P7805-S Datasheet - NON-ISOLATED SWITCHING

For more information, please visit the product page.
date
02/19/2015
page
1 of 6
SERIES: P7805-S │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
FEATURES
•
•
•
•
•
•
•
up to 500 mA current output
operating temperature range (-40~85°C)
pin comparable to LM78 linear regulators
wider input range
suited for negative output applications
low ripple and noise
efficiency up to 96%
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
P7805-Q12-S1R5-S
12
12
4.75~28
4.75~25
1.5
-1.5
500
-400
0.75
0.6
30
35
77
66
P7805-Q12-S1R8-S
12
12
4.75~28
4.75~25
1.8
-1.8
500
-400
0.90
0.72
30
35
81
70
P7805-Q12-S2-S
12
12
4.75~28
4.75~25
2.5
-2.5
500
-400
1.25
1.0
30
35
87
73
P7805-Q24-S3-S
24
12
4.75~28
4.75~25
3.3
-3.3
500
-400
1.65
1.32
30
35
91
78
P7805-Q24-S5-S
24
12
6.5~32
6.5~27
5.0
-5.0
500
-400
2.5
2
30
35
94
83
P7805-Q24-S6-S
24
12
8~32
6.5~25
6.5
-6.5
500
-300
3.25
1.95
30
35
94
84
P7805-Q24-S9-S
24
12
11~32
7.0~23
9.0
-9.0
500
-200
4.5
1.8
30
35
95
86
P7805-Q24-S12-S
24
12
15~32
7.0~20
12
-12
500
-200
6.0
2.4
30
35
95
87
P7805-Q24-S15-S
24
12
18~32
7~17
15
-15
500
-200
7.5
3.0
30
35
96
87
Notes:
1. ripple and noise are measured at 20 MHz BW
PART NUMBER KEY
P7805 - QXX - SXX - S
Base Number
Input Voltage
Output Voltage
cui.com
Packaging Style
SIP
For more information, please visit the product page.
CUI Inc │ SERIES: P7805-S │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 02/19/2015 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
-1.5, -1.8, -2.5, -3.3 V output
1.5, 1.8, 2.5, V output
3.3 V output
-5.0 V output
5.0 V output
-6.5 V output
6.5 V output
-9.0 V output
9.0 V output
-12 V output
12 V output
-15 V output
15 V output
4.75
4.75
4.75
6.5
6.5
6.5
8
7
11
7
15
7
18
12
12
24
12
24
12
24
12
24
12
24
12
24
25
28
28
27
32
25
32
23
32
20
32
17
32
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
no-load input power
input voltage range
0.12
0.256
W
reverse polarity input
forbidden
filter
capacitance filter (1 μF)
OUTPUT
parameter
conditions/description
capacitive load
for positive output applications
for negative output applications
min
line regulation
input voltage range
load regulation
from 10% to 100% load
voltage accuracy
100% load, input voltage range
switching frequency
100% load, input voltage range
temperature coefficient
-40°C ~ 85°C
280
typ
max
units
1,000
470
μF
μF
±0.2
±0.4
%
±0.4
±0.6
%
±2
±3
%
330
450
kHz
±0.02
%/°C
max
units
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, automatic recovery
min
short circuit input power
input voltage range
over temperature protection
internal IC junction
typ
0.5
1.8
W
150
°C
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
conducted emissions
CISPR22/EN55022 class B (external circuit required, see figure 1-b)
min
radiated emissions
CISPR22/EN55022 class B (external circuit required, see figure 1-b)
ESD
IEC/EN 61000-4-2 class B, contact ± 4kV
radiated immunity
IEC/EN 61000-4-3 class A, 10V/m
EFT/burst
IEC/EN 61000-4-4 class B, ± 2kV (external circuit required, see figure 1-a)
surge
IEC/EN 61000-4-5 class B, ± 2kV (external circuit required, see figure 1-a)
conducted immunity
IEC/EN 61000-4-6 class A, 3 Vr.ms
voltage dips & interruptions
IEC/EN 61000-4-29 class B, 0%-70%
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS
2011/65/EU
2,000,000
cui.com
typ
hours
For more information, please visit the product page.
CUI Inc │ SERIES: P7805-S │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 02/19/2015 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
85
°C
-55
125
°C
100
°C
95
%
max
units
300
°C
260
°C
max
units
storage temperature
case temperature
operating temperature curve range
storage humidity
non-condensing
typ
SOLDERABILITY
parameter
conditions/description
hand soldering
1.5mm from case for 10 seconds
min
wave soldering
see wave soldering profile
typ
Peak Temp. 260°C Max.
