FF52 series product data PDF

0.3 mm Pitch Ultra-low Profile
FPC Back-lock Connector
FF52 Series 【Upper Contact】
OUTLINE
The FF52 connector series utilizes a cable lock mechanism
to provide positive retention of the FPC. This LIF connector
has a dedicated upper contact to interface with the FPC at a
0.35mm pitch. The ultra-low profile connector has a 0.5mm
height, making it one of the smallest board mounted FPC LIF
connectors on the market.
FEATURES
・DDK’s original cam-type back-lock system provides reliable operation and ensures retention
from inadvertent upward pulling of the FPC.
・The FF52 connector has an ultra-low height of 0.5mm.
・Each individual contact is rated to 0.4A current.
・The FPC is mechanically retained within the FF52 with DDK’s cable-lock design.
・These ZIF connectors are delivered with the lock lever opened for maximum production efficiency.
・Contacts utilize a nickel barrier to prevent solder wicking.
・The housing and lock lever are made of heat-resistant resin making possible lead-free reflow soldering.
・FF52 ZIF connectors are delivered in a tape and reel package for automated machine processes.
Note: ※ Please do not close the lock lever without inserting the FPC.
※ Since the cable lock tabs electrically conductive on both ends, please do not use the cable lock tabs as ground tabs.
APPPLICATIONS
LCD Back-light module, Touch Panel, Accessary module
SPECIFICATIONS
Rated Voltage
50V AC(r.m.s.)
Rated Current
0.2A / Contact
Dielectric Withstand Voltage
200V AC(r.m.s.) /1 minute
Insulation Resistance
50 M Ω min. at 250V DC
Contact Resistance
80m Ω max.
MATERIAL/FINISH
Item
150210
RoHS
Compliant
Compliant
Material / Finish
Contact
Copper Alloy / Au (Flash) over Ni
Housing
LCP Resin(UL94V-0)/ Ivory
Lock Lever
PPS Resin(UL94V-0)/ Black
◎ Specifications and/or dimenssions in this catalogue are subject to change without notice.
Your catalogue checking the latest speifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
Unit:mm
FF52 Series
○ 0.3mm Pitch FPC Connector【Upper Contact】
FF52- □□ A- R 11A-3H
③
④ ⑤ ⑥ ⑦
⑧
① Series
Dimensions
FF52
② Number of Contact
③ Contact Position
Refer to the table 1
A:Upper Contact, Applicable FPC Thickness0.12±0.02mm
④ Contact Style
R:Right Angle
⑤ Contact Tail Length
1:0.30mm & 0.35mm
⑥ Contact Plating
1:Au(Flash) over Ni
⑦ Lock Lever style
A:Standard
⑧ Material
3H:Halogen Free
(1.40)
X
No.1 Contact
0.08±0.03
0.15 X
0.45
Cable lock tab
Cable lock tab
No.2 Contact
No.1 Contact
No.(n) Contact
(0.32)
0.35
Cable lock tab
3.00
2.80
(0.40)
0.30
A±0.10
B
C±0.07
C
0.60
0.45
1.11
②
0.51±0.05
①
Cable lock tab
0.08±0.03
No.(n-1) Contact
0.15 X
0.60
0.30
0.08±0.03
0.15 X
No.n Contact
B
0.3±0.07
D
Recommended P.C.B pattern lay-out
(Shall be located zig zag from No.1 contacts.)
B
0.25±0.02
No.(n-1) Contact
Cable lock tab
0.55±0.05
0.04 Y
No.(n) Contact
C
5±
No.1 Contact
(Applicable for the odd number contacts)
Number of
5.4
0.60
0.30
0.45
Contact
FF52- 8A-R11A-3H NOTE-3 8
0.25±0.02
FF52-15A-R11A-3H
No.2 Contact
0.04 Y
Cable lock tab
FF52-17A-R11A-3H
Connector
0.25±0.02
0.04 Y
location
15
17
B
C
D
E
4.60
3.00
2.10
3.55
3.50
6.70
5.10
4.20
5.65
5.60
5.70
4.80
6.25
6.20
0.45
No.(n) Contact
Cable lock tab
7.30
0.60
0.25±0.02
0.04 Y
4.5
No.(n-1) Contact
(3.00)
0.5±0.02
(0.10)
1.9±0.02
(0.35 min. )
Pattern-prohibited area
No.1 Contact
◎ Specifications and/or dimenssions in this catalogue are subject to change without notice.
