface Board V3.0 Hardware Operation (BVA518 Evaluation Board Realease) 1. Verify that all DC power supplies are turned off before proceeding 2. Connect the jumper on JP1, JP2 Preliminary Manual 3. Set jumpers of PUP1 (J7) and PUP2 (J8) to be “HIGH” at upper position and “LOW” at down position 4. Position the P/S switch to Parallel or Serial mode (Upper:Parallel & Latched Parallel, Down:Serial) 5. Set the D1~D6 and LE mechanical programming switches on board to support Direct Parallel, Latched Parallel, or Serial mode a. Serial or Latched Parallel mode(using GUI application software on PC) - All of pin on DIP1(option Switch) set to high <Figure 4. DIP1 Switch setting in case of Serial or Latched Parallel> - Place D1~D6 and LE at the middle position to support Latched Parallel and Serial modes with GUI application software and proper position of P/S switch Table 1. SP3T Switch Descriptions for Parallel mode b. In Direct Parallel mode(Using SP3T switch on Interface board without PC) D1 0.5dB - 1pin on DIP1(option Switch) set to high and others pin are setting to down D2 1dB D3 2dB D4 4dB - D1~D6 can be set to “HIGH” or “LOW” to manually program the attenuation state while LE is D5 8dB connected to “HIGH” without using the Mini USB Interface and GUI application software D6 16dB LE Latch enable <Figure 5. DIP1 Switch setting in case of Direct Parallel> 6. Provide external power supply to the J4 connector (refer to the Operating Ranges table in the datasheet for the voltage range) a. VDD is the positive power supply with 3.0V typical b. VDD_DIG is the positive power supply for control signals with 1.8V typical, and it can be connected to VDD with jumper on JP1 to simplify the test set-up c. VSS is the external negative power supply with –3.3V typical. To simplify the test set-up, it can also be shorted to GND with jumper on JP2 to enable using the internal negative voltage generator Remark : In order to evaluate the DVGA of the evaluation board on parallel or serial mode, You should connect the USB cable to a PC. And then to supply an External power VDD or VDD_DIG to the evaluation board. BeRex ●website: www.berex.com ●email: [email protected] 9 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual HOW to set the PUP 1. Position the Parallel/Serial switch to Parallel mode 2. Set the “LE” Switch to “Low” Preliminary Manual 3. Set jumpers of PUP1 (J7) and PUP2 (J8) to be “HIGH” at upper position and “LOW” at down position as you need (refer to Table 2) Table 2. Parallel PUP Truth Table P/S 0 0 0 0 LE 0 0 0 0 PUP2 0 1 0 1 PUP1 0 0 1 1 Attenuation state Reference Loss 8 dB 16 dB 31.5 dB 0 1 X X Defined by C0.5-C16 4. Provide external power supply (VDD) BeRex ●website: www.berex.com ●email: [email protected] 10 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual USB Interface Board Preliminary Manual USB Interface Board Overview Figure 6. USB interface board A USB interface board (Figure 3) is included in the Evaluation Kit. This board allows the user to send SPI commands to the device under test by using a PC running the Windows™ operating system. To install the software, extract the zip file to a temporary directory and follow the installation procedure included. < DVGA Interface(V1.0) Evaluation Board> < DVGA Interface(V3.0) Evaluation Board> Connection of the USB Interface Board to the Evaluation Board Figure 7. DVGA USB Interface Board The Evaluation Board and the USB interface board contain the 15 pin D-sub connector. This feature allows the USB interface board (socket) to connect directly to the Evaluation Board (pin) on the front-side as shown in Figure 4. Connected to the BVA303/305/518 Evaluation Board for Latched Parallel and Serial Programming USB Driver Installation The latest USB interface board drivers are available via Microsoft Windows update. Internet connectivity is required to download the drivers. Connect the USB interface board to the PC and select the Windows Update option to obtain and install the drivers. If the USB board drivers are not installed, it will not be possible to run the program correctly. Figure 8. USB Driver Installation A USB interface board (Figure 5) is included in the Evaluation Kit. This software is available directly from FTDI’s website at http://www.ftdichip.com/Drivers/VCP.htm Recommend : For Windows XP, USB Serial Converter & Port Driver recommend 2.10.00(x86:32-bit, x64:64bit) WHQL Certified file. BeRex ●website: www.berex.com ●email: [email protected] 11 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual USB Driver Installation for Windows Driver 8 or 7 Preliminary Manual Figure 10(a-b). USB