PQMC1-S Datasheet - DC-DC CONVERTER | CUI Inc

For more information, please visit the product page.
date
10/14/2014
page
1 of 6
SERIES: PQMC1-S │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
1 W isolated output
smaller package
single/dual regulated output
1,500 Vdc isolation
short circuit protection
temperature range (-40~105°C)
high efficiency at light load
efficiency up to 81%
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PQMC1-D5-S5-S
5
4.5~9
5
10
200
1
75
72
PQMC1-D5-S12-S
5
4.5~9
12
4
83
1
75
76
PQMC1-D5-S15-S
5
4.5~9
15
3
67
1
75
75
PQMC1-D5-D5-S
5
4.5~9
±5
±5
±100
1
75
73
PQMC1-D5-D12-S
5
4.5~9
±12
±2
±42
1
75
76
PQMC1-D5-D15-S
5
4.5~9
±15
±2
±33
1
75
75
PQMC1-D12-S3-S
12
9~18
3.3
15
303
1
75
75
PQMC1-D12-S5-S
12
9~18
5
10
200
1
75
77
PQMC1-D12-S9-S
12
9~18
9
6
111
1
75
79
PQMC1-D12-S12-S
12
9~18
12
4
83
1
75
80
PQMC1-D12-S15-S
12
9~18
15
3
67
1
75
80
PQMC1-D12-D5-S
12
9~18
±5
±5
±100
1
75
78
PQMC1-D12-D12-S
12
9~18
±12
±2
±42
1
75
81
PQMC1-D12-D15-S
12
9~18
±15
±2
±33
1
75
80
PQMC1-D24-S3-S
24
18~36
3.3
15
303
1
75
75
PQMC1-D24-S5-S
24
18~36
5
10
200
1
75
77
PQMC1-D24-S12-S
24
18~36
12
4
83
1
75
81
PQMC1-D24-S15-S
24
18~36
15
3
67
1
75
79
PQMC1-D24-S24-S
24
18~36
24
2
42
1
75
77
PQMC1-D24-D5-S
24
18~36
±5
±5
±100
1
75
80
PQMC1-D24-D12-S
24
18~36
±12
±2
±42
1
75
80
PQMC1-D24-D15-S
24
18~36
±15
±2
±33
1
75
80
PQMC1-D48-S3-S
48
36~75
3.3
15
303
1
75
75
PQMC1-D48-S5-S
48
36~75
5
10
200
1
75
76
PQMC1-D48-S12-S
48
36~75
12
4
83
1
75
81
PQMC1-D48-S15-S
48
36~75
15
3
67
1
75
80
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC1-S │ DESCRIPTION: DC-DC CONVERTER
MODEL
(CONTINUED)
input
voltage
typ
(Vdc)
range
(Vdc)
PQMC1-D48-D5-S
48
PQMC1-D48-D12-S
48
PQMC1-D48-D15-S
48
Notes:
date 10/14/2014 │ page 2 of 6
output
voltage
output
current
output
power
ripple
and noise1
efficiency
(Vdc)
min
(mA)
max
(mA)
max
(W)
typ
(mVp-p)
typ
(%)
36~75
±5
±5
±100
1
75
76
36~75
±12
±2
±42
1
75
80
36~75
±15
±2
±33
1
75
80
1. ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PQMC1 - DXX - XXX - S
Base Number
Input Voltage
INPUT
Output
S = single
D = dual
Output Voltage
Packaging Style
SIP
parameter
conditions/description
min
typ
max
units
operating input voltage
5 Vdc input models
12 Vdc input models
24 Vdc input models
48 Vdc input models
4.5
9
18
36
5
12
24
48
9
18
36
75
Vdc
Vdc
Vdc
Vdc
start-up voltage
5 Vdc input models
12 Vdc input models
24 Vdc input models
48 Vdc input models
3.5
4.5
11
24
4
8
16
33
4.5
9
18
36
Vdc
Vdc
Vdc
Vdc
surge voltage
for maximum of 1 second
5 Vdc input models
12 Vdc input models
24 Vdc input models
48 Vdc input models
-0.7
-0.7
-0.7
-0.7
12
25
50
100
Vdc
Vdc
Vdc
Vdc
filter
capacitance filter
models ON (CTRL open or insulated)
CTRL2
Notes:
models OFF (connect voltage, current into CTRL is
5~10mA)
