Contactors (9 to 85A)

Contactors (9 to 85A)
9A
Frame size
12A
18A
22A
3-pole Contactors
For further technical information
see pages 8-9.
Types
includes AU-1
auxililary switch,
(1 N.O. / 1 N.C.)
AC coil
DC coil
Ratings / IEC60947-4
AC1
AC3
200/240V
380/440V
500/550V
690V
Ratings / UL508
continuous current
single phase
115V
230V
three phase
200V
230V
460V
575V
NEMA size
GMC-9
GMD-9
kW
2.5
4
4
4
hp
GMC-12
GMD-12
kW
A
25
3.5
13
5.5
12
7.5
12
7.5
9
hp
A
25
0.5
2
3
3
7.5
10
00
A
25
11
9
7
5
A
20
0.5
1
2
2
5
7.5
00
kW
4.5
7.5
7.5
7.5
hp
GMC-18
GMD-18
A
40
18
18
13
9
A
30
GMC-22
GMD-22
kW
A
40
22
22
22
18
A
32
5.5
11
15
15
hp
1
3
5
5
10
15
0
2
3
7
7.5
10
15
0
4-pole Contactors
For further technical information
visit altechcorp.com.
Types
AC coil
DC coil
AC1(A)
Available coil voltages
GMC-9/4
GMD-9/4
20
GMC-12/4
GMD-12/4
20
GMC-18/4
GMD-18/4
25
GMC-22/4
GMD-22/4
32
AC: 24, 42, 48, 110, 120, 208, 220, 240, 277, 380, 440, 480, 600V
DC: 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V
Ordering Example: GMC-9-AC120V (see also page 6)
Additional
Auxiliary Contacts
AU-2
AU-4
AU-1
2-pole
Front mount
4-pole
Front mount
2-pole
Side mount
Configuration
Part No.
Configuration
Part No.
Configuration
Part No.
2 N.O.
2 N.C.
1 N.O. / 1 N.C.
AU-2-20
AU-2-02
AU-2-11
4 N.O.
3 N.O. / 1 N.C.
2 N.O. / 2 N.C.
1 N.O. / 3 N.C.
4 N.C.
AU-4-40
AU-4-31
AU-4-22
AU-4-13
AU-4-04
1 N.O. / 1 N.C.
AU-1
Overload Relays
Setting
ranges (A)
Bimetallic style
Type GT
GT-22
Class 10A
Class 20
Differential
Non-differential (3-heater)
Non-differential (2-heater)
Differential
0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4
4-6
5-8
6-9
7 - 10
9 - 13
12 - 16
16 - 22
Base for
separate
mounting
AZ-22H
GTK-22
GTH-22/3
GTH-22
GTK-22/L
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
1
Contactors (9 to 85A)
32A
40A
50A
65A
75A
includes 2 AU-1
auxililary switches,
(2 N.O. / 2 N.C.)
includes 2 AU-1
auxililary switches,
(2 N.O. / 2 N.C.)
GMC-32
GMD-32
kW
GMC-40
GMD-40
kW
A
60
11
40
18.5
40
22
32
22
23
hp
A
50
3
5
10
10
25
25
1
A
50
32
32
28
20
A
45
7.5
15
18.5
18.5
hp
2
5
7.5
10
20
20
1
GMC-32/4
GMD-32/4
50
GMC-40/4
GMD-40/4
60
85A
GMC-50
GMD-50
kW
GMC-65
GMD-65
A
80
55
50
43
28
A
70
15
22
30
30
hp
kW
18.5
30
33
33
hp
3
7.5
10
15
30
30
2
A
100
65
65
60
35
A
80
5
10
15
20
40
40
2
GMC-50/4
GMD-50/4
80
GMC-75
GMD-75
kW
A
110
22
75
37
75
37
64
37
42
hp
A
90
5
15
20
25
50
50
2
GMC-65/4
GMD-65/4
100
GMC-85
GMD-85
kW
25
45
45
45
hp
A
135
85
85
75
45
A
100
7.5
15
25
30
50
50
3
GMC-75/4
GMD-75/4
110
GMC-85/4
GMD-85/4
135
AC: 24, 48, 110, 120, 208, 220, 240, 277, 380, 440, 480, 600V
DC: 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V
Ordering Example: GMC-32-AC120V (see also page 6)
AU-2
AU-4
AU-1
2-pole
Front mount
4-pole
Front mount
2-pole
Side mount
Configuration
Part No.
Configuration
Part No.
Configuration
Part No.
2 N.O.
2 N.C.
1 N.O. / 1 N.C.
AU-2-20
AU-2-02
AU-2-11
4 N.O.
3 N.O. / 1 N.C.
2 N.O. / 2 N.C.
1 N.O. / 3 N.C.
4 N.C.
AU-4-40
AU-4-31
AU-4-22
AU-4-13
AU-4-04
1 N.O. / 1 N.C.
AU-1
Setting ranges (A)
4-6
5-8
6-9
7 - 10
9 - 13
AZ-40H
GT-40
Setting
ranges (A)
Base for
separate
mounting
12 -18
16 - 22
18 - 26
24 - 36
28 - 40
7 - 10
9 - 13
12 -18
16 - 22
18 - 26
24 - 36
28 - 40
34 -50
45 - 65
54 - 75
63 - 85
Base for
separate
mounting
AZ-85H
GT-85
GTK-40
GTH-40/3
GTH-40
GTK-85
GTH-85/3
GTH-85
GTK-40/L
GTK-85/L
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com