Serial Converter FTDI Driver Installation For Windows 8 and 7, drivers will be installed automatically when your computer is connected to the Internet. Alternatively, you may install the drivers from the file web site download (http://www.ftdichip.com/Drivers/VCP.htm) Connect the USB Serial converter to an available USB port, and the “Found New Hardware Wizard” will guide you through the installation process. When prompted to connect to Windows Updates to search for drivers, select “No, not at this time”, and follow the instructions for installing from the file downloaded Once the drivers are successfully installed, the USB Serial converter will show up in the Windows Device Manager: Under “Ports (COM & LPT)”: labeled as “USB Serial Port (COMx)”, and under “Universal Serial Bus controllers”: labeled as “USB Serial Converter” (Figure 10-b). IMPORTANT NOTES: If it’s the first time you install the driver for CommFront’s USB to Serial device, you will need to install the driver twice. One is for “USB Serial Converter”, and the other one is for “USB Serial Port”. nd DO NOT close the 2 “Found New Hardware Wizard” window while installing the driver. Upon completion of driver installations, remember to check the Windows Device Manager to make sure that the drivers are installed properly (Figure 10-a). If the drivers are not installed correctly, there will be a yellow exclamation icon displayed under the “Ports (COM & LPT)” or “USB Serial Bus controllers”, right-click on the yellow exclamation icon and select “Update driver”. Then search for the driver BeRex ●website: www.berex.com ●email: [email protected] 12 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Preliminary Manual Evaluation Kit User’s manual USB Driver Installation for Windows Figure 11(a-d). USB Serial Converter XP Driver Installation for windows XP connect the USB Serial converter to an available USB port, the “Found New Hardware Wizard” window will pop up. Select “No, not this time” and click on the “Next” button to continue (Figure 11-a) Select “Install from a list or specific location (Advanced)” to install the driver from files And Click “Next“button Select “Search for the best driver in these locations” and check the box of “Include this location in the search”. Then Click on the “Browse” button And browse to the location you unzipped the USB drivers to in the previous step http://www.ftdichip.com/Drivers/VCP.htm (2.10.00 WHQL Certified file) Windows will install the first driver. (Maybe select FTDIBUS.INF) BeRex ●website: www.berex.com ●email: [email protected] 13 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual The wizard will search for the driver and then tell you that a “ USB Serial Converter” was found. Click finish Figure 11(e-g). USB Serial Converter Driver Installation for windows XP After finish the USB Serial Converter Driver. You can find the new hardware wizard pop up window of USB Serial Port.(Figure 11-f) Select “Install from a list or specific location (Advanced)” to install the driver from CD And Click “Next“button Select “Search for the best driver in these locations” and check the box of “Include this location in the search”. Then Click on the “Browse” button And browse to the location you unzipped the USB drivers to in the previous step BeRex ●website: www.berex.com ●email: [email protected] 14 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual If Windows gives any warnings, click OK to proceed. (Select Directory to the location you unzipped the USB drivers to in the previous step) Figure 11(h-l). USB Serial Converter Driver Installation for windows XP Windows will install the first driver. (Maybe select FTDIPORT.INF) Click NEXT when the installation is complete. BeRex ●website: www.berex.com ●email: [email protected] 15 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual EVK Software Installation In order to evaluate the BVA303/305/518 performance, the Application Software has to be installed on your computer. The USB interface and DVGA application software is compatible with computers running Windows™ XP, Vista, 7, or 8. This software is available directly from Berex’s website at http://www.berex.com/Products/Documents/Installers/DVGA%20Evaluation%20Software% 20Installer%20R2.3.1.zip To install the DVGA evaluation software, unzip the archive and execute the “setup.exe.” Figures 12(a-c). Application Software Installation Procedure After the setup.exe file has been executed, a welcome screen will appear. It is strongly recommended that all programs be closed prior to running the install program. Click the “Next>” button to proceed