Feed-Through CTS2.5U-N Altech “U” Series Universal Rail Mounting Standard Screw Clamp Feed through terminals are the most versatile terminals for wire-to-wire connection in control, automation, instrumentation and power distribution applications. A special design fea- Terminal Width ture on the flexible foot enables easy mounting and Height x Length dismounting from the DIN Rail Stripping Length with the help of a screwdriver. Insulation Material The CTC4U Tab Connection terminals offer quick connec- Type of Connection tion possibility. These terminal Approvals blocks are suited for standard Wire Range ‘Fast On’ type lugs. pushing the lug / ferrule onto the tab blade of the terminal Voltage Rating block. Current Rating CTC4U is used primarily in Torque railway systems. CTC4U 5 mm 6 mm 6NEW mm 45 x 43 mm 45 x 43 mm 49.5 x 47 mm 8 mm 8 mm 9 mm Polyamide 6.6 2 screw clamps & 1 tapped hole for cross connect. Polyamide 6.6 2 screw clamps & 1 tapped hole for cross connect. Polyamide 6.6 5 tab connection points and 1 tapped hole for cross connection E220514 60947-7-1 E220514 60947-7-1 Rated Cross Section 1 conductor per clamp The connection is achieved by 2 same size conductors CTS4U-N 22-12 AWG 0.2-2.5 sq.mm 22-12 AWG 22-10 AWG 0.2-4 sq.mm 22-10 AWG 0.25-4.0 sq.mm 0.25-2.5 sq.mm 600 V 1000 V 600 V 600 V 1000 V 600 V 300 V 25 A 24 A 25 A 35/40 A* 32 A 35/40A* 32 A 7 lb-in 0.4 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Tab Blade Size 6.3 x 0.8 See page 91. AEx eII Ex eII U AEx eII Ex eII U A nice alternative to ‘Fast On’ Other Approvals style barrier strips. Terminal Block Mounting Handle 24-12 AWG 24-12 AWG Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. CTS2.5U-N 100 CTS4U-N 100 CTS4U 100 End Plate EP2.5/4UN 50 EP2.5/4UN 50 EPCTC4U 50 Isolation Partition PP2.5/4UN 50 PP2.5/4UN 50 Separator Plate SP2.5/4UN 100 SP2.5/4UN 100 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering info. refer to page 92 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Internal Jumper 2 pole 3 pole 4 pole 10 pole 100 pole CA721/2 CA721/3 CA721/4 CA721/10 CA721/100 100 50 50 10 10 CA722/2 CA722/3 CA722/4 CA722/10 CA722/100 100 50 50 10 10 CA727/2 CA727/3 CA727/4 CA727/10 100 50 50 10 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole 100 pole CA741/2 CA741/3 CA741/4 CA741/10 CA741/100 100 50 50 10 10 CA742/2 CA742/3 CA742/4 CA742/10 CA742/100 100 50 50 10 10 CA747/2 CA747/3 CA747/4 CA747/10 100 50 50 10 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole CA703/01 CA704/01 CA705/01 CA731/10 — CA731/100 100 100 100 100 10 CA703/01 CA704/01 CA705/01 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA 707/S/Q/01 100 CA 707/S/Q/01 100 CA807/S/Q/01 100 CA717/2 CA717/3 CA717/4 CA717/10 100 100 100 25 CA714/2 CA714/3 CA714/4 CA714/10 100 100 100 25 CA707/TS/01 100 CA707/TS/01 100 MT6 100 Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W Current Bars Shorting Sleeve & Screw External Jumper * 35A with one No. 10 AWG and Test Socket 40A with two No. 12 AWG wires. Marking Tags 8 2 pole 3 pole 4 pole 10 pole MT5 100 MT6 100 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Feed-Through CTS6U CTS10U CTS16U CTS25U 8 mm 10 mm 12 mm 12 mm 47 x 43 mm 47 x 43 mm 47 x 43 mm 56 x 49 mm 9 mm 11 mm 12 mm 14 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 2 screw clamps & 1 tapped hole for cross connect. 2 screw clamps & 1 tapped hole for cross connect. 2 screw clamps & 1 tapped hole for cross connect. 2 screw clamps & 1 tapped hole for cross connect. 60947-7-1 E220514 60947-7-1 E220514 60947-7-1 E220514 22-8 AWG 0.5-6 sq.mm 22-8 AWG 22-6 AWG 0.5-10 sq.mm 16-6 AWG 22-6 AWG 0.2-16 sq.mm 20-4 AWG 12-2 AWG 4-25 sq.mm 14-2 AWG 600 V 1000 V 600 V 600 V 1000 V 600 V 600 V 1000 V 600 V 600 V 1000 V 600 V 50 A 41 A 50 A 65 A 57 A 65 A 70 A 76 A 85 A 115 A 101 A 115 A 14 lb-in 0.8 Nm 14 lb-in 1.2 Nm 14 lb-in 14 lb-in 1.2 Nm 14 lb-in 35 lb-in 2.0 Nm 25 lb-in 14 lb-in AEx eII Ex eII U Cat. No. Std. Pk. 60947-7-1 E220514 AEx eII Ex eII U Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. CTS6U 50 EP6/10U 50 EP6/10U 50 EP25U PP6/10U 50 PP6/10U 50 PP25U 50 SP6/10U 100 SP6/10U 100 SP6/10U 100 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CA723/2 CA723/3 CA723/4 CA723/10 100 50 50 10 CA724/2 CA724/3 CA724/4 CA724/10 100 50 50 10 CA751/2 CA751/3 CA751/4 CA751/10 50 50 50 10 CA725/2 CA725/3 CA725/4 CA725/10 50 25 25 10 CA743/2 CA743/3 CA743/4 CA743/10 100 50 50 10 CA744/2 CA744/3 CA744/4 CA744/10 100 50 50 10 CA761/2 CA761/3 CA761/4 CA761/10 50 50 50 10 CA745/2 CA745/3 CA745/4 CA745/10 50 25 25 10 CA703/2 CA704/2 CA705/2 CA733/10 100 100 100 100 CA703/3 CA704/3 CA705/3 CA734/10 100 100 100 100 CA703/8 CA704/8 CA705/8 CA739/10 100 100 100 100 CA703/4 CA704/4 CA705/4 CA735/10 100 100 100 100 CA707/S/Q/1 100 CA707/S/Q/01 100 CA707/S/Q/1 100 CA707/S/Q/2 100 CA710/2 CA710/3 CA710/4 CA710/10 100 100 100 25 CA718/2 CA718/3 CA718/4 CA718/10 100 50 50 25 100 MT10 100 MT12 100 MT12 100 MT8 50 CTS16U 50 CTS25U Std. Pk. CTS10U 50 Altech Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com ® 9 Feed-Through DIN RAIL AND PANEL MOUNTABLE CTS35UN CTS50/70N CTS50/70NA NEW NEW CTS95U/120N NEW with Allen Screw with Allen Screw Terminal Width 16 mm 20.5 mm 20.5 mm Height x Length 58 x 50.5 mm 75.5 x 71 mm 75.5 x 71 mm 90 x 83 mm Stripping Length 15 mm 22 mm 24 mm 24 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw clamps & 1 tapped hole for cross 2 screw clamp connections 2 screw clamp connections 2 screw clamp connections 25 mm Approvals 60947-7-1 Wire Range 60947-7-1 E220514 60947-7-1 E220514 60947-7-1 E220514 E220514 12-2 AWG 4-35 sq.mm 12-2 AWG 8-2/0 AWG 10-70 sq.mm 8-2/0 AWG 8-2/0 AWG 10-70 sq.mm 8-2/0 AWG 2-250 KCMIL 25-120 sq.mm 2-250 KCMIL Voltage Rating 600 V 1000 V 600 V 1000V 1000 V 1000 V 1000V 1000 V 1000 V 1000V 1000 V 1000 V Current Rating 130 A 125 A 130 A 175 A 192 A 175 A 175 A 192 A 175 A 240 A 269 A 240 A 25 lb-in 2.5 Nm 25 lb-in 38 lb-in 3 Nm 38 lb-in 38 lb-in 3 Nm 38 lb-in 90 lb-in 6 Nm 90 lb-in Torque Other Approvals Cat. No. Std. Pk. Terminal Block CTS35UN 50 Isolation Partition PP35UN 50 CA702 CA802 50 50 2 pole 3 pole 4 pole 10 pole 100 pole CA771/2 CA771/3 CA771/4 CA771/10 50 25 25 10 2 pole 3 pole 4 pole 10 pole CA781/2 CA781/3 CA781/4 CA781/10 Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. CTS50/70N 20 CTS50/70NA 20 CTS95U/120N 10 CA202 CA102 50 50 CA202 CA102 50 50 CA202 CA102 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering info. refer to page 92 Internal Jumper Insulated Internal Jumper Current Bars 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole CA703/10 CA704/10 CA705/10 CA770/10 50 25 25 10 100 100 100 100 Shorting Link System 10 Shorting Sleeve & Screw CA707/S/Q/2 100 Marking Tags MT16 100 50 50 Ratings As Per IEC60947-7-1 Voltage/Current: 1000 V / 41 A Torque: 0.8 Nm IEC 60079-7 Voltage/Current: 630 V / 36 A Torque: 0.8 Nm UL-1059 Voltage/Current: 600 V / 50 A Torque: 14 lb-in CSA22.2-158 Voltage/Current: 600 V / 50 A Torque: 14 lb-in AUX6 Auxiliary Terminal Block Used for: CTS50/70N CTS50/70NA CTS95/120N Wire Range 22-8 AWG In certain power circuits, there is a need to take an extra connection for an Auxiliary circuit like an indicating light or contactor. The AUX6 terminal easily plugs into the terminal and provides this extra connection point. Width x Length x Height 8 x 53.6 x 29.4 mm Std. Pk.: 10 Marking Tag: MT8 CA628/2 CA628/3 10 10 CA628/2 CA628/3 10 10 CA629/2 CA629/3 10 10 MT16 100 MT16 100 MT16 100 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com High Voltage Terminal Blocks CHV4U The CHV series Terminal Blocks have been specially designed for high voltage use, such as in solar applications. A specially designed flexible foot enables easy mounting and dismounting from the mounting rail with the help of a screw driver. These Terminal Blocks have marker holding recesses to accept marking tags for circuit identification. Cross connection can be achieved with the aid of shorting links / sleeves & screws. CHV6U NEW CHV10U NEW NEW Terminal Width 6 mm 8 mm 10 mm Height x Length 70.8 x 52 mm 70.8 x 52 mm 70.8 x 52 mm Stripping Length 12 mm 14 mm 14 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Approvals 60947-7-1 60947-7-1 E220514 60947-7-1 E220514 E220514 Wire Range 22-10 AWG 0.2-4 sq.mm 22-10 AWG 22-8 AWG 0.2-6 sq.mm 22-8 AWG 20-6 AWG 0.2-10 sq.mm 22-6 AWG Voltage Rating 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V Current Rating 35 A 32 A 35 A 50 A 41 A 50 A 65 A 57 A 65 A 7 lb-in 0.5 Nm 7 lb-in 14 lb-in 0.8 Nm 14 lb-in 14 lb-in 1.2 Nm 14 lb-in Torque Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CHV4U 100 CHV6U 100 CHV10U 100 End Plate EPUSC 50 EPUSC 50 EPUSC 50 SP2.5/4UN 50 SP2.5/4UN 50 SP2.5/4UN 50 Separator Plate DIN Rail for ordering information refer to pages 90-91 End Stop for ordering info. refer to page 92 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 Internal Jumper 2 pole 3 pole 4 pole 10 pole CA623/2 CA623/3 CA623/4 CA623/10 100 100 100 10 CA624/2 CA624/3 CA624/4 CA624/10 100 100 100 10 CA625/2 CA625/3 CA625/4 CA625/10 100 100 100 10 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole CA643/2 CA643/3 CA643/4 CA643/10 100 100 100 10 CA644/2 CA644/3 CA644/4 CA644/10 100 100 100 10 CA645/2 CA645/3 CA645/4 CA645/10 100 100 100 10 Current Bars 2 pole 3 pole 4 pole 10 pole CA703/1 CA704/1 CA705/1 CA732/10 100 100 100 100 CA703/2 CA704/2 CA705/2 CA733/10 100 100 100 100 CA703/3 CA704/3 CA705/3 CA734/10 100 100 100 100 Short Sleeve & Screw CA608/S/Q 100 CA609/S/Q 100 CA610/S/Q 100 Marking Tags MT6 100 MT8 100 MT10 100 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 11 Feed-Through Multi-Connection CMC2-2 CMC1-2 Connect multiple wires to a single terminal block and eliminate reliability problems encountered when connecting two wires into a single clamp. Two versions are available. Type CMC1-2 features a single screw-cage clamp for 22-10 AWG wires on one side and two clamps on the other side for 22-10 AWG wires. Type CMC2-2 has two identical clamps for 22-10 AWG wires on both sides. Having 2 internal jumper ports makes jumping every other pole convenient. Terminal Width 6 mm 6 mm