Specifications

NEXT
FIND IT
Table of Contents
CLICK FOR PDF FILE
CLICK FOR PDF FILE
OVERVIEW –
Inductive Proximity Sensors
CYLINDRICAL
Inductive Proximity Sensors
LIMIT STYLE
Inductive Proximity Sensors
Introduction ........................................4
Operation ............................................5
Introduction/Operation .......................8
Selection Guide, DC styles................12
Selection Guide, AC styles ................14
Product Specifications......................16
Introduction/Operation .....................68
Selection Guide.................................71
Product Specifications......................72
CLICK FOR PDF FILE
CLICK FOR PDF FILE
CLICK FOR PDF FILE
BLOCK STYLE
Inductive Proximity Sensors
RING STYLE
Inductive Proximity Sensors
ACCESSORIES for
Inductive Proximity Sensors
Introduction/Operation .....................80
Selection Guide.................................82
Product Specifications......................84
Introduction/Operation .....................98
Selection Guide...............................100
Product Specifications....................102
Introduction ....................................113
Mounting Brackets .........................114
Cable Assemblies............................116
Switching Units...............................122
Motion Detectors............................128
OTHER INFORMATION
APPENDIX:
IP Codes .........................................132
NEMA requirements .......................133
Cross Reference .............................134
Glossary..........................................135
Conversion Charts ..........................137
INDEX .............................................138
TERMS & CONDITIONS .................141
WARRANTY....................................143
CLICK FOR PDF FILE
All specifications subject to change without notice or obligation
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
3
PREVIOUS
HOME
NEXT
FIND IT
Cylindrical Sensors
8
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
CYLINDRICAL INDUCTIVE
PROXIMITY SENSORS
Altech Cylindrical sensors are available in diameters ranging from
4mm (.16 in.) to 30mm (1.18 in.)
with sensing distances up to 40mm
(1.57 in.). Most models feature nickel plated brass (BN) housing, but
stainless steel (SS) and non-metallic
versions are available. Both flush
mount and non-flush mount sensors
are available. Flush mount versions
are often called shielded or embeddable. Non-flush mount sensors are
also called non-shielded or nonembeddable. Non-flush sensors
have larger sensing distances than
their flush mount counterparts. All
Inductive sensors meet IP67
(NEMA1, 3, 4, 6, 12, 13) protection
levels. Please refer to pages
132-133 of this catalog for more
information.
FLUSH MOUNT
CYLINDRICAL SENSORS
Flush Mounted, sometimes called
embedded or shielded sensors,
have electromagnetic fields concentrated directly in front of the
sensing heads and may be mounted directly into metal mounting
brackets or embedded directly into
metal without causing a false output. Figure 8 also illustrates that on
Cylindrical Flush Mount sensors
there should be at least 1 diameter
of distance between adjacent sensors, and no non-target metal surfaces should be less than 3 times
the sensing distance Sn directly
across from the sensing head. Also,
two directly opposite sensors
mounted in metal should be greater
than 6 times the sensing distance
apart.
HOME
NEXT
FIND IT
Sensing Distances – AC, DC, Cylindrical Style Sensors
Type
Voltage
Flush*
Non-Flush*
L Series - Short Body
DC
1.5 - 10
2 - 15
GL Series - 2 LED
DC
2 - 10
4 - 15
AC, DC
1.5 - 10
2 - 15
Extended Sensing Range
DC
2 - 15
3
High Speed
DC
2
AC, DC
2 - 10
Mini Housing
DC
0.8 - 1.5
Complementary Output
DC
2 - 10
4 - 15
Extended Temperature Range
DC
2 - 10
4 - 15
Weld Immune
AC, DC
2 - 10
4 - 15
Analog Output
DC
0.5 - 4
7 - 14
Extended Range Plus
DC
3 - 22
6 - 40
2-Wire
DC
2 - 10
4 - 15
Namur
DC
2 - 10
4 - 15
Standard Series
Plastic & Metal Housing
4 - 15
*All Sensing Distances in mm.
Operating Voltages – AC, DC Cylindrical Style
AC
90 - 250VAC
20 - 250VAC
DC
18 - 30VDC
10 - 30VDC
10 - 60VDC
Operating Current– AC, DC Cylindrical Style
AC
180 mA
500 mA
DC
5 mA
120 mA
200mA
400 mA
Sensor Wiring Systems – AC, DC Cylindrical Style
AC
2-Wire
DC
2-Wire
3-Wire
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
4-Wire
9
PREVIOUS
NON-FLUSH
CYLINDRICAL SENSORS
Sometimes called non-embedded
or non-shielded, non-flush sensors
have electromagnetic fields with a
wide sensing angle and are
unshielded (no metal surrounding
the sensing head). Care must be
taken to insure that no non-target
metal comes in near proximity to the
sensing head. Distances are
demonstrated in Figure 8. Adjacent
sensors should be separated by at
least 2 times the diameter. Non-target metal should be at least 3 times
the sensing distance directly across
from the sensing head. Two directly
opposite sensors should be at least
6 times the sensing distance apart.
Fig. 8
HOME
NEXT
FIND IT
CYLINDRICAL SENSOR INSTALLATION
Flush Mount Installation
(Mild Steel)
D
D
Non-Flush Mount Installation
(Mild Steel)
≥ 3 x Sn
2xD
D
D
Opposing Installation
D
OUTPUT CABLES
Cylindrical Sensors are provided
with 2 meter PVC fixed cables.
5 meter PVC, 2 and 5 meter PUR
cables are optional and specified
by selection of the last two digits of
the part number. See chart below.
Cable Length
& Material
Part No.
Last Digits
2m PVC
5m PVC
2m PUR
5m PUR
00
02
10
12
D
D
D
OUTPUT CONNECTIONS
AC,DC – Normally Open (NO),
and Normally Closed (NC).
DC Namur – Special interface
Circuits required.
DC Analog – Analog Output 1 to 9V.
≥ 3 x Sn
D
(Mild Steel)
≥ 6 x Sn
D
Quick Disconnect models are
designed to be user-friendly and to
simplify installations.
Please see the product specification for sensors with quick disconnect connectors and matching
cable assemblies on pages 116 to
121 in the accessory section.
QUICK DISCONNECT
HOUSING MATERIALS
CONNECTORS
Pulostronic sensors are available in AC – Nickel Plated Brass
Trogamid T
a wide selection of Quick
Teflon Plated Brass
Disconnect styles for DC and AC
circuits. While virtually any sensor
DC – Nickel Plated Brass
can be custom manufactured with a
Trogamid T
Quick Disconnect connector, Altech
Teflon Plated Brass
offers one of the largest selection of
Stainless Steel
standard Quick Disconnect models.
10
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
11
PREVIOUS
HOME
NEXT
FIND IT
DC CYLINDRICAL SENSORS – SELECTION GUIDE
Sensing Distance mm (in.)
Size
(mm)
Series
0.8mm
(.03 in.)
M8
L Series
18-30V DC, 120mA
1.0mm
(.04 in)
1.5mm
(.06 in.)
2.0mm
(.08 in.)
•
•
3.0mm
(.12 in.)
•
M12
• Short Body
• Economically
priced
2.5mm
(.10 in.)
4.0mm
(.16 in.)
5.0mm
(.20 in.)
6.0mm
(.23 in.)
7.0mm
(.28 in.)
8.0mm
(.32 in.)
•
•
•
M30
•
M12
•
•
M18
• 2 LED's
• NO & NC models
•
•
M30
•
M8
Standard Series
10-30V DC, 200mA
• Most quick
disconnects
• Industry standard
• NO & NC models
•
•
M12
•
•
M18
•
•
M30
•
M8
Extended Sensing
10-30V DC, 200mA
•
•
M12
• Up to 2x improvement over Standard
12.0mm
(.47 in.)
•
M18
GL Series
10-60V DC, 400mA
10.0mm
(.40 iin.)
•
M18
M30
•
Metal & Plastic
10-30V DC, 400mA
• Extended Length
• Higher Current Output
M12
Mini Housing
10-30V DC, 200mA
• 4, 5, 6.5mm diameter
• Includes LED
4mm Dia.
•
M5
•
•
•
M30
6.5mm Dia.
M12
•
•
•
•
•
M18
•
•
M30
High Speed
10-30V DC, 200mA
• 4,000 Hz Switching
Frequency
Extended Temperature
10-30V DC, 200mA
• -40°C to 100°C
©Altech
•
M18
Complementary
Switching Output
10-30V DC, 200mA
• NO & NC Outputs
12
•
M12
•
M12
•
M18
•
•
•
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
Output
Configuration
Mounting
14.0mm
(.55 in.)
15.0mm
(.59 in.)
•
•
•
•
•
20.0mm
(.78 in.)
22.0mm
(.86 in.)
40.0mm
(1.5 in.)
Flush
NEXT
Non-Flush NPN
PNP
NO
NC
FIND IT
Connection
Cable
2m (6ft.6in.)
Housing Material
64
65
No. of
Wires
Quick Disconnect
62
63
Metal (BN)
Brass Nickel Plated
NonMetallic
No.
of
LED's Page
•
•
•
•
•
•
•
•
3
•
1
16
•
•
•
•
•
•
•
•
3
•
1
17
•
•
•
•
•
•
•
3
•
1
18
•
•
•
•
•
•
•
3
•
1
19
•
•
•
•
•
•
•
•
3
•
2
20
•
•
•
•
•
•
•
•
3
•
2
21
•
•
•
•
•
•
•
•
3
•
2
22
•
•
•
•
•
•
•
•
•
•
3
•
1
24
•
•
•
•
•
•
•
•
•
•
3
•
1
25
•
•
•
•
•
•
•
•
•
•
3
•
1
26
•
•
•
•
•
•
•
•
•
3
•
1
27
•
•
•
•
•
•
3
•
1
28
•
•
•
•
•
3
•
1
29
•
•
•
•
•
3
•
1
29
•
•
•
•
•
3
•
1
30
•
•
•
•
•
•
•
•
3
•
•
1
32
•
•
•
•
•
•
3
•
•
1
32/33
•
•
•
•
•
•
3
•
•
1
33
•
•
•
•
•
•
3
•
1
34
•
•
•
•
•
•
3
•
1
34
•
•
•
•
3
• (ss)
1
35
•
•
•
•
•
4
•
1
36
•
•
•
•
•
4
•
1
37
•
•
•
•
•
4
•
1
•
•
•
•
3
•
1
31
•
•
•
•
•
•
•
•
•
•
3
•
1
38
•
•
•
•
•
•
3
•
1
39
Continued on Page 14/15
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
13
PREVIOUS
HOME
NEXT
FIND IT
DC CYLINDRICAL SENSORS – SELECTION GUIDE (Cont.)
Sensing Distance mm (in.)
Size
(mm)
Series
Weld-Immune
10-30V DC, 200mA
• Resistant to Electromagnetic Interference
• Teflon Plated
M12
2-Wire
5-30V DC, 100mA
10-55V DC, 200mA
M12
0.8mm
(.03 in.)
1.0mm
(.04 in)
1.5mm
(.06 in.)
2.0mm
(.08 in.)
2.5mm
(.10 in.)
3.0mm
(.12 in.)
4.0mm
(.16 in.)
•
5.0mm
(.20 in.)
6.0mm
(.23 in.)
7.0mm
(.28 in.)
8.0mm
(.32 in.)
10.0mm
(.40 iin.)
•
•
M18
•
•
M30
•
•
•
M18
• Reduce Wiring
• Lower Cost
•
•
M30
•
M8
Extended Range Plus
10-30V DC, 200mA
•
•
M12
• Up to 3 times
improvement over
Standard
12.0mm
(.47 in.)
•
•
M18
M30
Namur
Requires External
Amplifier
• Low Energy Device
• Operates in Hazardous
Areas
Analog
18-30V DC, 5mA
• 1-9V Linear Output
• Detects Target Distance
•
M8
•
•
M12
•
•
M18
•
•
M30
•
M12
•
M18
M30
AC CYLINDRICAL SENSORS – SELECTION GUIDE
Sensing Distance (mm/in.)
Series
Size
0.8mm
(.03 in.)
Standard Series
90-250V AC, 180 mA
M12
• Large Selection of
Quick Disconnects
• NO or NC Outputs
M18
Extended Voltage, Metal
20-250V AC, 500 mA
M12
2.0mm
(.08 in.)
•
2.5mm
(.10 in.)
4.0mm
(.16 in.)
5.0mm
(.20 in.)
7.0mm
(.28 in.)
8.0mm
(.32 in.)
•
•
M30
Extended Voltage, Plastic
20-250V AC, 500 mA
M12
•
• NO or NC Outputs
M30
Weld Immune
20-250V AC, 300/ 500 mA
• Resistance to Electro magnetic interference
• Teflon Plated
M12
•
M18
M30
•
•
•
•
•
•
•
•
•
•
M18
• High Current Output
•
•
•
•
10mm 14.0mm 15.0mm
(.40 in.) (.55 in.) (.59 in.)
•
M18
• NO or NC Outputs
©Altech
1.5mm
(.06 in.)
M30
• High Current Output
14
Mounting
•
•
•
•
Output
Configuration
Flush
Non-Flush
NO
NC
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
Mounting
14.0mm
(.55 in.)
15.0mm
(.59 in.)
20.0mm
(.78 in.)
22.0mm
(.86 in.)
40.0mm
(1.5 in.)
Flush
•
•
•
•
•
•
•
HOME
NEXT
Output
Configuration
Non-Flush NPN
PNP
NO
NC
FIND IT
Connection
Housing Material
65
No. of
Wires
Metal (BN)
Brass Nickel Plated
Quick Disconnect
Cable
2m (6ft.6in.)
62
63
64
NonMetallic
No.
of
LED's
Page
•
•
•
•
•
•
3
•
1
40
•
•
•
•
•
•
3
•
1
41
•
•
•
•
•
•
3
•
1
42
•
•
•
•
•
2
•
1
54
•
•
•
•
•
2
•
1
54
•
•
•
•
•
2
•
1
55
•
•
•
•
•
•
3
•
1
46
•
•
•
•
•
•
3
•
1
47
•
•
•
•
•
•
3
•
1
48
•
•
•
•
•
•
3
•
1
49
•
•
•
•
2
•
0
50
•
•
•
•
2
•
0
51
•
•
•
•
2
•
0
52
•
•
•
•
2
•
0
53
•
•
•
3
•
0
44
•
•
•
3
•
0
44
•
•
3
•
0
45
•
Connection
No. of
Wires (1)
•
Housing Material
Metal (BN)
No. of
LED's
Page
Cable
62
66
67
68
•
•
•
•
•
2
•
1
56
•
•
•
•
•
•
•
•
•
•
•
•
2
•
•
•
1
57
1
58/59
1
60
•
•
•
•
•
•
•
2
•
•
1
61
1
62/63
1
60
1
61
1
62/63
•
•
•
•
•
•
1
64
1
65
1
66
2
2
2
•
•
•
2
2
2
2
2
2
Plastic
•
•
•
(1) All metal sensors have a 3rd wire for optional system ground.
