0.4 mm Pitch Ultra-low Profile FPC Connector FF18N Series 【Upper and lower Type】 DDK Ltd. OUTLINE FF18N series is a connector with a cable lock mechanism to provide positive retention of the FPC. This LIF connector has a both upper and lower contacts to interface with the FPC at a 0.4mm pitch. The ultra-low profile connector has a 0.66mm height, making it one of the smallest board mounted FPC ZIF connectors on the market. FEATURE - The FF18N’s dual contact design allows for design versatility by having both upper and lower contacts. - DDK’s original cam-type back-lock system provides reliable operation and ensures retention from inadvertent upward pulling of the FPC. - The FF18N ZIF connector utilizes a cable lock mechanism to provide positive retention of the FPC. - Back-lock mechanism ensures retention from inadvertent from upward pulling of the FPC. - These ZIF connectors are delivered with the lock lever opened for maximum production efficiency. - Available in pin counts for this low profile connector are 4, 5 and 6 pins. - Contacts utilize a nickel barrier to prevent solder wicking - High-temperature resin for lead free reflow process - FF18N ZIF connectors are delivered in a tape and reel package for automated machine processes. Note : ※ Please do not close the lock lever without inserting the FPC. Since cable lock tabs electrify next contacts, please do not use the cable lock tabs as ground tabs. APPLICATIONS Touch panel, LCD back-light, camera modules, side-key connections and other accessories SPECIFICATIONS Rated Voltage 50V AC(r.m.s.) Rated Current 0.4A / Contact Dielectric Withstand Voltage 200V AC(r.m.s.) / 1 minute Insulation Resistance 100 M Ω min. at 500V DC Contact Resistance 50m Ω max. Durability 10 Cycles Operating Temperature Range −55℃〜+ 85℃ MATERIAL/FINISH Item 150525 RoHS Compliant Compliant Material / Finish Contact Copper Alloy /Au(Flash) over Ni Plating Housing LCP Resin (UL94V-0)/ Ivory Lock Lever PPS Resin(UL94V-0)/ Black ◎ Specifications and/or dimensions in this catalog are subject to change without notice. Please varify the latest specifications with our drawings. http://www.ddknet.co.jp Unit:mm FF18N Series ○ Ultra-low profile connectors【Upper and lower Type】 FF18N- □□ A- R 11A-3H ② ③ ④ ⑤⑥ ⑦ ⑧ ① Series FF18N ③ Contact Position A:Upper and lower、 FPC Thickness:0.12±0.03mm ② Number of Contact See Table-1 ④ Contact Style R:Right Angle ⑥ A Contact Plating 1:Au (Flash) over Ni Plataing ⑤ Contact Pich 1:0.40mm A:Standard Type 3H : Halogen Free 3.50 a b 3.15 Dimensions Recommended P.C.B Pattern lay-out and metal mask Dimension 3.15 Section a-a 3.05 No.1 contact 0.40 0.20 No.1 Contact 0.40±0.07 0.15 X 0.50 Section b-b Applicable Recommended P.C.B Pattern FPC lay-out Dimension and metal mask dimension 品名構成 (P/N Code) 0.47 No.1 contact 0.10±0.03 0.40 0.45 C X D 0.15 X 0.45 0.23±0.03 0.04 X Section a-a FF18N- 4A-R11A-3H FF18N- 10A-R11A-3H FF18N - ×× A - R 1 1 A - 3H 1 2 3 4 56 7 8 1 シリーズ名 (Series Name) FF18N:上下両接点タイプ (Upper and lower contact point) 2 芯数 (No. of Contacts) 表-1参照 (See Table-1) 3 接点形状 (Contact Point Side) A:上下接点,適合FPC厚=0.12±0.03mm 6 コンタクト表面処理 (Contact plating) 1:ニッケル下地金フラッシュめっき (Flash Gold over Nickle Plating) 7 スライダー形状(Slider Form) A:上下接点,適合FPC厚=0.12±0.03mm (Upper and lower,FPC t=0.12±0.03mm) 0.27±0.30 0.40±0.03 0.70±0.07 4 10 B C 3.50 2.65 2.10 5.90 5.05 4.50 仕様 (Specifications) 1:定格電圧 50V (実効値) Voltage Rating 50V AC. D±0.03 E±0.05 1.20 注記 (Note) 0.12±0.30 2.60 1.テールのコプラナリティは0.08以下のこと。 