Height x Length 47 x 46.5 mm 51.5 x 65 mm Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 3 screw clamps & 1 tapped hole for cross connection 4 screw clamps & 2 tapped holes for cross connection Approvals 60947-7-1 E220514 60947-7-1 E220514 22-10AWG 0.2-4 sq.mm 22-10 AWG 22-10 AWG 0.2-4 sq.mm 22-10 AWG Voltage Rating 600 V 630 V 600 V 600 V 630 V 600 V Current Rating 35 A 32 A 35 A 35 A 32 A 35 A 7 lb-in. 0.5 Nm 7 lb-in. 7 lb-in. 0.5 Nm 7 lb-in. Wire Range Torque Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CMC1-2 100 CMC2-2 50 End Plate EPCMC1-2 50 EPCMC2-2 50 CA702 CA802 50 50 CA702 CA802 50 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 COLOR BLOCKS Internal Jumper 2 pole 3 pole 4 pole 10 pole 100 pole CA722/2 CA722/3 CA722/4 CA722/10 CA722/100 100 50 50 10 5 CA722/2 CA722/3 CA722/4 CA722/10 CA722/100 100 50 50 10 5 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole 100 pole CA742/2 CA742/3 CA742/4 CA742/10 CA742/100 100 50 50 10 5 CA742/2 CA742/3 CA742/4 CA742/10 CA742/100 100 50 50 10 5 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA707/S/Q/01 100 CA707/S/Q/01 100 CA714/2 CA714/3 CA714/4 CA714/10 100 100 50 25 CA714/2 CA714/3 CA714/4 CA714/10 100 100 50 25 MT6 100 MT6 100 (other than standard grey) When ordering please add color suffix to Cat. No. Current Bars Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 12 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole Shorting Sleeve & Screw External Jumper Marking Tags 2 pole 3 pole 4 pole 10 pole Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Feed-Through Double Level Altech double level terminals are the answer to high wiring density problems posed by certain unavoidable wiring arrangements. Double level terminals have the following advantages: • Double wiring density available without extension of mounting rails. • Interconnection/shorting can be done at both levels. • Marking/identification by marking tags possible at both levels. CDL4UN(I.S) internally shorted double level terminals are useful for distribution applications by using shorting links at lower levels. NEW NEW Terminal Width 6 mm 6 mm Height x Length 54 x 55.5 mm 54 x 55.5 mm Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 4 screw clamps & 2 tapped holes for cross connection 4 screw clamps & 1 tapped hole for cross connection Approvals 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 22-10 AWG 0.2-4 sq.mm 22-10 AWG Voltage Rating 600V 800 V 600 V 600 V 800 V 600 V Current Rating 35 A 32 A 35 A 35 A 32 A 35 A 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Wire Range Now uses larger MT6 tag for easier visibility. CDL4UN(I.S) CDL4UN Torque 60947-7-1 E220514 Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CDL4UN 100 CDL4UN(I.S) 100 End Plate EPCDL4UN 50 EPCDL4UN 50 Separator Plate SPCDL4U 100 SPCDL4U 100 CA702 CA802 50 50 CA702 CA802 50 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W Internal Jumper 2 pole 3 pole 4 pole 10 pole CA722/2 CA722/3 CA722/4 CA722/10 100 50 50 10 CA722/2 CA722/3 CA722/4 CA722/10 100 50 50 10 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole CA742/2 CA742/3 CA742/4 CA742/10 100 50 50 10 CA742/2 CA742/3 CA742/4 CA742/10 100 50 50 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA707/S/Q/01 100 CA607/S/Q 100 CA714/2 CA714/3 CA714/4 CA714/10 100 100 50 25 CA714/2 CA714/3 CA714/4 CA714/10 100 100 50 25 MT6 100 MT6 100 Current Bars 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole Shorting Sleeve & Screw External Jumper Marking Tags 2 pole 3 pole 4 pole 10 pole Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 13 Feed-Through Offset Double Level ODL4U Altech Offset Double Level Terminals provide a separate connection at two levels. In ODL, the top level is offset from the bottom level by half the thickness of the terminal. This offset provides better accessibility to the screws on the lower level. It is recommended to use end plates at both ends of assembled ODL terminal sets for flat alignment to enable effective use of end stops. Terminal Width 6 mm Height x Length 63 x 68 mm Stripping Length 9 mm Insulation Material Polyamide 6.6 Type of Connection 4 screw clamps & 2 tapped holes for cross connection Approvals 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG Voltage Rating 600 V 800 V 600 V Current Rating 35 A 32 A 35 A 7 lb-in 0.5 Nm 7 lb-in Wire Range Torque Other Approvals Cat. No. Terminal Block End Plate Front Back Std. Pk. ODL4U 50 EPODL4U EP1ODL4U 50 50 CA702 CA802 50 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper 2 pole 3 pole 4 pole 10 pole CA727/2 CA727/3 CA727/4 CA727/10 10 10 10 10 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole CA747/2 CA747/3 CA747/4 CA747/10 100 50 50 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA607/S/Q 100 CA714/2 CA714/3 CA714/4 CA714/10 100 100 50 25 MT6 100 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Current Bars Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 14 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole Shorting Sleeve & Screw External Jumper Marking Tags 2 pole 3 pole 4 pole 10 pole Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Feed-Through Triple Level CTL2.5U CTL2.5U-H For applications with extreme space constraints. Only 6mm (.236”) wide, with three separate feed-through levels. Jumpers can be used to reduce field wiring. They can also be used in control systems where sensors and actuator applications are involved. The top level of CTL2.5U-H terminal block provide connecting points for signal while middle and bottom level provide connecting points are used for positive and negative potential. Terminal Width 6 mm 6 mm Height x Length 67 x 61 mm 67 x 84 mm Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 4 Screw clamps & 3 tapped holes for cross connect. 6 Screw clamps & 3 tapped holes for cross connect. LED Voltage Approvals 60947-7-1 60947-7-1 E220514 22-12 AWG 0.2-2.5 sq.mm 22-12 AWG Wire Range E220514 22-12 AWG 0.2-2.5 sq.mm 22-12 AWG Voltage Rating 300 V 500 V 300 V 300 V 500 V 300 V Current Rating 25 A 24 A 25 A 25 A 24 A 25 A 4.5 lb-in 0.4 Nm 4.5 lb-in 4.5 lb-in 0.4 Nm 4.5 lb-in Torque Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CTL2.5U-H 50 CTL2.5U 50 End Plate EPCTL2.5U-H 50 EPCTL2.5U 50 CA202 CA702 CA802 50 50 50 CA202 CA702 CA802 50 50 50 CA722/2 CA722/3 CA722/4 CA722/10 CA722/100 100 50 50 10 5 CA722/2 CA722/3 CA722/4 CA722/10 CA722/100 100 50 50 10 5 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA707/S/Q/01 100 CA707/S/Q/01 100 CA715/2 CA715/3 CA715/4 CA715/10 100 100 100 50 CA715/2 CA715/3 CA715/4 CA715/10 100 100 100 50 MT2 100 MT2 100 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 COLOR BLOCKS Internal Jumper 2 pole 3 pole 4 pole 10 pole 100 pole Current Bars 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole (other than standard grey) When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W Shorting Sleeve & Screw External Jumper Marking Tags 2 pole 3 pole 4 pole 10 pole Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 15 Feed-Through Triple Level CTL2.5U-H(L)* CTL2.5U(L)* Terminal Width 6 mm 6 mm Height x Length 67 x 61 mm 67 x 84 mm Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 4 Screw clamps & 2 tapped holes for cross connect. 6 Screw clamps & 2 tapped holes for cross connect. LED Voltage 12V, 24V, 110V DC 12V, 24V, 110V DC Ideal for sensor applications. See Altech’s Inductive Proximity Sensor catalog for ordering information. Approvals 60947-7-1 E220514 0.2-2.5 sq.mm 22-12 AWG 300 V 500 V 300 V 25 A 25 A 24 A 25 A 4.5 lb-in 4.5 lb-in 0.4 Nm 4.5 lb-in 60947-7-1 E220514 22-12 AWG 0.2-2.5 sq.mm 22-12 AWG Voltage Rating 300 V 500 V 300 V Current Rating 25 A 24 A 4.5 lb-in 0.4 Nm Wire Range Torque 22-12 AWG In applications where switching indication is required, choice of CTL2.5UH(L) and CTL2.5U(L) terminal blocks with built-in electronic components are available. Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CTL2.5U-H(L)* 50 CTL2.5U(L)* 50 End Plate EPCTL2.5U-H 50 EPCTL2.5U 50 CA202 CA702 CA802 50 50 50 CA202 CA702 CA802 50 50 50 CA722/2 CA722/3 CA722/4 CA722/10 CA722/100 100 50 50 10 5 CA722/2 CA722/3 CA722/4 CA722/10 CA722/100 100 50 50 10 5 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA707/S/Q/01 100 CA707/S/Q/01 100 CA715/2 CA715/3 CA715/4 CA715/10 100 100 100 50 CA715/2 CA715/3 CA715/4 CA715/10 100 100 100 50 MT2 100 MT2 100 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper 2 pole 3 pole 4 pole 10 pole 100 pole Current Bars 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole Shorting Sleeve & Screw External Jumper Marking Tags 2 pole 3 pole 4 pole 10 pole +ve -ve Circuit Diagrams +ve -ve * Add required voltage to part number as suffix; i.e. CTL2.5U(L)/24 for 24V DC 16 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Double & Triple Level Blocks with Ground The CDLG2.5 is a double level and the CTLG2.5 is a triple level terminal block with an additional connection point for earthing (Grounding) cables. This separate connection point is appropriately identified by the green-yellow imprint on its top. The triple level terminal block is an ideal choice for motor, sensor, actuator and initiator connections. CTLG2.5 CDLG2.5 NEW NEW Terminal Width 6 mm 6 mm Height x Length 50 x 71 mm 62 x 87.5 mm Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 5 Screw clamps & 2 tapped holes for cross connect. 