VHK200W-DIN Datasheet - DC

For more information, please visit the product page.
date
06/16/2014
page
1 of 7
SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
up to 200 W isolated output
rugged metal enclosure with integrated heat sink
4:1 input range (10~36 Vdc, 18~75 Vdc)
single output from 12~48 Vdc
1,500 Vdc isolation
over current, over temperature, over voltage,
and short circuit protections
• remote on/off
• efficiency up to 88%
• comes with DIN-rail mount
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
range
(Vdc)
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VHK200W-Q24-S12-DIN
10 ~ 36
12
16.7
200
150
84
VHK200W-Q24-S15-DIN
10 ~ 36
15
13.3
200
150
84
VHK200W-Q24-S24-DIN
10 ~ 36
24
8.3
200
240
84
VHK200W-Q24-S28-DIN
10 ~ 36
28
7.14
200
280
87
VHK200W-Q24-S48-DIN
10 ~ 36
48
4.2
200
480
87
VHK200W-Q48-S12-DIN
18 ~ 75
12
16.7
200
150
86
VHK200W-Q48-S15-DIN
18 ~ 75
15
13.3
200
150
86
VHK200W-Q48-S24-DIN
18 ~ 75
24
8.3
200
240
86
VHK200W-Q48-S28-DIN
18 ~ 75
28
7.14
200
280
87
VHK200W-Q48-S48-DIN
18 ~ 75
48
4.2
200
480
88
Note:
1. Ripple and noise are measured at full load, 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output. The 48 Vdc output models require a 10uF
aluminum capacitor and 1uF ceramic capacitor across the output.
2. An external input capacitor of 470μF for 24 Vdc input models and 47μF for 48 Vdc input models is recommended to reduce input ripple voltage.
PART NUMBER KEY
VHK200W - QXX - SXX X - DIN
Output Voltage
Input Voltage
Base Number
cui.com
Remote On/Off Control
"blank" = positive logic
N = negative logic
Mounting Type
DIN = DIN-rail mount
For more information, please visit the product page.
CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER
date 06/16/2014 │ page 2 of 7
INPUT
parameter
conditions/description
operating input voltage
24 Vdc input models
48 Vdc input models
typ
max
units
10
18
24
48
36
75
Vdc
Vdc
24 Vdc input
power up
power down
9.5
8.5
Vdc
Vdc
48 Vdc input
power up
power down
17
16
Vdc
Vdc
under voltage shutdown
positive logic
CTRL1
negative logic
models ON (>3.5 Vdc or open circuit)
models OFF (0~1.2 Vdc)
models ON (0~1.2 Vdc)
models OFF (>3.5 Vdc or open circuit)
filter
pi filter
input fuse
40A time delay fuse for 24 Vin models,
20A time delay fuse for 48 Vin models
Note:
min
1. Open collector refer to -Vin
OUTPUT
parameter
conditions/description
maximum capacitive load
12, 15, & 24 V output models
28 V output models
48 V output models
line regulation2
load regulation2
min
typ
max
units
2,200
2,200
2,200
μF
μF
μF
measured from low line to high line
±0.2
%
measured from zero load to full load
±0.2
%
±1.5
%
100
47
voltage accuracy
adjustability
±10
switching frequency
transient response
250
25% step load change
kHz
500
temperature coefficient
Note:
%
±0.03
µs
%/°C
2. A 100 μF aluminum capacitor is required on the output for the 28 Vdc output models. A 47 μF aluminum capacitor is required on the output for 48 Vdc output models.
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous
over current protection
at 90% output voltage
min
110
over voltage protection
over temperature protection
typ
115
shutdown
max
units
160
%
140
110
%
°C
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
for 1 minute: input to output; input to case;
output to case
min
isolation resistance
RoHS
typ
max
units
1,500
Vdc
10
MΩ
2011/65/EU (CE)
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
85
°C
-55
105
°C
storage temperature
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER
date 06/16/2014 │ page 3 of 7
MECHANICAL
parameter
conditions/description
dimensions
4.23 x 4.01 x 2.07 (107.5 x 101.8 x 52.6 mm)
min
case material
steel and aluminum extrusion
typ
max
inch
weight
651
g
MECHANICAL DRAWING
units: inch[mm]
tolerance: X.XX = ±0.02[±0.5]
X.XXX = ±0.010[±0.25]
0.18 4.5
wire range: 22~12 AWG
screw size: #6-32
mounts to TS35 rails
3
REM
4
CASE
5
+Vo
4
9
6
+S
7
TRIM
4.09 104.0
8
-S
4.23 107.5
9
-Vo
Top View
2.76 70.0
2 - DIN RAIL CLIP
0.07 1.8
1.50 38.0
2.07 52.6
0.67 17.0
4.01 101.8
-Vin
0.57 14.6
2
3.62 92.0
+Vin
0.50 12.8
FUNCTION
1
1.38 35.0
Front View
Back View
Side View
OUTPUT
1.18 30.0
INPUT
1.18 30.0
1.91 48.5
0.75 19.0
PIN
5
1
PIN CONNECTIONS
Bottom View
cui.com
units
For more information, please visit the product page.
CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER
date 06/16/2014 │ page 4 of 7
DERATING CURVES
VHK200W Power Derating Curves At Nominal Input
120%
Natural
Convection
Relative Output Power - % of nominal output
100%
0.5 m/S
(100LFM)
1.0 m/S
(200LFM)
80%
1.5 m/S
(300LFM)
60%
2.0 m/S
(400LFM)
40%
2.5 m/S
(500LFM)
3.0 m/S
(600LFM)
20%
3.5 m/S
(700LFM)
0%
-40
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature - degrees C
TEST CONFIGURATION
Figure 1
Table 1
To Oscilloscope
External components
L1
+Vin
for 24 Vdc input models
+Vo
L1
+
Vin
-
Cin
1.2μH
470μF, ESR < 0.2Ω at 100 KHz
for 48 Vdc input models
-Vin
Note:
Cin
R-Load
-Vo
Input reflected-ripple current is measured with an inductor L1 to simulate source impedance.
cui.com
L1
12μH
Cin
47μF, ESR < 0.7Ω at 100 KHz
For more information, please visit the product page.
CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER
date 06/16/2014 │ page 5 of 7
EMC RECOMMENDED CIRCUITS
EN55022 CLASS A
Figure 2
Recommended Circuit for EN55022 Class A
(for all 12, 15, 24, & 28 Vdc output models)
L2
L1
+Vin
C1
+Vo
+Vin
C2
C3
+Vo
+S
DC/DC Converter
-S
-Vin
-Vin
-Vo
-Vo
CASE
C4
Figure 3
Recommended Circuit for EN55022 Class A
(for all 48 Vdc output models)
CY1
L1
+Vin
+Vin
C1
C2
C3
+Vo
+Vo
+S
DC/DC Converter
-S
-Vin
-Vin
-Vo
-Vo
CY2
Table 2
Class A Recommended Components
Model
VHK200W-Q24-S12
C11
C21
C31
CY12
CY22
L1
L2
120 μF/100 V
120 μF/100 V
NC
NC
NC
0.5 mH
SHORT
VHK200W-Q24-S15
47 μF/100 V
47 μF/100 V
NC
NC
NC
0.5 mH
SHORT
VHK200W-Q24-S24
100 μF/100 V
100 μF/100 V
NC
NC
NC
0.5 mH
SHORT
VHK200W-Q24-S28
100 μF/100 V
100 μF/100 V
NC
NC
NC
0.5 mH
SHORT
VHK200W-Q24-S48
100 μF/100 V
100 μF/100 V
100 μF/100 V
680 pF/2 KV
680 pF/2 KV
1.0 mH
NC
VHK200W-Q48-S12
82 μF/100 V
82 μF/100 V
NC
NC
NC
0.5 mH
SHORT
VHK200W-Q48-S15
82 μF/100 V
82 μF/100 V
NC
NC
NC
0.5 mH
SHORT
VHK200W-Q48-S24
82 μF/100 V
82 μF/100 V
NC
NC
NC
0.7 mH
SHORT
VHK200W-Q48-S28
150 μF/100 V
150 μF/100 V
NC
NC
NC
0.5 mH
SHORT
VHK200W-Q48-S48
100 μF/100 V
100 μF/100 V
100 μF/100 V
680 pF/2 KV
680 pF/2 KV
1.0 mH
NC
Notes:
1. Aluminum capacitors.
2. Ceramic capacitors.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER
date 06/16/2014 │ page 6 of 7
APPLICATION NOTES
1. Output Voltage Trimming
Leave open if not used.
Figure 4
Application Circuit for Trim pin
+Vin
+Vo
+Sense
R trim-up
Trim up
R-Load
Trim
-Vin
-Sense
-Vo
+Vin
+Vo
+Sense
Trim
Trim down
R-Load
R trim-down
-Vin
-Sense
-Vo
Formula for Trim Resistor
∆% = (
Vo, nom - Vo
)100
Vo, nom
Trim-Up Formula
(for all 12, 15, 24, & 281 Vdc Output Models)
Rtrim - up = (
Trim-Down Formula
(for all 12, 15, 24, & 281 Vdc Output Models)
5.11VO, nom(100 + ∆%) 511
- 10.22)(KΩ)
∆%
1.225 x ∆%
Rtrim - down = (
Trim-Up Formula
(for all 48 Vdc Output Models)
Rtrim - up = (
511
- 10.22)(KΩ)
∆%
Trim-Down Formula
(for all 48 Vdc Output Models)
20VO, nom(100 + ∆%) 2000
- 40)(KΩ)
1.225 x ∆%
∆%
Rtrim - down = (
2000
- 40)(KΩ)
∆%
Note: Rtrim-up is the external resistor in KΩ
Rtrim-down is the external resistor in KΩ
VO, nom is the nominal output voltage
VO is the desired output voltage
Notes:
1. For the 28 Vdc output models, a minimum input voltage of 10.8 Vdc is required to trim the 24 Vdc input models up 10%, and a minimum input voltage of 19 Vdc is
required to trim the 48 Vdc input models up 10%.
2. All specifications are measured at Ta=25°C, nominal input voltage and full output load unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER
date 06/16/2014 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
12/16/2013
1.01
changed DIN-rail mount
06/16/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.