PES1-M Datasheet - DC-DC CONVERTER | CUI Inc

For more information, please visit the product page.
date
04/04/2014
page
1 of 8
SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
1 W isolated output
smaller package
single/dual unregulated outputs
3,000 Vdc isolation
continuous short circuit protection
extended temperature range (-40~105°C)
antistatic protection up to 8kV
high efficiency at light load
efficiency up to 82%
input
voltage
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
typ
(mVp-p)
typ
(%)
PES1-S3-S3-M
3.3
2.97~3.63
3.3
30
303
1
30
73
PES1-S3-S5-M
3.3
2.97~3.63
5
20
200
1
30
78
PES1-S5-S3-M
5
4.5~5.5
3.3
30
303
1
30
76
PES1-S5-S5-M
5
4.5~5.5
5
20
200
1
30
80
PES1-S5-S9-M
5
4.5~5.5
9
12
111
1
30
80
PES1-S5-S12-M
5
4.5~5.5
12
9
84
1
30
80
PES1-S5-S15-M
5
4.5~5.5
15
7
67
1
60
80
PES1-S5-S24-M
5
4.5~5.5
24
4
42
1
60
80
PES1-S5-D5-M
5
4.5~5.5
±5
±10
±100
1
60
80
PES1-S5-D9-M
5
4.5~5.5
±9
±6
±56
1
60
80
PES1-S5-D12-M
5
4.5~5.5
±12
±5
±42
1
60
81
PES1-S5-D15-M
5
4.5~5.5
±15
±3
±33
1
60
81
PES1-S5-D24-M
5
4.5~5.5
±24
±2
±21
1
60
81
PES1-S12-S3-M
12
10.8~13.2
3.3
30
303
1
30
75
PES1-S12-S5-M
12
10.8~13.2
5
20
200
1
30
80
PES1-S12-S9-M
12
10.8~13.2
9
12
111
1
30
80
PES1-S12-S12-M
12
10.8~13.2
12
9
84
1
30
81
PES1-S12-S15-M
12
10.8~13.2
15
7
67
1
60
81
PES1-S12-D5-M
12
10.8~13.2
±5
±10
±100
1
60
80
PES1-S12-D9-M
12
10.8~13.2
±9
±6
±56
1
60
80
PES1-S12-D12-M
12
10.8~13.2
±12
±5
±42
1
60
81
PES1-S12-D15-M
12
10.8~13.2
±15
±3
±33
1
60
81
PES1-S12-D24-M
12
10.8~13.2
±24
±2
±21
1
60
81
PES1-S15-S15-M
15
13.5~16.5
15
7
67
1
60
81
PES1-S24-S5-M
24
21.6~26.4
5
20
200
1
30
80
PES1-S24-S9-M
24
21.6~26.4
9
11
110
1
30
80
PES1-S24-S15-M
24
21.6~26.4
15
7
67
1
60
81
PES1-S24-S24-M
24
21.6~26.4
24
4
42
1
60
81
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
input
voltage
MODEL
(CONTINUED)
date 04/04/2014 │ page 2 of 8
output
voltage
output
current
output
power
ripple
and noise1
efficiency
max
(W)
typ
(mVp-p)
typ
(%)
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
PES1-S24-D5-M
24
21.6~26.4
±5
±10
±100
1
60
82
PES1-S24-D9-M
24
21.6~26.4
±9
±6
±56
1
60
82
PES1-S24-D12-M
24
21.6~26.4
±12
±5
±42
1
60
82
PES1-S24-D15-M
24
21.6~26.4
±15
±3
±33
1
60
82
PES1-S24-D24-M
24
21.6~26.4
±24
±2
±21
1
60
82
Notes:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PES1 - SXX - XXX - M - X
Base Number
Input Voltage
Output
S = single
D = dual
Output Voltage
Packaging Style
"blank" = tube
TR = tape & reel
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
2.97
4.5
10.8
13.5
21.6
3.3
5
12
15
24
3.63
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
Vdc
surge voltage
for maximum of 1 second
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
-0.7
-0.7
5
9
18
21
30
Vdc
Vdc
Vdc
Vdc
Vdc
filter
capacitance filter
max
units
±1.5
±1.2
%
%
OUTPUT
parameter
conditions/description
line regulation
for Vin change of 1%
3.3 Vdc output models
all other models
min
load regulation
measured from 10% load to full load
3.3 Vdc output models
5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
voltage accuracy
see tolerance envelope curve
switching frequency
100% load, nominal input voltage
temperature coefficient
100% load
cui.com
typ
%
%
%
%
%
%
18
12
8
7
6
5
100
300
kHz
±0.03
%/°C
For more information, please visit the product page.
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 3 of 8
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, automatic recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA max.
3,000
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
conducted emissions
CISPR22/EN55022 class B (external circuit required, see Figure 1)
radiated emissions
CISPR22/EN55022 class B (external circuit required, see Figure 1)
ESD
IEC/EN61000-4-2, class B, contact ± 8kV for single outputs
IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS
2011/65/EU
3,500,000
hours
ENVIRONMENTAL
parameter
conditions/description
operating temperature
see derating curve
min
storage temperature
storage humidity
non-condensing
temperature rise
at full load, Ta = 25°C
typ
max
units
-40
105
°C
-55
125
°C
95
25
%
°C
SOLDERABILITY
parameter
conditions/description
max
units
hand soldering
1.5 mm from case for 10 seconds
min
300
°C
reflow soldering
see reflow soldering profile
245
°C
250
245
Peak.Temp 245ć(Max.)