7 Screw clamps & 1 tapped hole for cross connect. Approvals 60947-7-1 E220514 24-12 AWG 0.25-4 mm 24-12 AWG Voltage Rating 300 V 500 V Current Rating 24 A 4.5 lb-in Wire Range Torque 60947-7-1 E220514 24-12 AWG 0.25-4 mm 24-12 AWG 300 V 300 V 440 V 600 V 24 A 24 A 25 A 24 A 24 A 0.4 Nm 4.5 lb-in 4.5 lb-in 0.4 Nm 4.5 lb-in Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CDLG2.5 50 CTLG2.5 50 End Plate EPCDLG2.5 50 EPCTLG2.5 50 CA202 CA702 CA802 50 50 50 CA202 CA702 CA802 50 50 50 CA627/2 CA627/3 CA627/4 CA627/10 100 50 50 10 CA627/2 CA627/3 CA627/4 CA627/10 100 50 50 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA611/S/Q 100 CA611/S/Q 100 CA715/2 CA715/3 CA715/4 CA715/10 100 100 100 50 CA715/2 CA715/3 CA715/4 CA715/10 100 100 100 50 MT2G 100 MT2G 100 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper 2 pole 3 pole 4 pole 10 pole Current Bars 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole Shorting Sleeve & Screw External Jumper Marking Tags 2 pole 3 pole 4 pole 10 pole Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 17 Ground Blocks Use ground blocks instead of grounding studs and wire lugs to terminate ground wires, saving installation and wiring time. CGT4U CGT4N They offer: • High density • Screw-cage clamp • Special clamping foot • Polyamide 6.6 • Color: green/yellow Ground blocks clamp mechanically onto the DIN Rail by tightening the center mounting screw, making a reliable electrical connection between the cage clamp terminals and the DIN Rail. The rail serves as a busbar and automatically distributes ground potential to all other ground terminals on the same rail. Ground blocks can also be used as end stops, preventing other terminal blocks and components from moving laterally on the DIN Rail. They are supplied with a standard green/yellow housing for easy identification and accept standard marking tags. CGT4U and CGT35U can be mounted on both DIN 32mm and DIN 35mm rails. Terminal Width 6 mm 6 mm Height x Length 48 x 43 mm 45.4 x 54.2 mm Stripping Length 8 mm 8 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw clamps 2 screw clamps Approvals 60947-7-2 Wire Range Torque E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 7 lb-in 0.5 Nm 7 lb-in Other Approvals Terminal Block 60947-7-2 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 7 lb-in 0.5 Nm 7 lb-in AEx eII Ex eII U Cat. No. Std. Pk. Cat. No. Std. Pk. CGT4U 50 CGT4N 50 EPCGT4U 50 MT6 100 MT6 100 DIN Rail for ordering information refer to pages 90-91 End Plate Marking Tags (MT Type) CGT4N, CGT6N, CGT10N and CGT16N can be mounted on 35mm DIN rail and have the same top outer profile as the feed through blocks (CTS4UN, CTS2.5U-N, CTS6U, CTS10U and CTS16U). 18 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Ground Blocks CGT6N CGT10N CGT16N CGT35U 8 mm 10 mm 12 mm 16 mm 47 x 54.5 mm 50 x 45 mm 47 x 43 mm 61.5 x 58 mm 9 mm 11 mm 12 mm 15 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 2 screw clamps 2 screw clamps 2 screw clamps 2 screw clamps 60947-7-2 E220514 22-8 AWG 0.2-6 sq.mm 22-8 AWG 14 lb-in 0.8 Nm 14 lb-in 60947-7-2 E220514 60947-7-2 E220514 60947-7-2 0.2-10 sq.mm 16-6 AWG 0.2-16 sq.mm 20-4 AWG 8-2 AWG 2.5-35 sq.mm 8-2 AWG 1.2 Nm 14 lb-in 1.2 Nm 14 lb-in 25 lb-in 2.5 Nm E220514 25 lb-in AEx eII Ex eII U AEx eII Ex eII U Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. CGT6N 50 CGT10N 50 CGT16N 50 CGT35U 20 MT8 100 MT10 100 MT12 100 MT15 100 Assembly for single phase 3 wire circuits. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 19 Fuse Blocks, 5 x 20 and 5 x 25 mm CF4U† Altech fuse terminals are also available with light indication CF4U(L). A specially designed built-in circuit gives light indication in the event of fuse blow out. Thus, fault in a circuit can be easily located. No polarity is required. CF4U(L)†* NEW NEW No End Plate Required. Important: Terminal Width The disconnecting device is not suitable for interrupting load. The Height x Length supply must be switched off before Stripping Length operating the slide link/lever. † Fuses are sold separately see pages 100-101. *Add required voltage to part number as a suffix. i.e. CF4U(L)/6-60 for 6-60 V AC/DC. No Polarity Required. 8 mm 8 mm 57.6 x 57 mm 57.6 x 57 mm 9.5 mm 9.5 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw clamps 2 screw clamps CF4U(L)/6-60V CF4U(L)/90-240V 6-60 V AC/DC 90-240 V AC/DC LED Voltage Size of Fuse Used Type of Fuse Used Ø5x20, Ø5x25 mm Glass Ø5x20, Ø5x25 mm Glass Approvals 60947-7-3 22-10 AWG 0.2-4 mm2 Wire Range E220514 E220514 60947-7-3 22-10 AWG 22-10 AWG 0.2-4 mm2 22-10 AWG Voltage Rating 600 V 1000 V 600 V 600 V 600 V 600 V Current Rating 10 A 6.3 A 10 A 10 A 6.3 A 10 A 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. Torque 7 lb-in 0.5 Nm Cat. No. Std. Pk. Other Approvals Terminal Block CF4U 100 CF4U(L)* CA702 CA802 50 50 CA702 CA802 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper COLOR BLOCKS (other than standard grey) Insulated Internal Jumper When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 20 Current Bar CF4U(L) Only 2 pole 3 pole 4 pole 10 pole 27KΩ 27KΩ 2 pole 3 pole 4 pole 10 pole LED Circuit for offline indication in CF4U(L)/6-60V 200KΩ 2 pole 3 pole 4 pole 10 pole 200KΩ LED Circuit for offline indication in CF4U(L)/90-240V Shorting Sleeve & Screw External Jumper 50 50 2 pole 3 pole 4 pole 10 pole Marking Tags (on terminal) (on Lever) CA711/2 CA711/3 CA711/4 CA711/10 100 50 50 20 CA711/2 CA711/3 CA711/4 CA711/10 100 50 50 25 MT8 MT8 100 100 MT8 MT8 100 100 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Fuse Blocks, 5 x 20 and 5 x 25 mm DDFL4U DDFL4U(E)* † Fuse not included. DDFL4U - Double Level Fuse Terminal with fuse link on the top level has a separate feed through terminal at the lower level. This eliminates use of an additional feed through terminal. In DDFL4U(E), specially designed built in circuit gives light indication in the event of a fuse blow out at the top level. The terminal provides separate feed through connection possibility at the lower level. Important: The disconnecting device is not suitable for interrupting load. The supply must be switched off before operating the slide link/lever. † Fuses are sold separately Altech, see pages 100-101. 8 mm 8 mm Height x Length 66 x 88 mm 66 x 88 mm Stripping Length 9.5 mm 9.5 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 4 screw clamps & 1 tapped hole for cross connection 4 screw clamps & 1 tapped hole for cross connection 24V AC/DC, 48V AC/DC, 110V AC/DC, 220V AC/DC, 440V AC LED Voltage Ø5x20, Ø5x25 mm Type of Fuse Used Ø5x20, Ø5x25 mm Approvals 60947-7-3 E220514 Voltage Rating 600 V 800 V 600 V 600 V 800 V 600 V 6.3 A 35 A 6.3 A 32 A 6.3 A 35 A 6.3 A 35 A 6.3 A 32 A 6.3 A 35 A 7 lb-in 0.5 N 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Std. Pk. Cat. No. Top Level Torque 22-10 AWG 0.2-4 mm E220514 22-10 AWG 0.2-4 mm Current Rating 22-10 AWG 60947-7-3 Wire Range 2 2 22-10 AWG Other Approvals Cat. No. * Add required voltage to part number as suffix, i.e. DDFL4U(E)/24 for 24V AC/DC † Fuse not included. Terminal Width Std. Pk. Terminal Block DDFL4U 20 DDFL4U(E)* 20 End Plate EPDDFL4U 20 EPDDFL4U 20 CA702 CA802 CA202 50 50 50 CA702 CA802 CA202 50 50 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W Internal Jumper 2 pole 3 pole 4 pole 10 pole CA729/2 CA729/3 CA729/4 CA729/10 100 50 50 10 CA729/2 CA729/3 CA729/4 CA729/10 100 50 50 10 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole CA749/2 CA749/3 CA749/4 CA749/10 100 50 50 10 CA749/2 CA749/3 CA749/4 CA749/10 100 50 50 10 Current Bar 2 pole 3 pole 4 pole 10 pole CA703/6 CA704/6 CA705/6 CA737/10 100 100 100 100 CA703/6 CA704/6 CA705/6 CA737/10 100 100 100 100 Shorting Sleeve & Screw CA707/S/Q/3 100 CA707/S/Q/3 100 External Jumper CA711/2 CA711/3 CA711/4 CA711/10 100 100 50 25 CA711/2 CA711/3 CA711/4 CA711/10 100 100 50 25 MT8 MT2 100 100 MT8 MT2 100 100 2 pole 3 pole 4 pole 10 pole Marking Tags (on terminal) (on lever) Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 21 Fuse Blocks, 5 x 20 and 5 x 25 mm DDFL4ULR DDFL4U(E)LR* † Fuse not included. DDFL4ULR is a modified version of the DDFL4U terminal where two equipotential connection points are available on both ends of the terminal. 8 mm 8 mm Height x Length 66 x 88 mm 66 x 88 mm Stripping Length 9.5 mm 9.5 mm Insulation Material Polyamide 6.6 4 screw clamps & 1 tapped hole for cross connection Polyamide 6.6 4 screw clamps & 1 tapped hole for cross connection Type of Connection DDFL4U(E)LR* is similar to the DDFL4ULR, but has a built in circuit that gives light indication in the event of a blown fuse. Important: The disconnecting device is not suitable for interrupting load. The supply must be switched off before operating the slide link/lever. 24V AC/DC, 48V AC/DC, 110V AC/DC, 220V AC LED Voltage * Add required voltage to part number as suffix, i.e. DDFL4U(E)LR/24 for 24V AC/DC Ø5x20, Ø5x25 mm Ø5x20, Ø5x25 mm Type of Fuse Used Approvals E220514 60947-7-3 60947-7-3 E220514 Wire Range 22-10 AWG 0.2-4 mm 22-10 AWG Voltage Rating 600 V 800 V 600 V 600 V 800 V 600 V 6.3 A 6.3 A 6.3 A 6.3 A 6.3 A 6.3 A 7 lb-in 0.5 N 7 lb-in 7 lb-in 0.5 Nm 7 lb-in 2 Current Rating † Fuses are sold separately Altech, see pages 100-101. † Fuse not included. Terminal Width Top Level Torque 22-10 AWG 0.2-4 sq.mm 22-10 AWG Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block DDFL4ULR 20 DDFL4U(E)LR* 20 End Plate EPDDFL4U 20 EPDDFL4U 20 CA702 CA802 CA202 50 50 50 CA702 CA802 CA202 50 50 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 22 Internal Jumper 2 pole 3 pole 4 pole 10 pole CA730/2 CA730/3 CA730/4 CA730/10 100 50 50 10 CA730/2 CA730/3 CA730/4 CA730/10 100 50 50 10 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole CA740/2 CA740/3 CA740/4 CA740/10 100 50 50 10 CA740/2 CA740/3 CA740/4 CA740/10 100 50 50 10 Current Bar 2 pole 3 pole 4 pole 10 pole CA703/7 CA704/7 CA705/7 CA738/10 100 100 100 100 CA703/7 CA704/7 CA705/7 CA738/10 100 100 100 100 Shorting Sleeve & Screw CA707/S/Q/8 100 CA707/S/Q/8 100 External Jumper CA711/2 CA711/3 CA711/4 CA711/10 100 100 50 25 CA711/2 CA711/3 CA711/4 CA711/10 100 100 50 25 MT8 MT2 100 100 MT8 MT2 100 100 2 pole 3 pole 4 pole 10 pole Marking Tags (on terminal) (on lever) Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Fuse Blocks, 1/4 x 1 and 1/4 x 11/4 in. CAFL4U(L)* CAFL4U CAFL4U(N) CAFL4U(L) is equipped with a LED for blown fuse indication. CAFL4U(N) is equipped with a neon bulb for same application. † Fuse not included. † Fuse not included. † Fuse not included. Terminal Width 9 mm 9 mm 9 mm Height x Length 50 x 72 mm 50 x 72 mm 50 x 72 mm Stripping Length 9.5 mm 9.5 mm 9.5 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw clamps 2 screw clamps 2 screw clamps 24V AC/DC, 48V AC/DC, 110V AC/DC, 220V AC, 300V AC 110-220V AC/DC, 300V AC Ø1/4x1 in., Ø1/4x11/4 in. Ø1/4x1 in., Ø1/4x11/4 in. LED/Neon Voltage Type of Fuse Used Ø1/4x1 in., Ø1/4x11/4 in. Approvals 60947-7-3 