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
15
PREVIOUS
DC - 3 WIRE – L SERIES
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
M8 – 10-30V DC, 200mA
M12-M30 – 18-30V DC, 120mA
1 LED for Output Energized
HOME
• Short Body Sensors
• Economically priced
• Connector options
• Carries
mark
PNP
NPN
Normally Open
FIND IT
• IEC (529)IP67 (NEMA 1, 3, 4, 6, 12, 13)
Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M8 Flush Mount
M8 Non-Flush Mount
1.5mm (.06 in.)
2mm (.08 in.)
Sensing Distance
Cable or Connector Style Cat. No.
NEXT
Cable
64
65
Cable
64
65
9981-2000
9981-2064
9981-2065
9981-2200
9981-2264
9981-2265
9981-2100
9981-2164
9981-2165
9981-2300
9981-2364
9981-2365
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Current
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
2000Hz
2000Hz
2000Hz
2000Hz
2000Hz
2000Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.15mm (.006 in.)
.15mm (.006 in.)
.15mm (.006 in.)
.20mm (.008 in.)
.20mm (.008 in.)
.20mm (.008 in.)
PBTP
PBTP
PBTP
PBTP
PBTP
PBTP
M
M
8
8
x
x
1
1
LED
5
LED
30
1
x
x
8
8
2
40 4
50 29
5
1
LED
M
8
M
x
8
1
x
1
64 Style Connector
3-pin, Pico style, 8mm (.31 in.) supplied
with non-metallic locknuts for M8 and
Brass, Nickel Plated (BN) locknuts for
M12 through M30.
M
M
4 PORT
4 PORT
LED
50
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Non-metallic
locknuts for M8 and Brass, Nickel Plated
(BN) locknuts for M12 through M30.
35
Front Cap Material
35
Repeatability
M
28
23
5
1
1
LED
x
50
12
50
M
1
1
x
x
12
©Altech
M
16
x
8
8
M
LED
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with non-metallic locknuts for M8 and
Brass, Nickel Plated (BN) locknuts for
M12 through M30.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Accessories
Metric/in. Conversion Table
1.0 mm
5.0 mm
6.0 mm
8.0 mm
12.0 mm
23.0 mm
24.0 mm
28.0 mm
29.0 mm
= .04 in.
= .20 in.
= .23 in.
= .31 in.
= .47 in.
= .91 in.
= .94 in.
=1.10 in.
=1.14 in.
30.0 mm
34.0 mm
35.0 mm
39.0 mm
40.0 mm
50.0 mm
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
1.18 in.
1.34 in.
1.37 in.
1.53 in.
1.57 in.
1.96.in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
M12 Flush Mount
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Cable
64
65
Cable
64
65
9982-2000
9982-2064
9982-2065
9982-2200
9982-2264
9982-2265
9982-2100
9982-2164
9982-2165
9982-2300
9982-2364
9982-2365
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
18V - 30V
18V - 30V
18V - 30V
18V - 30V
18V - 30V
18V - 30V
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
120 mA
120 mA
120 mA
120 mA
120 mA
120 mA
≤1.5V
≤1.5V
≤1.5V
≤1.5V
≤1.5V
≤1.5V
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
2000Hz
2000Hz
2000Hz
1000Hz
1000Hz
1000Hz
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.20mm (.008 in.)
.20mm (.008 in.)
.20mm (.008 in.)
.40mm (.016 in.)
.40mm (.016 in.)
.40mm (.016 in.)
PBTP
PBTP
PBTP
PBTP
PBTP
PBTP
Note: Sensor dimensions in mm.
64 Connector 8000-5220 PVC, Straight
64 Connector 8000-5230 PVC, Right Angle, 2LED, PNP
64 Connector 8000-5240 PVC, Right Angle, 2LED, NPN
65 Connector 8000-5110 PVC, Straight
65 Connector 8000-5120 PVC, Right Angle
65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN
65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more
cable information
Mounting Brackets – see Page 114-115
Wiring Diagrams
Note; Wire colors are applicable on cables
purchased from Altech.
NPN
1
1
x
LED
LED
Fixed Cable
Fixed Cable
x
12
12
M
M
PNP
+
BR
+
BR
•
LOAD
6
BK
BK
35
35
LOAD
•
BL –
BL
Normally Open
64 Connector
64 Connector
M
M
12
12
x
x
4 PORT
LED
1
1
1
1
+
BR
6
4- PORT LED
BR
• +
LOAD
2/4
8
40
M
M
x
8
1
50
1
x
4
50 0
24
30
BK
LOAD
BL • –
BK
2/4
BL
3
–
3
Normally Open
Normally Open
65 Connector
65 Connector
M
M
12
12
x
x
1
1
LED
LED
6
1
1
4 BK
x
2
3
•
BL
–
•
+
LOAD
4
BK
2
Normally Open
3 BL
–
Normally Open
1
1
50
40
24
30
x
12
12
4
50 0
BR
BR +
LOAD
M
M
©Altech
–
Normally Open
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
17
PREVIOUS
DC - 3 WIRE – L SERIES
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
18-30V DC, 120mA
1 LED for Ouput Energized
HOME
• Short Body Sensors
• Economically priced
• Connector options
• Carries
mark
Cable or Connector Style Cat. No.
NPN
Normally Open
FIND IT
• IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M18 Flush Mount
M18 Non-Flush Mount
5mm (.20 in.)
8mm (.31in.)
Sensing Distance
PNP
NEXT
Cable
65
Cable
65
9984-2000
9984-2065
9984-2200
9984-2265
9984-2100
9984-2165
9984-2300
9984-2365
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
Voltage Range
18V - 30V
18V - 30V
18V - 30V
18V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
120 mA
120 mA
120 mA
120 mA
Voltage Drop Across Sensor
≤1.5V
≤1.5V
≤1.5V
≤1.5V
Max. Leakage Current
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
1000Hz
1000Hz
500Hz
500Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
.50mm (.02 in.)
.50mm (.02 in.)
.80mm (.031in.)
.80mm (.031 in.)
PBTP
PBTP
PBTP
PBTP
Repeatability
Front Cap Material
LED
1
1
x
x
18
18
M
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
35
35
8
LED
M
a
18
18
M
1
3
40 0
50
x
3
4 0
50 0
12
12
©Altech
M
M
18
LED
1
LED
1
x
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Accessories
Metric/in. Conversion Table
1.5 mm
2.0 mm
4.0 mm
5.0 mm
6.0 mm
8.0 mm
10.0 mm
12.0 mm
15.0 mm
18.0 mm
=
=
=
=
=
=
=
=
=
=
.06 in.
.08 in.
.16 in
.20 in.
.23 in.
.31 in.
.39 in.
.47 in.
.59 in.
.70 in.
23.0 mm
28.0 mm
30.0 mm
32.0 mm
34.0 mm
40.0 mm
50.0 mm
51.0 mm
60.0 mm
80.0 mm
=
=
=
=
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
.91 in.
1.10 in
1.18 in.
1.26 in.
1.38 in.
1.57 in.
1.97 in.
2.01 in.
2.36 in.
3.12 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
65 Connector
65 Connector
65 Connector
65 Connector
8000-5110
8000-5120
8000-5150
8000-5160
PVC, Straight
PVC, Right Angle
PVC, Right Angle, 2LED, NPN
PVC, Right Angle, 2LED, PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more
cable information
M30 Flush Mount
M30 Non-Flush Mount
10mm (.39 in.)
15mm (.59 in.)
Mounting Brackets – see Pages 114-115
Cable
65
Cable
65
9986-2000
9986-2065
9986-2200
9986-2265
9986-2100
9986-2165
9986-2300
9986 -2365
≤10%
≤10%
≤10%
≤10%
18V - 30V
18V - 30V
18V - 30V
18V - 30V
≤10 mA
≤10 mA
≤10 mA
≤10 mA
120 mA
120 mA
120 mA
120 mA
≤1.5V
≤1.5V
≤1.5V
≤1.5V
≤10 µA
≤10 µA
≤10 µA
≤10 µA
500Hz
500Hz
300Hz
300Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
1.0mm (.039 in.)
1.0mm (.039 in.)
1.5mm (.059 in.)
1.5mm (.059 in.)
PBTP
PBTP
PBTP
PBTP
Note: Sensor dimensions in mm.
Wiring Diagrams
M
M
Note: Wire colors are applicable on cables
purchased from Altech
30
30
x
x
1.
1
PNP
5
LED
LED
NPN
Fixed Cable
Fixed Cable
+
BR
BR
•
12
BK
BK
LOAD
• –
23
35
+
LOAD
BL
BL
–
Normally Open
65 Connector
65 Connector
M
Normally Open
x
30
30
M
5
1.
5
1.
LED
x
LED
BR
BR +
1
1
4 BK
12
M
3
BL
2
3 BL
–
Normally Open
Normally Open
50
40
1
50
18
x
©Altech
1
12
3
40 0
x
M
12
2
–
+
LOAD
BK
LOAD
•
•
4
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
19
PREVIOUS
DC - 3 WIRE – GL SERIES
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-60V DC, 400mA,
2 LED's for Operating Voltage
and Output Energized
HOME
NEXT
• Higher Current Output
• Higher Voltage Range
• Carries
mark
FIND IT
• IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M12 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Cable
64
65
Cable
64
65
Normally Open
9982-4000
9982-4064
9982-4065
9982-4200
9984-4264
9982-4265
Normally Closed
9982-4400
9982-4464
9982-4465
9982-4600
9982-4664
9982-4665
Normally Open
9982-4100
9982-4164
9982-4165
9982-4300
9982-4364
9982-4365
Normally Closed
9982-4500
9982-4564
9982-4565
9982-4700
9982-4764
9982-4765
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V - 60V
10V - 60V
10V - 60V
10V - 60V
10V - 60V
10V - 60V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
400 mA
400 mA
400 mA
400 mA
400 mA
400 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
PNP
NPN
Voltage Drop Across Sensor
Max. Leakage Current
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
2000Hz
2000Hz
2000Hz
1000Hz
1000Hz
1000Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.20mm (.008 in.)
.20mm (.008 in.)
.20mm (.008 in.)
.40mm (.016 in.)
.40mm (.016 in.)
.40mm (.016 in.)
PBTP
PBTP
PBTP
PBTP
PBTP
PBTP
M
1
1
x
x
12
12
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
2 LED
45 35
6
2 LED
29
Front Cap Material
45
Repeatability
M
x
12
12
M
1
x
1
2 LED
2 LED
2
50 9
M
8
x
8
1
x
1
60
M
5 35
60 0
6
64 Style Connector
3-pin, Pico style, 8mm (.31 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
M
12
M
x
12
1
x
1
2 LED
20
©Altech
2
5 9
60 0
5 35
60 0
6
2 LED
65 Style Connectors
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Accessories
Metric/in. Conversion Table
1.0 mm = .04 in.
6.0 mm = .23 in.
8.0 mm = .31 in.
12.0 mm = .47 in.
18.0 mm = .70 in.
.27.0 mm =1.06 in.
M18 Flush Mount
29.0 mm
35.0 mm
45.0 mm
50.0 mm
60.0 mm
80.0 mm
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
1.14 in
1.37 in.
1.77 in.
1.97 in.
2.36 in.
3.15 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
M18 Non-Flush Mount
5mm (.20 in.)
FIND IT
64 Connector
64 Connector
64 Connector
8000-5220 PVC, Straight
8000-5230 PVC, Right Angle, 2LED, PNP
8000-5240 PVC, Right Angle, 2LED, NPN
65 Connectors, 4 PIN – 3 Wire cable (PIN 1, 3, 4 ) :
65 Connector 8000-5110 PVC, Straight
65 Connector 8000-5120 PVC, Right Angle
65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN
65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP
65 Connectors, 4 PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
65 Connector 8000-5280
PVC Right Angle
Change last digit of connector number to 5
for 5 meter cable
8mm (.31 in.)
Refer to pages 116-121 for more cable information
Cable
65
Cable
65
9984-4000
9984-4065
9984-4200
9984-4265
9984-4400
9984-4465
9984-4600
9984-4665
Wiring Diagrams
9984-4100
9984-4165
9984-4300
9984-4365
9984-4500
9984-4565
9984-4700
9984-4765
Note: Wire colors are applicable on cables
purchased from Altech
≤10%
≤10%
≤10%
≤10%
10V - 60V
10V - 60V
10V - 60V
10V - 60V
Mounting Brackets – see Pages 114-115
PNP
NPN
Fixed Cable
Fixed Cable
+
BR
≤10 mA
≤10 mA
≤10 mA
≤10 mA
400 mA
400 mA
400 mA
400 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤10 µA
≤10 µA
≤10 µA
≤10 µA
1000Hz
1000Hz
500Hz
500Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
BR
.25mm (.01 in.)
.25mm (.01 in.)
.40mm (.016 in.)
.40mm (.016 in.)
BK
PBTP
PBTP
PBTP
PBTP
+
BR
•
LOAD
BK
BK
LOAD
• –
BL
–
BL
Normally Open
Normally Open
Fixed Cable
Fixed Cable
+
BR
•
+
LOAD
BK
LOAD
•
–
BL
–
BL
Normally Closed
Normally Closed
Note: Sensor dimensions in mm.
M
M
18
18
x
x
1
1
1
1
BR
+
BR
• +
LOAD
BK
2 LED
2 LED
64 Connector
64 Connector
2/4
LOAD
BL • –
BK
–
BL
3
3
Normally Open
Normally Open
64 Connector
64 Connector
45
27
3
45 5
8
2/4
1
1
+
BR
BR
• +
LOAD
BK
2/4
2/4
LOAD
BL• –
BK
–
BL
3
3
Normally Closed
Normally Closed
65 Connector
65 Connector
BR +
1
4 BK
BR
1
•
3
–
BL
LOAD
BK
LOAD
2
+
•
4
2
Normally Open
x
18
18
M
M
Normally Open
–
3 BL
x
1
1
2 LED
2
50 7
8
BR
1
4
2
3
•
BR
+
BL
–
LOAD
1
4
2
3
WHT
Normally Closed
©Altech
•
+
LOAD
BL
–
60
50 35
60
65 Connector
65 Connector
2 LED
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
WHT
Normally Closed
21
PREVIOUS
DC - 3 WIRE – GL SERIES
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-60V DC, 400mA
2 LED's for Operating Voltage
and Output Energized
HOME
NEXT
• Higher Current Output
• Higher Voltage Range
• Carries
mark
• IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M30 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
FIND IT
M30 Non-Flush Mount
10mm (.39 in.)
15mm (.59 in.)
Cable
65
Cable
65
Normally Open
9986-4000
9986-4065
9986-4200
9986-4265
Normally Closed
9986-4400
9986-4465
9986-4600
9986-4665
Normally Open
9986-4100
9986-4165
9986-4300
9986-4365
Normally Closed
9986-4500
9986-4565
9986-4700
9986-4765
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-60V
10V - 60V
10V - 60V
10V - 60V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
400 mA
400 mA
400 mA
400 mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
500 Hz
500 Hz
300 Hz
300 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
.75mm (.030 in.)
