700 0001 000 . 02.2011 . We reserve the right to make changes Switch technology – Economy meets safety Sensor technology – Compact intelligence Enclosure technology – Function and design www.bernstein.eu Contact International Headquarters BERNSTEIN AG Tieloser Weg 6 D-32457 Porta Westfalica Tel. + 49 571 793-0 Fax + 49 571 793-555 [email protected] www.bernstein.eu Denmark BERNSTEIN A/S Tel. + 45 7020 0522 Fax + 45 7020 0177 [email protected] France BERNSTEIN S.A.R.L. Tel. +33 1 64 66 32 50 Fax +33 1 64 66 10 02 [email protected] United Kingdom BERNSTEIN Ltd. Tel. +44 1922 744999 Fax +44 1922 457555 [email protected] Netherlands BERNSTEIN BV Tel. +31 314 366088 Fax +31 314 361256 [email protected] Austria BERNSTEIN GmbH Tel. +43 2256 62070-0 Fax +43 2256 62618 [email protected] Italy BERNSTEIN S.r.l. Tel. +39 035 4549037 Fax +39 035 4549647 [email protected] Switzerland BERNSTEIN (Schweiz) AG Tel. +41 44 775 71-71 Fax +41 44 775 71-72 [email protected] China BERNSTEIN Safe Solutions (Taicang) Co., Ltd. Tel. +86 512 81608180 Fax +86 512 81608181 [email protected] BERNSTEIN AS-i Safety at Work Program What is AS-i? CSMS 2 MAK’s SHS3 SLK ENK (VTU) AS-Interface is the innovative solution for sensor and actuator wiring, regardless of whether standard or safety-relevant applications are concerned. Only one yellow, two-wire ribbon cable with reverse polarity protected profiling is laid to transmit the energy and data to up to 248 inputs and 248 outputs. Modern systems must nowadays be inexpensive, flexible, service-friendly and able to detect faults. All these properties are incorporated in the AS-Interface right from the start. Suitable slaves can be plugged in any position according to the “plug & play” principle. The contact between the device connection and the cable is made by the so-called piercing technology. The simplicity and safety in installation, operation and maintenance as well as the long-term potential for reducing costs speak for themselves. Here, the contacts pierce the insulation through to the wire. The given geometry of the BUS adapter and the cable cross-section prevent installation errors. SK SKT Ti2 I88 ENK The AS-Interface cannot and is not intended to replace the existing and proven bus systems. AS-Interface is a standalone solution or an extension of the existing system. Linking to ProfiSafe, Profinet, Profibus, Ethernet, CAN, Ethercat, DeviceNet, Interbus and Powerlink is possible without any problems by gateways. AS-Interface and every sensor/actuator connected to it then behave as slaves of the master bus system. The high integration capability into other networks simplifies the modular set-up of automation networks. SRM Emergency stopping Owing to the many providers of components of this non-proprietary system, almost every type of sensor and actuator is available with AS-i interface. This enables AS-i systems to be established in all conceivable branches, from automation technology and process technology, ship building and commercial vehicles to building technology. AS-Interface is standardised in accordance with EN 50295 and IEC 62026-2. In addition to the advantages already mentioned, safety systems up to PL e/SIL 3 can also be implemented with AS-i as described on the following pages. 3 Safety at Work, the Safety Bus Safety functions up to PL e according to EN 13849 and SIL 3 according to 62061 can be implemented with AS-Interface Safety at Work. The safety-relevant data is transmitted on a two-wire ribbon cable and therefore minimises the wiring effort. This along with the simplicity in planning, installation and maintenance is one of the main reasons why AS-i Safety at Work is the most frequently used safety bus. For a Safety at Work system you only require the safety-oriented slaves, a master and a safety monitor. The latter dynamically monitors the safe users and switches off the safety path in the event of an error or at the prompting of a safety function. With ASIMON the safety application is created quickly and easily on the PC by drag & drop The safety application is created with the Windows program “ASIMON” and then loaded into the safety monitor. Changes and extensions to the safety application can be made by a software adaptation combined with the piercing connection technology in a few seconds, even in a safety application program. There are two possible system structures for setting up an AS-i Safety at Work system. (see page 6/7). 