2. See application notes on page 5.
OUTPUT
parameter
conditions/description
typ
max
units
line regulation
full load, input voltage from low to high
min
±0.2
±0.5
%
load regulation
5% to 100% load
±0.4
±0.75
%
voltage accuracy
5% to 100% load
no-load voltage accuracy
±1
±3
%
±1.5
±5
%
±0.5
voltage balance
dual output, balanced loads
±0.3
switching frequency
100% load, nominal input voltage, PFM mode
200
transient recovery time
25% load step change
0.5
2
ms
transient response deviation
25% load step change
±2.5
±5
%
temperature coeffecient
100% load
±0.02
±0.03
%/°C
max
units
3
Notes:
%
kHz
3. For dual output models, unbalanced loads should not exceed ±5%. If ±5% is exceeded, it may not meet all specifications.
PROTECTIONS
parameter
conditions/description
short circuit protection
automatic recovery
min
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2014 │ page 3 of 6
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA max.
1,500
min
typ
max
Vdc
isolation resistance
input to output at 500 Vdc
1,000
MΩ
conducted emissions
CISPR22/EN55022, class B (external circuit required, see Figure 1-b)
radiated emissions
CISPR22/EN55022, class B (external circuit required, see Figure 1-b)
ESD
IEC/EN61000-4-2, class B, contact ± 4kV
radiated immunity
IEC/EN61000-4-3, class A, 10V/m
EFT/burst
IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a)
surge
IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a)
conducted immunity
IEC/EN61000-4-6, class A, 3 Vr.m.s
voltage dips & interruptions
IEC/EN61000-4-29, class B, 0%-70%
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS
2011/65/EU
1,000,000
units
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
storage temperature
storage humidity
non-condensing
temperature rise
at full load, Ta=25°C
typ
max
units
-40
105
°C
-55
125
°C
95
%
25
°C
SOLDERABILITY
parameter
conditions/description
max
units
hand soldering
1.5 mm from case for 10 seconds
min
typ
300
°C
wave soldering
see wave soldering profile
260
°C
max
units
MECHANICAL
parameter
conditions/description
dimensions
22.00 x 9.50 x 12.00 (0.866 x 0.374 x 0.472 inch)
min
case material
plastic (UL94-V0)
typ
mm
weight
4.9
g
Single Output
Dual Output
1
GND
GND
2
Vin
Vin
3
Ctrl
Ctrl
5
NC
NC
6
+Vo
+Vo
7
0V
0V
8
CS
-Vo
Grid Size:
2.54mm x 2.54mm
1
2
3
Ø1.00 [0.039]
5
6
4.10 [0.161]
Front View
2.54[0.100]
22.00 [0.866]
1
2
3
5
6
2.50
[0.098]
NC: No Connection
0.50[0.020]
17.78 [0.700]
Bottom View
cui.com
0.30 [0.012]
PIN
12.00
[0.472]
PIN CONNECTIONS
9.50
[0.374]
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
0.50[0.020]
MECHANICAL DRAWING
7
8
PCB Layout
Top View
7
8
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2014 │ page 4 of 6
DERATING CURVES
Wave Soldering Profile
Temperature Derating Curve
Peak Temp. 260°C Max.
Wave Soldering Time
4 Sec. Max.
250
100
80
Load (%)
Temperature (°C)
200
10 Sec. Max.
150
60
Safe operating area
40
100
20
50
-40
0
-20
0
20
40
60
85
105
Ambient Temperature (°C)
Time (sec.)