Y
Your catalogue checking the latest speifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
(Applicable for the Even number contacts)
5
No.n Contact
A
0.6±0.02
Part Number
2
0.12±0.02
0.0
Edge shape is also applicable
Y
Table−1
R.1
1.37±0.05
1.22±0.10
1.02±0.10
0.82±0.05
0.63±0.10
0.4±0.05
0.33±0.10
0.5±0.02
0.60
0.7±0.05
0.42±0.05
0.05
R.2±
0.05
R.2± .05
5±0
R.1 ±0.05
5
.1
R
.05
5±0
R.1
5
0.04 Y
0.2±0.02
0.1±0.02
(In case plating lead is used)
.0
±0
No.1 Contact
0.3±0.02
5
R.1
0.25±0.02
0.42±0.05
(3.00)
(0.10)
1.90±0.02
(0.35 min.)
Pattern-prohibited area
A±0.05
E±0.05
C±0.02
0.7±0.05
0.93 min.
0.04 Y
No.2 Contact
Cable lock tab
Connector
location
Applicable for FPC recommended dimension
0.45
0.25±0.02
(Overlap)
NOTE-3
0.6±0.02
0.60
0.30
0.45
Stiffener
Unit:mm
FF52 Series
○ Packing Specifications
C TYP.
B Max.
■ Reel Dimensions
C TYP.
B Max.
D TYP.
a
b
USER DIRECTION OF FEED
a
Note-3,6
*****Label Example*****
D TYP.
Ø 80 TYP.
Ø 328 TYP.
b
1.00
DDK Ltd.
TO:
2.00TYP.
Ø2
DDK No.:
13.07.02.01.01
CTN:
P/O No.:
TYP
.
Ø
.
YP
0T
.0
13
USER DIRECTION OF FEED
QTY:
5,000
1.00
DDK Ltd.
P/O No.:
4.00
2.00
PART No.:
FF52-xxA-R11A-3H
4.00
2.00
5,000
0
1.0
3-R
+0.10
Ø 1.50 0.00
8.00
Detail b
Detail b
Direct
ion of
pull
165° ~180°
Directi
on of
pull
165° ~180°
User direction of feed
1.56 TYP.
ENDSection
END
c
Section c-c
Detail a
c
c-c
F Min.
1.56 TYP.
G±0.30
E
A TYP.
F Min.
c
+0.10
Ø 1.50 0.00
QTY:
8.00
.
YP
0T
3.0
Ø1
G±0.30
A TYP.
c
■ Emboss Tape Dimensions
DDK No.:
13.07.02.01.01
CTN:
0
1.0
3-R
TYP
.
1.75
TO:
2.00TYP.
Ø2
1.75
Ø 80 TYP.
Ø 328 TYP.
Note-3,6
*****Label Example*****
E
PART No.:
FF52-xxA-R11A-3H
User direction of feed
400mm Min.
Detail a
START
400mm Min.
5000 pockets
(Trailer): 30 pockets Min.
(Empty components pockets
sealed with cover tape.)
USER DIRECTION OF FEED
5000 pockets
(Trailer): 30 pockets Min.
(Empty components pockets
sealed with cover tape.)
Part Number
FF52- 8A-R11A-3H
USER DIRECTION OF FEED
Number of
Contact
A
8
4.75
FF52-15A-R11A-3H
15
6.85
FF52-17A-R11A-3H
17
7.45
START
(Leader): 15 pockets Min.