.75mm (.030 in.)
PBTB
PBTB
PNP
NPN
Repeatability
.50mm (.020 in.)
Front Cap Material
.50mm (.020 in.)
PBTP
PBTP
Note: Sensor dimensions in mm.
M
5
5
1,
1,
x
x
30
30
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
2 LED
45
23
3
45 5
12
2 LED
M
M
30
30
x
x
2 LED
5
5
1,
1,
2 LED
22
©Altech
23
50
60
60
50 35
12
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
Accessories
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
65 Connectors, 4 PIN – 3 Wire cable (PIN 1, 3, 4) :
65 Connector 8000-5110 PVC, Straight
65 Connector 8000-5120 PVC, Right Angle
65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN
65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP
65 Connectors, 4PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
65 Connectors 8000-5280 PVC, Right Angle
1.5 mm
12.0 mm
23.0 mm
35.0 mm
= .06 in.
= .47 in.
= .90 in.
= 1.37 in.
45.0 mm = 1.77 in.
50.0 mm = 1.96 in.
60.0 mm = 2.36 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
Wiring Diagrams
Note: Wire colors are applicable on cable
purchased from Altech
PNP
NPN
Fixed Cable
Fixed Cable
+
BR
+
BR
•
LOAD
BK
BK
LOAD
• –
BL
Normally Open
Fixed Cable
Fixed Cable
BR
+
•
LOAD
BK
LOAD
•
BL
+
BR
BK
–
–
BL
Normally Closed
Normally Closed
65 Connector
65 Connector
BR +
4 BK
1
BR
1
•
3
–
BL
2
65 Connector
BR
+
1
4
3
–
Normally Open
65 Connector
1
LOAD
3 BL
2
Normally Open
BR
+
•
4
BK
LOAD
2
BL
• –
LOAD
WHT
Normally Closed
©Altech
–
BL
Normally Open
2
4
3
•
+
LOAD
BL
–
WHT
Normally Closed
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
23
PREVIOUS
HOME
NEXT
FIND IT
• Most complete range of Fixed Cable
and Quick Disconnect Styles
• Available in normally open (N.O.)
and normally closed (N.C.) output
configuration
• Industry standard 10-30V DC operating
voltage and 200mA output current
• Carries
mark
DC - 3 WIRE STANDARD
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200 mA,
1 LED for Output Energized
• IEC (529) IP67 (NEMA 1, 3, 4, 6,
12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M8 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
M8 Non-Flush Mount
1.5mm (.06 in.)
2mm (.08 in.)
Cable
63
64
65
Cable
63
64
65
PNP
Normally Open
9961-0200
9961-0263
9961-0264
9961-0265
9961-0400
9961-0463
9961-0464
9961-0465
Normally Closed
9961-4400
9961-4464
9961-4465
9961-4600
9961-4664
9961-4665
NPN
Normally Open
9961-0300
9961-0364
9961-0365
9961-0500
Normally Closed
9961-4500
9961-4564
9961-4565
9961-4700
9961-0363
9961-0563
9961-0564
9961-0565
9961-4764
9961-4765
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Voltage Drop Across Sensor
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
2000 Hz
2000 Hz
2000 Hz
2000 Hz
2000 Hz
2000 Hz
2000 Hz
2000 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.15mm (.006 in.)
.15mm (.006 in.) .15mm (.006 in.) .15mm (.006in.)
PBTP
PBTP
PBTP
.20mm (.008in.)
.20mm (.008in.) .20mm (.008in.)
PBTB
PBTB
M
8
1
1
x
x
8
5
40
43
1
x
x
8
8
M
M
5
29
50 34
8
x
1
1
x
8
8
M
M
1
1
x
LED (65 CN)
x
LED (63 CN)
1
1
x
x
12
50
M
12
50
23
28
5
LED (63 CN)
M
©Altech
50
M
8
24
1
4 PORT
LED
4 PORT
LED
LED (65 CN)
63 and 65 Style Connectors
4-pin, Micro style, 12mm (.47 in.) supplied
with Non-metallic locknuts for M8 and
Brass, Nickel Plated (BN) locknuts for
M12 through M30. The 63 Connector is clear,
offering 360° LED viewing.
PBTB
LED
LED
M
64 Style Connector
3-pin, Pico style, 8mm (.31 in.) supplied
with non-metallic locknuts for M8 and
Brass, Nickel Plated (BN) locknuts for
M12 through M30.
.20mm (.008in.)
PBTB
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Non-metallic
locknuts for M8 and Brass, Nickel Plated
(BN) locknuts for M12 through M30.
PBTP
35
Front Cap Material
43
Repeatability
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Accessories
Metric/in. Conversion Table
1.0 mm
5.0 mm
6.0 mm
8.0 mm
12.0 mm
23.0 mm
28.0 mm
M12 Flush Mount
29.0 mm
34.0 mm
35.0 mm
40.0 mm
43.0 mm
50.0 mm
60.0 mm
= .04 in.
= .20 in.
= .23 in.
= .31 in.
= .47 in.
= .90 in.
=1.10 in.
=
=
=
=
=
=
=
1.14 in.
1.34 in.
1.37 in.
1.57 in.
1.69 in.
1.47 in.
2.36 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
64 Connector 8000-5220 PVC, Straight
64 Connector 8000-5230 PVC, Right Angle, 2LED, PNP
64 Connector 8000-5240 PVC, Right Angle, 2LED, NPN
63/65 Connectors, 4 PIN – 3 Wire cable (PIN 1, 3, 4) :
63/65 Connector 8000-5110 PVC, Straight
63/65 Connector 8000-5120 PVC, Right Angle
63/65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN
63/65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP
63/65 Connectors, 4PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
63/65 Connectors 8000-5280 PVC, Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Cable
63
64
65
Cable
63
64
65
9962-4000
9962-4063
9962-4064
9962-4065
9962-4200
9962-4263
9962-4264
9962-4265
9962-4464
9962-4465
9962-4600
9962-4664
9962-4665
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
9962-4400
9962-4100
9962-4163
9962-4500
9962-4164
9962-4165
9962-4300
9962-4564
9962-4565
9962-4700
9961-4363
9962-4364
9962-4365
9962-4764
9962-4765
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10µA
≤10µA
≤10µA
≤10µA
2000 Hz
2000 Hz
2000 Hz
2000 Hz
1000 Hz
1000 Hz
1000 Hz
1000 Hz
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.20mm (.008in.) .20mm (.008in.) .20mm (.008in.) .20mm (.008in.)
Mounting Brackets – see Pages 114-115
PNP
NPN
Fixed Cable
Fixed Cable
•
LOAD
BK
BK
LOAD
•
BL –
Fixed Cable
Fixed Cable
+
BR
BR
•
PBTB
PBTB
PBTB
PBTB
PBTB
PBTB
BK
PBTB
•
BL
BK
BL
M
M
64 Connector
12
12
1
1
x
x
1
1
BR
+
BR
2/4
LOAD
BK
2/4
LOAD
BL • –
6
34
40
• +
BK
–
BL
3
3
Normally Open
Normally Open
64 Connector
64 Connector
1
1
+
BR
BR
• +
LOAD
BK
M
M
12
12
2/4
x
x
BK
2/4
LOAD
BL• –
1
4 PORT
LED
–
BL
3
3
Normally Closed
Normally Closed
34
63/65 Connector
BR +
BR
x
x
60
8
8
60
63/65 Connector
50
M
M
4
50 0
6
1
4 PORT
LED
–
Normally Closed
64 Connector
LED
LED
–
Normally Closed
Note: Sensor dimensions in mm.
+
LOAD
LOAD
PBTB
–
BL
Normally Open
Normally Open
.40mm (.016in.) .40mm (.016in.) .40mm (.016in.) .40mm (.016in.)
+
BR
+
BR
1
1
1
4 BK
1
2
–
3 BL
Normally Open
x
x
1
1
65 Connector
63/65 Connector
LED (63 CN)
BR
BR
+
•
+
4
2
3
1
4
2
3
•
BK
–
LOAD
WHT
Normally Closed
©Altech
LOAD
34
1
50
60
60
4
50 0
6
LED (63 CN)
2
12
12
LED (65 CN)
BL
Normally Open
M
M
LED (65 CN)
3
–
LOAD
BK
LOAD
•
+
•
4
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
BL
–
WHT
Normally Closed
25
PREVIOUS
DC - 3 WIRE – STANDARD
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA,
1 LED for Output Energized
HOME
NEXT
• Most complete range of Fixed Cable
and Quick Disconnect Styles
• Available in normally open (N.O.)
and normally closed (N.C.) output
configuration
• Industry standard 10-30V DC operating
voltage and 200mA output current
• Carries
mark
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6,
12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M18 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
PNP
NPN
M18 Non-Flush Mount
5mm (.20 in.)
8mm (.31 in.)
Cable
63
65
Cable
63
65
Normally Open
9964-4000
9964-4063
9964-4065
9964-4200
9964-4263
9964-4265
Normally Closed
9964-4400
9964-4465
9964-4600
Normally Open
9964-4100
9964-4165
9964-4300
Normally Closed
9964-4500
9964-4163
9964-4665
9964-4363
9964-4365
9964-4565
9964-4700
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
≤10%
9964-4765
≤10%
Voltage Range
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
1000 Hz
1000 Hz
1000 Hz
500 Hz
500 Hz
500 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.25mm (.01 in.)
.25mm (.01 in.)
.25mm (.01 in.)
.40mm (.016 in.)
.40mm (.016 in.)
.40mm (.016 in.)
PBTP
PBTP
PBTP
PBTB
PBTB
PBTB
M
x
18
18
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
1
x
1
LED
8
LED
40
40
18
x
1
1
x
8
32
12
x
1
1
x
4
5 0
60 1
M
12
©Altech
LED (63 CN)
LED (63 CN)
M
26
18
63 and 65 Style Connectors
4-pin, Micro style, 12mm (.47 in.)
supplied with Brass, Nickel Plated (BN)
locknuts.The 63 Connector is clear,
offering 360° LED viewing.
M
LED (65 CN)
M
LED (65 CN)
5
60 1
Front Cap Material
32
Repeatability
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
1.5 mm
2.0 mm
4.0 mm
5.0 mm
6.0 mm
8.0 mm
10.0 mm
12.0 mm
15.0 mm
18.0 mm
=
=
=
=
=
=
=
=
=
=
.06 in.
.08 in.
.16 in
.20 in.
.23 in.
.31 in.
.39 in.
.47 in.
.59 in.
.70 in.
Accessories
23.0 mm
28.0 mm
30.0 mm
32.0 mm
34.0 mm
40.0 mm
50.0 mm
51.0 mm
60.0 mm
80.0 mm
=
=
=
=
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
.91 in.
1.10 in
1.18 in.
1.26 in.
1.34 in.
1.57 in.
1.97 in.
2.01 in.
2.36 in.
3.12 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
63/65 Connectors, 4 PIN – 3 Wire cable (PIN 1, 3, 4) :
63/65 Connector 8000-5110 PVC, Straight
63/65 Connector 8000-5120 PVC, Right Angle
63/65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN
63/65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP
63/65 Connectors, 4PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
63/65 Connectors 8000-5280 PVC, Right Angle
Change last digit of connector number to 5
for 5 meter cable
M30 Flush Mount
M30 Non-Flush Mount
10mm (.39 in.)
15mm (.59 in.)
Refer to pages 116-121 for more cable information
Cable
63
65
Cable
63
65
9966-4000
9966-4063
9966-4065
9966-4200
9966-4263
9966-4265
9966-4465
9966-4600
9966-4665
9966-4165
9966-4300
9966-4365
9966-4400
9966-4100
9966-4163
9966-4500
9966-4565
9966- 4700
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
≤10 mA
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≥10 µA
≥10 µA
≥10 µA
≥10µA
≥10µA
≥10µA
500 Hz
500 Hz
500 Hz
300 Hz
300 Hz
300 Hz
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.50mm (.02 in.)
.50mm (.02 in.)
.50mm (.02 in.)
.75mm (.03 in.)
.75mm (.03 in.)
.75mm (.03 in.)
PBTB
PBTB
PBTB
PBTB
PBTB
PBTB
Mounting Brackets – see Pages 114-115
9966-4765
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
Note: Sensor dimensions in mm.
PNP
NPN
Fixed Cable
Fixed Cable
+
BR
•
M
M
LOAD
30
30
BK
x
x
BK
5
5
1,
1,
LOAD
•
BL –
LED
LED
12
Fixed Cable
Fixed Cable
28
+
BR
•
40
BR
BK
LOAD
•
BL
–
M
Normally Closed
63/65 Connector
63/65 Connector
BR
5
5
1,
1,
x
LED (63 CN)
12
2
3
–
BL
3 BL
2
Normally Open
63/65 Connector
63/65 Connector
BR
BR
12
5
60 1
1
1
x
x
12
28
+
1
4
2
3
•
BL
–
LOAD
1
4
2
3
•
+
LOAD
BL
–
WHT
WHT
Normally Closed
©Altech
–
Normally Open
M
M
4
5 0
60 1
•
+
LOAD
BK
LOAD
x
30
LED (63 CN)
4 BK
•
4
1
30
M
LED (65 CN)
–
BL
Normally Closed
BR +
1
+
LOAD
BK
LED (65 CN)
–
BL
Normally Open
Normally Open
40
+
BR
Normally Closed
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
27
PREVIOUS
DC - 3 WIRE – EXTENDED
SENSING DISTANCE
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
HOME
NEXT
• Up to 2 times sensing distance
over standard sensors
• Reduces accidental collisions
• Ideal for applications where larger
sensing distance is required but
mounting space is tight
• Carries
mark
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M8 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
PNP
Normally Open
NPN
Normally Open
M8 Non-Flush Mount
2mm (.08 in.)
3mm (.12 in.)
Cable
64
65
Cable
64
65
9981-4000
9981-4064
9981-4065
9981-4200
9981-4264
9981-4265
9981-4100
9981-4164
9981-4165
9981-4300
9981-4364
9981-4365
Normally Closed
Normally Closed
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤12 mA
≤12 mA
≤12 mA
≤12 mA
≤12 mA
≤12 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
2000 Hz
2000 Hz
2000 Hz
2000 Hz
2000 Hz
2000 Hz
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
Repeatability
Front Cap Material
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.2mm (.008 in.)
.2mm (.008 in.)
.2mm (.008 in.)
.3mm (.012 in.)
.3mm (.012 in.)
.3mm (.012 in.)