4 5 System Structure 1: Safety Gateway in Stainless Steel System Structure 2: Safety Basis Monitor For large and medium safety applications For the smallest safety applications The standard master safety monitor combinations with the AS-i power supply unit are used for large and medium safety applications. The Safety Basis Monitor is used for the smallest safety applications with only a few safety-relevant users. This device not only unites master and monitor in one housing with a width of just 22.5 mm but also needs only one standard 24 Volt power supply unit for applications with a current consumption of less than 0.5 Ampere. It also has safe outputs and safe and standard inputs on board. Up to 62 safety-relevant users (31 per circuit, two circuits contained in the safety monitor) such as emergency stop, door and hood monitors, holds, light grids, two-hand operation and, of course, also safe outputs can be integrated into such systems and linked with ASIMON. Because of the consistent design on compact machines, it is also of economic interest to implement the smallest safety applications with AS-i Safety at Work with this safety monitor. An AS-Interface Safety at Work system also reduces the number of I/Os on a controller in addition to reducing the wiring effort and completes a large part of the documentation automatically and incidentally with ASIMON. Status information or, in the case of a Profisafe interface, the safety-relevant information of the safety slaves can be transmitted directly to a suitable controller with the gateway of the master. General features l2 safety relay outputs 2 safety non-expendable semiconductors AS-i Safety only previously paid off when used in systems with a greater safety requirement. l4 EDM input lField bus interface l1/2 AS-I circuits lDiagnostic and adjustments facilities via display lRobust stainless steel enclosure l16 enable circuits l256 devices in the ASIMON program General features Comparison of Safety Tech nology System Costs Conventional wiring was often the less expensive solution in the past in small function blocks with one emergency stop and one door hold for example. 6 l4 safety inputs or optionally 8 standard inputs + 8 standard outputs lSignal outputs Costs Safety Big 20 safety signals Average 8 safety signals Costs Safety Small 2 safety signals Equipment costs Conventionally AS-i Safety 50 % 57 % 62 % 85 % Equipment costs Conventionally AS-i Safety 74 % 77 % Installation of the machine Conventionally AS-i Safety 25 % 7% 19 % 5% Installation of the machine Conventionally AS-i Safety 13 % 9% lIP20 plastic enclosure Conventionally AS-i Safety 13 % 3% l8 enable circuits Conventionally AS-i Safety 100 % 89 % l128 devices in the ASIMON program Installation of the control cabinet Conventionally AS-i Safety 25 % 4% 19 % 2% Installation of the control cabinet Result Conventionally AS-i Safety 100 % 62 % 100 % 98 % Result lChip card for easy unit exchange lAS-i Power24 capacity l2 safety non-expendable semiconductors l1 AS-i circuit lDiagnostic facilities via LEDs lChip card for easy unit exchange Conclusion: AS-i Safety already pays off in small machines! lAS-i Power24 capacity 7 System Benefits General Information about BERNSTEIN AS-i Products The use of the AS-i Bus considerably reduces the planning and documentation effort because only minimum circuit digrams have to be drawn. In addition to the drastic reduction in the installation time in comparison with standard wiring, numerous components such as safety relays, terminal boxes and thus their processing as well as integrated screw connections and terminals and PLC I/Os plus an enormous quantity of cables are saved. This leads in turn to a reduction in the amount of space required in the control cabinet, cable ducts and machines. lThe safety switches Ti2, I88 Bi2 and ENK can be fitted with all actuators for the respective product series on request General technical data lThe mechanical switches are always equipped with 2 positive break contacts p as a slow action element lVoltage range: 26,6 … 31,6 V lJump switch systems are available on request lMetal switches of the ENM2, GC and SN2 series and D switches can be equipped with AS-Interface on request The systems can be commissioned fast thanks to the simple and reliable connection technology. If changes have to be made sooner or later, this is no problem as long as the maximum number of slaves has not been reached. lPlug assignment - Pin 1 - Pin 2 - Pin 3 - Pin 4 Without Aux Including Aux AS-i +AS-i + FreiAux – AS-i –AS-i – FreiAux + lAS-i address: Preset address 0 Just connect the necessary slave to the cable and transfer it to the configuration by laptop or directly on