3.60 5.00 Tail Co-Planarity shall be 0.08mm MAX. 3.FPCをコネクタに嵌合すると、ケーブルロックタブは両端の端子と導通します。 ケーブルロックタブの実装ランドをグランドに落とさないでください。 If FPC is mated to connector, Cable Lock Tab conducts with contact of both ends. Please do not connect mounting land of Cable Lock Tab to ground. 2 5:接触抵抗 10mA (直流) にて50mΩ以下。 Contact Resistance 50mΩ max at 10mA DC. 6:挿抜回数 Durability (Insertion/withdrawal):10回(10 cycles) D for FPC recommended E Applicable dimension 2.FPCを挿入しない状態で、コネクタをロックしないでください。 Please do not lock the slider without an FPC inserted. Durability (Insertion/withdrawal):10回(10 cycles) 4:絶縁抵抗 500V (直流) で測定し100MΩ以上。 Insulation Resistance 100MΩ min at 500V DC. 0.70±0.07 3:耐電圧 200V (実効値) 1分間で異常のないこと。 Dielectric Withstanding Voltage 200V 1 minute at sea level. 4:絶縁抵抗 500V (直流) で測定し100MΩ以上。 Insulation Resistance 100MΩ min at 500V DC. 3:耐電圧 200V (実効値) 1分間で異常のないこと。 Dielectric Withstanding Voltage 200V 1 minute at se 0.27±0.30 2:定格電流 0.4A/コンタクト Current Rating 0.4A/Contact. (Upper and lower, FPC t=0.12±0.03mm) 5:接触抵抗 10mA (直流) にて50mΩ以下。 ◎ Specifications and/or dimensions in this catalog are subject to change without notice. Contact Resistance 50mΩ max at 10mA DC. 4 コンタクトスタイル (Contact Style) Please varify (Right theAnglelatest specifications with our drawings. 6:挿抜回数 R:ライトアングル Type) 5 コンタクトピッチ (Contact pich) http://www.ddknet.co.jp 1: 0.4mm pich R 0 (Contact Style) 0. .204 コンタクトスタイル R:ライトアングル (Right Angle Type) 20 5 コンタクトピッチ (Contact pich) 5 1: 0.4mm pich 1 0. 0 2 R (Contact plating) 0. 6 コンタクト表面処理 1:ニッケル下地金フラッシュめっき R .20 (Flash Gold over Nickle Plating) 0 R 7 スライダー形状(Slider Form) R Section b-b Number of 2:定格電流 0.4A/コンタクト Stiffener Current Rating 0.4A/Contact. 0.07 2 芯数 (No. of Contacts) 表-1参照 (See Table-1) 0.57 Number Recommended P.C.BPart Pattern lay-out and metalContact mask dimension A 1:定格電圧 50V (実効値) Voltage Rating 50V AC. 0.45±0.053 接点形状 (Contact Point Side) Table-1 品名構成 (P/N Code) 仕様 (Specifications) FF18N - ×× A - R 1 1 A - 3H 1 2 3 4 56 7 8 0.20 (0.10) (0.40 min.) 0.30 1.00 0.23±0.03 0.04 X D 1 シリーズ名 (Series Name) FF18N:上下両接点タイプ (Upper and lower contact point) パターン禁止エリア 3.05 1.30 0.24 (FPC position) 0.18 0.40 D 0.12±0.03 (3.35) 0.04 X 2.10±0.05 X C 0.25±0.05 0.45 0.75±0.05 0.15 X C 0.45 0.45 0.45 X a B 0.10±0.03 0.45 b 0.50±0.05 0.45 0.57 (2.50 min.) 0.47 0.30 3.50 a b (3.35) C D±0.07 パターン禁止エリア 2.10±0.05 0.15 AX 0.50 0.50±0.05 0.40 0.12±0.03 1.00 (0.10) (0.40 min.) D (1.39) 0.24 (FPC position) 0.18 X 1.30 1.20 1.40±0.30 B 0.25±0.05 0.04 X 0.66 (0.70 max.) 0.40±0.07 0.45 0.45 a 0.75±0.05 C b No.1 Contact 0.45±0.05 0.85±0.05 D±0.07 ⑧ Material 0.66 (0.70 max.) C Slider Form ⑦ (1.39) ① 4.補強板を付ける場合は長さ2.5mm以上にしてください。 When attaching "supporting tape", the length is 2.5mm or more. FF18N-xxA-R11A-3H G-503918(2/2) Unit:mm FF18N Series 16.40 22.40 ○ Packing Specifications 13.50 User Direction of Feed User Direction of Feed φ80 φ328 φ80 φ328 13.50 16.40 22.40 ■ Reel Dimensions 400mm min. 400mm min. Tailer:30 pockets min. Leader: 15 pockets min. 4000 pockets Empty components pockets Tailer:30 pockets min. sealed with cover tape. Leader: Empty components pockets 15 pockets min. sealed with cover tape. 4000 pockets Empty components pockets sealed with cover tape. Empty components pockets sealed with cover tape. User Direction of Feed User Direction of Feed ■エンボスキャリアテープ寸法図 ■エンボスキャリアテープ寸法図 ■ Emboss Tape Dimensions 8.00 8.00 2.00 2.00 C B 3.40 16.00±0.3 1.75 16.00±0.3 7.50 B B 3.40 (1.84) B C Section C-C (1.84) Section C-C (1.84) 14.25 1.75 7.50 A A (1.84) +0.1 1.50 0 14.25 +0.1 4.00 C C 0 4.00 1.50 Section B-B