EPSA Datasheet - AC-DC POWER SUPPLY | CUI Inc

For more information, please visit the product page.
date
05/28/2013
page
1 of 5
SERIES: EPSA 6W │ DESCRIPTION: AC-DC POWER SUPPLY
up to 6 W power
universal input (90~264 Vac)
single regulated output from 3.3~24 V
over voltage, over current, and short circuit protections
UL/cUL safety approvals
level V efficiency
custom designs available
U
•
•
•
•
•
•
•
ED
FEATURES
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
6
150
EPSA033180U
3.3
EPSA050120U
5
EPSA060100U
6
9
12
EPSA150040U
EPSA180033U
EPSA240025U
V
6
150
V
1
6
150
V
0.67
6
150
V
0.5
6
150
V
15
0.4
6
200
V
18
0.33
6
200
V
24
0.25
6
200
V
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, output terminated with 0.1 μF and 47 μF capacitors.
IS
C
PART NUMBER KEY
D
efficiency
level
1.2
O
Note:
1.8
N
EPSA090067U
EPSA120050U
TI
MODEL
N
RoHS
EPSA033180UX - XX - SZ - CXX
Base Number
example of 3.3 Vdc, 1.8 A
Reserved for Custom
Configurations
DC Plug Type
Factory
Designation
Case/Cord Color
“blank” = black
W = white
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: EPSA 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/28/2013 │ page 2 of 5
INPUT
conditions/description
min
voltage
90
frequency
47
current
leakage current
no load power consumption
OUTPUT
parameter
conditions/description
min
line regulation
conditions/description
max
units
±3
%
±10
±5
%
%
units
3,000
4,242
Vac
Vdc
parameter
conditions/description
isolation voltage
input to output at 10 mA for 1 minute
isolation resistance
input to output at 500 Vdc
safety approvals
UL/cUL, PSE, LPS
EMI/EMC
FCC
RoHS compliant
yes
min
N
100
O
conditions/description
IS
C
storage humidity
W
max
SAFETY & COMPLIANCE
operating humidity
mA
0.3
typ
protected through primary circuit IC
storage temperature
0.1
units
output shut down and auto restart
operating temperature
typ
A RMS
max
short circuit protection
parameter
Hz
0.3
typ
over voltage protection
ENVIRONMENTAL
Vac
min
N
parameter
units
264
TI
PROTECTIONS
max
63
U
3.3 V output
all other models
load regulation
typ
ED
parameter
min
MΩ
max
units
0
typ
40
°C
-10
70
°C
20
80
%
10
90
%
max
units
MECHANICAL
parameter
conditions/description
min
dimensions
59.8 x 46.1 x 26.6 (2.354 x 1.815 x 1.047 inch)
weight
fixed US
case/cord color
black or white
mm
63
D
input plug
typ
cui.com
g
For more information, please visit the product page.
CUI Inc │ SERIES: EPSA 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/28/2013 │ page 3 of 5
MECHANICAL DRAWING
O
cord length
ĸıƲIJı
D
IS
C
DC CORD
N
TI
N
U
ED
units: mm
cui.com
MODEL NO.
CABLE GAUGE
CORD LENGTH
EPSA033180U
20 AWG
1,000 mm ±100
EPSA050120U
22 AWG
1,530 mm ±100
EPSA060100U
22 AWG
1,530 mm ±100
EPSA090067U
22 AWG
1,530 mm ±100
EPSA120050U
24 AWG
1,530 mm ±100
EPSA150040U
24 AWG
1,530 mm ±100
EPSA180033U
24 AWG
1,530 mm ±100
EPSA240025U
24 AWG
1,530 mm ±100
For more information, please visit the product page.
CUI Inc │ SERIES: EPSA 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/28/2013 │ page 4 of 5
OUTPUT PLUG OPTIONS
14±0.5
ED
ø3.5 +0/-0.1
ø3.5 +0/-0.1
3.5 mm Phono Plug
14±0.5
*Tip positive
P1
P1R
C
A
B
C
Unit
2.1
9.5
mm
N
O
B
N
B
A
C
C
B
Right Angle PXR
Locking DC Plug
EIAJ Plugs
A
5.5
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
TI
Standard PX
P5/P5R
B
A
B
A
C
A
U
Standard DC Plug
EIAJ
A
B
C
D
Unit
P12/P12R
EIAJ-1
2.35
0.7
9.5
NA
mm
P13/P13R
EIAJ-2
4.0
1.7
9.5
5.0
mm
P14/P14R
EIAJ-3
4.75
1.7
9.5
5.0
mm
IS
C
C
Standard PXX
Right Angle PXXR
D
Stripped and Tinned
25±5
9±2
D
DC PLUG TYPE
ST
Stripped and Tinned
PXX X X
Plug Type
Plug Angle:
“Blank” = Standard
R = Right Angle
Plug Polarity:
“Blank” = N/A
P = Center Positive
N = Center Negative
*Contact CUI for additional output plug options.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: EPSA 6W │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/28/2013 │ page 5 of 5
REVISION HISTORY
description
date
1.0
initial release
10/24/2012
1.01
added black color option
ED
rev.
05/28/2013
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.