PBTP
PBTP
PBTP
PBTB
PBTB
PBTB
M
8
8
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Non-metallic
locknuts for M8 and Brass, Nickel Plated
(BN) locknuts for M12 through M30.
x
x
1
1
LED
35
LED
5
Temperature Drift
35
Hysterisis
M
8
M
1
1
x
x
8
LED
2
50 9
8
M
50 34
5
LED
M
8
x
64 Style Connector
3-pin, Pico style, 8mm (.31 in.) supplied
with non-metallic locknuts for M8 and
Brass, Nickel Plated (BN) locknuts for
M12 through M30.
x
1
1
1
1
x
x
12
50
M
50
23
28
5
1
LED
1
12
©Altech
x
x
M
28
8
8
M
M
LED
50/65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Non-Metallic locknuts for M8 and
Brass, Nickel Plated (BN) locknuts for
M12 through M30.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
1.0 mm
5.0 mm
8.0 mm
12.0 mm
23.0 mm
27.0 mm
28.0 mm
M12 Flush Mount
= .04 in.
= .20 in.
= .31 in.
= .47 in.
= .90 in.
=1.06 in.
=1.10 in.
Accessories
29.0 mm
30.0 mm
34.0 mm
35.0 mm
40.0 mm
50.0 mm
=
=
=
=
=
=
1.14 in.
1.18 in.
1.33 in.
1.37 in.
1.57 in.
1.96 in.
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
M18 Flush Mount
4mm (.16 in.)
8mm (.31 in.)
Cable
65
Cable
65
9982-4900
9982-4950
9984-4900
9984-4950
64 Connector
64 Connector
64 Connector
8000-5220 PVC, Straight
8000-5230 PVC, Right Angle, 2LED, PNP
8000-5240 PVC, Right Angle, 2LED, NPN
50/65 Connector 8000-5110
50/65 Connector 8000-5120
50/65 Connector 8000-5150
50/65 Connector 8000-5160
PVC, Straight
PVC, Right Angle
PVC, Right Angle, 2LED, NPN
PVC, Right Angle, 2LED, PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
≤10%
≤10%
≤10%
≤10%
10V - 30V
10V - 30V
10V - 30V
10V - 30V
≤12mA
≤12 mA
≤12 mA
≤12 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
10 µA
10 µA
10µA
10µA
1500 Hz
1500 Hz
500 Hz
500 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
.40mm (.016 in.)
PBTB
.40mm (.016 in.)
PBTB
≤10%
≤10%
.80mm (.03 in.)
.80mm (.03in.)
PBTB
PBTB
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
PNP
NPN
Fixed Cable
Fixed Cable
BR
+
•
LOAD
BK
LOAD
• –
BL
–
BL
Normally Open
Normally Open
64 Connector
64 Connector
1
1
BR
+
BR
• +
LOAD
BK
2/4
BK
2/4
LOAD
BL • –
BL
–
3
3
Normally Open
Normally Open
50/65 Connector
50/65 Connector
BR
BR +
1
+
BR
BK
1
4 BK
•
+
LOAD
4
BK
LOAD
2
3
•
BL
–
2
Normally Open
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
3 BL
–
Normally Open
29
PREVIOUS
DC - 3 WIRE – EXTENDED
SENSING DISTANCE
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Ouput Energized
HOME
NEXT
• Up to 2 times sensing distance
over standard sensors
• Reduces accidental collisions
• Ideal for applications where larger
sensing distance is required but
mounting space is tight
• Carries
mark
Cable or Connector Style Cat. No.
PNP
NPN
Normally Open
• IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13)
Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C
(-13 to 158°F)
Metric/in. Conversion Table
M30 Flush Mount
Sensing Distance
FIND IT
1.5 mm
30.0 mm
50.0 mm
60.0 mm
80.0 mm
15mm (.59 in.)
Cable
65
9966-3900
9966-3965
Normally Closed
=
=
=
=
=
.06 in.
1.20 in.
1.47 in.
2.36 in.
3.12 in.
This table converts millimeters to inches in reference
to the illustrations included on these pages
Normally Open
Normally Closed
Ripple Voltage
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
Supply Current
≤12 mA
≤12 mA
Max. Load Current
200 mA
200 mA
Accessories
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
65 Connector 8000-5110 PVC, Straight
65 Connector 8000-5120 PVC, Right Angle
65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN
65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP
Voltage Drop Across Sensor
≤2.4V
≤2.4V
Max. Leakage Currrent
≤10 µA
≤10 µA
Switching Frequency
200 Hz
200 Hz
Hysterisis
≤15%
≤15%
Temperature Drift
≤10%
≤10%
1.5mm (.06 in.)
1.5mm (.06 in.)
PBTP
PBTP
Repeatability
Front Cap Material
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
Note: Sensor dimensions in mm.
Wiring Diagrams
M
30
x
PNP
5
1,
Fixed Cable
LED
BR
+
BK
LOAD
• –
BL
5
60 0
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
Note: Wire colors are applicable to cable
purchased from Altech
Normally Open
M
30
x
1,
5
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
65 Connector
LED
BR +
1
4 BK
LOAD
3
•
BL
–
60
2
80
Normally Open
30
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
DC - 3 WIRE
HIGH SPEED
Brass, Nickel Plated (BN),
Cylindrial,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
HOME
NEXT
• Switching frequency of 4000 Hz
• Standard body length
• Carries
mark
Cable or Connector Style Cat.No.
PNP
Normally Open
• IEC (529) IP67 (NEMA 1, 3, 4, 6, 12, 13)
Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C
(-13 to 158°F)
Metric/in. Conversion Table
M12 Flush Mount
Sensing Distance
FIND IT
1.0 mm
12 mm
40.0 mm
45.0 mm
50.0 mm
65.0 mm
2mm (.08 in.)
Cable
65
9962-2300
9962-2365
=
=
=
=
=
=
.04 in.
.47 in.
1.57 in.
1.77 in.
1.96 in.
2.55 in.
This table converts millimeters to inches in reference
to the illustrations included on these pages
Ripple Voltage
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
≤2.4V
≤2.4V
Voltage Drop Across Sensor
Accessories
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
65 Connector 8000-5110 PVC, Straight
65 Connector 8000-5120 PVC, Right Angle
65 Connector 8000-5150 PVC, Right Angle, 2LED, NPN
65 Connector 8000-5160 PVC, Right Angle, 2LED, PNP
≤10 µA
≤10 µA
4000 Hz to DIN 500 10
4000 Hz to DIN 500 10
Hysterisis
≤15%
≤15%
Temperature Drift
≤10%
≤10%
.20mm (.008 in.)
.20mm (.008 in.)
PBTP
PBTP
Max. Leakage Currrent
Switching Frequency
Repeatability
Front Cap Material
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
Note: Sensor dimensions in mm.
Wiring Diagrams
M
12
x
1
Note: Wire colors are applicable to cable
purchased from Altech
PNP
LED
40
Fixed Cable
BR
+
50
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
BK
LOAD
• –
BL
Normally Open
M
12
x
1
LED
65 Connector
BR +
45
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
4 BK
65
1
LOAD
2
3
•
BL
–
Normally Open
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
31
PREVIOUS
HOME
NEXT
• Metal and plastic
housings
• Higher output
currents, 400mA
• Long body length
DC - 3 WIRE – PLASTIC & METAL
HOUSING – Brass, Nickel Plated
(BN), and Plastic (TROGAMID T)
Cylindrical,Threaded,
10-30V DC, 400mA
1 LED for Output Energized
• Carries
Sensing Distance
Normally Open
NPN
Normally Open
M18 Flush Mount
4mm (.16 in.)
5mm (.20 in.)
Cable
Cable
Cable
9962-3100
9962-1400
9962-3300
9962-1600
9964-3100
9964-1500
9962-3200
9962-1500
9962-3400
9962-1700
9964-3200
9964-1600
Normally Closed
Normally Closed
Ripple Voltage
≥10%
≥10%
≥10%
≥10%
≥10%
≥10%
Voltage Range
10-30V
10-30V
10-30V
10-30V
10-30V
10-30V
Supply Current
≥10 mA
≥10 mA
≥10 mA
≥10 mA
≥10 mA
≥10 mA
Max. Load Current
400 mA
400 mA
400 mA
400 mA
400 mA
400 mA
Voltage Drop Across Sensor
≥2.4V
≥2.4V
≥2.4V
≥2.4V
≥2.4V
≥2.4V
Max. Leakage Current
≥10 µA
≥10 µA
≥10 µA
≥10 µA
≥10 mA
≥ 10mA
Switching Frequency
2000Hz
2000Hz
1000Hz
1000Hz
1000Hz
1000Hz
Hysterisis
≥15%
≥15%
≥15%
≥15%
≥15%
≥15%
≥10%
≥10%
≥10%
≥10%
≥10%
≥10%
.20mm (.008 in.)
.20mm (.008 in.)
.40mm (.016 in.)
.40mm (.016 in.)
.5mm (.02 in.)
.5mm (.02 in.)
Front Cap Material
Housing Material
PBTB
PBTB
PBTB
PBTB
Trogamid T
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
M
M
18
x
1
LED
1
1
x
x
12
12
©Altech
PBTB
Nickel Plated Brass
M
LED
6
LED
50
34
40
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
non-metallic locknuts for Trogamid T
housings, and Brass, Nickel Plated
(BN) locknuts for Nickel Plated Brass
housings.
PBTB
Trogamid T
50
Repeatability
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
5
60 0
Temperature Drift
32
M12 Non-Flush Mount
2mm (.08 in.)
Cable or Connector Cat. No.
PNP
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
mark
M12 Flush Mount
FIND IT
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
1 mm
1.5 mm
6.0 mm
8.0 mm
12.0 mm
18.0 mm
30.0 mm
= .04 in.
= .06 in.
= .23 in.
= .31 in.
= .47 in.
= .70 in.
=1.20 in.
M18 Non-Flush Mount M30 Flush Mount
8mm (.31 in.)
10mm (.39 in.)
Cable
Accessories
34.0 mm
38.0 mm
40.0 mm
42.0 mm
50.0 mm
60.0 mm
=
=
=
=
=
=
1.31 in.
1.50 in.
1.57 in.
1.65 in.
1.97 in.
2.36 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
Mounting Brackets – see Pages 114-115
M30 Non-Flush Mount
15mm (.59 in.)
Cable
Cable
9964-3300
9964-1700
9966-3100
9966-1100
9966-3300
9966-1300
9964-3400
9964-1800
9966-3200
9966-1200
9966-3400
9966-1400
≥10%
≥10%
≥10%
≥10%
≥10%
≥10%
10-30V
10-30V
10-30V
10-30V
10-30V
10-30V
≥10 mA
≥10 mA
≥10 mA
≥10 mA
≥10 mA
≥10 mA
400 mA
400 mA
400 mA
400 mA
400 mA
400 mA
≥2.4V
≥2.4V
≥2.4V
≥2.4V
≥2.4V
≥2.4V
≥ 10mA
≥ 10mA
≥ 10mA
≥ 10mA
≥ 10mA
≥ 10mA
500Hz
500Hz
500Hz
500Hz
300Hz
300Hz
≥15%
≥15%
≥15%
≥15%
≥15%
≥15%
≥10%
≥10%
≥10%
≥10%
≥10%
≥10%
.8mm (.03 in.)
.8mm (.03 in.)
1.0mm (.04 in)
1.0mm (.04 in)
1.5mm (.06 in)
1.5mm (.06 in)
PBTB
PBTB
PBTB
PBTB
PBTB
PBTB
Trogamid T
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
PNP
M
5
5
1,
1,
LED
8
Fixed Cable
x
x
1
30
30
x
LED
Fixed Cable
M
M
18
LED
NPN
BR
•
12
42
• –
38
BL
60
+
LOAD
LOAD
5
60 0
BR
BK
60
©Altech
+
Normally Open
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
BK
BL
–
Normally Open
33
PREVIOUS
HOME
NEXT
• 4mm, 5mm, and 6.5mm
diameter
• Economically Priced
• Non-connector models
feature polyurethane
(PUR) cables
• Carries
mark
DC - 3 WIRE
MINI METAL HOUSING
Cylindrical, 10-30V DC, 200mA
LED for Output Energized
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
Ø 4 Flush Mount
Sensing Distance
M5 Flush Mount
0.8mm (0.03 in.)
Cable or Connector Style Cat. No.
0.8mm (0.03 in.)
Cable
64
Cable
64
9980-1010
9980-1064
9980-2010
9980-2064
9980-1110
9980-1164
9980-2110
9980-2164
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
≤2V
≤2V
≤2V
≤2V
Max. Leakage Currrent
≤100 µA
≤100 µA
≤100 µA
≤100 µA
Switching Frequency
5000 Hz
5000 Hz
5000 Hz
5000 Hz
Hysterisis
Typ. 5%
Typ. 5%
Typ. 5%
Typ. 5%
≤10%
≤10%
≤10%
≤10%
.04mm (.003in.)
.04mm (.003in.)
PNP
NPN
Normally Open
Normally Closed
Normally Open
Normally Closed
Voltage Drop Across Sensor
Temperature Drift
Repeatability
.04mm (.003 in.)
Front Cap Material
.04mm (.003 in.)
PBTP
Housing Material
PBTP
Nickel Plated Brass
PBTB
Nickel Plated Brass
PBTB
Nickel Plated Brass
Nickel Plated Brass
M
5
x
LED
25
25
20
18
18
5
4
0,
Ø
LED
Fixed Cable
PUR 2m (6 ft. 6 in.).Supplied with Brass,
Nickel Plated (BN) locknuts for M5 model.
M
5
LED
Ø
LED
x
4
18
5
0,
x
38
38
19
8
1
x1
©Altech
M
8
M
34
23
18
19
64 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts for
M5 model.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
.5 mm =
1.0 mm =
3.5 mm =
4.0 mm =
5.0 mm =
6.5 mm =
8.0 mm =
.019in.
.04 in.
.13 in
.15 in.
.19 in.
.25 in.
.31 in.
FIND IT
Accessories
19.0 mm
20.0 mm
23.0 mm
25.0 mm
35.0 mm
40.0 mm
43.0 mm
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
= .74 in.
= .78 in
= .90 in.
= .94 in.
= 1.37 in.
= 1.57 in.
= 1.69 in.
This table converts
millimeters to inches in reference to
the illustrations
included in this
catalog
64 Connector
64 Connector
64 Connector
8000-5220 PVC, Straight
8000-5230 PVC, Right Angle, 2LED, PNP
8000-5240 PVC, Right Angle, 2LED, NPN
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more
cable information
Ø 6.5 Flush Mount
Ø 6.5 Non-Flush Mount
1.5mm (0.06 in.)
3.0mm (0.11 in.)
Mounting Brackets – see Pages 114-115
Cable
65
Cable
65
9961-1200
9961-1264
9961-1300
9961-1364
≤10%
≤10%
≤10%
≤10%
10V - 30V
10V - 30V
10V - 30V
10V - 30V
≤8 mA
≤8 mA
≤8 mA
≤8 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤10 µA
≤10 µA
≤10 µA
≤10 µA
2000 Hz
2000 Hz
2000 Hz
2000 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.15mm (.006in.)
.15mm (.006in.)
.15mm (.006in.)
.15mm (.006in.)
