Standardmodels 2 mm switching distance 4 mm switching distance M12 non-flush mounted plastic design flush mounted metal design DC 2 m cable, length = 61.5 mm Plug M8, length = 61.8 mm 2 m cable, length = 61 mm Plug M8, length = 61.3 mm N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. NPN 650.7303.001 650.7103.001 650.7303.004 650.7103.004 650.7319.001 650.7119.001 650.7319.004 650.7119.004 PNP 650.7903.001 650.7703.001 650.7903.004 650.7703.004 650.7919.001 650.7719.001 650.7919.004 650.7719.004 Standardmodels 5 mm switching distance 8 mm switching distance M18 flush mounted metal design DC non-flush mounted plastic design 2 m cable, length = 81.7 mm Plug S12, length = 81.7 mm 2 m cable, length = 81 mm Plug M8 (DC) Plug S12 (AC) N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. NPN 650.7305.001 650.7105.001 650.7305.004 650.7105.004 650.7321.723 650.7121.722 650.7321.002 650.7121.002 PNP 650.7905.001 650.7705.001 650.7905.004 650.7705.004 650.7921.724 650.7721.001 650.7921.002 650.7721.002 650.8521.001 650.8421.001 650.8521.004 650.8421.004 AC Standardmodels 10 mm switching distance length = 81 mm 20 mm switching distance M30 flush mounted metal design DC non-flush mounted plastic design 2 m cable, length = 82 mm Plug S12, length = 82 mm 2 m cable, length = 81 mm Plug S12, length = 81 mm N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. NPN 650.7307.001 650.7107.001 650.7307.004 650.7107.004 650.7323.001 650.7123.001 650.7323.004 650.7123.004 PNP 650.7907.001 650.7707.001 650.7907.004 650.7707.004 650.7923.727 650.7723.001 650.7923.004 650.7723.004 650.8523.001 650.8423.001 650.8523.004 650.8423.004 AC Standardmodels 15 mm switching distance 30 mm switching distance M32 flush mounted metal design 2 m cable, length = 70 mm non-flush mounted plastic design Plug S12, length = 70 mm 2 m cable, length = 70 mm Plug S12, length = 70 mm N.O./N.C. prog. Complementary N.O./N.C. prog. Complementary N.O./N.C. prog. Complementary N.O./N.C. prog. Complementary DC NPN/ PNP progr. AC Relais Timer 166 650.7013.011 650.7013.012 650.7013.015 650.7013.016 650.7013.001 650.8613.001 650.7013.002 650.7013.004 650.7013.005 Standardmodels 20 mm switching distance 15 mm switching distance 30 mm switching distance Ø 20 Ø 34 flush mounted metal design non-flush mounted plastic design 2 m cable length = 81 mm N.O. N.C. DC Plug M8, length = 81 mm N.O. N.C. NPN 650.7310.002 650.7110.001 650.7310.004 PNP 650.7910.001 650.7710.001 650.7910.004 650.7710.004 AC 650.8510.001 650.8410.001 Standardmodels 8 mm switching distance 2 m cable, length = 80.5 mm N.O. Plug S12, length = 80.5 mm N.O. 650.7915.005 650.7915.006 non flush mounted plstic design 2 m cable, length = 81 mm N.O. N.F. Plug S12, length = 81 mm N.O. N.F. 650.7315.001 650.7115.001 650.7315.004 650.7115.004 650.7915.001 650.7715.154 650.7915.004 650.7715.004 650.8515.001 650.8415.001 650.8515.005 650.8415.004 10 mm switching distance 15 mm sw. dist. 30 mm sw. dist. Sensors E50 (50 x 25 x 10) E68 (68 x 30 x 15) flush mounted metal design flush mounted plastic design 2 m cable 2 m cable N.O. N.O. NPN 650.7390.001 650.7356.001 PNP 650.7990.001 650.7956.001 N44 (40 x 40 x120) DC flush mounted plastic design non-flush plastic design Terminal chamber N.O./N.C. prog. N.O./N.C. prog. 650.7054.001 650.7054.002 Technical data Operating voltage Operating current Switch hysteresis Repeatability Switching frequency Output Reverse voltage protection UB IB H R F M12 10 - 36 V D 200 mA M18 10 - 60 V D 200 mA M18 Operating voltage Operating current Switch hysteresis Repeatability Switching frequency Output Reverse voltage protection UB IB H R F Rated switching distance (flush mounted/non-flush mounted) sn Adjustable switching distance Function-/operating voltage indication Operating temperature Ingress protection M12 M18 2/4 mm 5/8 mm l/ā l/l DC-data M32 Ø 20 Ø 34 E50 10 - 60 V 10 - 60 V 10 - 36 V 10 - 36 V D 400 mA D 400 mA D 400 mA D 200 mA 20% of rated switching distance D 10% , 25 Hz Sustained short curcuit and overload protection yes M30 10 - 60 V D 400 mA AC-data M32 Ø 20 Ø 34 20 - 250 V D 300 mA (M32 version with relay output 8 A) 20% rated switching distance D 10% , 15 Hz (M32 version with adjustable off-delay 3-600 s) yes M30 M30 general technical data M32 Ø 20 Ø 34 E50 10/20 mm 15/30 mm -/15 mm 20/30 mm 8/- mm yes with potentiometer (apart from M12 plug version) l/l l/l l/l l/l l/ā -25°Cā¦+70°C IP 65/67 according to CEI 529/EN 60529 E68 N44 10 - 36 V 10 - 60 V D 200 mA D 400 mA N44 E68 10/- mm l/ā N44 15/30 mm l/l 167