Wire Range E220514 60947-7-3 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 22-10 AWG 0.2-4 sq.mm 22-10 AWG 60947-7-3 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG Voltage Rating 600 V 1000 V 600 V 600 V 1000 V 600 V 600 V 1000 V 600 V Current Rating 16 A 6.3 A 16 A 16 A 6.3 A 16 A 16 A 6.3 A 16 A 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Torque Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CAFL4U 25 CAFL4U(L)* 25 CAFL4U(N) 25 End Plate EPCAFL4U 50 EPCAFL4U 50 EPCAFL4U 50 End Stop for ordering information refer to page 92 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 External Jumper CA716/2 CA716/3 CA716/4 CA716/10 50 50 50 25 CA716/2 CA716/3 CA716/4 CA716/10 100 50 50 20 CA716/2 CA716/3 CA716/4 CA716/10 100 50 50 20 MT9 100 MT9 100 MT9 100 DIN Rail for ordering information refer to pages 90-91 Marking Tags 2 pole 3 pole 4 pole 10 pole 27KΩ 1N4007 LED Circuit for offline indication in CAFL4UL24V Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 23 Fuse Holders, 10 x 38 mm and CC Type 1 POLE 2 POLE 3 POLE 17.5 mm 35 mm 52.5 mm Height x Length 81 x 64.5 mm 81 x 64.5 mm 81 x 64.5 mm Stripping Length 11 mm 11 mm 11 mm Insulation Material Aculon ® Aculon ® Aculon ® Type of Connection 2 screw clamps 2 screw clamps 2 screw clamps 1.5-25sq.mm / 24-4 AWG 1.5-25sq.mm / 24-4 AWG 1.5-25sq.mm / 24-4 AWG 690 V / 32A 690 V / 32A 690 V / 32A The main characteristics of fuse disconnectors are: • UL recognized (10x38mm) • UL listed (CC Type) • Compliance with IEC 60947-1, IEC 60947-3 • Plastic parts are made of material resistant to high temperatures • All contact surfaces are silver plated • Mounting on standard DIN 35 mm rail (DIN EN60715). • Available up to 4 pole • For all sizes a version with electronic indicator is available. There are two technical types of indicator: L (LED) (10x38mm only) with built in LED diode which blinks after the fuse-link operates. The internal circuit resistance is 2M, thus the total dissipation is minimal. The indicator is capable of operating in conditions of open circuit with minimum capacitance be-tween connection cables. Operating voltage range spans from 50V to 690V AC and DC. Terminal Width (B) Wire Range Rating Rating Torque Cylindrical 10x38 Indicator: None LED Neon 600 V AC/DC / 30A 600 V AC/DC / 30A 2-2.5 Nm / 31 lb-in Cat. No. 2-2.5 Nm / 31 lb-in Std. Pk. CB1038-1 CB1038-1/L CB1038-1/I Cat. No. CB1038-2 CB1038-2/L CB1038-2/I 1 1 1 Ø10 x 38 mm Type of Fuse Used Std. Pk. 1 1 1 600 V AC/DC / 30A 2-2.5 Nm / 31 lb-in Cat. No. Std. Pk. CB1038-3 CB1038-3/L CB1038-3/I Ø10 x 38 mm 1 1 1 Ø10 x 38 mm Approvals** E212627 CC Type Holder I (NEON) (10x38mm only) with neon lamp, which is constantly lit after the fuselink operates. The internal Type of Fuse Used circuit resistance is 570k, thus it is necessary that the Approvals circuit be closed in order for the indicator to function. The operational voltage range is DIN Rail for ordering information 100 V to 750 V AC. Cat. No. E212627 Std. Pk. CB10CC-1 1 Cat. No. Std. Pk. CB10CC-2 CC Type 1 E212627 Cat. No. CB10CC-3 CC Type E212627 Std. Pk. 1 CC Type E212627 E212627 refer to pages 90-91 * Fuses are sold separately Altech, see pages 100-101. **1000V UL PV rating pending. End Stop for ordering information refer to page 92 CA702 CA802 50 50 CA702 CA802 50 50 50 50 79 mm (3.11 in.) 64.5 mm (2.54 in.) Cylindrical 10 x 38 47.5 mm (1.87 in.) 37 mm (1.46 in.) 4 mm (0.16 in.) B 81 mm (3.19 in.) CC Type 24 CA702 CA802 Dimension for B: 1 Pole 1 Pole + Neutral 2 Pole 3 Pole 3 Pole + Neutral 17.5mm 35mm 35mm 52.5mm 70mm Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com With Altech’s large line of UL Circuit Protection Devices you get the right product for your application. • V-EA Series - UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” • UL(AC), DL(DC) Series - UL489 Miniature Molded Case Circuit Breakers • L Series - AC or DC Miniature Molded Case Circuit Breakers • UR Series - UL1077 Recognized Supplementary Protector • R Series - UL1077 Recognized Supplementary Protector • UL489 Busbar Systems • UL508 and UL1077 Busbar Systems • MA Series - Three Phase Adjustable Trip Miniature Circuit Breakers/ Manual Motor Controllers • MS Series - Three Phase Adjustable Trip Economy • Manual Motor Controllers • RP Series - RCCB Earth Leakage Circuit Breakers • TR11, TR20 and TR30 Series - UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment • TD / TS Series - UL489 Listed Molded Case Circuit Breakers Visit altechcorp.com/breakers Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 25 Disconnect Disconnect and test terminals are an ideal choice for measuring control and regulatory circuits. The terminals provide a clear functional advantage for devices having utility instruments and associated transformers. • CSDL4U - hinged disconnection and testing terminal, incorporates a connecting link in place of the fuse link. • DDDL4U - double level disconnect terminal with hinged disconnect in upper level. DDDL4U CSDL4U Terminal Width 8 mm 8 mm Height x Length 43 x 58 mm 66 x 88 mm Stripping Length 9.5 mm 9.5 mm Insulation Material Polyamide 6.6 Polyamide 6.6 2 screw clamps 4 screw clamps & 1 tapped hole for cross connection Important: The disconnecting Type of Connection device is not suitable for interrupting load. The supply must be Approvals switched off before operating the slide link/lever. 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 22-10 AWG 0.2-4 sq.mm 22-10 AWG Voltage Rating 600 V 1000 V 600 V 600 V 800 V 600 V Current Rating 14 A 10 A 14 A 14 / 35 A 10 A 6.3 / 35 A 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Wire Range Torque 60947-7-1 E220514 Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CSDL4U 100 DDDL4U End Plate EPCSFL4U 50 EPDDFL4U 20 Isolation Partition PPCSFL4U 50 CA702 CA802 50 50 CA702 CA802 50 50 20 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper 2 pole 3 pole 4 pole 10 pole CA729/2 CA729/3 CA729/4 CA729/10 100 50 50 10 Insulated Internal Jumper 2 pole 3 pole 4 pole 10 pole CA749/2 CA749/3 CA749/4 CA749/10 100 50 50 10 Current Bar 2 pole 3 pole 4 pole 10 pole CA703/6 CA704/6 CA705/6 CA737/10 100 100 100 100 CA707/S/Q/3 100 Shorting Sleeve & Screw External Jumper 2 pole 3 pole 4 pole 10 pole Marking Tags (on terminal) (on lever) 26 CA711/2 CA711/3 CA711/4 CA711/10 100 100 50 25 CA711/2 CA711/3 CA711/4 CA711/10 100 100 50 25 MT8 MT2 100 100 MT8 MT2 100 100 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Disconnect and Test Terminal Blocks CKT4U Disconnect and test terminals are an ideal choice for measuring control and regulatory circuits. The terminals provide a clear functional advantage for devices having utility instruments and associated transformers. CKT4U/4 NEW CKT4U and CKT4U/4 - disconnection is achieved by lifting the knife contact lever. CKT4U/4 Terminal has standard screws on the upper level clamps and socket screws on the lower level clamps. Specially designed socket head screws act as test/monitoring points in the CKT4U. Important: The disconnecting device is not suitable for interrupting load. The supply must be switched off before operating the slide link/lever. Terminal Width 6 mm 6 mm Height x Length 46 x 46.3 mm 46 x 46.3 mm Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw clamps 2 screw clamps Approvals 60947-7-1 22-10 AWG 0.2-4 sq.mm Wire Range E220514 60947-7-1 22-10 AWG 22-10 AWG 0.2-4 sq.mm 22-10 AWG E220514 Voltage Rating 600 V 800 V 600 V 600 V 800 V 600 V Current Rating 16 A 28 A 30 A 20 A 20 A 20 A 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Torque Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CKT4U 50 CKT4U/4 50 End Plate EPCKT4U 50 EPCKT4U/4 50 CA702 CA802 50 50 CA702 CA802 50 50 CA714/2 CA714/3 CA714/4 CA714/10 100 100 50 25 CA714/2* CA714/3* CA714/4* CA714/10* 100 100 50 25 MT6 100 MT6 100 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 External Jumper Marking Tags 2 pole 3 pole 4 pole 10 pole * Insulated External shorting links can be used only in the upper level clamping unit of the Terminal Block. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 27 Disconnect and Test Terminal Blocks Disconnect and test terminals are an ideal choice for measuring control and regulatory circuits. The terminals provide a clear functional advantage for devices having utility instruments and associated transformers when it is mandatory to keep the secondary side shorted at any point while taking current measurements. Specially designed socket head screws act as test/monitoring points. CDTTU + CDTTU-SH - disconnection is achieved by means of a slide link operated with a screw driver. In the CDS6U separate testing points facilitate insertion of test probes. Disconnection is achieved by means of a slide link operated with a Screw Driver. CDTTU Terminal Width 8 mm 16 mm Height x Length 57 x 63 mm 57 x 63 mm Stripping Length 12 mm 12 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw clamps 4 screw clamps Approvals 60947-7-1 Wire Range E220514 60947-7-1 E220514 16-8 AWG 1.5-6 sq.mm 16-8 AWG 16-8 AWG 1.5-6 sq.mm 16-8 AWG Voltage Rating 600 V 800 V 600 V 300 V 160 V 300 V In the CDS6U/TS, the insulated test point screw system (TPSLS) is integrated. Current Rating 41 A 41 A 41 A 25 A 10 A 25 A 14 lb-in 1.2 Nm 14 lb-in 14 lb-in 1.2 Nm 14 lb-in CDS6U/FT Terminal Block is a standard feed through Terminal Block. Other Approvals In the CDS6U/SC Disconnect & Test Terminal Block, an additional safety spring is provided underneath the screw clamp. These Terminal Blocks are preferred for connections that involve safety requirements of the Electric Supply Industry (ESI) standards, British CEGB regulations and NTPC applications. The SLS2 and SLS4 slide shorting link can be used in combination with either the supplied screw or the TPSLS Test point screw system. Lock out cap LCCDS can be used to lock the center shorting screw, to prevent accidental opening of circuits. Specially designed socket head screws act as test/monitoring points in CDTTU and CDTTU-SH. Important: The disconnecting device is not suitable for interrupting load. The supply must be switched off before operating the slide