PNP NPN - Altech

PREVIOUS
DC - 3WIRE
EXTENDED RANGE PLUS
Brass, Nickel Plated (BN),
Cylindrical,Threaded,
10-30V DC, 200mA
1 LED for Output Energized
PNP
NPN
Normally Open
NEXT
FIND IT
• Up to 3 times the sensing distance • IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Sensing ranges from 3mm (.12 in.) to
• Ideal for applications where large
40mm (1.57 in.)
sensors will not fit
• Short Circuit Protection
• Carries
mark
• Overload Protection
• Reverse Polarity Protection
• Wire Break Resistance
• Temperature Range: -25 to 70°C (-13 to 158°F)
M8 Flush Mount
M8 Non-Flush Mount
3mm (0.1 in.)
6mm (0.2 in.)
Sensing distance
Cable or Connector Style Cat. No.
HOME
Cable
64
65
Cable
64
65
9981-5000
9981-5064
9981-5065
9981-5200
9981-5264
9981-5265
Normally Closed
Normally Open
Normally Closed
Ripple Voltage
≤20%
≤20%
≤20
≤20%
≤20%
≤20%
Voltage Range
10-30V
10-30V
10-30V
10-30V
10-30V
10-30V
Supply Current
≤20mA
≤20mA
≤20mA
≤20mA
≤20mA
≤20mA
Max. Load Current
200mA
200mA
200mA
200mA
200mA
200mA
Voltage Drop Across Sensor
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤2.4V
Max. Leakage Currrent
≤100µA
≤100µA
≤100µA
≤100µA
≤100µA
≤100µA
Switching Frequency
500Hz
1000Hz
1000Hz
1000Hz
500Hz
500Hz
Hysterisis
10%
10%
10%
10%
10%
10%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
≤10%
≤10%
Housing Material
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
.15mm (.005 in.)
.15mm (.005 in.)
.15mm (.005 in.)
.3mm (.01 in.)
.3mm (.01 in.)
.3mm (.01 in.)
Repeatability
M
M
8
8
x
LED
x
45
45
4
1
1
LED
Fixed Cable
PVC 2m (6 ft. 6 in.). Supplied with
Brass, Nickel Plated (BN) locknuts.
8
x
x
1
5
64 8
8
M
M
5
60 4
46
46
4
1
1
x
x
LED
8
8
LED
M
M
64 Connector
3-pin, Pico style, 8mm (.31 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
1
8
x
12
1
1
x
x
44
70 62
M
4
66 58 4
4
1
1
LED
x
12
©Altech
8
LED
M
46
M
M
65 Style Connectors
4-pin, Micro style, 12mm (.47 in.) supplied
with Brass, Nickel Plated (BN) locknuts.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.0 mm
4.0 mm
6.0 mm
8.0 mm
12.0 mm
40.0 mm
44.0 mm
45.0 mm
50.0 mm
M12 Flush Mount
=
=
=
=
=
=
=
=
=
Accessories
52.0 mm
54.0 mm
56.0 mm
58.0 mm
60.0 mm
62.0mm
66.0 mm
70.0 mm
.04 in.
.16 in
.23 in.
.31 in.
.47 in.
1.39 in.
1.73 in.
1.77 in.
1.97 in.
=
=
=
=
=
=
=
=
2.04 in.
2.12 in.
2.20 in.
2.28 in.
2.36 in.
2.44 in.
2.60 in.
2.75 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
M12 Non-Flush Mount
6mm (0.2 in.)
FIND IT
10mm (0.4 in.)
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
64 Connector 8000-5220 PVC, Straight
64 Connector 8000-5230 PVC, Right Angle, 2LED,PNP
64 Connector 8000-5240 PVC, Right Anglr, 2 LED, NPN
65 Connector 8000-5110 PVC, Straight
65 Connector 8000-5120 PVC, Right Angle
65 Connector 8000-5150 PVC, Right Angle, 2LED NPN
65 Connector 8000-5160 PVC, Right Angle, 2LED PNP
Change last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more cable information
Mounting Brackets – see Pages 114-115
Cable
65
Cable
65
9982-5000
9982-5065
9982-5200
9982-5265
Flush Installation
Non-Flush Installation
≤20%
≤20%
≤20%
10-30V
10-30V
10-30V
≤20mA
≤20mA
≤20mA
≤20mA
200mA
200mA
200mA
200mA
≤2.4V
≤2.4V
≤2.4V
≤2.4V
≤100µA
≤100µA
≤100µA
≤100µA
800Hz
800Hz
400Hz
400Hz
10%
10%
10%
10%
≤10%
≤10%
≤10%
≤10%
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
Nickel Plated Brass
.3mm (.01 in.)
.3mm (.01 in.)
.5mm (.02 in.)
.5mm (.02 in.)
Note: Sensor dimensions in mm.
d ≥d d
≥0.2d
≥2d
Metal Material
General Mounting – You must maintain minimum distance
between adjacent and opposite sensors in addition to non-target
metals as specified in the drawings above. Flush mount sensors
must extend at least 0.2 times the sensor diameter above the
adjacent metal housing. Non-flush mount sensors must extend a
distance greater than the sensing distance (Sn). Please contact
Altech for any installation assistance
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
PNP
M
M
12
12
1
1
Fixed Cable
x
LED
x
LED
d
≥Sn
≤20%
10-30V
≥3 x Sn
≥2d
+
6
BR
4
50 0
4
56 0
BK
LOAD
• –
BL
Normally Open
64 Connector
1
+
BR
BK
2/4
LOAD
BL • –
3
Normally Open
M
12
12
M
65 Connector
x
LED
M
1
4 BK
LOAD
2
3
•
BL
–
66
12
1
1
x
x
12
5
60 2
40
4
58 0
6
1
M
©Altech
BR +
1
x
LED
Normally Open
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
47