217
Tem peratur e (đ)
200
typ
60 Sec Max
(> 217ć)
150
100
50
0
Ti me (sec.)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 4 of 8
MECHANICAL
parameter
conditions/description
dimensions
single output models: 12.70 x 8.30 x 7.25
dual output models: 15.24 x 8.30 x 7.25
min
case material
epoxy resin (UL94-V0)
weight
single output models
dual output models
typ
max
units
mm
mm
1.5
1.8
g
g
MECHANICAL DRAWING
SINGLE OUTPUT MODELS
12.70± 0.20
[0.500± 0.008]
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
0.60± 0.10
[0.020± 0.004]
GND
2
Vin
4
0V
5
+Vo
8
NC
8
5
1 2
1.00 [0.039]
2.54± 0.20
[0.100± 0.08]
4
A
°
Single Output
1
0~ 5
PIN
8.30± 0.20
[0.327± 0.008]
PIN CONNECTIONS
2.54
[0.100]
7.62
[0.300]
9.77± 0.20
[0.385± 0.079]
1
2
4
2.25
[0.089]
7.00
[0.276]
7.25
[0.285]
5
2.10 [0.083]
10.20 [0.402]
Top View
8
A
0.10
2.54
[0.100]
Grid Size:
2.54mm x 2.54mm
0.25± 0.10
[0.010± 0.004]
Front View
7.62
[0.300]
0.88± 0.20
[0.035± 0.008]
1.45± 0.20
[0.057± 0.008]
11.20± 0.30
[0.441± 0.012]
Side View
PCB Layout
Top View
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 5 of 8
MECHANICAL DRAWING (CONTINUED)
DUAL OUTPUT MODELS
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
Dual Output
1
GND
2
Vin
4
0V
5
-Vo
7
+Vo
10
NC
Top View
Front View
Top View
PCB Layout
cui.com
Side View
For more information, please visit the product page.
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 6 of 8
DERATING CURVES
Tolerance Envelope Curve
Temperature Derating Curve
7.5
100
5
Typica
l
2.5
Load
Line
2.5
Load (%)
Output Voltage Accuracy (%)
10
Rated Output Voltage
0
-2.5
-2.5
80
60
Safe operating area
40
-5
20
-7.5
-7.5
-10
10
20
30
40
50
60
70
80
90
100
-40
-20
Output Current Percentage (%)
(Nominal Input Voltage)
0
20
40
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
Single Output Models
Recommended External Circuit Components
LDM
Vi n
Vi n
+Vo
L O AD
C0
GND
GND
0V
Vin
(Vdc)
C0
LDM
3.3
4.7μF/50V
6.8μH
5
4.7μF/50V
6.8μH
12
4.7μF/50V
6.8μH
15
4.7μF/50V
6.8μH
24
4.7μF/50V
6.8μH
Dual Output Models
LDM
Vin
Vin
+Vo
LOAD
C0
GND
GND
-Vo
TEST CONFIGURATION
Figure 2
Table 2
Oscilloscope
External components
Lin
Cin
Current
Probe
DC DC
60
Ambient Temperature (°C)
Load
Lin
4.7μH
Cin
220μF, ESR < 1.0Ω
at 100 KHz
Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
cui.com
100 105 120
For more information, please visit the product page.
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 7 of 8
APPLICATION NOTES
1.
Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2.
Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3.
Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR(see Figure 3 & Table 3). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 4).
Figure 3
Single Output
Dual O ut put
+Vo
Vin
Cout
DC DC
Cin
GND
+Vo
Vin
Cout
DC DC
Cin
GND
0V
Cout
0V
-Vo
Table 3
Table 4
Vin
(Vdc)
Cin
(μF)
Single Vo
(Vdc)
Cout
(μF)
Dual Vo
(Vdc)
Cout
(μF)
Single Vout
(Vdc)
Max. Capacitive Load
(μF)
Dual Vout
(Vdc)
Max. Capacitive Load1
(μF)
3.3
4.7
3.3
10
--
--
3.3
220
--
--
5
100
5
4.7
5
10
±5
4.7
5
220
--
--
9
4.7
±9
2.2
9
220
9
100
12
2.2
12
2.2
±12
1
12
220
12
100
15
2.2
15
1
±15
1
15
220
15
100
24
1
24
0.47
±24
0.47
24
220
24
100
Note:
4.
It’s not recommended to connect any external capacitors in
applications with less than 0.5 watt output.
Note:
1. For each output.
Output Voltage Regulation and Over-voltage Protection Circuit
The device for output voltage regulation, over-voltage and over-current protection is a linear regulator and a capacitor filtering network with overheat protection, which can be connected to the input or output end in series (see Figure 4). The recommended capacitance of its filter capacitor (see Table 4), and the linear regulator is based on the actual voltage and current required.
Single Output
Vin
REG
REG
+Vo
DC DC
GND
0V
Figure 4
Dual Output
Vin
REG
REG
0V
DC DC
GND
Note:
1.
2.
3.
4.
+Vo
REG
-Vo
Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
Max. capacitive load tested at input voltage range and full load.
It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure.
All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 8 of 8
REVISION HISTORY
rev.
description
date
1.0
initial release
03/19/2013
1.01
added models, updated spec
04/04/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.