For more information, please visit the product page. date 06/16/2014 page 1 of 7 SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER FEATURES • • • • • • up to 200 W isolated output rugged metal enclosure with integrated heat sink 4:1 input range (10~36 Vdc, 18~75 Vdc) single output from 12~48 Vdc 1,500 Vdc isolation over current, over temperature, over voltage, and short circuit protections • remote on/off • efficiency up to 88% • comes with DIN-rail mount MODEL input voltage output voltage output current output power ripple and noise1 efficiency range (Vdc) (Vdc) max (A) max (W) max (mVp-p) typ (%) VHK200W-Q24-S12-DIN 10 ~ 36 12 16.7 200 150 84 VHK200W-Q24-S15-DIN 10 ~ 36 15 13.3 200 150 84 VHK200W-Q24-S24-DIN 10 ~ 36 24 8.3 200 240 84 VHK200W-Q24-S28-DIN 10 ~ 36 28 7.14 200 280 87 VHK200W-Q24-S48-DIN 10 ~ 36 48 4.2 200 480 87 VHK200W-Q48-S12-DIN 18 ~ 75 12 16.7 200 150 86 VHK200W-Q48-S15-DIN 18 ~ 75 15 13.3 200 150 86 VHK200W-Q48-S24-DIN 18 ~ 75 24 8.3 200 240 86 VHK200W-Q48-S28-DIN 18 ~ 75 28 7.14 200 280 87 VHK200W-Q48-S48-DIN 18 ~ 75 48 4.2 200 480 88 Note: 1. Ripple and noise are measured at full load, 20 MHz BW with 10µF tantalum capacitor and 1µF ceramic capacitor across output. The 48 Vdc output models require a 10uF aluminum capacitor and 1uF ceramic capacitor across the output. 2. An external input capacitor of 470μF for 24 Vdc input models and 47μF for 48 Vdc input models is recommended to reduce input ripple voltage. PART NUMBER KEY VHK200W - QXX - SXX X - DIN Output Voltage Input Voltage Base Number cui.com Remote On/Off Control "blank" = positive logic N = negative logic Mounting Type DIN = DIN-rail mount For more information, please visit the product page. CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER date 06/16/2014 │ page 2 of 7 INPUT parameter conditions/description operating input voltage 24 Vdc input models 48 Vdc input models typ max units 10 18 24 48 36 75 Vdc Vdc 24 Vdc input power up power down 9.5 8.5 Vdc Vdc 48 Vdc input power up power down 17 16 Vdc Vdc under voltage shutdown positive logic CTRL1 negative logic models ON (>3.5 Vdc or open circuit) models OFF (0~1.2 Vdc) models ON (0~1.2 Vdc) models OFF (>3.5 Vdc or open circuit) filter pi filter input fuse 40A time delay fuse for 24 Vin models, 20A time delay fuse for 48 Vin models Note: min 1. Open collector refer to -Vin OUTPUT parameter conditions/description maximum capacitive load 12, 15, & 24 V output models 28 V output models 48 V output models line regulation2 load regulation2 min typ max units 2,200 2,200 2,200 μF μF μF measured from low line to high line ±0.2 % measured from zero load to full load ±0.2 % ±1.5 % 100 47 voltage accuracy adjustability ±10 switching frequency transient response 250 25% step load change kHz 500 temperature coefficient Note: % ±0.03 µs %/°C 2. A 100 μF aluminum capacitor is required on the output for the 28 Vdc output models. A 47 μF aluminum capacitor is required on the output for 48 Vdc output models. PROTECTIONS parameter conditions/description short circuit protection continuous over current protection at 90% output voltage min 110 over voltage protection over temperature protection typ 115 shutdown max units 160 % 140 110 % °C SAFETY AND COMPLIANCE parameter conditions/description isolation voltage for 1 minute: input to output; input to case; output to case min isolation resistance RoHS typ max units 1,500 Vdc 10 MΩ 2011/65/EU (CE) ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curve -40 85 °C -55 105 °C storage temperature cui.com typ For more information, please visit the product page. CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER date 06/16/2014 │ page 3 of 7 MECHANICAL parameter conditions/description dimensions 4.23 x 4.01 x 2.07 (107.5 x 101.8 x 52.6 mm) min case material steel and aluminum extrusion typ max inch weight 651 g MECHANICAL DRAWING units: inch[mm] tolerance: X.XX = ±0.02[±0.5] X.XXX = ±0.010[±0.25] 0.18 4.5 wire range: 22~12 AWG screw size: #6-32 mounts to TS35 rails 3 REM 4 CASE 5 +Vo 4 9 6 +S 7 TRIM 4.09 104.0 8 -S 4.23 107.5 9 -Vo Top View 2.76 70.0 2 - DIN RAIL CLIP 0.07 1.8 1.50 38.0 2.07 52.6 0.67 17.0 4.01 101.8 -Vin 0.57 14.6 2 3.62 92.0 +Vin 0.50 12.8 FUNCTION 1 1.38 35.0 Front View Back View Side View OUTPUT 1.18 30.0 INPUT 1.18 30.0 1.91 48.5 0.75 19.0 PIN 5 1 PIN CONNECTIONS Bottom View cui.com units For more information, please visit the product page. CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER date 06/16/2014 │ page 4 of 7 DERATING CURVES VHK200W Power Derating Curves At Nominal Input 120% Natural Convection Relative Output Power - % of nominal output 100% 0.5 m/S (100LFM) 1.0 m/S (200LFM) 80% 1.5 m/S (300LFM) 60% 2.0 m/S (400LFM) 40% 2.5 m/S (500LFM) 3.0 m/S (600LFM) 20% 3.5 m/S (700LFM) 0% -40 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature - degrees C TEST CONFIGURATION Figure 1 Table 1 To Oscilloscope External components L1 +Vin for 24 Vdc input models +Vo L1 + Vin - Cin 1.2μH 470μF, ESR < 0.2Ω at 100 KHz for 48 Vdc input models -Vin Note: Cin R-Load -Vo Input reflected-ripple current is measured with an inductor L1 to simulate source impedance. cui.com L1 12μH Cin 47μF, ESR < 0.7Ω at 100 KHz For more information, please visit the product page. CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER date 06/16/2014 │ page 5 of 7 EMC RECOMMENDED CIRCUITS EN55022 CLASS A Figure 2 Recommended Circuit for EN55022 Class A (for all 12, 15, 24, & 28 Vdc output models) L2 L1 +Vin C1 +Vo +Vin C2 C3 +Vo +S DC/DC Converter -S -Vin -Vin -Vo -Vo CASE C4 Figure 3 Recommended Circuit for EN55022 Class A (for all 48 Vdc output models) CY1 L1 +Vin +Vin C1 C2 C3 +Vo +Vo +S DC/DC Converter -S -Vin -Vin -Vo -Vo CY2 Table 2 Class A Recommended Components Model VHK200W-Q24-S12 C11 C21 C31 CY12 CY22 L1 L2 120 μF/100 V 120 μF/100 V NC NC NC 0.5 mH SHORT VHK200W-Q24-S15 47 μF/100 V 47 μF/100 V NC NC NC 0.5 mH SHORT VHK200W-Q24-S24 100 μF/100 V 100 μF/100 V NC NC NC 0.5 mH SHORT VHK200W-Q24-S28 100 μF/100 V 100 μF/100 V NC NC NC 0.5 mH SHORT VHK200W-Q24-S48 100 μF/100 V 100 μF/100 V 100 μF/100 V 680 pF/2 KV 680 pF/2 KV 1.0 mH NC VHK200W-Q48-S12 82 μF/100 V 82 μF/100 V NC NC NC 0.5 mH SHORT VHK200W-Q48-S15 82 μF/100 V 82 μF/100 V NC NC NC 0.5 mH SHORT VHK200W-Q48-S24 82 μF/100 V 82 μF/100 V NC NC NC 0.7 mH SHORT VHK200W-Q48-S28 150 μF/100 V 150 μF/100 V NC NC NC 0.5 mH SHORT VHK200W-Q48-S48 100 μF/100 V 100 μF/100 V 100 μF/100 V 680 pF/2 KV 680 pF/2 KV 1.0 mH NC Notes: 1. Aluminum capacitors. 2. Ceramic capacitors. cui.com For more information, please visit the product page. CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER date 06/16/2014 │ page 6 of 7 APPLICATION NOTES 1. Output Voltage Trimming Leave open if not used. Figure 4 Application Circuit for Trim pin +Vin +Vo +Sense R trim-up Trim up R-Load Trim -Vin -Sense -Vo +Vin +Vo +Sense Trim Trim down R-Load R trim-down -Vin -Sense -Vo Formula for Trim Resistor ∆% = ( Vo, nom - Vo )100 Vo, nom Trim-Up Formula (for all 12, 15, 24, & 281 Vdc Output Models) Rtrim - up = ( Trim-Down Formula (for all 12, 15, 24, & 281 Vdc Output Models) 5.11VO, nom(100 + ∆%) 511 - 10.22)(KΩ) ∆% 1.225 x ∆% Rtrim - down = ( Trim-Up Formula (for all 48 Vdc Output Models) Rtrim - up = ( 511 - 10.22)(KΩ) ∆% Trim-Down Formula (for all 48 Vdc Output Models) 20VO, nom(100 + ∆%) 2000 - 40)(KΩ) 1.225 x ∆% ∆% Rtrim - down = ( 2000 - 40)(KΩ) ∆% Note: Rtrim-up is the external resistor in KΩ Rtrim-down is the external resistor in KΩ VO, nom is the nominal output voltage VO is the desired output voltage Notes: 1. For the 28 Vdc output models, a minimum input voltage of 10.8 Vdc is required to trim the 24 Vdc input models up 10%, and a minimum input voltage of 19 Vdc is required to trim the 48 Vdc input models up 10%. 2. All specifications are measured at Ta=25°C, nominal input voltage and full output load unless otherwise specified. cui.com For more information, please visit the product page. CUI Inc │ SERIES: VHK200W-DIN │ DESCRIPTION: DC-DC CONVERTER date 06/16/2014 │ page 7 of 7 REVISION HISTORY rev. description date 1.0 initial release 12/16/2013 1.01 changed DIN-rail mount 06/16/2014 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.