the master. Finished. This also enables prevention of unwanted machine failures. If this does happen, the excellent diagnostic properties show the error directly on the monitor. Since it is only a two-wire cable, the AS-i system can be adapted optimally to a modular machine. This can be done by connecting two wires to a complete system or by separate sub-systems which are networked by a master bus system (e. g. Profibus). These properties of the AS-i ultimately lead to substantial advantages for the machine user. The commissioning and maintenance costs as well as machine downtimes are considerably reduced. And if the system needs to be extended or modified after a time, the existing system can be disassembled quickly. System data can also be read out of the slaves or changed by connecting with a master bus system. This enables remote maintenance to the smallest element of an automation safety system. lAS interface specification: Profile S-0.B - IO-Code: 0 x 0 - ID-Code: 0 x B - ID-Code 1: 0 x F - ID-Code 2: 0 x E Direct Connection Technology The direct connection allows the switch to be connected directly to the two-pole AS-Interface cable. This saves the coupling module and the M12 connection cable. The direct connection technology is recognisable by a “D” at the end of the article designation. Switches of the type 1 and 2, such as Ti2, I88, SK, SKT etc. are available with the direct connection technology. Safety figures PL according to EN 13498/SIL according to 62061 up to Cat B10d Ti2 c* 1 6 Mio I88, Bi2, ENK c* 1 20 Mio SKT, SK, ENK, VTU c* 1 2 Mio SLK c* 1 2 Mio SHS3 c* 1 2 Mio SRM c* 1 0,2 Mio MAK 42, MAK 52 e 4 20 Mio Emergency stopping e 4 0,1 Mio CSMS e/3 4 Safety Basis Monitor e/3 4 Safety monitor e/3 4 *By fault exclusion according to EN 13849-1 and EN 13849-2, PL d can be achieved. By using 2 safety switches and mutual monitoring, Cat 4, PL e can be achieved. 8 9 Application Example Application Example E.C.H. Will, Hamburg Walterwerke, Kiel E.C.H. Will is a leading provider of machines for paper producing and processing companies and small format cutters, format cutting systems and processing lines for manufacturing school excercise books. Use of CSMS to monitor safety doors of a format cutting machine. The machines run at a very high process speed. The doors need to be opened frequently for maintenance or to clear paper jams. A non-contact system is the ideal solution because wear is not a problem. Before our CSMS systems were used, various products were installed, none of which supplied reliable switching signals in the long term. 10 “There were frequent error messages on the bus,” the site technical manager says. “Standstills are downtimes and are to be avoided at all cost.” Walterwerke in Kiel manufactures waffle baking machines. Walterwerke used the AS-i ENK because of its robust housing among other things. The compact design which has the system disappear invisibly behind the door profiles is just one of the advantages which convinced the customer, in addition to the reliable application for all safety doors. This switch is used with a special axis lever actuator for safety prompting of a flap in the hot temperature ranges. Our switch has been installed in the plants as a conventional system. In the course of changing over to the new Machinery Directive, the AS-i Bus has been introduced and the Bernstein switch inserted again in the appropriate configuration. They are very pleased with the technical solution. The baking trays which enter the oven at high speed have to be monitored for correct position. There is also a flap above the entrance to protect the operator from reaching into the high temperature oven. The AS-i Safety at Work switch stops the system if the flap is opened. 11 AS-i Slaves AS-i Slaves Contactless safety sensors Safety Hinge Switch Transponder technology CSMS Contactless Safety Monitoring Switch 6073200060 AS-i CSMS-M-ST 6073200061 AS-i CSMS-S 6073200062 AS-i CSMS-SET Spacer (CSMS Accessories) 6073900070 CSMS Spacer 5 mm lSafety slave lDynamically coded signal transmission lTamperproof operation lSwitching status and function reserve indicator lAS-i status display lCan be conspicuously mounted lSuitable for harsh environments lM12 connector lNon-contact operation gives superior life expectancy lSwitching distance 15 mm lSwitching distance 15 mm lFor installing the CSMS on metal bases 6073200071 AS-i CSMS-R-M-ST 6073200072 AS-i CSMS-R-S 6073200011 AS-i SHS3 SA R 6073200013 AS-i SHS3 SR R lSafety slave lCoded actuator lSwitching status indicator lAS-i status display