PBTB
PBTB
PBTB
PBTB
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cabl;e
purchased from Altech
Ø
PNP
NPN
5
6,
5
BR
+
40
Ø
5
6,
1
5
49 35
–
64 Connector
+
BR
• +
LOAD
BK
2/4
49 40
BL
Normally Open
1
BR
©Altech
+
BK
LOAD
• –
BL
64 Connector
LED
•
LOAD
Normally Open
LED
BR
BK
35
40
Fixed Cable
Fixed Cable
LED
LED
LOAD
2/4
BL • –
3
Normally Open
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
BK
BL
–
3
Normally Open
35
PREVIOUS
DC - 4 WIRE – COMPLEMENTARY
OUTPUTS (N.O. & N.C.)
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
HOME
• Carries
NEXT
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
mark
M12 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Cable
65
Cable
65
9962-6200
9962-6265
9962-6300
9962-6365
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤15 mA
≤15 mA
≤15 mA
≤15 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
PNP
(Complementary NO/NC)
NPN
(Complementary NO/NC)
Voltage Drop Across Sensor
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
2000 Hz
2000 Hz
1000 Hz
1000 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
.40mm (.016 in.)
.40mm (.016 in.)
PBTB
PBTB
Repeatability
.20mm (.008 in.)
Front Cap Material
PBTP
.20mm (.008 in.)
PBTP
M
12
x
M
1
12
x
1
4
60 4
6
LED
LED
5
60 0
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
36
©Altech
LED
12
12
M
M
7
80 0
54
6
LED
6
7 0
80 0
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
1.0 mm = .04 in.
6.0 mm = .23 in.
8.0 mm = .31 in.
10.0 mm = .39 in.
12.0 mm = .47 in.
18.0 mm = .70 in.
32.0 mm = 1.26 in.
42.0 mm= 1.65 in.
Accessories
44.0 mm
50.0 mm
51.0 mm
54.0 mm
60.0 mm
70.0 mm
80.0 mm
=
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
1.73 in.
1.96 in.
2.0 in.
2.12 in.
2.36 in.
2.75 in.
3.12 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
65 Connectors, 4PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
65 Connectors 8000-5280
PVC, Right Angle
Change last digit of connector number
for 5 meter cable
Refer to pages 116-121 for more cable information
M18 Flush Mount
Mounting Brackets – see Pages 114-115
M18 Non-Flush Mount
5mm (.2 in.)
8mm (.31 in.)
Cable
65
Cable
65
9964-6200
9964-6265
9964-6300
9964-6365
≤10%
≤10%
≤10%
≤10%
10V - 30V
10V - 30V
10V - 30V
10V - 30V
≤15 mA
≤15 mA
≤15 mA
≤15 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4 V
10 µA
10 µA
10µA
10µA
1000 Hz
1000 Hz
500 Hz
500 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.5mm (.02 in.)
.5mm (.02 in.)
.8mm (.031 in.)
.8mm (.031 in.)
PBTB
PBTB
PBTB
PBTB
Note: Sensor dimensions in mm.
Wiring Diagrams
M
M
18
18
x
x
1
1
Note: Wire colors are applicable to cable
purchased from Altech
PNP
LED
Cable Connector
BR +
60
60
42
50
8
LED
BK (N.O.)
WH (N.C.)
LOAD
•
–
BL
•
M
M
PNP
18
18
x
x
1
1
65 Connector
LED
BR
8
LED
1
+
4 BK(N.O.)
LOAD
©Altech
80
3
(N.C.)
•
BL
–
LOAD
WHT
10
10
80
2
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
37
PREVIOUS
DC - 3 WIRE – EXTENDED
TEMPERATURE RANGE
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
HOME
NEXT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range:
-40 to 100°C
(104 to 212°F)
• Carries
mark
M12 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
PNP
NPN
Normally Open
FIND IT
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Cable
65
Cable
65
9962-6010
9962-6065
9962-6110
9962-6165
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
2000 Hz
2000 Hz
1000 Hz
1000 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
.40mm (.016 in.)
.40mm (.016 in.)
PBTB
PBTB
.20mm (.008 in.)
Front Cap Material
PBTP
PBTP
M
M
12
12
x
x
LED
1
1
6
LED
40
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
.20mm (.008 in.)
34
Repeatability
M
x
12
12
M
1
LED
50
60
60
©Altech
34
6
LED
4
50 0
38
1
x
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Accessories
Metric/in. Conversion Table
1.0 mm
6.0 mm
8.0 mm
12.0 mm
18.0 mm
=
=
=
=
=
.04 in.
.23 in.
.31 in.
.47 in.
.70 in.
FIND IT
32.0 mm
34.0 mm
40.0 mm
50.0 mm
51.0 mm
60.0 mm
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
1.23 in.
1.31 in.
1.39 in.
1.47 in.
1.59 in.
2.36 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
65 Connector
65 Connector
65 Connector
65 Connector
8000-5110
8000-5120
8000-5150
8000-5160
PVC, Straight
PVC, Right Angle
PVC, Right Angle, 2LED, NPN
PVC, Right Angle, 2LED, PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M18 Flush Mount
M18 Non-Flush Mount
5mm (.20 in.)
8mm (.31 in.)
Mounting Brackets – see Pages 114-115
Cable
65
Cable
65
9964-6010
9964-6065
9964-6110
9964-6165
≤10%
≤10%
≤10%
≤10%
10V - 30V
10V - 30V
10V - 30V
10V - 30V
≤10 mA
≤10 mA
≤25 mA
≤25 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
10 µA
10 µA
10µA
10µA
1000 Hz
1000 Hz
500 Hz
500 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.50mm (.02 in.)
.50mm (.02 in.)
.80mm (.03 in.)
.80mm (.03 in.)
PBTB
PBTB
PBTB
PBTB
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
M
M
PNP
18
18
x
x
1
1
LED
LED
Fixed Cable
+
8
BR
LOAD
40
32
40
BK
• –
BL
Normally Open
M
18
18
M
65 Connector
x
x
1
1
LED
BR +
LED
1
4 BK
32
M
12
1
12
x
x
1
©Altech
5
60 1
M
4
5 0
60 1
8
LOAD
2
3
•
BL
–
Normally Open
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
39
PREVIOUS
DC - 3 WIRE – WELD IMMUNE
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
HOME
NEXT
• Circuitry that protects for
electro-magnetic interference
• Flush models have teflon
ceramic coatings to protect
for weld slag
• Carries
mark
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13)
Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M12 Flush Mount
Sensing Distance
2mm (.08 in.)
Cable or Connector Style Cat. No.
PNP
NPN
Normally Open
M12 Non-Flush Mount
Cable
4mm (.16 in.)
45
9962-5840
9962-5845
Cable
65
9962-5900
9962-5965
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
15 Hz
15 Hz
15Hz
15 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤10%
Temperature Drift
Repeatability
≤10%
.20mm (.008 in.)
Front Cap Material
Housing Material
.20mm (.008 in.)
≤10%
≤10%
.40mm (.016 in.)
.40mm (.016 in.)
Teflon
Teflon
PBTB
Teflon Plated Brass
Teflon Plated Brass
Nickel Plated Brass
PBTB
Nickel Plated Brass
M
x
12
12
M
1
x
1
LED
10
50
50
6
LED
10
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
M
x
12
12
M
1
x
1
70
6
LED
LED
40
©Altech
10
10
70
45/65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
1.0 mm
6.0 mm
8.0 mm
10.0 mm
12.0 mm
=
=
=
=
=
Accessories
50.0 mm
52.0 mm
60.0 mm
70.0 mm
80.0 mm
.04 in.
.23 in.
.31 in.
.39 in.
.47 in.
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
1.47 in.
2.04 in.
2.36 in.
2.75 in.
3.12 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
45/65 Connector 8000-5110
45/65 Connector 8000-5120
45/65 Connector 8000-5150
45/65 Connector 8000-5160
PVC, Straight
PVC, Right Angle
PVC, Right Angle, 2LED, NPN
PVC, Right Angle, 2LED, PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M18 Flush Mount
M18 Non-Flush Mount
5mm (.20 in.)
8mm (.31 in.)
Cable
45
Cable
65
9964-5840
9964-5845
9964-5900
9964-5965
≤10%
≤10%
≤10%
≤10%
10V - 30V
10V - 30V
10V - 30V
10V - 30V
≤10 mA
≤10 mA
≤10 mA
≤10 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
10 µA
10 µA
10µA
10µA
15 Hz
15 Hz
15 Hz
15 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.50mm (.02 in.)
.50mm (.02 in.)
.80mm (.03 in.)
.80mm (.03 in.)
Teflon
Teflon
PBTB
PBTB
Teflon Plated Brass
Teflon Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Mounting Brackets – see Pages 114-115
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
M
18
PNP
x
1
M
18
x
1
Fixed Cable
LED
BR
+
8
LED
BK
Normally Open
10
10
60
60
LOAD
• –
BL
M
x
18
18
M
1
x
1
65 Connector
BR +
LED
4 BK
8
LED
1
LOAD
©Altech
3
•
BL
–
Normally Open
10
10
80
80
2
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
41
PREVIOUS
DC - 3 WIRE – WELD IMMUNE
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
• Flush models have teflon
ceramic coatings to protect
for weld slag
• Carries
mark
Cable or Connector Style Cat. No.
PNP
NPN
NEXT
• Circuitry that protects for
electro-magnetic interference
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M30 Flush Mount
M30 Non-Flush Mount
10mm (.39 in.)
15mm (.59 in.)
Sensing Distance
Normally Open
HOME
Cable
45/65
9966-5840
9966-5845
Cable
65
9966-5900
9966-5965
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤10 µA
≤10 µA
≤10 µA
≤10 µA
Switching Frequency
15 Hz
15 Hz
15 Hz
15Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤10%
Temperature Drift
Repeatability
≤10%
1.0mm (.039 in.)
Front Cap Material
1.0mm (.039 in.)
Teflon
Housing Material
Teflon
Teflon Plated Brass
≤10%
≤10%
1.5mm (.059 in.)
1.5mm (.059 in.)
PBTB
Teflon Plated Brass
PBTB
Nickel Plated Brass
Nickel Plated Brass
Note: Sensor dimensions in mm.
M
M
30
30
x
x
1,
5
5
1,
LED
60
12
LED
10
10
60
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
M
30
M
x
30
1,
x
5
1,
5
LED
LED
10
10
80
80
12
45/65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
42
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
1.5 mm = .06 in.
10.0 mm = .39 in.
12.0 mm = .47 in.
30.0 mm =1.20 in.
60.0 mm = 2.36 in.
80.0 mm= 3.15 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
Accessories
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
45/65 Connector 8000-5110
45/65 Connector 8000-5120
45/65 Connector 8000-5150
45/65 Connector 8000-5160
PVC, Straight
PVC, Right Angle
PVC, Right Angle, 2LED, NPN
PVC, Right Angle, 2LED, PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more
cable information
Mounting Brackets – see Pages 114-115
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
PNP
Fixed Cable
BR
+
BK
LOAD
• –
BL
Normally Open
65 Connector
BR +
4 BK
1
LOAD
2
3
•
BL
–
Normally Open
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
43
PREVIOUS
Cable or Connector Style Cat. No.
NEXT
• Output voltage proportional to
target distance
• Ideal for determining position
information
• Excellent linearity ± 3%
• Shielded cable ouputs on
cable models
• Carries
mark
DC ANALOG SENSORS
Cylindrical,Threaded
Brass, Nickel Plated (BN),
18-30V DC
Analog Output 1V - 9V M12, M18, M30
M30 4 Bit Digital & Analog Output
Sensing Distance
HOME
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6,
12, 13) Protection
• Short Circuit Protection
• Overload Protection
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M12 Flush Mount
M18 Flush Mount
0.5mm (.02 in.) to 2.5mm (0.1 in.)
1mm (.04 in.) to 4mm (.16 in.)
Cable
65
Cable
65
9914-0800
9914-0865
9914-0900
9914-0965
Voltage Range
18V-30V
18V - 30V
18V - 30V
18V - 30V
Supply Current
≤10 mA
≤10 mA
≤10 mA
≤10 mA
5 mA
5 mA
5 mA
5 mA
Max. Switching Frequency
100 Hz
100 Hz
100 Hz
100 Hz
Temperature Drift
±0.3V
Max. Load Current
±0.3V
±0.3V
±0.3V
Repeatability
1%
1%
1%
1%
Front Cap Material
PBTP
PBTP
PBTB
PBTB
1–9V DC
1–9V DC
1–9V DC
1–9V DC
Output Voltage Range
M
1
18
x
M
12
x
7
80 0
7
80 0
1
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
x
18
12
M
M
x
1
44
©Altech
10 80
0
10
0
80
1
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.0 mm
1.5 mm
10.0 mm
12.0 mm
18.0 mm
30.0 mm
= .04 in.
= .06 in.
= .40 in.
= .47 in.
= .70 in.
=1.20 in.
58.0 mm = 2.28 In.
70.0 mm = 2.75 in.
80.0 mm = 3.12 in.
100.0mm = 3.94 in.
FIND IT
Accessories
This table
converts millimeters to inches in
reference to the
illustrations
included on these
pages
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
65 Connectors, 4PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
65 Connectors 8000-5280
PVC, Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M30 Non-Flush Mount
7mm (.28 in.) to 14mm (.55 in.)
Cable
Cable
65
9914-1000
9914-0500
9914-0565
18V - 30V
18V - 30V
18V - 30V
≤10 mA
≤10 mA
≤10 mA
5 mA
5 mA
5 mA
30 Hz
30 Hz
30 Hz
±0.3V
±0.3V
±0.3V
1%
1%
1%
PBTB
PBTB
PBTB
1–9V DC & 4 Bit Digital
1–9V DC
1–9V DC
Note: Sensor dimensions in mm.
The analog output voltage can be digitized
by the 8100-2100 switching unit and
8100-2400/2500 modules.
(Separate Accessory items - refer to
pages 125 & 126 for more information.)
Mounting Brackets – see Pages 114-115
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
Fixed Cable M12, M18, M30
+
BR
M
30
x
WHT
5
1,
•
LOAD
•
BL
–
12
SHIELD
WIRE
Fixed Cable M30
80
58
7 CONDUCTOR CABLE
BR
+
GREY
YEL
PNK
GR
4 BIT DIG.
OUTPUT
WHT
•
LOAD
•
–
BL
SHIELD
WIRE
65CN M12, M18, M30
BR +
1
4 BK
LOAD
•
2
BL –
3
WHT
•
Pin 2 connected internally
to Pin 3. (Can be used as shield
with shielded cable)
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
45
PREVIOUS
DC - 3WIRE
EXTENDED RANGE PLUS
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
PNP
NPN
Normally Open
NEXT
FIND IT
• Up to 3 times the sensing distance • IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Sensing ranges from 3mm (.12 in.) to
• Ideal for applications where large
40mm (1.57 in.)
sensors will not fit
• Short Circuit Protection
• Carries
mark
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M8 Flush Mount
M8 Non-Flush Mount
3mm (0.1 in.)
6mm (0.2 in.)