BeRex ●website: www.berex.com ●email: [email protected] 16 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Preliminary Manual Evaluation Kit User’s manual For most users the default install location for the program files is sufficient. If a different location is desired, the install program can be directed to place the program files in an alternate location. The software is installed for “Everyone” by default. Once the desired location is selected click “Next >.” Figures 12(d-f). Application Software Installation Procedure The Confirm Installation is ready to install the DVGA evaluation software on your computer, then click “Next>” to proceed with the software installation. As the software files are installed, a progress indicator will be displayed. On slower computers, installation of the software may proceed for a few moments. BeRex ●website: www.berex.com ●email: [email protected] 17 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual Once the evaluation software is installed, click “Close” to exit. Figures 12(g). Application Software Installation Procedure A new Start Menu item under Peregrine Semiconductor will appear in the start menu of your computer. Select “DVGA Evaluation Software” to launch the GUI. BeRex ●website: www.berex.com ●email: [email protected] 18 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Using the Application Software Graphical User Interface Preliminary Manual Figure 9 displays the DVGA application software graphical user interface (GUI), which has the USB interface board plugged into the computer. If the USB interface board is not connected when the application software is launched, the message “No interface board connected! Please connect USB -SPI Interface #101-0695.” will appear at the bottom of the screen. In the upper left corner, under the Peregrine Logo there is a drop down menu item to select the part for evaluation and the part description is right below the part number box. Figure 13. DVGA Application Software Graphical User Interface (GUI) BeRex ●website: www.berex.com ●email: [email protected] 19 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual The DVGA application software GUI supports Latched Parallel and Serial modes, and shows the control bit waveform at the right side of the GUI when the mode is selected. The Send button changes functionality based on the control interface mode. Send Latch in Latched Parallel mode and Send Signal in Serial mode is provided to resend the programming bits to the device at the same attenuation state. Figure 14. Latched Parallel or Serial Mode Continuous Pattern Loop can be selected to automatically step through each of the attenuation states. The Attenuation Value box displays the attenuation value the DVGA is currently programmed. The user can enter the desired attenuation value followed by the “Enter” key to program the DVGA. BeRex ●website: www.berex.com ●email: [email protected] 20 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Preliminary Manual The center of the GUI is the attenuation slide bar that allows the user to quickly select the desired attenuation. The arrows at the top and bottom can be clicked to increase or decrease attenuation state at the minimum step size. BeRex ●website: www.berex.com ●email: [email protected] 21 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Evaluation Board Overview Preliminary Manual Figure 15. BVA303/305/518 Evaluation Board Schematic BeRex ●website: www.berex.com ●email: [email protected] 22 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Tips for Direct control Serial mode Preliminary Manual DVGA interface board provides an environmental to test the serial interface by mcu you own. Figures 16. DVGA Interface board connect to Serial interface & Direct control You can connect between BVAxxx and MCU you own (Figure 16) 1. 2. 3. 4. And then If MCU send the signal CLK,DATA,LE, you will be able to control the BVAxxx like DVGA Interface board using GUI BeRex ●website: www.berex.com ●email: [email protected] DATA LE CLK GND 23 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2 BVA303/305/518 Evaluation Kit User’s manual Technical Resources Preliminary Manual Additional technical resources are available for download in the Products section at www.berex.com. These include the Product Specification datasheet, Evaluation Kit schematic and Bill of Materials, Material Declaration form, and PC-compatible software file. Trademarks are subject to trademark claims. BeRex ●website: www.berex.com ●email: [email protected] 24 Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2015 BeRex Rev. 0.2