link/lever. Torque Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CDTTU 50 CDTTU-SH 50 End Plate EPCDTTU 50 EPCDTTU 50 CA702 CA802 50 50 CA702 CA802 50 50 CA710/2 CA710/3 CA710/4 CA710/10 100 50 50 20 CA710/2 CA710/3 CA710/4 CA710/10 100 50 50 20 MT8 100 MT8 100 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper 2 pole 3 pole 4 pole 5pold 10 pole Slide Shortng 2 pole Link 4 pole Insulated Test Socket Gray Red Yellow Blue Black Switchable Link Assembly Lock Out Cap External Jumper Marking Tags 28 CDTTU-SH 2 pole 3 pole 4 pole 10 pole Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Disconnect and Test Terminal Blocks CDS6U CDS6U/TS CDS6U/FT NEW CDS6U/SC NEW NEW 8 mm 8 mm 6 mm 6 mm 50 x 82 mm 50 x 82 mm 50 x 82 mm 50 x 82 mm 10 mm 10 mm 10 mm 10 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 2 screw clamps 2 screw clamps 2 screw clamps 2 screw clamps 60947-7-1 E220514 22-8 AWG 0.2-6 sq.mm 22-8 AWG 600 V 800 V 45 A 14 lb-in Cat. No. 60947-7-1 E220514 22-8 AWG 0.2-6 sq.mm 22-8 AWG 600 V 600 V 1000 V 41 A 45 A 45 A 0.8 Nm 14 lb-in 14 lb-in 60947-7-1 E220514 22-8 AWG 0.2-6 sq.mm 22-8 AWG 600 V 600 V 630 V 41 A 45 A 45 A 0.8 Nm 14 lb-in 14 lb-in Std. Pk. Cat. No. Std. Pk. Cat. No. 60947-7-1 E220514 22-8 AWG 0.2-6 sq.mm 22-8 AWG 600 V 600 V 800 V 600 V 41 A 45 A 45 A 41 A 45 A 0.8 Nm 14 lb-in 14 lb-in 0.8 Nm 14 lb-in Std. Pk. Cat. No. Std. Pk. CDS6U 50 CDS6U/TS 50 CDS6U/FT 50 CDS6U/SC 50 EPCDS6U 50 EPCDS6U 50 EPCDS6U 50 EPCDS6U 50 CA702 CA802 50 50 CA702 CA802 50 5 CA702 CA802 50 5 CA702 CA802 50 5 CA723/2 CA723/3 CA723/4 CA723/5 CA723/10 100 50 50 50 10 CA723/2 CA723/3 CA723/4 CA723/5 CA723/10 100 50 50 50 10 CA723/2 CA723/3 CA723/4 CA723/5 CA723/10 100 50 50 50 10 CA723/2 CA723/3 CA723/4 CA723/5 CA723/10 100 50 50 50 10 SLS2 SLS4 50 25 SLS2 SLS4 50 25 SLS2 SLS4 50 25 TPSLS TPSLSR TPSLSY TPSLSBU TPSLSBK 100 100 100 100 100 TPSLSR TPSLSY TPSLSBU TPSLSBK 100 100 100 100 TPSLS TPSLSR TPSLSY TPSLSBU TPSLSBK 100 100 100 100 100 SWCDS 50 SWCDS 50 SWCDS 50 SWCDS 50 LCCDS 50 LCCDS 50 LCCDS 50 LCCDS 50 MT8 100 MT8 100 MT8 100 MT8 100 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 29 Usage of CDS6U range of products in Simple Current Transformer Test Circuit 4 3 2 1 Operating status No. 1 2 3 4 Cat. No. CDS6U SLS2 EPCDS6U LCCDS Meter test for L1 through external power supply A 1 Qty . 2 1 1 1 A 2 1 2 1 2 1 2 S1 S2 S1 S2 SLS2 in open condition L1 Closing of SLS2 L1 Sequence for test : 1) Close short circuit slide SLS2 of terminals 1 and 2. 2) Open disconnect slide link of terminal 2. 3) Connect external power supply to test sockets of terminals 1 and 2. Comparison measurement for L1 Changing the meter for L1 A A 1 2 1 2 1 2 1 2 S1 S2 S1 S2 A L1 SLS2 in open condition Sequence for test : 1) Remove SLS2 screw from terminal 2. 2) Connect ammeter to test sockets of terminal 2. 3) Open disconnect slide link of terminal 2. 30 L1 Closing of SLS2 Sequence for test : 1) Close short circuit slide SLS2 of terminals 1 and 2. 2) Open disconnect slide link of terminal 2. 3) Disconnect meter for L1 at terminals 1 and 2. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Usage of CDS6U range of products in 3 Phase Current Transformer Test Set 1 Usage of CDS6U range of products 3 Phase Linked Current Transformer Test Set 1 5 5 2 4 4 3 3 A A 2 2 1 1 A A 1 2 3 4 5 6 S1 S2 S1 S2 S1 S2 Operating status (with internal distribution of the k-point) A A 1 2 3 4 S1 S2 S1 S2 L2 5 6 S1 S2 L3 SLS2 in open condition L1 2 Operating status SLS4 in open condition L2 L3 L1 A 1 A 2 3 Comparison measurement for L1 A 4 5 A S1 S2 S1 S2 A 6 S1 S2 1 Sequence for test : 1) Remove SLS2 screw from terminal 1. 2) Connect ammeter to test sockets of terminal 1 and 2. 3) Open disconnect slide link of terminal 1. A 2 Comparison measurement for L1 A 3 4 5 6 A S1 S2 S1 S2 S1 S2 Sequence for test : 1) Remove SLS4 screw from terminal 1. 2) Connect ammeter to test sockets of terminal 1 and 5. 3) Open disconnect slide link of terminal 1. L3 L1 L2 L2 L3 L1 A 1 A 2 S1 S2 3 A 4 S1 S2 L1 5 A 6 S1 S2 L2 L3 Meter test for L1 through external power supply Sequence for test : 1) Close short circuit slide SLS2 of terminals 1 and 2. 2) Open disconnect slide link of terminal 1. 3) Connect external power supply to test sockets of terminals 1 and 2. 1 A 2 S1 A 3 S2 4 S1 S2 5 S1 6 S2 L3 L2 Meter test for L1 through external power supply Sequence for test : 1) Close short circuit slide SLS4 of terminals 1,2, 3 and 4. 2) Open disconnect slide link of terminal 1. 3) Connect external power supply to test sockets of terminals 1and 5. L1 A 1 S1 A 2 S2 L1 3 S1 Changing the meter for L1 A 4 S2 L2 5 S1 6 S2 L3 A 1 Sequence for test : 1) Close short circuit slide SLS2 of terminals 1 and 2. 2) Open disconnect slide link of terminal 1. 3) Disconnect meter for L1. S1 A 2 S2 Changing the meter for L1 A 3 S1 4 S2 5 S1 L3 L2 6 S2 Sequence for test : 1) Close short circuit slide SLS4 of terminals 1,2, 3 and 4. 2) Open disconnect slide link of terminal 1. 3) Disconnect meter for L1. L1 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 31 Usage of CDS6U range of products in 3 Phase Power Meter (KWh Meter) Test Set 5 4 No. 1 2 3 4 5 3 2 1 Operating status (with internal distribution of the k-point) KW/h 1 7 KW/h 2 3 8 5 9 KW/h 6 10 1 7 KW/h 2 3 8 KW/h 4 5 9 6 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 S1 S2 S1 S2 S1 S2 L1 L2 L3 N S1 S2 S1 S2 S1 S2 L1 L2 L3 N L1 L2 Qty . 10 3 4 1 1 Meter test for L1 through external power supply KW/h 4 Cat. No. CDS6U SLS2 LCCDS CA723/5 EPCDS6U L1 L1 L1 L2 L2 L3 L2 L3 L3 N L3 N SLS2 in open condition PE Closing of SLS2 PE Sequence for test : 1) Close short circuit slide SLS2 of terminals 1 and 2. 2) Open disconnect slide link of terminal 2 and 7. 3) Connect external power supply to test sockets of terminals 1, 2 and 7, 10. Changing the meter for L1 Comparison measurement for L1 KW/h 1 1 7 2 2 KW/h 3 3 8 KW/h 4 5 4 5 9 6 6 KW/h 10 7 1 8 9 10 A 2 KW/h 3 8 KW/h 4 5 9 6 10 1 2 3 4 5 6 7 8 9 10 S1 S2 S1 S2 S1 S2 L1 L2 L3 N V S1 S2 S1 S2 S1 S2 L1 L2 L3 N L1 L2 L3 N L1 L1 L2 L2 L3 L3 SLS2 in open condition PE Sequence for test : 1) Remove SLS2 screw from terminal 2. 2) Connect ammeter to test sockets of terminal 2. 3) Open disconnect slide link of terminal 2. 4) Connect voltameter to test sockets of terminals 7 and 10. 32 7 N L1 L2 L3 Closing of SLS2 PE Sequence for test : 1) Close short circuit slide SLS2 of terminals 1 and 2. 2) Open disconnect slide link of terminal 2 and 7. 3) Disconnect meter for L1 at terminals 1, 2 and 7. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Altech’s popular industrial enclosures keep you covered with their high quality and attractive design. All at Very Competitive Prices ... and many available for immediate delivery! Customization available! • • • • • • • 16 different enclosures with up to 3 different cover heights • Polystyrene or Polycarbonate • IP66 (NEMA 4X) • 50 x 52 x 35 to 360 x 254 x 165 mm • • • • • Polycarbonate/Polystyrene enclosures will last indefinitely without corrosion Non-metallic enclosures withstand bumps and blows, they will not dent Surface finish does not deteriorate and requires no special painting or refinishing Resist weak and strong acids and alkali Non-metallic enclosures weigh significantly less than metal, simplifying handling Enclosures can be easily customized 16 sizes available ABS or Polycarbonate IP67 (NEMA TYPE 4X) Recesed Cover 84 x 82 x 55 to 302 x 232 x 110 mm • IP65 protection, which is necessary for industry approval. • Aluminum • High degree of resistance to chemcals and other damaging materials. • 50 x 45 x 30 to 330 x 230 x 110 mm • • • • • 6 different sizes For harsh environments Glass reinforced Polycarbonate Impervious to sea air and water 80 x 80 x 52 to 250 x 250 x 115 mm • Low and high covers in gray or tinted transparent • Enclosures are combinable • IP65 protection • 150 x 300 x 132 to 600 x 300 x 210 mm • • • • • UL listed IP65 protection Dust and moisture proof Polycarbonate 130 x 94 x 80 to 361 x 254 x 110 mm • • • • • Junction boxes IP55 protection Dust and moisture proof Semi rigid polypropylene 75 x 75 x 42 to 199 x 149 x 70 mm • Universal fit for nearly all 22.5mm diameter push buttons • UV, weather and impact resistant • IP66 (NEMA 4X) capabile • 94 x 94 x 81 to 180 x 94 x 81 mm • Liquid Tight Strain Relief connectors and connector assemblies • Mounting plates • DIN rail support racks • Key locksets, Hinge kits and more • Two to four high grade self taping screws secure the lid non-flammable • non-flammable Polystyrene • Tongue and groove sealing system with polyurethane gasket • 80 x 80 x 52 to 250 x 250 x 115 mm • • • • • IEC protection Up to IP65 protection Dust and moisture proof Polystyrene or Polycarbonate 100 x 150 x 96 to 900 x 300 x 142 mm Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 33 Distribution Block Altech CDB Compact Distribution Blocks are an ideal choice for a simplified distribution system. A lug/bolt secures the incoming cable and the screw clamp design of the block provides the outgoing connections. These provide easy connect points and ensure perfect continuity for distribution. A protective shield effectively shrouds the incoming connection. Application Information: Sum of outgoing currents on either side of center should not exceed half the maximum permissible incoming current. Sum of total outgoing currents should not exceed maximum permissible incoming current. Connection for higher outgoing currents should be done through the terminal nearest to the incoming connection. CDB4/x(1)** CDB4/x* Terminal Width 6 mm 6 mm Height & Width 45 x 43 mm 45 x 43 mm Stripping Length 8 mm 8 mm Insulation Material Polyamide 6.6 Polyamide 6.6 1 Lug/ M5 bolt connection for ring lug Screw clamp connection 1 Lug M5 /bolt connection for ring lug Screw clamp connection Type of Connection Input Output Approvals 60947-7-1 E220514 10-8 AWG 22-12 AWG 6-16 sq.mm 0.2-4 sq.mm 10-8 AWG 22-10 AWG Voltage Rating 600 V 800 V Input Current Rating Max. Individual Output 50 A 25 A 26 lb-in 7 lb-in Wire Range Torque Input Output Input Output 60947-7-1 E220514 10-8 AWG 22-12 AWG 6-16 sq.mm 0.5-4 sq.mm 10-8 AWG 22-10 AWG 600 V 600 V 800 V 600 V 64 A 32 A 50 A 35 A 50 A 25 A 64 A 64 A 50 A 35 A 2.0 Nm 0.5 Nm 26 lb-in 7 lb-in 26 lb-in 7 lb-in 2.0 Nm 0.5 Nm 26 lb-in 7 lb-in Other Approvals Terminal Block Cat. No. H x W x L (mm) Outputs Std.Pk. Cat. No. CDB4/1 CDB4/2 CDB4/3 CDB4/4 CDB4/5 CDB4/6 45 x 43 x 44 45 x 43 x 56 45 x 43 x 68 45 x 43 x 80 45 x 43 x 96 45 x 43 x 108 CDB4/2(1) 45 x 43 x 52 CDB4/3(1) 45 x 43 x 58 CDB4/4(1) 45 x 43 x 64 CDB4/5(1) 45 x 43 x 70 CDB4/6(1) 45 x 43 x 76 CDB4/10(1)45 x 43 x 100 CDB4/11(1) 45 x 43 x 106 4 8 12 16 20 24 10 10 10 10 10 10 H x W x L (mm) Outputs Std.Pk Cat. No. Std. Pk. End Stop for ordering information refer to page 92 CA702 CA802 50 50 CA702 CA802 50 50 Marking Tags MT6 100 MT6 100 Cat. No. 6 8 10 12 14 22 24 10 10 10 10 10 10 10 Std. Pk. DIN Rail for ordering information refer to pages 90-91 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Warning Label Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 34 * NOTE: x signifies how many blocks are on each side of input. ** NOTE: x signifies number of blocks on left side of input. 