Wave Soldering Time
4 Sec. Max.
250
Temperature (°C)
200
10 Sec. Max.
150
100
50
0
Time (sec.)
MECHANICAL
parameter
conditions/description
min
dimensions
11.60 x 7.50 x 10.20 (0.457 x 0.295 x 0.402 inch)
case material
plastic (UL94-V0)
weight
typ
mm
2.0
g
MECHANICAL DRAWING
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
Negative
Output
1
+Vin
+Vin
2
GND
-Vout
3
+Vout
GND
>@
Grid Size:
2.54mm x 2.54mm
Ф > @
> @
>@
>@
Front View
>@
>@
>@
Positive
Output
>@
Pin
>@
PIN CONNECTIONS
Bottom View
cui.com
PCB Layout
Top View
For more information, please visit the product page.
CUI Inc │ SERIES: P7805-S │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 02/19/2015 │ page 4 of 6
DERATING CURVES
Output Power (%)
Temperature Derating Curve
100
80
60
Safe operating area
40
20
-40
-20
0
20
40
60 71
85
100
Operating Temperature (°C)
EMC RECOMMENDED CIRCUIT
LDM1
FUSE
LDM2
V in
Vin
DC/DC
+
Figure 1
MOV
+Vo
GND
C1
C3
C0
C2
LOAD
GND
D
E
Recommended external circuit components
FUSE
choose according to practical input
current
MOV
S10K35
LDM1
82μH
LDM2
12μH
C0
680μF/50V
C3
4.7μF/50V
Note: See External Capacitor Table on page 5 for C1 & C2 values.
TEST CONFIGURATION
Effeciency and Output Voltage Ripple Test
25.4mm
Start-up and Load Transient Response Test
50.8 mm
25.4mm
12.7mm
2(3)
1 F
C2
+Vin
Vout
10 F
Ceramic Tantalum
1
S cope
DC/DC 3(2)
Con verter
2(3)
C1
Copper str ip
S cope
C2
GND
GND
Copper str ip
Copper str ip
OUTPUT RIPPLE REDUCTION
1
C1
L
DC/DC 3 (2 ) Vout
Co n v e rte r
2 (3 )
C2
GND
Note: To reduce ripple, it is recommended to add a LC filter in output port. (L: Recommended parameter 10μH ~ 47 μH)
cui.com
22 F
Load
+Vin
Vout
Load
Copper s tr ip
2.54 mm
C1
DC/DC
3(2)
Con verter
Load
1
2. 54 mm
+Vin
For more information, please visit the product page.
CUI Inc │ SERIES: P7805-S │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 02/19/2015 │ page 5 of 6
TYPICAL APPLICATION CIRCUIT
Figure 2
Figure 3
Positive Output Application Circuit
Negative Output Application Circuit
1
+Vin
3
C1
+Vout
2
C1
C2
GND
GND
C3
GND
LDM
2
Part Number
C2
GND
GND
C1, C3
C2, C4
(ceramic capacitor) (ceramic capacitor)
P7805-Q24-S1R5-S
10μF/50V
10μF/6.3V
P7805-Q24-S1R8-S
10μF/50V
10μF/6.3V
P7805-Q24-S2-S
10μF/50V
10μF/6.3V
P7805-Q24-S3-S
10μF/50V
10μF/6.3V
P7805-Q24-S5-S
10μF/50V
10μF/10V
P7805-Q24-S6-S
10μF/50V
10μF/16V
-Vout
2
1
C1
C4
-Vout
External Capacitor Table
+Vout
3
1
3
GND
Figure 4
Positive and Negative Output Paralleling Application Circuit
+Vin
2
1
+Vin
3
C2
P7805-Q24-S9-S
10μF/50V
10μF/16V
P7805-Q24-S12-S
10μF/50V
10μF/25V
P7805-Q24-S15-S
10μF/50V
10μF/25V
Note:
1. When the products used as negative output and the input-voltage under (Vin-min+2V), C1 and C2 must be added in the circuit, and they should be placed as near as the products' footprints. Others apply to the application-environment.
2. The capacitance of C1, C2, see external circuit table, can be increased if required, and tantalum or low ESR electrolytic capacitors may also suffice.
3. When the products used as the circuit like figure 4, an inductor named as LDM up to 10μH is recommended in the circuit to reduce the mutual interference.
4. For models ≤ 3.3 VOUT, if the input voltage of the model's negative output is less than 4.85 V, a dummy load of not less than 5 mA needs to be added to the output.
5. Cannot use in parallel for output and hot swap for input.
Note:
1. Max. capacitive load tested at input voltage range and full load.
2. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: P7805-S │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 02/19/2015 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
03/20/2013
1.01
updated EMC circuit recommendations
02/19/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.