date 09/07/2011 page 1 of 5 SERIES: EMSA 18W │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • • up to 18W power interchangeable AC blades universal input (85-264 Vac) single regulated output from 5 to 24V short circuit protections UL/cUL, GS, RCM, and CCC safety approvals level V efficiency custom designs available RoHS output voltage output current output power ripple1 (Vdc) max (A) max (W) max (mVp-p) EMSA050300 5 3.0 15 150 V EMSA060300 6 3.0 18 150 V EMSA090200 9 2.0 18 150 V EMSA120150 12 1.5 18 150 V EMSA150120 15 1.2 18 150 V EMSA180100 18 1.0 18 180 V EMSA200090 20 0.9 18 200 V EMSA240075 24 0.75 18 240 V MODEL 1. at full load, 100 ~ 240, 20 MHz bandwidth oscilloscope, each with output terminated with a 10 μF aluminum elecrolytic and 0.1 μF ceramic capacitors. PART NUMBER KEY EMSA120150 X - XX - SZ - CXX Base Number example of 12 Vdc, 1.5 A DC Plug Type Blades: “blank” = North American, European, United Kingdom, Australian, and China blade included N = North American blade included E = European blade included B = United Kingdom blade included A = Australian blade included C = China blade included K = No blades included cui.com Factory Designation Reserved for Custom Configurations efficiency level CUI Inc │ SERIES: EMSA 18W │ DESCRIPTION: AC-DC POWER SUPPLY date 09/07/2011 │ page 2 of 5 INPUT parameter conditions/description min voltage 90 frequency 47 nom input current inrush current 5, 6 V output at 115 V ac, cold start 5, 6 V output at 230 V ac, cold start all other outputs: 115 V ac, cold start all other outputs: 230 V ac, cold start no load power consumption max units 264 Vac 63 Hz 0.6 A RMS 30 60 40 80 A A A A 0.3 W max units OUTPUT parameter conditions/description min nom line regulation ±1 % load regulation ±5 % PROTECTIONS parameter conditions/description over voltage protection output voltage clamped by internal protection zener (5 V and 6 V models only) short circuit protection Output shut down and auto restart min nom max units min nom max units 3,000 4,242 Vac Vdc SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output at 10 mA for 1 minute isolation resistance input to output at 500 V dc safety approvals UL/cUL, GS, RCM, CCC, PSE EMI/EMC FCC class B, EN55022, CE 100 MΩ leakage current RoHS compliant 0.25 mA max units yes ENVIRONMENTAL parameter conditions/description min operating temperature nom 0 40 °C storage temperature -10 75 °C operating humidity 20 80 % storage humidity 10 90 % cui.com CUI Inc │ SERIES: EMSA 18W │ DESCRIPTION: AC-DC POWER SUPPLY date 09/07/2011 │ page 3 of 5 MECHANICAL DRAWING input plug multi-blade (US, UK, Europe, Australia, China) 35.3±1.0 EMS-US EMS-AU EMS-UK EMS-EU 43.5±1.0 74±1.0 EMS-CC DC CORD Cord Length 100±20 Model no. Cable Gauge Cord Length EMSA050300 18 AWG 1530 ± 100 EMSA060300 18 AWG 1530 ± 100 EMSA090200 20 AWG 1530 ± 100 EMSA120150 20 AWG 1530 ± 100 EMSA150120 20 AWG 1530 ± 100 EMSA180100 22 AWG 1830 ± 100 EMSA200090 22 AWG 1530 ± 100 EMSA240075 22 AWG 1830 ± 100 26±3 2.8~4.0mm 100±20 80±10 48B 5ØX6mm Black wire, white stripe: Positive cui.com S&T CUI Inc │ SERIES: EMSA 18W │ DESCRIPTION: AC-DC POWER SUPPLY date 09/07/2011 │ page 4 of 5 OUTPUT PLUG OPTIONS ø3.5 +0/-0.1 ø3.5 +0/-0.1 3.5 mm Phono Plug 14±0.5 14±0.5 *Tip positive P1 P1R Standard DC Plug C Standard PX B A B A C Right Angle PXR Locking DC Plug A B C Unit P5/P5R 5.5 2.1 9.5 mm P6/P6R 5.5 2.5 9.5 mm P7/P7R 3.5 1.3 9.5 mm P8/P8R 3.8 1.35 9.5 mm P9/P9R 3.8 1.05 9.5 mm A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm B A C EIAJ Plugs B A B A C EIAJ A B C D Unit P12/P12R EIAJ-1 2.35 0.7 9.5 NA mm P13/P13R EIAJ-2 4.0 1.7 9.5 5.0 mm P14/P14R EIAJ-3 4.75 1.7 9.5 5.0 mm C Right Angle PXXR Standard PXX D Stripped and Tinned 25±5 9±2 DC PLUG TYPE ST stripped and tinned PXX X X Plug type Plug angle: “blank” = standard R = right angle Plug polarity: “blank” = N/A P = center positive N = center negative *Contact CUI for additional output plug options. cui.com CUI Inc │ SERIES: EMSA 18W │ DESCRIPTION: AC-DC POWER SUPPLY date 09/07/2011 │ page 5 of 5 REVISION HISTORY rev. 1.0 description date initial release 09/07/2011 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.