1 block is on right side. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Distribution Block CDB6/x* CDB10/x* CDB25/x* 8 mm 10 mm 12 mm 43 x 47 mm 43 x 47 mm 56 x 49 mm 12 mm 12 mm 18 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 1 Lug/ M6 bolt connection for ring lug Screw clamp connection 1 Lug/ M8 bolt connection for ring lug Screw clamp connection 1 Lug/ M8 bolt connection for ring lug Screw clamp connection 60947-7-1 E220514 10-2 AWG 22-8 AWG 6-25 sq.mm 1.5-6 sq.mm 10-2 AWG 22-8 AWG 600 V 800 V 100 A 50 A 35 lb-in 14 lb-in Cat. No. 60947-7-1 E220514 8-1/0 AWG 22-6 AWG 10-35 sq.mm 1.5-10 sq.mm 8-1/0 AWG 16-6 AWG 600 V 600 V 800 V 82 A 41 A 100 A 50 A 130 A 65 A 3.0 Nm 0.8 Nm 35 lb-in 14 lb-in 53 lb-in 14 lb-in H x W x L (mm) Outputs Std.Pk CDB6/2 43 x 47 x 64 CDB6/3 43 x 47 x 80 CDB6/4 43 x 47 x 96 8 12 16 10 10 5 Cat. No. 60947-7-1 E220514 6-2/0 AWG 12-2 AWG 10-50 sq.mm 6-25 sq.mm 6-2/0 AWG 12-2 AWG 600 V 600 V 800 V 600 V 114 A 57 A 130 A 65 A 150 A 75 A 150 A 75 A 150 A 75 A 6.0 Nm 1.2 Nm 53 lb-in 14 lb-in 53 lb-in 22 lb-in 6.0 Nm 2 Nm 53 lb-in 22 lb-in H x W x L (mm) Outputs Std.Pk CDB10/2 43 x 47 x 72 CDB10/3 43 x 47 x 92 CDB10/4 43 x 47 x 112 8 12 16 10 10 5 Cat. No. H x W x L (mm) Outputs Std.Pk CDB25/2 CDB25/3 CDB25/4 56 x 49 x 88 8 56 x 49 x 112 12 56 x 49 x 136 16 Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 MT8 100 MT10 100 MT12 100 SWL6 100 10 10 5 * NOTE: x signifies how many blocks are on each side of input. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 35 Distribution Block CMDB blocks are the modified version of CDB terminal blocks without central incoming terminal connections. CMDB4/x CMDB6/x CMDB10/x Terminal Width 6 mm 8 mm 10 mm Height & Width 45 x 43 mm 43 x 47 mm 43 x 47 mm Stripping Length 9 mm 12 mm 12 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Type of Connection Screw clamp connection Screw clamp connection Screw clamp connection Approvals E220514 60947-7-1 E220514 60947-7-1 E220514 60947-7-1 0.2-4 sq.mm 22-10 AWG 1.5-6 sq.mm 22-8 AWG 1.5-10 sq.mm 22-6 AWG Voltage Rating 1000 V 600 V 1000 V 600 V 1000 V 600 V Current Rating 32 A 35 A 41 A 50 A 57 A 65 A 0.5 Nm 7 lb-in 0.8 Nm 14 lb-in 1.2 Nm 14 lb-in Wire Range Torque Other Approvals Cat. No. Terminal Block CMDB4/2 CMDB4/3 CMDB4/4 CMDB4/10 H x W x L Outputs (mm) 45 x 43 x 13.5 4 45 x 43 x 19.5 6 45 x 43 x 25.5 8 45 x 43 x 61.5 20 Std. Pk. 10 10 5 5 Cat. No. H x W x L Outputs (mm) CMDB6/2 43 x 48 x 17.5 4 CMDB6/3 43 x 48 x 25.5 6 CMDB6/4 43 x 48 x 33.5 8 CMDB6/10 43 x 48 x 81.5 20 Std. Pk. 10 10 10 5 Cat. No. CMDB10/2 CMDB10/3 CMDB10/4 CMDB10/10 H x W x L Outputs Std. (mm) Pk. 43 x 48 x 21.5 4 10 43 x 48 x 31.5 6 10 43 x 48 x 41.5 8 10 43 x 48 x 101.5 20 5 Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. End Stop for ordering information refer to page 92 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 Marking Tags MT6 100 MT8 100 MT10 100 SWL6 100 DIN Rail for ordering information refer to pages 90-91 Warning Label COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 36 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com We have a full line of standard and custom Interface Modules and Power Supplies. CONNECTOR TO TERMINAL BLOCK MODULES GENERAL PURPOSE/ INTERFACE RELAYS Compact and reliable connections between high density connectors and high quality screw-cage clamp terminal blocks; DIN Rail mountable A selection of DIN Rail mountable general purpose relays available for up to 12 A @ 250 Volts. DIODE MODULES & COMPONENT CARRIERS PLUGGABLE SLIMLINE RELAYS Add additional components to build circuits and diode modules mounted on 35 or 32mm DIN Rails. Need Text MONITORING PROTECTION MODULES I/O MODULE CARRIERS Special purpose components connected to screw-cage clamp terminal blocks; DIN Rail mountable. Accepts industry standard I/O modules. LED indicator and fuse protection included on carrier. RELAY MODULES SOLID STATE I/O MODULES Traditional relay modules from 1-16 channels. Available in several voltages (AC & DC), isolated or bussed systems. DIN Rail mounted. Input/Output Modules (both AC and DC) provided on a DIN mountable module. Bussed and isolated versions available. SAFETY RELAY MODULES POWER SUPPLIES Force-guided contact modules available in 1-16 channels, 12 and 24VDC coils and isolated or bussed systems. All mountable on 32 or 35mm DIN Rails. Basic and High Performance Series. DIN Rail mountable units are available with 12 or 24VDC output, 15 to 60 Watts and regulated outputs. CUSTOM MODULES MOUNTING TRACKS Altech provides quick turn-key custom designs and competitive solutions. DIN Rail or panel mount mounting tracks secure standard or custom printed circuit boards in control panels or cabinets. Contact Altech Today to learn more! Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 37 One Phase Power Distribution Block • Quick mounting and wiring • IP20 Finger Safe • DIN Rail or Panel Mount • Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm) • Accessories increase the number of outputs with only one input (applies only to 38041 and 38032) • No caps to open / remove • Material Housing: Polyamide Metal Body: Brass Part Number: DB16 38049 DB35 38041 DB16* 38049 DB35* 38041 Approvals UL File E220514 UL File E98082 UL File E220514 UL File E98082 Current Rating 80A 80A 80A 80A 115A 125A 115A 125A Voltage Rating 600V AC 1000V AC 600V AC 690V AC 600V AC 1000V AC 600V AC 690V AC SCCR 10kA No. of Inputs Wire Range Torque Screw Type No. of Outputs Wire Range Torque Wire Range Torque Screw Type Optional Marking Tag **(for DB16 and DB35) 1 8-4 AWG 14lb.-in. 100kA 1 6-16mm2 1.2Nm Pozi Drive 2 6 6 (2x)8-4 AWG (2x)6-16mm2 14lb.-in. 12Nm (4x)14-10 AWG (4x)2.5-6mm2 7lb.-in. 7Nm Pozi Drive 2 MT2** 1 8-4 AWG 14lb.-in. 10kA 1 6-16mm2 1.5Nm Pozi Drive 2 6 6 (2x)8-4 AWG (2x)6-16mm2 14lb.-in. 1.5Nm (4x)14-10 AWG (4x)2.5-6mm2 7.2lb.-in. 0.8Nm Pozi Drive 2 1 8-2 AWG 40lb.-in. 100kA 1 10-35mm2 6Nm Pozi Drive 2 6 6 14-6 AWG 2.5-10mm2 17.5lb.-in. 2Nm 8-4 AWG 6-16mm2 14lb.-in. 3Nm Pozi Drive 2 1 8-2 AWG 13.5lb.-in. 1 10-35mm2 3.5Nm Pozi Drive 2 6 6 14-6 AWG 2.5-16mm2 17.5lb.-in. 2Nm Pozi Drive 2 MT2** Dimensions: COLOR BLOCKS (other than standard grey) 38041 Fork Type Busbar 38045 When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 38 38041 Accessories: Fork Type Busbar Part No: 38045 to jump 2 Blocks 38046 to jump 8 Blocks can be cut Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com One Phase Power Distribution Block 38076 38076 Part Number: 38032 38074 38032 38074 Approvals UL File E98082 UL File E98082 UL File E98082 Current Rating 115A 125A 160A 160A 175A 175A Voltage Rating 600V AC 690V AC 600V AC 690V AC 600V AC 690V AC SCCR No. of Inputs Wire Range Torque Screw Type No. of Outputs Wire Range Torque Screw Type 100kA 1 8-2 AWG 53lb.-in. 100kA 1 10-35mm2 6Nm 1 8-2/0AWG 35.5lb.-in. 10 2.5-16mm2 3Nm 6 14-6 AWG 17.5lb.-in. Hex 4 10 14-4 AWG 26.5lb.-in. 100kA 1 10-70mm2 4Nm 1 6-2/0AWG 53lb.-in. 6 2.5-16mm2 2Nm 10 14-4 AWG 26.5lb.-in. Hex 5 Hex 3 1 16-70mm2 6Nm Hex 5 Hex 3 10 2.5-16mm2 3Nm Hex 3 Dimensions: 58 mm (2.28 in) 58 mm (2.28 in) 5.2 mm (0.20 in) 71 mm (2.80 in) 19.9 mm (0.78 in) 5.2 mm (0.20 in) 71 mm (2.80 in) 19.9 mm (0.78 in) 38.5 mm (1.52 in) 38.5 mm (1.52 in) 5.2 mm (0.20 in) 5.2 mm (0.20 in) 13.8 mm (0.54 in) 17.4 mm (0.69 in) 43 mm (1.69 in) 13.8 mm (0.54 in) 17.4 mm (0.69 in) 43 mm (1.69 in) 45 mm (1.77 in) 45 mm (1.77 in) 38032 38032 Copper Jumper Bar 3803221 Accessories: Copper Jumper Bar (6x15 mm) Part No: 3803221 for 2 Blocks 3803231 for 3 Blocks 3803241 for 4 Blocks can be cut Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 39 One Phase Power Distribution Block • • • • Quick mounting and wiring IP20 Finger Safe DIN Rail or Panel Mount Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm) • Accessories increase the number of outputs with only one input. • No caps to open or remove • Material Housing: Polyamide Metal Body: Brass 38019 38020 38020 Part Number: 38019 Approvals UL File E98082 UL File E98082 Current Rating 230A 250A 310A 400A Voltage Rating 600V AC 690V AC 600V AC 690V AC SCCR No. of Inputs Wire Range Torque Screw Type No. of Outputs Wire Range Torque Wire Range Torque Wire Range Torque Screw Type 100kA 1 2-4/0AWG 170lb.-in. 100kA 1 35-120mm2 19Nm Hex 6 11 11 (2x) 14-2AWG (2x) 2.5-35mm2 31lb.-in. 3.5Nm (5x) 14-6AWG (5x) 2.5-16mm2 17.5lb.-in. 2Nm (4x) 14-8AWG (4x) 2.5-10mm2 17.5lb.-in. 2Nm standard screwdriver 1 3/0-350mcm 230lb.-in. 1 95-185mm2 25Nm Hex 8 11 11 (2x) 14-2AWG (2x) 2.5-35mm2 31lb.-in. 3.5Nm (5x) 14-6AWG (5x) 2.5-16mm2 17.5lb.-in. 2Nm (4x) 14-8AWG (4x) 2.5-10mm2 17.5lb.-in. 2Nm standard screwdriver Dimensions: 40 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Three Phase Power Distribution Block 38073 38075 • • • • Quick mounting and wiring IP20 Finger Safe DIN Rail or Panel Mount Blocks fit with other DIN Rail mountable modular devices • Same compact size for both ratings • No caps to open or remove • Material Housing: Polyamide Metal Body: Brass 3 Pole 3 Pole 38075 Part Number: 38073 Approvals UL File E98082 UL File E98082 Current Rating 115A 115A 175A 175A Voltage Rating 600V AC 690V AC 600V AC 690V AC SCCR No. of Inputs Wire Range Torque Screw Type No. of Outputs Wire Range Torque Screw Type 100kA 3x1 8-2AWG 31lb.