KADN/KAMN30 SERIES

KADN/KAMN30 SERIES
AC - DC POWER MODULE
25 ~ 30W SINGLE & DUAL OUTPUT
FEATURES
‧AC/DC POWER MODULE
‧UNIVERSAL INPUT 85 ~ 265 VAC
‧HIGH EFFICIENCY UP TO 86%
‧SHORT CIRCUIT PROTECTION
‧INTERNAL INPUT FILTER
‧3 YEARS WARRANTY
‧MEDICAL SAFETY APPROVED
‧LOW LEAKAGE CURRENT
‧TWO MOPP INSULATIONS
KAMN30 series
KADN30 series
OPEN FRAME
R
R
H H
UL 60950-1
EN 60601-1
UL 60601-1
a
EN 60950-1
MODEL LIST
INPUT
VOLTAGE
MODEL NO.
OUTPUT
WATTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFF.
(min.)
EFF. CAPACITOR
LOAD
(typ.) (max.)
Single Output Models
25 WATTS
+ 3.3 VDC
7500 mA
75%
77%
7000μF
85 ~ 265 VAC
30 WATTS
+
5 VDC
6000 mA
79%
81%
7000μF
85 ~ 265 VAC
30 WATTS
+ 12 VDC
2500 mA
83%
85%
7000μF
KADN/KAMN3015
85 ~ 265 VAC
30 WATTS
+ 15 VDC
2000 mA
84%
86%
7000μF
KADN/KAMN3024
85 ~ 265 VAC
30 WATTS
+ 24 VDC
1250 mA
84%
86%
3500μF
± 1250 mA
82%
84%
± 7000μF
85%
KADN/KAMN3003
85 ~ 265 VAC
KADN/KAMN3005
KADN/KAMN3012
Dual Output Models
KADN/KAMN3012D
85 ~ 265 VAC
KADN/KAMN3015D
85 ~ 265 VAC
30 WATTS
± 15 VDC
± 1000 mA
83%
KADN/KAMN30512D
85 ~ 265 VAC
30 WATTS
+5 / + 12 VDC
+3A / + 1.25A
80%
82%
± 7000μF
7000μF
KADN/KAMN30524D
85 ~ 265 VAC
30 WATTS
+5 / + 24 VDC
+3A / + 0.65A
80%
82%
7000μF
30 WATTS
± 12 VDC
SPECIFICATION
o
All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed
GENERAL
Characteristics
Conditions
min.
Switching frequency
Vi nom, Io nom
Isolation voltage
Input - Output
Isolation resistance
Input - Output, @ 500VDC
100
Operating at Vi nom, Io nom
-40
Ambient temperature
1)
typ.
max.
65
unit
KHz
VAC/VDC
4,236 / 6,000
MΩ
+ 71
o
+ 85
o
C
Case temperature
Operating at Vi nom, Io nom
Derating
Vi nom, +61 to + 71 oC
Storage temperature
Non operational
-40
+100
Relative humidity
Vi nom, Io nom
20
95
% RH
Temperature coefficient
Vi nom, Io min
± 0.03
% / oC
KAMN30
C
% / oC
2.5
o
C
NOTE1 : Pls refer to DERATING CURVE.
www.chinfa.com
2015.02.02
[email protected]
P1
KADN/KAMN30 SERIES
AC - DC POWER MODULE
SPECIFICATION
o
All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed
GENERAL
Characteristics
MTBF
Altitude during operation
Conditions
o
Bellcore issue 6 @40 C, GB
typ.
max.
unit
3.3V, 5V, 512D &
524D
703,000
Hours
12V, 12D & 15D
722,000
Hours
15V & 24V
740,000
IEC 60068-2-13
Hours
m
4,850
Dimension
Cooling
min.
KAMN30
L89 x W63.5 x H25
mm
KADN30
L85.3 x W60.3 x H24.2
mm
typ.
max.
unit
VAC
Free air convection
INPUT SPECIFICATIONS
Characteristics
Rated input voltage
Input voltage range
min.
Conditions
Io nom
Ta min ... Ta max,
Io nom
Input current
Vi : 115 / 230 VAC, Io nom
Rated input current
Vi : 100 ~ 240 VAC, Io nom
Line frequency (Note 2)
Vi nom, Io nom
Inrush current
Leakage current (Note 2)
Vi : 115 / 230 VAC, Io nom
100
240
AC in
85
265
VAC
DC in
120
375
VDC
0.56 / 0.34
A
0.8 - 0.4
A
63
20/40
Hz
47
Normal condition
Single fault condition
A
μA
μA
100
300
NOTE 2 : The unit can be worked at 440 Hz of line frequency but the leakage current would be 600μA max. , and output load should be derated under 90%
OUTPUT SPECIFICATIONS
Characteristics
Output voltage accuracy
Minimum load
Line regulation
Load regulation
Conditions
Vi nom,
Io nom
Vi nom
typ.
max.
unit
single output models
±1
%
dual output models
±2
%
524D model
single output models
±4
%
0
dual output models (each output)
20
Io nom, Vi min ...Vi max
Vi nom,
Io min ...Io nom
min.
%
%
±1
%
single output models
±1
%
dual output models
±2
%
±6
%
ms
Cross regulation (Dual model)
Asymmetrical load 20% / 100% FL
Hold up time
Vi : 115 / 230 VAC, Io nom
Turn on time
Vi nom, Io nom
1,000
ms
Rise time
Vi nom, Io nom
150
ms
Fall time
Transient recovery time
Vi nom, Io nom
150
ms
Ripple & noise
Vi nom, Io nom, BW = 20MHz
External trim ADJ. Range (Note 3)
(for single output only)
Io = 5% ...100%
Efficiency
Vi nom, Io nom, Po / Pi
15 / 75
Vi nom, 1~0.5 Io nom
-10
1
ms
50
mV
+10
%
Up to 86%, See model list and typ efficiency curve
NOTE 3 : Pls refer to Fig 1 & Table 1 for connection and resistance recommended.
