KADN/KAMN30 SERIES AC - DC POWER MODULE 25 ~ 30W SINGLE & DUAL OUTPUT FEATURES ‧AC/DC POWER MODULE ‧UNIVERSAL INPUT 85 ~ 265 VAC ‧HIGH EFFICIENCY UP TO 86% ‧SHORT CIRCUIT PROTECTION ‧INTERNAL INPUT FILTER ‧3 YEARS WARRANTY ‧MEDICAL SAFETY APPROVED ‧LOW LEAKAGE CURRENT ‧TWO MOPP INSULATIONS KAMN30 series KADN30 series OPEN FRAME R R H H UL 60950-1 EN 60601-1 UL 60601-1 a EN 60950-1 MODEL LIST INPUT VOLTAGE MODEL NO. OUTPUT WATTAGE OUTPUT VOLTAGE OUTPUT CURRENT EFF. (min.) EFF. CAPACITOR LOAD (typ.) (max.) Single Output Models 25 WATTS + 3.3 VDC 7500 mA 75% 77% 7000μF 85 ~ 265 VAC 30 WATTS + 5 VDC 6000 mA 79% 81% 7000μF 85 ~ 265 VAC 30 WATTS + 12 VDC 2500 mA 83% 85% 7000μF KADN/KAMN3015 85 ~ 265 VAC 30 WATTS + 15 VDC 2000 mA 84% 86% 7000μF KADN/KAMN3024 85 ~ 265 VAC 30 WATTS + 24 VDC 1250 mA 84% 86% 3500μF ± 1250 mA 82% 84% ± 7000μF 85% KADN/KAMN3003 85 ~ 265 VAC KADN/KAMN3005 KADN/KAMN3012 Dual Output Models KADN/KAMN3012D 85 ~ 265 VAC KADN/KAMN3015D 85 ~ 265 VAC 30 WATTS ± 15 VDC ± 1000 mA 83% KADN/KAMN30512D 85 ~ 265 VAC 30 WATTS +5 / + 12 VDC +3A / + 1.25A 80% 82% ± 7000μF 7000μF KADN/KAMN30524D 85 ~ 265 VAC 30 WATTS +5 / + 24 VDC +3A / + 0.65A 80% 82% 7000μF 30 WATTS ± 12 VDC SPECIFICATION o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed GENERAL Characteristics Conditions min. Switching frequency Vi nom, Io nom Isolation voltage Input - Output Isolation resistance Input - Output, @ 500VDC 100 Operating at Vi nom, Io nom -40 Ambient temperature 1) typ. max. 65 unit KHz VAC/VDC 4,236 / 6,000 MΩ + 71 o + 85 o C Case temperature Operating at Vi nom, Io nom Derating Vi nom, +61 to + 71 oC Storage temperature Non operational -40 +100 Relative humidity Vi nom, Io nom 20 95 % RH Temperature coefficient Vi nom, Io min ± 0.03 % / oC KAMN30 C % / oC 2.5 o C NOTE1 : Pls refer to DERATING CURVE. www.chinfa.com 2015.02.02 [email protected] P1 KADN/KAMN30 SERIES AC - DC POWER MODULE SPECIFICATION o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed GENERAL Characteristics MTBF Altitude during operation Conditions o Bellcore issue 6 @40 C, GB typ. max. unit 3.3V, 5V, 512D & 524D 703,000 Hours 12V, 12D & 15D 722,000 Hours 15V & 24V 740,000 IEC 60068-2-13 Hours m 4,850 Dimension Cooling min. KAMN30 L89 x W63.5 x H25 mm KADN30 L85.3 x W60.3 x H24.2 mm typ. max. unit VAC Free air convection INPUT SPECIFICATIONS Characteristics Rated input voltage Input voltage range min. Conditions Io nom Ta min ... Ta max, Io nom Input current Vi : 115 / 230 VAC, Io nom Rated input current Vi : 100 ~ 240 VAC, Io nom Line frequency (Note 2) Vi nom, Io nom Inrush current Leakage current (Note 2) Vi : 115 / 230 VAC, Io nom 100 240 AC in 85 265 VAC DC in 120 375 VDC 0.56 / 0.34 A 0.8 - 0.4 A 63 20/40 Hz 47 Normal condition Single fault condition A μA μA 100 300 NOTE 2 : The unit can be worked at 440 Hz of line frequency but the leakage current would be 600μA max. , and output load should be derated under 90% OUTPUT SPECIFICATIONS Characteristics Output voltage accuracy Minimum load Line regulation Load regulation Conditions Vi nom, Io nom Vi nom typ. max. unit single output models ±1 % dual output models ±2 % 524D model single output models ±4 % 0 dual output models (each output) 20 Io nom, Vi min ...Vi max Vi nom, Io min ...Io nom min. % % ±1 % single output models ±1 % dual output models ±2 % ±6 % ms Cross regulation (Dual model) Asymmetrical load 20% / 100% FL Hold up time Vi : 115 / 230 VAC, Io nom Turn on time Vi nom, Io nom 1,000 ms Rise time Vi nom, Io nom 150 ms Fall time Transient recovery time Vi nom, Io nom 150 ms Ripple & noise Vi nom, Io nom, BW = 20MHz External trim ADJ. Range (Note 3) (for single output only) Io = 5% ...100% Efficiency Vi nom, Io