(Empty components pockets
sealed with cover tape.)
(Leader): 15 pockets Min.
(Empty components pockets
sealed with cover tape.)
B
C
D
E
F
G
30.4
24.4
21.5
11.5
22.3
24.0
■ Quantity:5,000pcs./Reel
◎ Specifications and/or dimenssions in this catalogue are subject to change without notice.
Your catalogue checking the latest speifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
3
FF52 Series
Unit:mm
○ Operating Instruction and Cautions
Lock lever is opened when delivery.
1.Connector mounting Instruction
・Connectors are delivered with the lock lever opened.
You do not have to operate the lock lever before inserting FPC.
(picture ①)
・Please do not re-flow with the lock lever in the closed condition.
picture ①
・Please do not close the lock lever without inserting FPC.
Otherwise, the contact gap will become narrower and FPC insertion
force will rise.(picture ②)
Lock lever closed
no FPC inserting
picture ②
・Please do not load from the top of the lock lever.(figure ①)
And please do not load toward the opposite direction of the lock lever.(figure ②)
Otherwaise, the lock lever may be broken or contacts may be deformed.
figure ②
figure ①
・Please do not insert finger nail into the entry
as it may damage the connector(figure ③)
figure ③
◎ Specifications and/or dimenssions in this catalogue are subject to change without notice.
Your catalogue checking the latest speifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
4
FF52 Series
Unit:mm
○ Operating Instructions and Cautions
Cable lock tabs conduct to both ends of contacts.
Please do not ground the cable lock tab pad on the mounting board.(figure ④)
Cable Lock Tab
Connector
Contact
Cable Lock Tab pad
Please do NOT ground
FPC
P.C.B
(mounting side)
Cable Lock Tab
Contact pad
Contact
The cable lock tab is connected to
the adjacent contact.
figure ④
◎ Specifications and/or dimenssions in this catalogue are subject to change without notice.
Your catalogue checking the latest speifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
5
FF52 Series
Unit:mm
○ Operating Instruction and Cautions
2.FPC Insertion
・Please insert the FPC with the pattern side up.(correct: picture ③ , wrong:picture ④)
Pattern side
Stiffener side
picture ④
picture ③
・Please insert the FPC straight into the connector.
Due to the semi-retaining mechnism, some insertion force is
necessary when inserting FPC.
FPC insertion is completed when the edges of the FPC are
touching connector frange.(picture ⑤)
FPC edge
3.Correct FPC Insertion Position
・Check line enables a visual verification of the mating position.(figure ⑤).
picture ⑤
It prevents shallow and diagonal insertion.(figure ⑥ , picture ⑥ , ⑦ , ⑧)
Correct FPC Insertion
Check line is cocealed.
Position Check Line
figure ⑤
OK
figure ⑥:Standard insertion
picture ⑥:Standard insertion
Check line is exposed.
Check line is exposed.
NG
NG
picture ⑦:Shallow insertion
picture ⑧:Diagonal insertion
◎ Specifications and/or dimenssions in this catalogue are subject to change without notice.
Your catalogue checking the latest speifications with our drawings would be highly appreciated.
http://www.ddknet.co.jp
6
FF52 Series
Unit:mm
○ Operating Instruction and Cautions
4.Closing Lock Lever
・Please rotate down the lock lever until firmly closed.(picture ⑨ ) Please do not load excessive force on the housing.(picture ⑩ )
picture ⑨
picture ⑩
・Please do not close the lock lever by tip of finger nail.(picture ⑪)
picture ⑪
5.Removing FPC
・Please lift the lock lever by flipping up in the direction of arrow.(picture ⑫ ) Please do not load excessive force on the lock lever.(picture ⑬ )
picture ⑫
picture ⑬
6.ESD(Electrostatic Discharge)
・This connector does not protect the circuit from ESD.
7.Disposal of connector
・Please dispose the connector as industrial waste.
◎ Specifications and/or dimenssions in this catalogue are subject to change without notice.