lSuitable for concealed installation lSuitable for harsh environments lNon-contact operation gives superior life expectancy lM12 connector SLK MAK 52 6073200068 AS-i MAK 52 6402052307 TK-52-CD/2 MAK 42 6073200067 AS-i MAK 42 6402042053 TK-42-CD/2 lSafety slave lCoded actuator (magnetic) lSwitching status indicator lAS-i status display lSuitable for concealed installation lSuitable for harsh environments lNon-contact operation gives superior life expectancy SRM AS-i SRM-LU-175 AS-i SRM-LU-300 AS-i SRM-QF-175 AS-i SRM-QF-300 lSafety slave lRope-pull switch in metal housing lAS-i status display lTensioned length up to 75 meters (version 300) (37,5 meters version 175) lQuick-Fix quick action clamping head QF available Safety switch with separate actuator SK 6073205050 AS-i SK F30 M 6073205028 AS-i SK M 6073205039 AS-i SK M D SKT 6073200006 AS-i SKT 6073200029 AS-i SKT D ENK VTU 6073504025 AS-i ENK VTU 6073504038 AS-i ENK VTU D 12 lSafety slave lInterlock switch for safety doors and protective hoods lSpring force (closed-circuit current) type F and magnetic force (working current) type M lStatus display for the actuating and interlock position lThe status LEDs could alternatively be switched by the control system lAS-i status display lFeed-in of the interlock by external power supply system Safety rope-pull switch 6073200009 6073200010 6073200007 6073200008 lSafety slave lCoded actuator (magnetic) lSwitching status indicator lAS-i status display lSuitable for concealed installation lSuitable for harsh environments lNon-contact operation gives superior life expectancy lSafety slave lHinge Switch lAS-i status display lSwitching point freely adjustable by user over a range of 270° lFine adjustment +/- 1,5° lFreely and repeatedly adjustable switching point Safety interlock (without actuator) 6073200058 AS-i SLK-F-R1-A0-0 6073200057 AS-i SLK-M-R0-A0-0 Magnetic technology (at the beginning of 2011) CSMS Reed SHS3 lSafety slave lSafety switch with separate actuator lAS-i status display lPlastic housing lVariable actuator with two actuator openings lSafety slave lSafety switch with separate actuator lSlim and short switch design lAS-i status display lPlastic housing lRotary head in 90° steps l2 actuating entries lSafety slave lSafety switch with separate actuator lEspecially robust switch design lAS-i status display lPlastic housing lRotary head in 90° steps 13 AS-i Slaves AS-i Slaves Position safety switches Emergency stop switches and control elements (in the portfolio from the beginning of 2011) Ti2 6073403020 6073403035 6073402019 6073402034 6073401018 6073401033 AS-i Ti2 Hw AS-i Ti2 Hw D AS-i Ti2 Riw AS-i Ti2 Riw D AS-i Ti2 w AS-i Ti2 w D lSafety slave lSmallest switch with integrated AS Safety at Work interface lAS-i status display lActuator of the standard program available lPlastic housing lFixing measures according to DIN EN 50047 Emergency stop buttons, illuminated pushbuttons and indicator lamps are available in the new, elegant housing. The housing is specially designed for 40 mm profile rails and features a special assembly concept. It can also be used outside the profile rails of course. Start, enable and request buttons can also be connected decentrally to the AS-i system with the control elements. The status of the process can be displayed by the illuminated pushbuttons. With these AS-i solutions, the necessary functions can be placed exactly where they are needed. Emergency stop 6073100074 AS-i EMERGENCY STOPPING BUTTON I88 6073303017 6073303032 6073302016 6073302031 6073301015 6073301030 AS-i I88 Hw AS-i I88 Hw D AS-i I88 RiwK AS-i I88 RiwK D AS-i I88 w AS-i I88 w D lSafety slave lSwitch design according to industry standard DIN EN 50047 lAS-i status display lActuator of the standard program available lPlastic housing Press button / Signal lamp Control element Bi2 6073201052 AS-i Bi2 w 6073201051 AS-i Bi2 w D lEmergency stopping button with integrated safety AS-i slave lWith 30 mm emergency stopping button lReset via right hand rotation l2 coloured status display of emergency stopping button lM12 connector lSafety slave lSide-positionned M12 connection lAS-i status display lActuator of the standard program available lPlastic housing 6073100075 AS-i CONTROL ELEMENT lIlluminated push button with AS-i interface slave l2 x 22 mm illuminated push button lM12 connector l2 coloured status display per button (programmable via AS-i) E/A module ENK 6073501023 6073501036 6073502024 6073502037 6073504025 6073504038 14 AS-i ENK iw AS-i ENK iw D AS-i ENK Riw AS-i ENK Riw D AS-i ENK VTU AS-i ENK VTU D