CONTROL AND PROTECTION
Characteristics
Conditions
min.
Input fuse
Internal surge voltage protection
www.chinfa.com
2015.02.02
max.
unit
T2A / 250VAC internal
Varistor
IEC 61000-4-5
Hiccup mode
Output short circuit
Rated over load protection
typ.
Vi nom (see typ current limited curve)
120
160
%
[email protected]
P2
KADN/KAMN30 SERIES
AC - DC POWER MODULE
SPECIFICATION
o
All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed
APPROVALS AND STANDARDS
UL / cUL
UL 60950-1, UL 60601-1 Recognized
TUV
EN 60950-1, EN 60601-1
CE
EN 60601-1-2, EN 55011, EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3
EN 61000-6-2, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5
Vibration resistance
EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, EN 61204-3
meet IEC 60068-2-6 (10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis)
Shock resistance
meet IEC 60068-2-27 (15G, 11ms, 3 axes, 6 Faces, 3 times for each Face)
PHYSICAL CHARACTERISTICS
Case size
KAMN30 : 89 x 63.5 x 25mm ( 3.5 x 2.5 x 0.98 inches)
Case material
Plastic case / PCB base
Weight
KAMN30 : 250g
Potting material
KAMN30 : Epoxy
KADN30 : 85.3 x 60.3 x 24.2mm ( 3.36 x 2.37 x 0.95 inches)
KADN30 :130g
MECHANISM & PIN CONFIGURATION
mm [inch]
60.30 [2.37]
63.50 [2.50]
2.20 [0.09]
27.90 [1.10] 27.90 [1.10]
27.90 [1.10] 27.90 [1.10]
2.20 [0.09]
3.90 [0.15]
3.85 [0.15]
5
4
5
3
4
3
KADN30
KAMN30
2-TP 3 x 8
81.20 [3.20]
81.20 [3.20] 85.30 [3.36]
89.00 [3.50]
54.50 [2.15]
54.50 [2.15]
43.30 [1.70]
45.20 [1.80]
1
1
2
2
55.80 [2.20]
55.80 [2.20]
BOTTOM VIEW
BOTTOM VIEW
24.20 [0.95]
25.00 [0.98]
GENERAL TOLERANCE
5.50 [2.20]
DIA 1.00 [0.04]
0.00[0.00] - 30.00[1.18]
±0.30[0.01]
30.00[1.18] - 120.00[4.72]
±0.50[0.02]
DIA 1.00 [0.04]
5.50 [0.22]
PIN ASSIGNMENT
GENERAL
PIN NO.
1
3
5
AC IN
AC IN
Vo +
4
Vo com
512D
AC IN
AC IN
+5V
com
+12V
524D
AC IN
AC IN
+5V
com
+24V
SINGLE
DUAL 12D, 15D
AC IN
2
AC IN
Vo +
Trim
Vo -
CIRCUIT SCHEMATIC
‧Block diagram for KAM(D)N30 series with single output
AC IN
Fuse
Vo +
Rectifier
Line
Filter
AC IN
Inrush Current
Switching
Limiter and
Device
Rectifier
Vo -
Control
Circuit
www.chinfa.com
Fuse
Opto Isolation
Reference &
Error Amp.
Trim
Vo +
Rectifier
Line
Filter
AC IN
2015.02.02
‧Block diagram for KAM(D)N30 series with dual output
Inrush Current
Switching
Limiter and
Device
Rectifier
com
Rectifier
AC IN
Control
Circuit
Opto Isolation
Vo -
Reference &
Error Amp.
[email protected]
P3
KADN/KAMN30 SERIES
AC - DC POWER MODULE
TYP. CURRENT LIMITED CURVE
CIRCUIT SCHEMATIC
v
Fuse
AC IN
Line
Filter
Inrush Current
Switching
Limiter and
Device
Rectifier
Rectifier
+5V
Rectifier
+12V or +24V
Output Voltage [ % ]
‧Block diagram for KAM(D)N30512D & KAM(D)N30524D
com
AC IN
Control
Circuit
Reference &
Error Amp.
Opto Isolation
Hiccup mode
100
50
t
Time
DERATING CURVE
100
75
Power out [ % ]
Power out [ % ]
o
Ta = -40 C
Safe Operating Area
0
-40
61
Temperature [ oC ]
100
75
Safe Operating Area
85
71
TYP. EFFICIENCY CURVE
90
115
230
Input Voltage [ VAC ]
265
Fig. 1 Trim connection
(For single output only)
KAM(D)N3024
EFFICIENCY [ % ]
85
80
5
75
4
70
230 Vac
115 Vac
65
3
Trim
5
Vo -
Rext 1
4
Vo +
3
Trim
Rext 2
Vo Vo +
60
10
25
50
Power out [ % ]
75
100
Table 1 Typical resistor values for various output voltage adjustment settings and max continuous power
Type
Rext 1
Vo nom -5%
Rext 2
Vo nom -10%
Vo nom +5%
Vo nom +10%
Max continuous power
KAM(D)N3003
20KΩ
5.1KΩ
3KΩ
1KΩ
25 W
KAM(D)N3005
5.1KΩ
1KΩ
6.8KΩ
2KΩ
30 W
KAM(D)N3012
39KΩ
20KΩ
10KΩ
0Ω
30 W
KAM(D)N3015
180KΩ
56KΩ
30KΩ
5.1KΩ
30 W
KAM(D)N3024
150KΩ
51KΩ
8.2KΩ
0Ω
30 W
www.chinfa.com
2015.02.02
[email protected]
P4