Sensing distance
Cable or Connector Style Cat. No.
HOME
Cable
64
65
Cable
64
65
9981-5000
9981-5064
9981-5065
9981-5200
9981-5264
9981-5265
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤20%
≤20%
≤20
≤20%
≤20%
≤20%
Voltage Range
10-30V
10-30V
10-30V
10-30V
10-30V
10-30V
Supply Current
≤20mA
≤20mA
≤20mA
≤20mA
≤20mA
≤20mA
Max. Load Current
200mA
200mA
200mA
200mA
200mA
200mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤100µA
≤100µA
≤100µA
≤100µA
≤100µA
≤100µA
Switching Frequency
500Hz
1000Hz
1000Hz
1000Hz
500Hz
500Hz
Hysterisis
10%
10%
10%
10%
10%
10%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
Housing Material
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
.15mm (.005 in.)
.15mm (.005 in.)
.15mm (.005 in.)
.3mm (.01 in.)
.3mm (.01 in.)
.3mm (.01 in.)
Repeatability
M
M
8
8
x
LED
x
45
45
4
1
1
LED
Fixed Cable
PVC 2m (6 ft. 6 in.). Supplied with
Brass, Nickel Plated (BN) locknuts.
8
x
x
1
5
64 8
8
M
M
5
60 4
46
46
4
1
1
x
x
LED
8
8
LED
M
M
64 Connector
3-pin, Pico style, 8mm (.31 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
1
8
x
12
1
1
x
x
44
70 62
M
4
66 58 4
4
1
1
LED
x
12
©Altech
8
LED
M
46
M
M
65 Style Connectors
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.0 mm
4.0 mm
6.0 mm
8.0 mm
12.0 mm
40.0 mm
44.0 mm
45.0 mm
50.0 mm
M12 Flush Mount
=
=
=
=
=
=
=
=
=
Accessories
52.0 mm
54.0 mm
56.0 mm
58.0 mm
60.0 mm
62.0mm
66.0 mm
70.0 mm
.04 in.
.16 in
.23 in.
.31 in.
.47 in.
1.39 in.
1.73 in.
1.77 in.
1.97 in.
=
=
=
=
=
=
=
=
2.04 in.
2.12 in.
2.20 in.
2.28 in.
2.36 in.
2.44 in.
2.60 in.
2.75 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
M12 Non-Flush Mount
6mm (0.2 in.)
FIND IT
10mm (0.4 in.)
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
64 Connector 8000-5220 PVC, Straight
64 Connector 8000-5230 PVC, Right Angle, 2LED,PNP
64 Connector 8000-5240 PVC, Right Anglr, 2 LED, NPN
65 Connector 8000-5110 PVC, Straight
65 Connector 8000-5120 PVC, Right Angle
65 Connector 8000-5150 PVC, Right Angle, 2LED NPN
65 Connector 8000-5160 PVC, Right Angle, 2LED PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
Cable
65
Cable
65
9982-5000
9982-5065
9982-5200
9982-5265
Flush Installation
Non-Flush Installation
≤20%
≤20%
≤20%
10-30V
10-30V
10-30V
≤20mA
≤20mA
≤20mA
≤20mA
200mA
200mA
200mA
200mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤100µA
≤100µA
≤100µA
≤100µA
800Hz
800Hz
400Hz
400Hz
10%
10%
10%
10%
≤10%
≤10%
≤10%
≤10%
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
.3mm (.01 in.)
.3mm (.01 in.)
.5mm (.02 in.)
.5mm (.02 in.)
Note: Sensor dimensions in mm.
d ≥d d
≥0.2d
≥2d
Metal Material
General Mounting – You must maintain minimum distance
between adjacent and opposite sensors in addition to non-target
metals as specified in the drawings above. Flush mount sensors
must extend at least 0.2 times the sensor diameter above the
adjacent metal housing. Non-flush mount sensors must extend a
distance greater than the sensing distance (Sn). Please contact
Altech for any installation assistance
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
PNP
M
M
12
12
1
1
Fixed Cable
x
LED
x
LED
d
≥Sn
≤20%
10-30V
≥3 x Sn
≥2d
+
6
BR
4
50 0
4
56 0
BK
LOAD
• –
BL
Normally Open
64 Connector
1
+
BR
BK
2/4
LOAD
BL • –
3
Normally Open
M
12
12
M
65 Connector
x
LED
M
1
4 BK
LOAD
2
3
•
BL
–
66
12
1
1
x
x
12
5
60 2
40
4
58 0
6
1
M
©Altech
BR +
1
x
LED
Normally Open
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
47
PREVIOUS
DC - 3WIRE
EXTENDED RANGE PLUS
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
HOME
NEXT
• Up to 3 times the sensing distance
• Ideal for applications where large
sensors will not fit
• Carries
mark
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Sensing ranges from 3mm (.12 in.) to
40mm (1.57 in.)
• Short Circuit Protection
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M18 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
PNP
NPN
M18 Non-Flush Mount
12mm (0.4 in.)
Normally Open
20mm (0.8 in.)
Cable
65
Cable
65
9984-5000
9984-5065
9984-5200
9984-5265
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤20%
≤20%
≤20%
≤20%
Voltage Range
10V-30V
10V - 30V
10V - 30V
10V - 30V
Supply Current
≤20 mA
≤20 mA
≤20 mA
≤20 mA
Max. Load Current
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤100 µA
≤100 µA
≤100 µA
≤100 µA
Switching Frequency
500 Hz
500 Hz
200 Hz
200 Hz
Hysterisis
≤10%
≤10%
≤10%
≤10%
Temperature Drift
≤10%
≤10%
≤10%
Housing Material
Nickel Plated Brass
Voltage Drop Across Sensor
Repeatability
Nickel Plated Brass
0.6mm (.02 in.)
0.6mm (.02 in.)
M
x
60
40
4
50 0
10
1
1
x
M
x
x
x
1
1
6
74 0
40
12
x
64
M
4
50 0
10
1
1
LED
18
18
12
©Altech
18
18
M
48
1mm (.04 in.)
LED
M
LED
65 Style Connectors
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Nickel Plated Brass
1mm (.04 in.)
M
LED
Fixed Cable
PVC 2m (6 ft. 6 in.). Supplied with
Brass, Nickel Plated (BN) locknuts.
≤10%
Nickel Plated Brass
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Accessories
Metric/in. Conversion Table
1.0 mm
4.0 mm
6.0 mm
8.0 mm
12.0 mm
40.0 mm
44.0 mm
45.0 mm
50.0 mm
=
=
=
=
=
=
=
=
=
52.0 mm
54.0 mm
56.0 mm
58.0 mm
60.0 mm
62.0mm
66.0 mm
70.0 mm
.04 in.
.16 in
.23 in.
.31 in.
.47 in.
1.57 in.
1.73 in.
1.77 in.
1.97 in.
FIND IT
=
=
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
2.04 in.
2.12 in.
2.20 in.
2.28 in.
2.36 in.
2.44 in.
2.60 in.
2.75 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
M30 Flush Mount
M30 Non-Flush Mount
22mm (0.9 in.)
40mm (1.57 in.)
Cable
65
Cable
65
9986-5000
9986-5065
9986-5200
9986-5265
65 Connector
65 Connector
65 Connector
65 Connector
8000-5110
8000-5120
8000-5150
8000-5160
PVC, Straight
PVC, Right Angle
PVC, Right Angle, 2LED NPN
PVC, Right Angle, 2LED PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
Flush Installation
Non-Flush Installation
≤20%
≤20%
≤20%
10V - 30V
10V - 30V
10V - 30V
≤20 mA
≤20 mA
≤20 mA
≤20 mA
200 mA
200 mA
200 mA
200 mA
≤2.4V
≤2.4V
≤2.4V
≤2.04V
100 µA
100 µA
100µA
100µA
300 Hz
300 Hz
100 Hz
100 Hz
≤10%
≤10%
≤10%
≤15%
≤10%
≤10%
≤10%
Nickel Plated Brass
1.1mm (.045 in.)
Nickel Plated Brass
d ≥d d
≥2d
Metal Material
General Mounting – You must maintain minimum distance
between adjacent and opposite sensors in addition to non-target
metals as specified in the drawings above. Flush mount sensors
must extend at least 0.2 times the sensor diameter above the
adjacent metal housing. Non-flush mount sensors must extend a
distance greater than the sensing distance (Sn). Please contact
Altech for any installation assistance
≤10%
Nickel Plated Brass
1.1mm (.045 in.)
≥0.2d
d
≥Sn
≤20%
10V - 30V
≥3 x Sn
≥2d
Nickel Plated Brass
2mm (.078 in.)
2mm (.078 in.)
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
M
PNP
x
30
30
M
1.
x
5
1.
LED
5
LED
Fixed Cable
BR
+
70
Normally Open
M
M
30
30
x
x
5
1.
1.
LED
LOAD
• –
BL
50
5
60 0
10
BK
5
LED
65 Connector
BR +
1
4 BK
3
•
BL
–
Normally Open
84
1
70
50
x
1
74
12
x
©Altech
M
12
5
60 0
M
10
LOAD
2
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
49
PREVIOUS
DC - 2 WIRE NAMUR
Brass, Nickel Plated (BN),
and Plastic (TROGAMID-T)
Cylindrical,Threaded
HOME
NEXT
• Low energy device
• Operates in hazardous
areas with external
amplifier
• Meets NAMUR regulations
and DIN 19234 specifications
• Carries
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Reverse Polarity Protection
• Plastic and Metal Housing according to NAMUR
Regulations and DIN 19234
• Temperature Range: -25 to 70°C (-13 to 158°F)
(For extended temperature models of -40°C to
+125°C, consult Altech.)
mark
M8 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
Nickel Plated Brass (BN)
M8 Non-Flush Mount
1mm (.04 in.)
2mm (.08 in.)
Cable
65
Cable
65
9932-0100
9932-0165
9932-0200
9932-0265
Plastic (TROGAMID T)
9932-1600
≤5%
≤5%
≤15%
≤5%
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
Output Current ( with target detection)
0.5 mA
0.5 mA
0.5 mA
0.5 mA
Output Current ( no target detection)
3.5 mA
3.5 mA
3.5 mA
3.5 mA
2000 0Hz
2000 Hz
1000 Hz
1000 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
.1mm (.004 in.)
.1mm (.004 in.)
.2mm (.008 in.)
.2mm (.008 in.)
Ripple Voltage
Switching Frequency
Repeatability
Front Cap Material
PBTP (Metal Housing)
PBTP (Metal Housing)
PBTP (Metal Housing)
M
M
8
8
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Non-metallic
locknuts for M8 and Brass, Nickel Plated
(BN) locknuts for M12 through M30.
PBTP (Metal Housing)
x
x
30
5
1
1
30
25
Voltage Range (supplied by
Pulsotronic 8100-2200 Unit)
M
28
23
5
1
1
x
x
8
8
M
50
12
50
M
x
1
1
x
©Altech
12
50
M
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with non-metallic locknuts for M8 and Brass,
Nickel Plated (BN) locknuts for M12 through
M30.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.0 mm
5.0 mm
6.0 mm
8.0 mm
12.0 mm
23.0mm
=
=
=
=
=
=
.04 in.
.20 in.
.23 in.
.31 in.
.47 in.
.91 in.
24.0 mm
25.0 mm
28.0 mm
30.0 mm
40.0 mm
50.0 mm
FIND IT
Accessories
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
.94 in.
1.0 in.
1.16 in
1.20 in.
1.57 in.
1.97 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
65 Connectors, 4 PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
65 Connector 8000-5280
PVC Right Angle
Channge last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more
cable information
M12 Flush Mount
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Cable
65
Cable
65
9932-0300
9932-0365
9932-0400
9932-0465
9932-1100
9932-1000
≤15%
≤5%
≤5%
≤5%
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
0.5 mA
0.5 mA
0.5 mA
0.5 mA
3.5 mA
3.5 mA
3.5 mA
3.5 mA
2000 Hz
2000 Hz
1000 Hz
1000 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.2mm (.008 in.)
.2mm (.008 in.)
.4mm (.016 in.)
.4mm (.016 in.)
PBTP (Metal Housing)
Remote Amplifier –
Use 8100-2200, see page 123
PBTP (Metal Housing)
PBTP (Metal Housing)
Mounting Brackets – see Pages 114-115
PBTP (Metal Housing)
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
1
1
x
x
12
12
M
M
Fixed Cable
BR
+
24
30
6
Remote
Amplifier
BL
–
M
12
1
12
x
M
65 Connector
x
1
BR
1
+
4
24
Amplifier
3
40
2
12
50
M
3
4 0
50 0
6
Remote
WHT –
x
1
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
51
PREVIOUS
DC - 2 WIRE NAMUR
Brass, Nickel Plated (BN),
and Plastic (TROGAMID-T)
Cylindrical,Threaded
HOME
NEXT
• Low energy device
• Operates in hazardous
areas with external
amplifier
• Meets NAMUR regulations
and DIN 19234 specifications
• Carries
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Reverse Polarity Protection
• Plastic and Metal Housing according to NAMUR
Regulations and DIN 19234
• Temperature Range: -25 to 70°C (-13 to 158°F)
mark
M18 Flush Mount
Sensing Distance
M18 Non-Flush Mount
5mm (.20 in.)
Cable or Connector Style Cat. No.
8mm (.31 in.)
Cable
65
Cable
65
Nickel Plated Brass (BN)
9932-0500
9932-0565
9932-0600
9932-0665
Plastic (TROGAMID T)
9932-1300
Voltage Range (supplied by
Pulsotronic 8100-2200 Unit)
9932-1200
≤5%
≤5%
≤5%
≤5%
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
0.5 mA
0.5 mA
0.5 mA
0.5 mA
Ripple Voltage
Output Current ( with target detection)
Output Current ( no target detection)
3,5 mA
3.5 mA
3.5 mA
3.5 mA
1000 0Hz
1000 Hz
500 Hz
500 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
Switching Frequency
.5mm (.02 in.)
PBTP (Metal Housing)
.5mm (.02 in.)
.8mm (.03 in.)
PBTP (Metal Housing)
.8mm (.03 in.)
PBTP (Metal Housing)
M
x
18
18
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
PBTP (Metal Housing)
30
8
1
1
x
30
Front Cap Material
22
Repeatability
M
22
40
x
1
1
50
12
x
©Altech
M
12
52
3
4 0
50 0
8
1
1
x
x
18
18
M
M
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.0 mm
1.5 mm
8.0 mm
12.0 mm
18.0 mm
22.0 mm
=
=
=
=
=
=
.04 in.
.06 in.
.31 in.
.47 in.
.70 in.
.86 in.
28.0 mm
30.0 mm
40.0 mm
50.0 mm
51.0 mm
60.0 mm
FIND IT
Accessories
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
1.16 in
1.20 in.
1.57 in.
1.96 in.
2.00 in.
2.36 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
65 Connectors, 4 PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
65 Connector 8000-5280
PVC Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to page s 116-121 for more
cable information
M30 Flush Mount
M30 Non-Flush Mount
10mm (.39 in.)
