Capacitive Switches

Standardmodels
2 mm switching distance
4 mm switching distance
M12
non-flush mounted plastic design
flush mounted metal design
DC
2 m cable, length = 61.5 mm
Plug M8, length = 61.8 mm
2 m cable, length = 61 mm
Plug M8, length = 61.3 mm
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
NPN
650.7303.001
650.7103.001
650.7303.004
650.7103.004
650.7319.001
650.7119.001
650.7319.004
650.7119.004
PNP
650.7903.001
650.7703.001
650.7903.004
650.7703.004
650.7919.001
650.7719.001
650.7919.004
650.7719.004
Standardmodels
5 mm switching distance
8 mm switching distance
M18
flush mounted metal design
DC
non-flush mounted plastic design
2 m cable, length = 81.7 mm
Plug S12, length = 81.7 mm
2 m cable, length = 81 mm
Plug M8 (DC)
Plug S12 (AC)
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
NPN
650.7305.001
650.7105.001
650.7305.004
650.7105.004
650.7321.723
650.7121.722
650.7321.002
650.7121.002
PNP
650.7905.001
650.7705.001
650.7905.004
650.7705.004
650.7921.724
650.7721.001
650.7921.002
650.7721.002
650.8521.001
650.8421.001
650.8521.004
650.8421.004
AC
Standardmodels
10 mm switching distance
length = 81 mm
20 mm switching distance
M30
flush mounted metal design
DC
non-flush mounted plastic design
2 m cable, length = 82 mm
Plug S12, length = 82 mm
2 m cable, length = 81 mm
Plug S12, length = 81 mm
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
NPN
650.7307.001
650.7107.001
650.7307.004
650.7107.004
650.7323.001
650.7123.001
650.7323.004
650.7123.004
PNP
650.7907.001
650.7707.001
650.7907.004
650.7707.004
650.7923.727
650.7723.001
650.7923.004
650.7723.004
650.8523.001
650.8423.001
650.8523.004
650.8423.004
AC
Standardmodels
15 mm switching distance
30 mm switching distance
M32
flush mounted metal design
2 m cable, length = 70 mm
non-flush mounted plastic design
Plug S12, length = 70 mm
2 m cable, length = 70 mm
Plug S12, length = 70 mm
N.O./N.C. prog. Complementary N.O./N.C. prog. Complementary N.O./N.C. prog. Complementary N.O./N.C. prog. Complementary
DC
NPN/
PNP
progr.
AC Relais
Timer
166
650.7013.011
650.7013.012
650.7013.015
650.7013.016
650.7013.001
650.8613.001
650.7013.002
650.7013.004
650.7013.005
Standardmodels
20 mm switching distance
15 mm switching distance
30 mm switching distance
Ø 20
Ø 34
flush mounted metal design
non-flush mounted plastic design
2 m cable
length = 81 mm
N.O.
N.C.
DC
Plug M8,
length = 81 mm
N.O.
N.C.
NPN
650.7310.002 650.7110.001 650.7310.004
PNP
650.7910.001 650.7710.001 650.7910.004 650.7710.004
AC
650.8510.001 650.8410.001
Standardmodels
8 mm switching distance
2 m cable,
length = 80.5 mm
N.O.
Plug S12,
length = 80.5 mm
N.O.
650.7915.005
650.7915.006
non flush mounted plstic design
2 m cable,
length = 81 mm
N.O.
N.F.
Plug S12,
length = 81 mm
N.O.
N.F.
650.7315.001 650.7115.001 650.7315.004 650.7115.004
650.7915.001 650.7715.154 650.7915.004 650.7715.004
650.8515.001 650.8415.001 650.8515.005 650.8415.004
10 mm switching distance
15 mm sw. dist.
30 mm sw. dist.
Sensors
E50
(50 x 25 x 10)
E68
(68 x 30 x 15)
flush mounted metal design
flush mounted plastic design
2 m cable
2 m cable
N.O.
N.O.
NPN
650.7390.001
650.7356.001
PNP
650.7990.001
650.7956.001
N44
(40 x 40 x120)
DC
flush mounted
plastic design
non-flush
plastic design
Terminal chamber
N.O./N.C. prog.
N.O./N.C. prog.
650.7054.001
650.7054.002
Technical data
Operating voltage
Operating current
Switch hysteresis
Repeatability
Switching frequency
Output
Reverse voltage protection
UB
IB
H
R
F
M12
10 - 36 V
D 200 mA
M18
10 - 60 V
D 200 mA
M18
Operating voltage
Operating current
Switch hysteresis
Repeatability
Switching frequency
Output
Reverse voltage protection
UB
IB
H
R
F
Rated switching distance
(flush mounted/non-flush mounted) sn
Adjustable switching distance
Function-/operating voltage indication
Operating temperature
Ingress protection
M12
M18
2/4 mm
5/8 mm
l/ā€“
l/l
DC-data
M32
Ø 20
Ø 34
E50
10 - 60 V
10 - 60 V
10 - 36 V
10 - 36 V
D 400 mA D 400 mA D 400 mA D 200 mA
20% of rated switching distance
D 10%
, 25 Hz
Sustained short curcuit and overload protection
yes
M30
10 - 60 V
D 400 mA
AC-data
M32
Ø 20
Ø 34
20 - 250 V
D 300 mA (M32 version with relay output 8 A)
20% rated switching distance
D 10%
, 15 Hz
(M32 version with adjustable off-delay 3-600 s)
yes
M30
M30
general technical data
M32
Ø 20
Ø 34
E50
10/20 mm 15/30 mm -/15 mm
20/30 mm 8/- mm
yes with potentiometer (apart from M12 plug version)
l/l
l/l
l/l
l/l
l/ā€“
-25°Cā€¦+70°C
IP 65/67 according to CEI 529/EN 60529
E68
N44
10 - 36 V 10 - 60 V
D 200 mA D 400 mA
N44
E68
10/- mm
l/ā€“
N44
15/30 mm
l/l
167