-in. 100kA 3x1 10-35mm2 3.5Nm 3x1 8-2/0AWG 35.5lb.-in. 3x6 2.5-16mm2 2Nm 3x6 14-4AWG 17.5 lb.-in. Hex 4 3x6 14-4AWG 17.5lb.-in. Hex 3 3x1 10-70mm2 4Nm Hex 5 3x6 2.5-16mm2 2Nm Hex 3 Dimensions: Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 41 Splicer Blocks • Quick mounting and wiring • IP20 Finger Safe • DIN Rail or Panel Mount • No caps to open or remove • Material Housing: Polyamide Metal Body: Aluminum Part Number: 38064 38057 38059 38064 38057 38059 Approvals UL File E98082 UL File E98082 UL File E98082 Current Rating 175A 175A 335A 400A 840A 800A Voltage Rating 600V AC 690V AC 600V AC 690V AC 600V AC 690V AC No. of Inputs Wire Range Torque Screw Type No. of Outputs Wire Range Torque Screw Type 1 14-1AWG 106.2lb.-in. 1 2.5mm2-50mm2 12Nm Hex 5 1 1 14-1AWG 2.5mm2-50mm2 106.2lb.-in. 12Nm Hex 5 1 1 2 2 6AWG-400MCM 16mm2-185mm2 3AWG-600MCM 25-300mm2 221lb.-in. 25Nm 310lb.-in. 35Nm Hex 10 Hex 10 1 1 2 2 6AWG-400MCM 16mm2-185mm2 3AWG-600MCM 25-300mm2 221lb.-in. 25Nm 310lb.-in. 35Nm Hex 10 Hex 10 Dimensions: 145 mm [5.71 in] 124.4 mm [4.90 in] 145.5 mm [5.73 in] 72.3 mm (2.85 in) 34.7 mm (1.37 in) 43.2 mm (1.70 in) 59.6 mm (2.35 in) 53.5 mm [2.11 in] 80.5 mm [3.17 in] 129 mm [5.08 in] 39 mm [1.54 in] 7 mm [0.28 in] 7.5 mm [0.30 in] 25.4 mm (1.0 in) 50 mm (1.97 in) 7 mm [0.28 in] 12 mm [0.47 in] 42 72 mm [2.83 in] 80.5 mm [3.17 in] Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Thermocouple Blocks CTT2.5UK/J/T/E Altech thermocouple terminal blocks are designed for use in temperature measuring circuits. The current carrying part of the terminal blocks have the same material (according to DIN437134 and DIN43714) which is used for compensating cables in the temperature measurement circuit (up to 200°C). The terminal block is marked for the respective type of thermocouple which enables easy identification for wiring. Terminal Width 10 mm Height x Length 45 x 43 mm Stripping Length 8 mm Polyamide 6.6 Insulation Material Current Carrying Material * • CTT2.5UK ‘K’ type Chromel (NiCr) Alumel (NiAl) • CTT2.5UJ ‘J’ type Iron (Fe) Constantan (CuNi) Type of Connection * 4 screw clamps 24-12 AWG Wire Range Voltage Rating 300 V Current Rating 10 A 7 lb-in Torque Cat. No. Std. Pk. • CTT2.5UT ‘T’ type Copper (Cu) Constantan (CuNi) Terminal Block • CTT2.5UE ‘E’ type Chromel (NiCr) Constantan (CuNi) CTT2.5UK CTT2.5UJ CTT2.5UT CTT2.5UE 50 50 50 50 End Plate EP2.5/4UN 50 Isolation Plate PP2.5/4UN 50 End Clamp CA802 CA702 100 100 Marking Tags (MT Type) included DIN Rail for ordering information refer to page 63 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 43 Indicator/ Diode Circuit CDL4U(E)D1/D2 Altech offers different types of terminals incorporating electronic components for signal converting, circuit protection and status indication. Based on customer requirements, specially assembled terminals are offered. CDL4U(E)D3 With arc suppression circuit for contactors and solenoid valves - DC Diode circuit for reverse polarity protection Terminal Width 6 mm 6 mm Height x Length 54 x 55.5 mm 54 x 55.5 mm Terminal Voltage 300 V~ 300 V~ Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Approvals 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm Wire Range 60947-7-1 E220514 22-10 AWG 22-10 AWG 0.2-4 sq.mm 22-10 AWG Voltage Rating 300 V 500 V 600 V 300 V 500 V 600 V Current Rating 25 A 32 A 35 A 25 A 32 A 35 A 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Torque Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CDL4U(E)D1 CDL4U(E)D2 100 100 CDL4U(E)D3 100 End Plate EPCDL4U 50 EPCDL4U 50 CA702 CA802 50 50 CA702 CA802 50 50 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA703/1 CA704/2 CA705/3 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/2 CA705/3 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper 2 pole 3 pole 4 pole 10 pole Current Bars 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Shorting Sleeve & Screw CA607/S/Q 100 CA607/S/Q 100 Example for color Red: Cat.No./R Marking Tags MT2 100 MT2 100 Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 1 2 1 2 C 3 4 Diode Specifications Diode 1N 4007 3 4 C D3 D1 1 2 Diode Reverse Voltage 1000 V Diode Current 1A C 3 4 D2 44 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Indicator/ Diode Circuit CDL4U(E)DD1/DD2 CDL4U(E)DD3/DD4 Diode circuit for lamp testing CDL4U(E)D4 Diode circuit for lamp testing CDL4U(E)DD5 Diode circuit for lamp testing with LED series resistance Diode circuit for lamp testing with LED series resistance 6 mm 6 mm 6 mm 6 mm 54 x 55.5 mm 54 x 55.5 mm 54 x 55.5 mm 54 x 55.5 mm 300 V~ 300 V~ 12V~/24 V~ 12V~/24 V~ 9 mm 9 mm 9 mm 9 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 E220514 60947-7-1 22-10 AWG 0.2-4 sq.mm 22-10 AWG E220514 60947-7-1 22-10 AWG 0.2-4 sq.mm 22-10 AWG E220514 60947-7-1 22-10 AWG 0.2-4 sq.mm 22-10 AWG E220514 60947-7-1 22-10 AWG 0.2-4 sq.mm 22-10 AWG 300 V 500 V 600 V 300 V 500 V 600 V 300 V 500 V 600 V 300 V 500 V 600 V 25 A 32 A 35 A 25 A 32 A 35 A 25 A 32 A 35 A 25 A 32 A 35 A 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. CDL4U(E)DD1 CDL4U(E)DD2 100 100 CDL4U(E)DD3 CDL4U(E)DD4 100 100 CDL4U(E)D4 100 CDL4U(E)DD5 100 EPCDL4U 50 EPCDL4U 50 EPCDL4U 50 EPCDL4U 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA607/S/Q 100 CA607/S/Q 100 CA607/S/Q 100 CA607/S/Q 100 MT2 100 MT2 100 MT2 100 MT2 100 1 C C C 3 +4 +4 DD3 -4 DD2 C C 3 2 +4 3 C +4 DD5 2 C C 1 2 D4 1 2 C 1 C +3 DD1 1 3 2 1 2 +3 C +4 DD4 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 45 Indicator/ Diode Circuit CDL4U(E)N1 CDL4U(E)LD5* CDL4U(E)LD3* AC voltage indicator with neon lamp AC voltage indicator with LED AC/ DC voltage indicator with LED Terminal Width 6 mm 6 mm 6 mm Height x Length 54 x 55.5 mm 54 x 55.5 mm 54 x 55.5 mm Terminal Voltage 110 V~ to 220 V~ 24 V~, 48 V~, 120V~, 220V~ 12 V~, 24 V~ Stripping Length 9 mm 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Approvals E220514 60947-7-1 22-10 AWG Wire Range 0.2-4 sq.mm 22-10 AWG E220514 60947-7-1 22-10 AWG 0.2-4 sq.mm 22-10 AWG 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG Voltage Rating 300 V 500 V 600 V 300 V 500 V 600 V 300 V 500 V 600 V Current Rating 25 A 32 A 35 A 25 A 32 A 35 A 25 A 32 A 35 A 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Torque Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CDL4U(E)N1 50 CDL4U(E)LD5* 50 CDL4U(E)LD3* 50 End Plate EPCDL4U 50 EPCDL4U 50 EPCDL4U 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 Shorting Sleeve & Screw CA607/S/Q 100 CA607/S/Q 100 CA607/S/Q 100 Marking Tags MT2 100 MT2 100 MT2 100 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering information refer to page 92 Internal Jumper 2 pole 3 pole 4 pole 10 pole Current Bars 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole 2 1 3 +1 1 4 N1 3 C LD5 4 +3 +4 LD3 * Add required voltage to part number as a suffix i.e. CDL4U(E)LD5/110 is for 110V. 46 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Indicator/ Diode Circuit CDL4U(E)LD4* CDL4U(E)LD1/LD2 AC/ DC voltage indicator with LED DC voltage indicator with LED CDL4U(E)L1/L2* CDL4U(O) DC voltage indicator with LED Electronic Component Carrier 6 mm 6 mm 6 mm 6 mm 54 x 55.5 mm 54 x 55.5 mm 54 x 55.5 mm 54 x 55.5 mm 24V~, 48 V~ 24 V– 6 V–, 24 V–, 60 V– 9 mm 9 mm 9 mm 9 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 60947-7-1 E220514 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 300 V 500 V 25 A 7 lb-in 22-10 AWG 0.2-4 sq.mm 22-10 AWG 600 V 300 V 500 V 32 A 35 A 25 A 0.5 Nm 7 lb-in 7 lb-in Cat. No. Std. Pk. 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 600 V 300 V 500 V 32 A 35 A 25 A 0.5 Nm 7 lb-in 7 lb-in Cat. No. Std. Pk. 60947-7-1 E220514 22-10 AWG 0.2-4 sq.mm 22-10 AWG 600 V 300 V 500 V 600 V 32 A 35 A 25 A 32 A 35 A 0.5 Nm 7 lb-in 7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. Cat. No. Std. Pk. CDL4U(E)LD4* 50 CDL4U(E)LD1 CDL4U(E)LD2 50 50 CDL4U(E)L1* CDL4U(E)L2* 50 50 CDL4U(O) 100 EPCDL4U 50 EPCDL4U 50 EPCDL4U 50 EPCDL4U 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA727/2 CA727/3 CA727/4 CA727/10 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA703/1 CA704/1 CA705/1 CA732/10 CA732/10-A CA732/100 100 100 100 100 100 10 CA607/S/Q 100 CA607/S/Q 100 CA607/S/Q 100 CA607/S/Q 100 MT2 100 MT2 100 MT2 100 MT2 100 -1 +1 C +3 +1 C +4 -3 -4 -3 -4 LD1 L1 -1 -1 C +3 +4 LD2 +3 +4 L2 * Add required voltage to part number as a suffix i.e. CDL4U(E)LD5/110 is for 110V. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 47 Surge Suppressor In applications where circuit protection against transient overvoltage is required, Altech Surge Suppressor Terminal Blocks with built-in electronic components are recommended. These terminals are designed to protect a single line against a longitudinal (line / earth) surge, thereby protecting distribution and inputs. CDL4U(E)LA CDL4U(E)3LA Lightning Arrestor 3 Pole Lightning Arrestor Terminal Width 12 mm 18 mm Height x Length 54 x 55.5 mm 54 x 55.5 mm Stripping Length 9 mm 9 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 4 screw clamps 4 screw clamps 22-10 AWG 22-10 AWG 75, 90, 230, 600, 1000 V DC 90, 230, 350, 600 V DC 20 KA (8/20µs) 10 KA (8/20µs) – – 100 ns 100 ns 10A 5A Capacitance <1.5 pf <1.0 pf Application For coarse line protection of measuring, distributing or data communication interfaces. For simultaneous protection of lines against transversal (line/line) and longitudinal (line/earth) surge. Wire Range Voltage Rating Nominal Discharge Current Peak Current Response Time Nominal Current Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CDL4U(E)LA75V CDL4U(E)LA90V CDL4U(E)LA230V CDL4U(E)LA600V CDL4U(E)LA1000V 20 20 20 20 20 CDL4U(E)3LA90V CDL4U(E)3LA230V CDL4U(E)3LA350V CDL4U(E)3LA600V 20 20 20 20 End Plate EPCDL4U 50 EPCDL4U 50 End Stop for ordering information refer to page 92 CA702 CA802 50 50 CA702 CA802 50 50 Marking Tags MT2 100 MT2 100 DIN Rail for ordering information refer to page 80-81 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 48 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Surge Suppressor CDL4U(E)MOV1 MOV CDL4U(E)RC CDL4U(E)SD RC Circuit Suppressor Diode 12 mm 18 mm 12 mm 54 x 55.5 mm 54 x 55.5 mm 54 x 55.5 mm 9 mm 9 mm 9 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 4 screw clamps 4 screw clamps 4 screw clamps 22-10 AWG 22-10 AWG 22-10 AWG 250 V AC / 630 V DC 12-48V DC / 12-160V AC** – 20A 1.5 KA 2kA-6.5kA (8/20µs) – – <25ns – 1 ns DC / 5 ns AC – – – 0.1 µf or 0.22 µf – For protection of DC solenoid valves and contactors For fine protection of data interfaces, sensors, contacts, etc. 30, 60, 75, 130, 275, 460, 510, 625, 680 V AC 100-20,000 pf For protection from voltage surge, spikes Cat. No. CDL4U(E)MOV30V CDL4U(E)MOV60V CDL4U(E)MOV75V CDL4U(E)MOV130V CDL4U(E)MOV275V CDL4U(E)MOV460V CDL4U(E)MOV510V CDL4U(E)MOV625V CDL4U(E)MOV680V Std. Pk. 20 20 20 20 20 20 20 20 20 Cat. No. CDL4U(E)RC0.1 CDL4U(E)RC0.22 Std. Pk. 20 20 Cat. No. Std. Pk. CDL4U(E)SDUA15V CDL4U(E)SDUA24V CDL4U(E)SDUA48V CDL4U(E)SDUK15V CDL4U(E)SDUK24V CDL4U(E)SDUK48V CDL4U(E)SDB15V CDL4U(E)SDB24V CDL4U(E)SDB48V CDL4U(E)SDB160V 20 20 20 20 20 20 20 20 20 20 EPCDL4U 50 EPCDL4U 50 EPCDL4U 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 MT2 100 MT2 100 MT2 100 SDUA SDB Note: CDL4U(E)SDU - For D.C. Application CDL4U(E)SDB - For A.C. Application A - Anode K - Cathode SDUK 1 A fuse block is recommended to protect MOV terminals by disconnecting the faulted varistor. See pages 21-25 for fuse blocks. ** Phase to Phase / Phase to ground. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 49 Stud Type Block Altech DIN rail mounting Stud Type Terminal Blocks are preferred for the connections that are subjected to very severe vibrations. CSTSN4U CSTSN5U The wire is crimped to a ring / fork type lug and is screwed on to the flat current bar in terminal. Jumpering can be achieved with the aid of external jumpers. The jumpers are insulated to make them shock proof. The terminal blocks have marker holding recess to accommodate marking tags. It is recommended to use protective covers in transparent plastic because assemblies of these terminals blocks are not fully covered. Terminal Width 17 mm 17 mm Height x Length 39.5 x 50 mm 39.5 x 50 mm Stripping Length 12 mm 12 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Type of Connection 2 screw connection for M4 ring/fork lugs 2 screw connection for M5 ring/fork lugs Approvals 60947-7-1 E220514 22-6 AWG 1.5-10 sq.mm 22-6 AWG Voltage Rating 600 V 1000 V Current Rating 65 A 14 lb-in Wire Range Torque 60947-7-1 E220514 22-4 AWG 1.5-16 sq.mm 22-4 AWG 600 V 600 V 1000 V 600 V 57 A 65 A 80 A 76 A 80 A 1.2 Nm 14 lb-in 25 lb-in 2.0 Nm 25 lb-in Other Approvals Cat. No. Std. Pk. Cat. No. Std. Pk. Terminal Block CSTSN4U 100 CSTSN5U 100 End Plate EPCSTSN5U 50 EPCSTSN5U 50 CA702 CA802 50 50 CA702 CA802 50 50 DIN Rail for ordering information refer to pages 90-91 COLOR BLOCKS (other than standard grey) When ordering please add color suffix to Cat. No. Example for color Red: Cat.No./R Color Red Yellow Blue Green Ordering Suffix R Y BU G Consult Altech for availability: Orange O Beige BG Dark Brown DB Black BL White W 50 End Stop for ordering information refer to page 92 Protective Cover for covering 2 Terminal 3 Terminal CSTSPC1 CSTSPC1-1 100 100 CSTSPC1 CSTSPC1-1 100 100 Protective Cover in Length 100 mm 200 mm 300 mm CSTSPC1-2 CSTSPC1-3 CSTSPC1-4 10 10 10 CSTSPC1-2 CSTSPC1-3 CSTSPC1-4 10 10 10 Insulated Removable Jumpers 2 way 3 way 4 way CA514/1-2 CA514/1-3 CA514/1-4 100 50 50 CA514/1-2 CA514/1-3 CA514/1-4 100 50 50 Insulated Permanent Jumpers 2 way 3 way 4 way CA514/3-2 CA514/3-3 CA514/3-4 100 50 50 CA514/3-2 CA514/3-3 CA514/3-4 100 50 50 MT2B4 100 MT2B4 100 Marking Tags Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Stud Type Block CSTSN6U CSTSB4U CSTSB5U NEW 17 mm 17 mm 17 mm 39.5 x 50 mm 39.5 x 50 mm 39.5 x 50 mm 12 mm 12 mm 12 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 2 screw connection for M5 ring/fork lugs 2 screw connection for M4 ring/fork lugs 2 screw connection for M5 ring/fork lugs 60947-7-1 E220514 22-6 AWG 1.5-10 sq.mm 22-6 AWG 22-4 AWG 1.5-16 sq.mm 22-4 AWG 600 V 600 V 1000 V 600 V 600 V 1000 V 600 V 125 A 125 A 65 A 57 A 65 A 80 A 76 A 80 A 3.0 Nm 25 lb-in 14 lb-in 1.2 Nm 14 lb-in 25 lb-in 2.0 Nm 25 lb-in 60947-7-1 E220514 22-2 AWG 1.5-35 sq.mm 22-2 AWG 600 V 1000 V 125 A 25 lb-in Cat. No. Std. Pk. Cat. No. Std. Pk. 60947-7-1 Cat. No. E220514 Std. Pk. CSTSN6U 100 CSTSB4U 100 CSTSB5U EPCSTSN5U 50 EPCSTN5U 50 EPCSTN5U 50 CA702 CA802 50 50 CA702 CA802 50 50 CA702 CA802 50 50 CSTSPC1 CSTSPC1-1 100 100 CSTSPC1 CSTSPC1-1 100 100 CSTSPC1 CSTSPC1-1 100 100 CSTSPC1-2 CSTSPC1-3 CSTSPC1-4 10 10 10 CSTSPC1-2 CSTSPC1-3 CSTSPC1-4 10 10 10 CSTSPC1-2 CSTSPC1-3 CSTSPC1-4 10 10 10 CA514/1-2 CA514/1-3 CA514/1-4 100 50 50 CA514/1-2 CA514/1-3 CA514/1-4 100 50 50 CA514/1-2 CA514/1-3 CA514/1-4 100 50 50 CA514/3-2 CA514/3-3 CA514/3-4 100 50 50 CA514/3-2 CA514/3-3 CA514/3-4 100 50 50 CA514/3-2 CA514/3-3 CA514/3-4 100 50 50 MT2B4 100 MT2B4 100 MT2B4 100 100 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 51 Hinge Type Stud Block STH4 STH Series Terminal Blocks are preferred for application where the connections are subjected to severe vibration. The wire is crimped to a ring / fork lug and is screwed on to the flat current bar of the Terminal Block. The hinged carrier should be lifted to insert the lugs and then fastened to complete the Terminal Width connection. By virtue of the hinged design, the Terminal Blocks apart from shrouding the live parts, providing IP 20 (Finger Safe) protection, save considerable time in wiring. STH4DTSH 11 mm 11 mm 22 mm Height x Length 50.5 x 46 mm 50.5 x 86 mm 50.5 x 86 mm Stripping Length 10 mm 10 mm 10 mm Insulation Material Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 Type of Connection 2 stud flat connection 2 stud flat connection 2 stud flat connection Stud Size / Operated by M4 / Screwdriver M4 / Screwdriver M4 / Screwdriver Two Lugs can be connectApprovals ed to the Terminal, without sacrificing the safety of the Terminal Block. Wire Range 60947-7-1 60947-7-1 E220514 60947-7-1 E220514 E220514 22-8 AWG 1.5-6 sq.mm 22-8 AWG 22-8 AWG 1.5-6 sq.mm 22-8 AWG 22-8 AWG 1.5-6 sq.mm 22-8 AWG STH4DT Disconnect & Test Terminal Block is used for measuring, control and regulatory circuits. They provide a clear functional advantage for devices having utility instruments and associated transformers. Voltage Rating 600 V 1000 V 600 V 600 V 1000 V 600 V 600 V 1000 V 300 V Current Rating 50 A 41 A 50 A 35 A 41 A 35 A 35 A 34 A 25 A 14 lb-in 1.2 Nm 14 lb-in 14 lb-in 1.2 Nm 14 lb-in 14 lb-in 1.2 Nm 14 lb-in Socket Headed Screws act as test monitoring point on either side of the Terminal Block. Disconnection is achieved by means of a slide link operated with a Screw Driver. STH4DTSH Terminal Block has 2 STH4DT Terminal Block shorted to achieve switchable cross connection (on one side). Note: The disconnecting device is not suitable for interrupting load. The supply must be switched off before operating the slide link / moving the hinged carrier. Torque Other Approvals Cat. No. Std. Pk. Terminal Block STH4 100 STH4DT 100 STH4DTSH 100 End Plate EPSTH4 50 EPSTH4DT 50 EPSTH4DT 50 Cat. No. Std. Pk. Cat. No. Std. Pk. CA702 CA802 100 50 CA702 CA802 100 50 CA702 CA802 100 50 DIN Rail for ordering information refer to pages 90-91 End Stop for ordering info. refer to page 92 Removable Shorting Link 2 way 3 way 4 way CA512/13-2 CA512/13-3 CA512/13-4 100 50 50 CA512/13-2 CA512/13-3 CA512/13-4 100 50 50 CA512/13-2 CA512/13-3 CA512/13-4 100 50 50 Insulated Removable Shorting Link 2 way 3 way 4 way CA514/13-2 CA514/13-3 CA514/13-4 100 50 50 CA514/13-2 CA514/13-3 CA514/13-4 100 50 50 CA514/13-2 CA514/13-3 CA514/13-4 100 50 50 Permanant Shorting Link 2 way 3 way 4 way CA512/14-2 CA512/14-3 CA512/14-4 100 50 50 CA512/14-2 CA512/14-3 CA512/14-4 100 50 50 CA512/14-2 CA512/14-3 CA512/14-4 100 50 50 Insulated Permanent Jumpers 2 way 3 way 4 way CA514/14-2 CA514/14-3 CA514/14-4 100 50 50 CA514/14-2 CA514/14-3 CA514/14-4 100 50 50 CA514/14-2 CA514/14-3 CA514/14-4 100 50 50 MT10 100 MT10 100 MT10 100 Marking Tags 52 STH4DT Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Power Block PTB35/50 / PTB35/50SH PTB series Terminal Blocks are preferred for applications using wires of large cross section. The Wire is crimped to a ring / fork lug and is screwed on to the flat current bar of the Terminal Block. Specially designed Mounting Feet hold the Terminal Block rigidly on to the Mounting Rail. Two Lugs of 35 sq.mm can be connected to the Terminal Block, without sacrificing the safety of the Terminal Block. Hinged Protective Cover makes the Terminal Block shock proof (finger safe) and has marker recess to accept marking tags. PTB35/50SH NEW PTB70/95 / PTB70/95SH PTB70/95SH NEW PTB35/50 PTB70/95 Terminal Width 25 mm 32 mm Height x Length 73.6 x 169 mm 78 x 192 mm Stripping Length 18 mm / M6 18 mm / M6 Insulation Material Polyamide 6.6 Polyamide 6.6 The Terminal Blocks can be stacked together by pressing the adjacent Terminal Blocks firmly. In PTB35SH series Terminal Blocks, adjacent terminals can be shorted by removing a thin wall partition and using 2/3/4 way shorting link. Type of Connection 2 bolts for connection 2 bolts for connection * Optional Marker Holder can be used for installing marking tags on the Terminal Blocks without protective covers. Approvals 60947-7-1 E220514 60947-7-1 E220514 8-2 AWG 1.5-50 mm2 8-2 AWG 8-4/0 AWG 1.5-95 mm2 8-4/0 AWG Voltage Rating 600 V 1000 V 600 V 600 V 1000 V 600 V Current Rating 115 A 150 A 115 A 230 A 232 A 230 A 27 lb-in 3.0 Nm 27 lb-in 87 lb-in 10.0 Nm 87 lb-in Std. Pk. Cat. No. Wire Range Torque Other Approvals Cat. No. Terminal Block Std. Pk. PTB35/50 PTB35/50SH 10 10 PTB70/95 PTB70/95SH 10 10 End Stop for ordering information refer to page 92 CA102 CA202 50 50 CA102 CA202 50 50 Bolt Size M6 – M8 – CA703/9 CA704/9 CA705/9 10 10 10 CA703/11 CA704/11 CA705/11 10 10 10 Marking Tags MT9 100 MT9 100 Marking Tag Holder MHPTB35* DIN Rail for ordering information refer to pages 90-91 Current Bars 2 pole 3 pole 4 pole MHPTB70* Marker Holder Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 53