15mm (.59 in.)
Remote Amplifier –
Use 8100-2200, see page 123
Cable
65
Cable
65
9932-0700
9932-0765
9932-0800
9932-0865
9932-1500
9932-1400
Mounting Brackets – see Pages 114-115
≤5%
≤5%
≤5%
≤5%
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
0.5 mA
0.5 mA
0.5 mA
0.5 mA
3.5 mA
3.5 mA
3.5 mA
3.5 mA
500 Hz
500 Hz
300 Hz
300 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.1mm (.039 in.)
PBTP (Metal Housing)
.1mm (.039 in.)
PBTP (Metal Housing)
1.5mm (.059 in.)
1.5mm (.059 in.)
PBTP (Metal Housing)
PBTP (Metal Housing)
Note: Sensor dimensions in mm.
Wiring Diagrams
x
30
30
M
M
Note: Wire colors are applicable to cable
purchased from Altech
1,
x
5
1,
5
Fixed Cable
BR
+
BL
–
40
28
40
12
Remote
Amplifier
M
x
30
30
M
1,
x
5
5
1,
65 Connector
BR
1
+
4
Remote
12
Amplifier
1
4
5 0
60 1
1
x
4
5 0
60 1
x
12
©Altech
12
M
M
2
3
WHT –
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
53
PREVIOUS
HOME
NEXT
• 2 Wire devices reduce wiring
requirements
DC - 2 WIRE SENSORS
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
M12 – 5-30V DC, 100mA
M18, M30 – 10-55V DC, 200 mA
1 LED for Output Energized
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Reverse Polarity Protection
• Temperature Range: -25 to 70°C (-13 to 158°F)
• Economically Priced
• Carries
FIND IT
mark
M12 Flush Mount
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Sensing distance
M18 Flush Mount
5mm (0.2 in.)
Cable or Connector Style Cat. No.
Cable
65
Cable
65
Cable
Normally Open
9962-5600
9962-5665
9962-5700
9962-5765
9964-5400
Normally Closed
Ripple Voltage
≤10%
≤10%
≤10%
≤10%
≤10%
Voltage Range
5V-30V
5V-30V
5V-30V
5V-30V
10V-55V
Supply Current
≤3mA
≤3mA
≤3mA
≤3mA
≤5mA
Max. Load Current
100mA
100mA
100mA
100mA
200mA
≤6.5V
≤5V
≤5V
≤5V
≤5V
≤0.5mA
≤0.5mA
≤0.5mA
≤0.5mA
Switching Frequency
500Hz
500Hz
500Hz
500Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
.20mm (.008 in.)
.20mm (.008 in.)
.40mm (.016 in.)
.40mm (.016 in.)
.40mm (.016 in.)
PBTP
PBTP
PBTP
PBTP
Voltage Drop Across Sensor
Max. Leakage Currrent
Front Cap Material
x
1
1
1
5
60 0
6
29
45
35
45
M
12
x
x
LED
1
1
©Altech
18
x
x
LED
12
54
M
12
12
LED
LED
M
50
34
6
LED
4
5 0
60 0
65 Style Connector
4-pin, Micro style, 12mm (.47 in.)
supplied with Brass, Nickel Plated
(BN) locknuts.
PBTP
M
M
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
1000Hz
60
Repeatability
≤1.5mA
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.5 mm
2.0 mm
4.0 mm
5.0 mm
6.0 mm
8.0 mm
10.0 mm
12.0 mm
15.0 mm
18.0 mm
=
=
=
=
=
=
=
=
=
=
.06 in.
.08 in.
.16 in
.20 in.
.23 in.
.31 in.
.39 in.
.47 in.
.59 in.
.70 in.
Accessories
23.0 mm
28.0 mm
30.0 mm
32.0 mm
34.0 mm
40.0 mm
50.0 mm
51.0 mm
60.0 mm
80.0 mm
=
=
=
=
=
=
=
=
=
=
.08 in.
1.10 in
1.18 in.
1.26 in.
1.34 in.
1.57 in.
1.97 in.
2.01 in.
2.36 in.
3.12 in.
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
10mm (.39 in.)
65 Connector
65 Connector
8000-5110 PVC, Straight
8000-5120 PVC, Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M18 Non-Flush Mount M30 Flush Mount M30 Non-Flush Mount
8mm (.31 in.)
FIND IT
Mounting Brackets – see Pages 114-115
15mm (.59 in.)
Cable
Cable
Cable
9964-5500
9966-5400
9966-5500
≤10%
≤10%
≤10%
10V-55V
10V-55V
10V-55V
≤5mA
≤5mA
≤5mA
200mA
200mA
200mA
≤6.5V
≤6.5V
≤6.5V
≤1.5mA
≤1.5mA
≤1.5mA
500Hz
500Hz
300Hz
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
.80mm (.03 in.)
1mm (.039 in.)
1.5mm (.059 in.)
PBTP
PBTP
PBTP
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
M
M
M
x
x
5
5
1,
1,
1
Fixed Cable
30
x
30
18
LED
LED
LED
BR
+
38
BL
–
60
5
60 0
60
12
42
8
LOAD
65 Connector
BR
1
4
2
3
+
LOAD
BLK –
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
55
PREVIOUS
AC - 2 WIRE
STANDARD SERIES
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
90-250V AC, 180 mA,
1 LED for Output Energized
HOME
NEXT
FIND IT
• Most complete range of Fixed Cable
and Quick Disconnect Styles
• Available in normally open (N.O.)
and normally closed (N.C.) output
configuration
• This series features the 360° LED viewing connector type "67"
• Carries
mark
• IEC (529) IP67 (NEMA 1, 3, 4, 6,
12, 13) Protection
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M12 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
Normally Open
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Cable
62
66/67
68
Cable
62
66/67
68
9952-0500
9952-0562
9952-0566
9952-0568
9952-0400
9952-0462
9952-0466
9952-0468
9952-0567
Normally Closed
9952-0900
9952-0467
9952-0966
9952-0968
9952-0800
9952-0866
9952-0967
Voltage Range
Operating Frequency
Supply Current
Max. Load Current
Voltage Drop Across Sensor
Max. Leakage Currrent
Short Term Current (20ms 1Hz)
Switching Frequency
Hysterisis
Temperature Drift
Repeatability
Front Cap Material
90V-250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
180 mA
100 mA
180 mA
180 mA
180 mA
180 mA
180 mA
180 mA
≤8V
≤8V
≤8V
≤8V
≤8V
≤8V
≤8V
≤8V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
1A
1A
1A
1A
1A
1A
1A
1A
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.2mm (.008in.)
.2mm (.008in.)
.2mm (.008in.)
.2mm (.008in.)
PBTP
PBTP
PBTP
PBTP
≤1.5mA/110V ≤1.5mA/110V
.4mm (.016in.) .4mm (.0016in.) .4mm (.016in.) .4mm (.016in.)
PBTB
PBTB
PBTB
PBTB
M
1
1
x
x
12
12
M
6
LED
LED
60
44
5
60 0
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
9952-0868
9952-0867
M
M
12
12
x
x
1
1
LED
LED
27
27
91
91
54
54
6
62 Style Connector
3-pin, Mini style, 25mm (1.0 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
M
1
x
1
LED (66/68 CN)
x
12
LED (66/68 CN)
12
M
56
10
10
26
26
LED (67 CN)
34
60
40
6
LED (67 CN)
60
66/67/68 Style Connectors
The 66/67 connectors are 4-pin,
(68 connector, 3-pin), Micro style,
12mm (.47 in.) supplied with Brass,
Nickel Plated (BN) locknuts.
The 67 Connector is clear, offering
360° LED viewing.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Accessories
Metric/in. Conversion Table
1.0 mm
5.0 mm
6.0 mm
8.0 mm
12.0 mm
23.0 mm
28.0 mm
= .04 in.
= .20 in.
= .23 in.
= .31 in.
= .47 in.
= .90 in.
=1.10 in.
FIND IT
29.0 mm
34.0 mm
35.0 mm
40.0 mm
43.0 mm
50.0 mm
60.0 mm
=
=
=
=
=
=
=
2 meter (6 ft. 6 in.) AC Cable Assemblies
for Quick Disconnect Sensors
1.14 in.
1.34 in.
1.37 in.
1.57 in.
1.69 in.
1.47 in.
2.36 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
62 Connector 8000-5030
66/67 Connector 8000-5060
66/67 Connector 8000-5070
68 Connector 8000-5130
68 Connector 8000-5140
PVC, Straight
PVC, Right Angle
PVC, Straight
PVC Straight
Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M18 Flush Mount
M18 Non-Flush Mount
5mm (0.2 in.)
8mm (.31 in.)
Cable
62
66/67
68
Cable
62
9954-2200
9954-2262
9954-2266
9954-2268
9954-1900
9954-1962
9954-2267
9954-2600
Mounting Brackets – see Pages 114-115
66/67
68
9954-1966
9954-1968
9954-1967
9954-2666
9954-2668
9954-2500
9954-2568
9954-2667
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
5 mA
180 mA
180 mA
180 mA
180 mA
180 mA
180 mA
180 mA
180 mA
≤8V
≤8V
≤8V
≤8V
≤8V
≤8V
≤8V
≤8V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤3mA/220V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
1A
1A
1A
1A
1A
1A
1A
1A
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.5mm (.02in.)
.5mm (.02in.)
.5mm (.02in.)
.5mm (.02in.)
.8mm (.031in.)
.8mm (.031in.)
.8mm (.031in.)
.8mm (.031in.)
PBTB
PBTB
PBTB
PBTB
PBTB
PBTB
PBTB
PBTB
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
Note: Sensor dimensions in mm.
Fixed Cable
Fixed Cable
BR
BR
M
M
18
18
x
x
1
1
BL LOAD
BL LOAD
Yellow/GRN
LED
LED
8
Normally Closed
60
42
5
60 0
Yellow/GRN
Normally Open
62 Connector
1
GRN
WHT
3
2
M
M
18
18
BLK LOAD
x
x
1
1
LED
Normally Open
91
27
91
66/67 Connector
Yell/GRN 4
3
BL
10
10
26
26
27
54
54
8
LED
1
66/67 Connector
Yell/GRN 4
BL
2
BLK LOAD
BLK
Normally Open
Normally Closed
M
1
1
x
x
18
18
LED (66/68 CN)
M
LED (66/68 CN)
68 Connector
LED (67 CN)
68 Connector
3
60 2
40
8
Red/WHT
60
2
1
LOAD
LED (67 CN)
3
2 Red
3
GRN
Red/WHT
2 Red
3
LOAD
1
Normally Open
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
GRN
LOAD
1
Normally Closed
57
PREVIOUS
HOME
NEXT
FIND IT
• Most complete range of Fixed Cable
and Quick Disconnect Styles
• Available in normally open (N.O.)
and normally closed (N.C.) output
configuration
• This series features the 360° LED viewing connector type "67"
• Carries
mark
AC - 2 WIRE
STANDARD SERIES
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
90-250V AC, 180 mA,
1 LED for Output Energized
• IEC (529) IP67 (NEMA 1, 3, 4, 6,
12, 13) Protection
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M30 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
10mm (.39 in.)
Cable
62
66
67
68
Normally Open
9956-1500
9956-1562
9956-1566
9956-1567
9956-1568
Normally Closed
9956-1900
Voltage Range
Operating Frequency
Supply Current
Max. Load Current
Voltage Drop Across Sensor
Max. Leakage Current
Short Term Current (20ms 1Hz)
Switching Frequency
Hysterisis
Temperature Drift
Repeatability
Front Cap Material
9956-1968
90V - 250V
90V - 250V
90V - 250V
90V - 250V
90V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
5 mA
5 mA
5 mA
5 mA
5 mA
180 mA
100 mA
180 mA
180 mA
180 mA
≤8V
≤8V
≤8V
≤8V
≤8V
≤3A/220V
≤3A/220V
≤3A/220V
≤3A/220V
≤3A/220V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
1A
1A
1A
1A
1A
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
1mm (.039 in.)
1mm (.039 in.)
1mm (.039 in.)
1mm (.039 in.)
1mm (.039 in.)
PBTP
PBTP
PBTP
PBTP
PBTB
M
30
x
5
1,
LED
5
60 0
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
M
30
x
1,
5
62 Style Connector
3-pin, Mini style, 25mm (1.0 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
10
25
26
91
56
LED
M
LED (66/68 CN)
30
x
58
1
50
LED (67 CN)
70
66/67/68 Style Connectors
The 66/67 connectors are 4-pin, (68 connector,
3-pin), Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts .
The 67 Connector is clear, offering 360° LED
viewing.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Accessories
Metric/in. Conversion Table
1.0 mm
5.0 mm
6.0 mm
8.0 mm
12.0 mm
23.0 mm
28.0 mm
29.0 mm
34.0 mm
35.0 mm
40.0 mm
43.0 mm
50.0 mm
60.0 mm
= .04 in.
= .20 in.
= .23 in.
= .31 in.
= .47 in.
= .90 in.
=1.10 in.
FIND IT
=
=
=
=
=
=
=
1.14 in.
1.34 in.
1.37 in.
1.57 in.
1.69 in.
1.97 in.
2.36 in.
2 meter (6 ft. 6 in.) AC Cable Assemblies
for Quick Disconnect Sensors
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
62 Connector 8000-5030
66/67 Connector 8000-5060
66/67 Connector 8000-5070
68 Connector 8000-5130
68 Connector 8000-5140
PVC, Straight
PVC, Right Angle
PVC, Straight
PVC Straight
Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M30 Non-Flush Mount
15mm (0.59 in.)
Mounting Brackets – see Pages 114-115
Cable
62
66
67
68
9956-1400
9956-1462
9956-1466
9956-1467
9956-1468
9956-1800
9956-1868
90V - 250V
90V - 250V
90V - 250V
90V - 250
90V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
5 mA
5 mA
5 mA
5 mA
5 mA
180 mA
180 mA
180 mA
180 mA
180 mA
≤8V
≤8V
≤8V
≤8V
≤8V
≤3A/220V
≤3A/220V
≤3A/220V
≤3A/220V
≤3A/220V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
≤1.5mA/110V
1A
1A
1A
1A
1A
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
15Hz/220V
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
1.5mm (.0596in.)
1.5mm (.059 in.)
.4mm (.016in.)
.4mm (.016in.)
.5mm (.02in.)
PBTB
PBTB
PBTB
PBTB
PBTB
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
Note: Sensor dimensions in mm.