Section B-B Part Number FF18N- 4A-R11A-3H FF18N- 10A-R11A-3H ■ Quantity:4000pcs. / Reel ◎ Specifications and/or dimensions in this catalog are subject to change without notice. Please varify the latest specifications with our drawings. http://www.ddknet.co.jp 3 Number of Contact A 4 3.80 10 6.20 FF18N Series Umit:mm ○ Operating Instruction and Cautions 1.Connector mounting Instruction Lock lever is opened, delivered. Connectors are delivered with a lock lever opened. picture ① You do not have to operate the lock lever before inserting FPC. (picture ① ) Please do not re-flow with the lock lever closed condtion. Please close the lock-lever with inserting FPC, otherwise the contact gap become narrower and FPC insertion force will rise. (picture ② ) Please do not load (0.5N×pin Min.) from the top of the lock lever. (figure ① ) And please do not load (0.5N×pin Min) toward the opposite direction of the lock lever, (figure ② ) otherwise the lock lever may be broken or contacts may be deformed. picture ② figure ② figure ① While FPC mated with connector, cable lock tabs conduct to both ends of contacts. Please do not ground the cable lock tab pad on the mounting board.(figure: ③) Please do NOT ground Cable Lock Tab ▼ Cable Lock Tab pad Contact ▼ ▼ ▼ ▼ Contact pad ▼ ▼ ▼ ▼ ▼ ▼ Connector ▼ P.C.B (mounting side) FPC figure ③ ◎ Specifications and/or dimensions in this catalog are subject to change without notice. Please varify the latest specifications with our drawings. http://www.ddknet.co.jp 4 FF18N Series Umit:mm ○ Operating Instruction and Cautions 2.FPC Insertion Please insert FPC to the pattern side up.(picture ③ ) when using upper contacts. Please insert FPC to the stiffener side up(picture ④ ) when using lower contacts. Please insert FPC straight to the connector. Due to the semi-reteining mechanism, some insertion force is necessary when inserting FPC. Please make sure whether FPC is inserted fully. Pattern side Stiffener side OK OK picture ④ picture ③ 3.Correct FPC Insertion Position As illustrated (picture ⑤ ), you can check short insertion(picture ⑥ ) and diagonal insertion(picture ⑦ ) by checking the position of connector housing and FPC positioning edge. If the FPC positioning edge is exposed from the connector housing, it may be short insertion or diagonal insertion. Please re-insert FPC fully. FPC Edge OK NG NG picture ⑤ picture ⑥ picture ⑦ Correct insertion Short insertion Diagonal insertion ◎ Specifications and/or dimensions in this catalog are subject to change without notice. Please varify the latest specifications with our drawings. http://www.ddknet.co.jp 5 FF18N Series Umit:mm ○ Operating Instruction and Cautions 4.Closing Lock Lever Please rotate down the lock lever until firmly closed. (picture ⑧ ) Please do not load excessive force(3N Min) on the housing(picture ⑨ ) and please do not close the lock lever by tip of a nail.(picture ⑩ ) It may cause breakage of the lock lever. OK picture ⑧ NG NG Picture ⑩ picture ⑨ 5.Removing FPC Please lift the lock lever like flipping up in the direction of arrow.(picture ⑪ ) Please do not load excessive force (0.5N×pin Min.) on the lock lever.(picture ⑫ ) OK NG 0.5N×pin Min. picture ⑪ picture ⑫ 6.ESD (Electrostatic Discharge) This connector is not taken ESD measure. 7.Disposal of Connector Please dispose the connector as industrial waste. ◎ Specifications and/or dimensions in this catalog are subject to change without notice. Please varify the latest specifications with our drawings. http://www.ddknet.co.jp 6