lSafety slave lAS-i status display lActuator of the standard program available lEspecially robust switch design lFixing measures according to DIN EN 50041 Turning-on box 6073100027 AS-i TURNING-ON-BOX 4 IN lAS-i Slave l4 digital input PNP lStatus display of inputs via LED lAS-i status display lVia ASI cable connectable lConnectors M12 15 Master / Safety Monitor / Power Supply Unit Safety basis monitor (in the portfolio from the beginning of 2011) Software package This safety monitor is intended for the smallest AS-i safety systems. With this safety monitor, the smallest safety applications can be implemented with AS-i, something which was previously unthinkable for cost reasons. The programming of the safety application is done quickly and simply with the Windows program ASIMON as is usual in AS-i Safety at Work. In this package is included: lASIMON for programming the safety monitor lAS-i Control Tool for addressing, diagnostic and testing of the AS-i bus syste lSerial cable for connecting the master and monitor at the computer 6073800021 AS-i PROG SW + KBL Basis monitor 6073100073 AS-i BASIS MONITOR lIntegrated master lA special power supply unit AS-i is not necessary (up to 0,5 ampere) lIntegrated safety outputs lIntegrated safety inputs lIntegrated standard inputs lOnly 22,5 mm installation width Hand-held programming device Safety monitor lAddressing / Programming up to 62 slaves max. lDisplay of all existing slaves in the bus system lReading and writing of slave datas lLCD Display lRechargeable battery integrated lCharging device is included in delivery 6073100005 AS-i HND PRG 6073100004 AS-i SMON B+W lSafety monitor for 2 AS-i circuits l16 enable circuits l2 x two channel relay enable circuits in the device l2x EDM and 2 x start input in the device lDisplay for addresses and exact fault location lConfiguration storable on chip card 85 96 120 Master 6073100001 AS-i MST PROFIBUS lAS interface master with profibus slave l2 AS-i master integrated lDouble address recognition lEarth fault monitor integrated lDisplay for ASI slaves addresses and exact fault location lLEDs for status display lSimple use with only 4 integrated buttons lGateways for Profisafe, Profinet, Ethernet, Powerlink, EtherCat, -CanOpen, DeviceNet, Modbus, Master for all Allen-Bradley ControlLogix available Accessories see side 18/19 55 76 7 75 120 1 External power supply system 6073100003 AS-i NT 4A B+W l90 V AC up to 265 V AC multi voltage power supply unit l4 A primarily clocked power supply unit lLED operating mode display lAS-i data decoupling lSELV 126 Power supply 70 2 3 4 129 5 16 17 Accessories Connecting module 3 lFor connecting AS-i devices on AS-i profile cable with M12 connecting line lCodification of the M12 connector turnable over a range of 90° Connecting module 4 6073900047 AS-i CABLE BRIDGE lBranch for AS-i profile cable lThe connection under the cables is effected when opening the cover Connecting cable 5 lFor connecting AS-i devices on AS-i profile cable with an integrated, 2 meters long ready-made connecting line and M12 straight connecting box lConnecting cable for the connection of the ASi Slave and the connecting module lDouble-sided ready-made straight M12 connecting units (connector/socket) 31 43,9 L 48,5 L Ø14,5 6073900048 AS-i CONNECTING C.M12 1M G/G L Ø14,5 M12 x1 6073900043 AS-i KOP. M. 0.3 RK U. M12 G 48,5 Ø14,5 M12 x1 31 Ø14,5 6073900042 AS-i CONNECTING MODULE M12 SCREW Cable bridge 2 Connecting module Connecting cable 6073900049 AS-i CONNECTING C.M12 1M G/W lConnecting cable for the connection of the ASi Slave and the connecting module lDouble-sided ready-made M12 connecting units, straight connector/angled socket 38,5 31,25 L Ø12,6 lConnecting module for connecting AS-i devices on AS-i profile cable with an integrated, 2 meters long ready-made connecting line and M12 angled connecting box 27,5 20 6073900044 AS-i KOP. M. 0.3 RK U. M12 W Ø14,5 Ø14,5 M12 x1 31 M12 x1 Ø14,5 Yellow cable EPDM Connecting module + double 1 lFor connecting AS-i devices on AS-i profile cable with an integrated, 2 meters long ready-made connecting line and M12 straight connecting box 6073900040 AS-i KABEL EPDM YELLOW lYellow AS-i profile cable EPDM 2 mm 6073900045 AS-i KOP.2F M.0.5RK U. M12 G 4 mm 6,5 mm 10 mm Connecting module + double Black cable EPDM lFor connecting AS-i devices on AS-i profile cable with an integrated, 2 meters long ready-made connecting line and M12 angled connecting box 6073900041 AS-i KABEL EPDM BLACK lBlack AS-i profile cable EPDM 2 mm 6073900046 AS-i KOP.2F M.0.5RK U. M12 W 4 mm 6,5 mm 10 mm 18 19