Fixed Cable
Fixed Cable
BR
BR
M
30
x
5
1,
BL LOAD
BL LOAD
Yellow/GRN
LED
Yellow/GRN
Normally Open
60
38
12
Normally Closed
62 Connector
1
GRN
WHT
3
M
2
30
BLK LOAD
x
5
1,
Normally Open
12
LED
66/67 Connector
66/67 Connector
56
91
25
26
Yell/GRN 4
Yell/GRN 4
3
3
BL
10
BL
2
1
2
1
LOAD
BLK LOAD
BLK
Normally Open
Normally Closed
68 Connector
68 Connector
M
LED (66/68 CN)
30
x
5
1,
LED (67 CN)
Red/WHT
2 Red
12
3
3
70 8
GRN
LOAD
GRN
1
Normally Open
©Altech
Red/WHT
2 Red
3
LOAD
1
Normally Closed
Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
59
PREVIOUS
HOME
NEXT
• Higher Current Rating
AC - 2 WIRE - EXTENDED
VOLTAGE RANGE – Brass, Nickel
Plated (BN), and TROGAMID T
Cylindrical,Threaded,
20-250V AC, 500 mA,
1 LED for Output Energized
• Wider Voltage Range
• Carries
mark
M12 Flush Mount
Sensing Distance
FIND IT
• IEC (529) IP67 (NEMA 1, 3, 4, 6,
12, 13) Protection
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M12 Non-Flush Mount
2mm (.08 in.)
Cable or Connector Style Cat. No.
4mm (.16 in.)
Cable
Cable
68
Cable
Cable
68
Normally Open
9924-0500
9924-1100
9924-0568
9924-0700
9924-1000
9924-0768
Normally Closed
9924-0400
9924-1300
9924-0468
9924-0900
9924-1200
9924-0968
20V-250V
20V - 250V
20V - 250V
20V - 250V
20V - 250V
20V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
2 mA
2 mA
2 mA
2 mA
2 mA
2 mA
300 mA
300 mA
300 mA
300 mA
300 mA
300 mA
Voltage Range
Operating Frequency
Supply Current
Max. Load Current
Voltage Drop Across Sensor
Max. Leakage Currrent
Short Term Current (20 ms, 1Hz)
≤5V
≤5V
≤5V
≤5V
≤5V
≤5V
≤2mA
≤2mA
≤2mA
≤2mA
≤2mA
≤2mA
2A
2A
2A
2A
2A
2A
Switching Frequency
15Hz
15Hz
15Hz
15Hz
15Hz
15Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.20mm (.008 in.)
.20mm (.008 in.)
.20mm (.008 in.)
.40mm (.016 in.)
.40mm (.016 in.)
.40mm (.016 in.)
PBTP
PBTP
PBTP
PBTB
PBTB
PBTB
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
Repeatability
Front Cap Material
Housing Material
6
LED
70
54
6
70 0
LED
M
M
12
12
x
x
6
1
1
LED
64
70
LED
80
80
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
non-metallic locknuts for Trogamid T
housings and Nickel Plated (BN) locknuts
for Nickel Plated Brass housings.
1
1
x
x
12
12
M
M
Nickel Plated Brass Housings
Trogamid T Housings
M
1
1
x
x
12
12
M
60
54
80
60
6
LED
LED
80
68 Style Connectors
3-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Accessories
Metric/in. Conversion Table
1.0 mm
6.0 mm
8.0 mm
12.0 mm
54.0 mm
= .04 in.
= .23 in.
= .31 in.
= .47 in.
=2.12 in.
FIND IT
60.0 mm
64.0 mm
70.0 mm
80.0 mm
=
=
=
=
2 meter (6 ft. 6 in.) AC Cable Assemblies
for Quick Disconnect Sensors
2.36 in.
2.52 in.
2.75 in.
3.15 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
68 Connector
68 Connector
8000-5130 PVC Straight
8000-5140 Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M18 Flush Mount
M18 Non-Flush Mount
5mm (0.2 in.)
Mounting Brackets – see Pages 114-115
8mm (0.3 in.)
Cable
Cable
68
Cable
Cable
68
9921-1200
9921-2000
9921-1268
9921-1500
9921-2200
9921-1568
9921-1300
9921-2100
9921-1368
9921-1700
9921-2300
9921-1768
20V - 250V
20V - 250V
20V - 250V
20V - 250V
20V - 250V
20V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
2 mA
2 mA
2 mA
2 mA
2 mA
2 mA
500 mA
500 mA
500 mA
500 mA
500 mA
500 mA
≤5V
≤5V
≤5V
≤5V
≤5V
≤5V
≤2mA
≤2mA
≤2mA
≤2mA
≤2mA
≤2mA
8A
8A
8A
8A
8A
8A
15Hz
15Hz
15Hz
15Hz
15Hz
15Hz
≤15%
≤15%
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
.50mm (.02 in.)
.50mm (.02 in.)
.50mm (.02 in.)
.8mm (.039 in.)
.8mm (.039 in.)
.8mm (.039 in.)
PBTB
PBTB
PBTB
PBTB
PBTB
PBTB
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
M
x
18
18
M
1
1
x
Fixed Cable
Fixed Cable
BR
BR
8
LED
LED
BL LOAD
Yellow/GRN
60
42
5
60 0
BL LOAD
Yellow/GRN
Normally Closed
Fixed Cable
Fixed Cable
1
1
x
x
18
18
M
M
Normally Open
BR
8
BR
LED
LOAD
BL LOAD
80
62
7
80 0
LED
BL
Normally Open
M
M
18
18
x
x
1
1
LED
8
LED
68 Connector
68 Connector
Red/WHT
Red/WHT
2 Red
3
5
80 2
60
GRN
80
Normally Closed
2 Red
3
LOAD
1
Normally Open
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
GRN
LOAD
1
Normally Closed
61
PREVIOUS
HOME
NEXT
FIND IT
• Higher Current Rating
AC - 2 WIRE - EXTENDED
VOLTAGE RANGE – Brass, Nickel
Plated (BN), and TROGAMID T
Cylindrical,Threaded,
20-250V AC, 500 mA,
1 LED for Output Energized
• IEC (529) IP67 (NEMA 1, 3, 4, 6,
12, 13) Protection
• Temperature Range:
-25 to 70°C (-13 to 158°F)
• Wider Voltage Range
• Carries
mark
M30 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
10mm (0.39 in.)
Cable
Cable
68
Normally Open
9916-2600
9916-2900
9916-2668
Normally Closed
9916-2100
9916-2400
9916-2168
20V-250V
20V - 250V
20V - 250V
50/60Hz
50/60Hz
50/60Hz
2 mA
2 mA
2 mA
500 mA
500 mA
500 mA
≤5V
≤5V
≤5V
≤2mA
≤2mA
≤2mA
8A
8A
8A
Voltage Range
Operating Frequency
Supply Current
Max. Load Current
Voltage Drop Across Sensor
Max. Leakage Currrent
Short Term Current (20 ms, 1Hz)
Switching Frequency
15Hz
15Hz
15Hz
Hysterisis
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
1mm (.039 in.)
1mm (.039 in.)
1mm (.039 in.)
Temperature Drift
Repeatability
Front Cap Material
Housing Material
PBTP
PBTP
PBTP
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
M
30
x
5
1,
Nickel Plated Brass Housings
5
60 0
M
30
x
5
1,
LED
7
80 0
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
non-metallic locknuts for Trogamid T
housings and Brass, Nickel Plated
(BN) locknuts for Nickel Plated Brass
housings.
Trogamid T Housings
LED
M
30
x
1,
5
80
60
LED
68 Style Connectors
3-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
62
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Accessories
Metric/in. Conversion Table
1.5 mm
12.0 mm
30.0 mm
38.0 mm
48.0 mm
50.0 mm
58.0 mm
60.0 mm
80.0 mm
= .06 in.
= .47 in.
=1.18 in.
=1.50 in.
=1.89 in.
FIND IT
=
=
=
=
1.96 in.
2.28 in.
2.36 in.
3.15 in.
2 meter (6 ft. 6 in.) AC Cable Assemblies
for Quick Disconnect Sensors
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
68 Connector
68 Connector
8000-5130 PVC Straight
8000-5140 Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
M30 Non-Flush Mount
15mm (0.59 in.)
Cable
Cable
68
9916-2700
9916-3000
9916-2768
9916-2300
9916-2500
9916-2368
20V - 250V
20V - 250V
20V - 250V
50/60Hz
50/60Hz
50/60Hz
2 mA
2 mA
2 mA
500 mA
500 mA
500 mA
≤5V
≤5V
≤5V
≤2mA
≤2mA
≤2mA
8A
8A
8A
15Hz
15Hz
15Hz
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
1.5mm (.059 in.)
1.5mm (.059 in.)
1.5mm (.059 in.)
PBTB
PBTB
PBTB
Nickel Plated Brass
Trogamid T
Nickel Plated Brass
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
Note: Sensor dimensions in mm.
Fixed Cable
M
Fixed Cable
30
x
BR
BR
5
1,
BL LOAD
LED
BL LOAD
Yellow/GRN
Yellow/GRN
Normally Closed
Fixed Cable
Fixed Cable
60
38
12
Normally Open
M
30
x
5
1,
BR
BR
LED
LOAD
12
BL LOAD
BL
Normally Closed
80
58
Normally Open
M
30
x
5
1,
68 Connector
68 Connector
Red/WHT
Red/WHT
LED
2 Red
3
4
80 8
12
GRN
2 Red
3
LOAD
1
Normally Open
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
GRN
LOAD
1
Normally Closed
63
PREVIOUS
AC - 2 WIRE – WELD IMMUNE
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
20-250V AC, 300mA/500mA
1 LED for Output Energized
HOME
NEXT
• Circuitry that protects for
electro-magnetic interference
• Flush models have teflon
ceramic coatings to protect
for weld slag
• Carries
mark
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13)
Protection
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M12 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
M12 Non-Flush Mount
2mm (.08 in.)
Cable
4mm (.16 in.)
48
Cable
68
Normally Open
9952-5840
9952-5848
9952-5900
9952-5968
Normally Closed
9952-5640
9952-5648
9952-5700
9952-5768
20V-250V
20V - 250V
20V - 250V
20V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
2 mA
2 mA
2 mA
2 mA
300 mA
300 mA
300 mA
300 mA
≤5V
≤5V
≤5V
≤5V
≤2 mA
≤2 mA
≤2 mA
≤2 mA
2A
2A
2A
2A
Switching Frequency (at Resistance Load of 150 mA)
15 Hz
15 Hz
15Hz
15 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Voltage Range
Operating Frequency
Supply Current
Max. Load Current
Voltage Drop Across Sensor
Max. Leakage Currrent
Short Term Current (20 ms, 1Hz)
Temperature Drift
Repeatability
Front Cap Material
Housing Material
≤10%
.10mm (.004 in.)
≤10%
.10mm (.004 in.)
≤10%
≤10%
.2mm (.008 in.)
.2mm (.008 in.)
Teflon
Teflon
PBTB
Teflon Plated Brass
Teflon Plated Brass
Nickel Plated Brass
PBTB
Nickel Plated Brass
M
12
x
6
1
70
LED
10
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
M
12
x
1
6
LED
10
80
48/68 Style Connector
3-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
64
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.0 mm
6.0 mm
8.0 mm
10.0 mm
12.0 mm
18.0 mm
60.0 mm
70.0 mm
80.0 mm
FIND IT
Accessories
2 meter (6 ft. 6 in.) AC Cable Assemblies
for Quick Disconnect Sensors
= .04 in.
= .23 in.
= .31 in.
= .39 in.
= .47 in.
= .70 in.
=2.36 in.
=2.75 in.
=3.15 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
48/68 Connector 8000-5130 PVC, Straight
48/68 Connector 8000-5140 Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
M18 Flush Mount
M18 Non-Flush Mount
5mm (.20 in.)
8mm (.31 in.)
Mounting Brackets – see Pages 114-115
Cable
48
Cable
68
9954-5840
9954-5848
9954-5900
9954-5968
9954-5640
9954-5648
9954-5700
9954-5768
20V - 250V
20V - 250V
20V - 250V
20V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
2 mA
2 mA
2 mA
2 mA
500 mA
500 mA
500 mA
500 mA
≤5V
≤5V
≤5V
≤5V
≤2 mA
≤2 mA
≤2 mA
≤2 mA
8A
8A
8A
8A
15 Hz
15 Hz
15 Hz
15 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.25mm (.01 in.)
.25mm (.01 in.)
.4mm (.016 in.)
.4mm (.016 in.)
Teflon
Teflon
PBTB
PBTB
Teflon Plated Brass
Teflon Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
M
18
x
1
Fixed Cable
BR
8
LED
BL LOAD
60
Yellow/GRN
10
Normally Open
M
18
x
1
48/68 Connector
Red/WHT
8
LED
2 Red
3
10
80
GRN
LOAD
1
Normally Open
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
65
PREVIOUS
AC - 2 WIRE – WELD IMMUNE
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
20-250V AC, 300/500mA
1 LED for Output Energized
HOME
NEXT
• Circuitry that protects for
electro-magnetic interference
• Flush models have teflon
ceramic coatings to protect
for weld slag
• Carries
mark
M30 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13)
Protection
• Temperature Range:
-25 to 70°C (-13 to 158°F)
M30 Non-Flush Mount
10mm (.39 in.)
Cable
15mm (.59 in.)
48
Cable
68
Normally Open
9956-5840
9956-5848
9956-5900
9956-5968
Normally Closed
9956-5640
9956-5648
9956-5700
9956-5768
20V-250V
20V - 250V
20V - 250V
20V - 250V
50/60Hz
50/60Hz
50/60Hz
50/60Hz
2 mA
2 mA
2 mA
2 mA
500 mA
500 mA
500 mA
500 mA
≤5V
≤5V
≤5V
≤5V
≤2 mA
≤2 mA
≤2 mA
≤2 mA
8A
8A
8A
8A
Switching Frequency (at Resistance Load of 150 mA)
15 Hz
15 Hz
15 Hz
15Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Voltage Range
Operating Frequency
Supply Current
Max. Load Current
Voltage Drop Across Sensor
Max. Leakage Currrent
Short Term Current (20 ms, 1Hz)
Temperature Drift
Repeatability
Front Cap Material
Housing Material
≤10%
≤10%
≤10%
≤10%
.5mm (.02 in.)
.5mm (.02 in.)
.75mm (.03 in.)
.75mm (.03 in.)
Teflon
Teflon Plated Brass
Teflon
Teflon Plated Brass
PBTB
PBTB
Nickel Plated Brass
Nickel Plated Brass
Note: Sensor dimensions in mm.
M
30
x
5
1,
80
12
LED
10
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Supplied with
Brass, Nickel Plated (BN) locknuts.
M
30
x
5
1,
12
LED
10
80
48/68 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
66
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
FIND IT
Metric/in. Conversion Table
1.5 mm
10.0 mm
12.0 mm
30.0 mm
80.0 mm
= .06 in.
= .39 in.
= .47 in.
=1.18 in.
=3.15 in.
This table converts millimeters to inches in reference to the
illustrations included on these pages
Accessories
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
48/68 Connector 8000-5130 PVC, Straight
48/68 Connector 8000-5140 Right Angle
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more
cable information
Mounting Brackets –
see Pages 114-115
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
Fixed Cable
BR
BL LOAD
Yellow/GRN
Normally Open
48/68 Connector
Red/WHT
2 Red
3
GRN
LOAD
1
Normally Open
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
67