nom, Po / Pi 15 / 75 Vi nom, 1~0.5 Io nom -10 1 ms 50 mV +10 % Up to 86%, See model list and typ efficiency curve NOTE 3 : Pls refer to Fig 1 & Table 1 for connection and resistance recommended. CONTROL AND PROTECTION Characteristics Conditions min. Input fuse Internal surge voltage protection www.chinfa.com 2015.02.02 max. unit T2A / 250VAC internal Varistor IEC 61000-4-5 Hiccup mode Output short circuit Rated over load protection typ. Vi nom (see typ current limited curve) 120 160 % [email protected] P2 KADN/KAMN30 SERIES AC - DC POWER MODULE SPECIFICATION o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed APPROVALS AND STANDARDS UL / cUL UL 60950-1, UL 60601-1 Recognized TUV EN 60950-1, EN 60601-1 CE EN 60601-1-2, EN 55011, EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5 Vibration resistance EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, EN 61204-3 meet IEC 60068-2-6 (10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis) Shock resistance meet IEC 60068-2-27 (15G, 11ms, 3 axes, 6 Faces, 3 times for each Face) PHYSICAL CHARACTERISTICS Case size KAMN30 : 89 x 63.5 x 25mm ( 3.5 x 2.5 x 0.98 inches) Case material Plastic case / PCB base Weight KAMN30 : 250g Potting material KAMN30 : Epoxy KADN30 : 85.3 x 60.3 x 24.2mm ( 3.36 x 2.37 x 0.95 inches) KADN30 :130g MECHANISM & PIN CONFIGURATION mm [inch] 60.30 [2.37] 63.50 [2.50] 2.20 [0.09] 27.90 [1.10] 27.90 [1.10] 27.90 [1.10] 27.90 [1.10] 2.20 [0.09] 3.90 [0.15] 3.85 [0.15] 5 4 5 3 4 3 KADN30 KAMN30 2-TP 3 x 8 81.20 [3.20] 81.20 [3.20] 85.30 [3.36] 89.00 [3.50] 54.50 [2.15] 54.50 [2.15] 43.30 [1.70] 45.20 [1.80] 1 1 2 2 55.80 [2.20] 55.80 [2.20] BOTTOM VIEW BOTTOM VIEW 24.20 [0.95] 25.00 [0.98] GENERAL TOLERANCE 5.50 [2.20] DIA 1.00 [0.04] 0.00[0.00] - 30.00[1.18] ±0.30[0.01] 30.00[1.18] - 120.00[4.72] ±0.50[0.02] DIA 1.00 [0.04] 5.50 [0.22] PIN ASSIGNMENT GENERAL PIN NO. 1 3 5 AC IN AC IN Vo + 4 Vo com 512D AC IN AC IN +5V com +12V 524D AC IN AC IN +5V com +24V SINGLE DUAL 12D, 15D AC IN 2 AC IN Vo + Trim Vo - CIRCUIT SCHEMATIC ‧Block diagram for KAM(D)N30 series with single output AC IN Fuse Vo + Rectifier Line Filter AC IN Inrush Current Switching Limiter and Device Rectifier Vo - Control Circuit www.chinfa.com Fuse Opto Isolation Reference & Error Amp. Trim Vo + Rectifier Line Filter AC IN 2015.02.02 ‧Block diagram for KAM(D)N30 series with dual output Inrush Current Switching Limiter and Device Rectifier com Rectifier AC IN Control Circuit Opto Isolation Vo - Reference & Error Amp. [email protected] P3 KADN/KAMN30 SERIES AC - DC POWER MODULE TYP. CURRENT LIMITED CURVE CIRCUIT SCHEMATIC v Fuse AC IN Line Filter Inrush Current Switching Limiter and Device Rectifier Rectifier +5V Rectifier +12V or +24V Output Voltage [ % ] ‧Block diagram for KAM(D)N30512D & KAM(D)N30524D com AC IN Control Circuit Reference & Error Amp. Opto Isolation Hiccup mode 100 50 t Time DERATING CURVE 100 75 Power out [ % ] Power out [ % ] o Ta = -40 C Safe Operating Area 0 -40 61 Temperature [ oC ] 100 75 Safe Operating Area 85 71 TYP. EFFICIENCY CURVE 90 115 230 Input Voltage [ VAC ] 265 Fig. 1 Trim connection (For single output only) KAM(D)N3024 EFFICIENCY [ % ] 85 80 5 75 4 70 230 Vac 115 Vac 65 3 Trim 5 Vo - Rext 1 4 Vo + 3 Trim Rext 2 Vo Vo + 60 10 25 50 Power out [ % ] 75 100 Table 1 Typical resistor values for various output voltage adjustment settings and max continuous power Type Rext 1 Vo nom -5% Rext 2 Vo nom -10% Vo nom +5% Vo nom +10% Max continuous power KAM(D)N3003 20KΩ 5.1KΩ 3KΩ 1KΩ 25 W KAM(D)N3005 5.1KΩ 1KΩ 6.8KΩ 2KΩ 30 W KAM(D)N3012 39KΩ 20KΩ 10KΩ 0Ω 30 W KAM(D)N3015 180KΩ 56KΩ 30KΩ 5.1KΩ 30 W KAM(D)N3024 150KΩ 51KΩ 8.2KΩ 0Ω 30 W www.chinfa.com 2015.02.02 [email protected] P4