EMC RECOMMENDED CIRCUIT
LDM1
FUSE
Vin
LDM2
Vin
+
Figure 1
MOV
TVS
C0
CTRL
C1
D1
CTRL
C2
Cd
GND
(b)
(a)
+Vo
R
CY
EUT
GND
LOAD
-Vo
(0V)
(c)
Recommended external circuit components
Vin (Vdc)
5
FUSE
12
24
48
choose according to practical input current
MOV
--
--
S14K35
S14K60
LDM1
--
--
56μH
56μH
TVS
SMCJ13A
SMCJ28A
SMCJ48A
SMCJ90A
C0
680μF/16V
680μF/25V
330μF/50V
330μF/100V
Table 1
C1
4.7μF/50V
4.7μF/50V
4.7μF/100V
4.7μF/100V
LDM2
12μH
12μH
12μH
12μH
C2
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/100V
CY
1nF/2kV
1nF/2kV
1nF/2kV
1nF/2kV
D1
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
V − VD − 1.0
−300
R= C
Follows:aaaaa
aaaaaaaaaaaa
IC
R
Cd
47nF/100V
47nF/100V
47nF/100V
47nF/100V
Note: Figure 1-c is on/off control circuit. See page 5 for details.
TEST CONFIGURATION
Oscilloscope
Lin
Figure 2
Note:
Lin(4.7µH)
Cin
External components
Current
Probe
DC DC
Load
Cin(220µF, ESR < 1.0Ω at 100 KHz)
Table 2
Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
cui.com
Lin
4.7μH
Cin
220μF, ESR < 1.0Ω
at 100 kHz
120
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2014 │ page 5 of 6
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 5% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Recommended circuit
This series has been tested according to the following recommended testing circuit before leaving the factory. This series should
be tested under load (see Figure 3 and Table 3). If you want to further decrease the input/output ripple, you can increase the
capacitance accordingly or choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be
appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable
operation, the maximum capacitance must be less than the maximum capacitive load (see Table 4).
Single output
/LQ 9LQ
Dual output
/LQ 9LQ
9R
*1'
&G
9F
&V
' ,F 5
&RXW
9F
&G
' ,F 5
9R
9
&RXW
/RXW
*1'
9
9R
&RXW
/RXW
&LQ &LQ
&LQ &LQ
Figure 3
Table 3
Table 4
Vin
(Vdc)
Cin1
(µF)
Cin2
(µF)
Lin
(µH)
Cs1
(µF)
Cout
(µF)
Lout2
(µH)
Cd
(nF/V)
5
100
47
4.7~12
10~22
100
2.2~10
47/100
12
100
47
4.7~12
10~22
100
2.2~10
47/100
24
10
1
4.7~12
10~22
100
2.2~10
47/100
48
10
1
4.7~12
10~22
100
2.2~10
47/100
Note:
Single
Vout
(Vdc)
Max. Capacitive
Load
(μF)
Dual
Vout
(Vdc)
Max. Capacitive
Load1
(μF)
3.3
2700
--
--
5
2200
5
1000
9
1800
--
--
12
1000
12
470
1. For single output only
2. For dual output only
15
680
15
330
24
Note:
470
--
--
1. For each output.
3. CTRL Terminal
When open or applied high impedance, the converter will turn on. When it’s pulled high, the converter will shutdown. The input
current should between 5~10mA. Exceeding the maximum 20mA will cause permanent damage to the converter. The value for R can
be derived as follows:
V − VD − 1.0
−300
R= C
IC
Vi n
Vc: Control pin input voltage
VD: Forward voltage drop of diode D1
IC: Input current to control pin
R: Resistor of control circuit
Figure 4
Vc
D1
R
C trl
Cd
GND
+Vo
EUT
L O AD
-Vo
(0 V)
Figure 5
Input Current(A)
4. Input Current
When it is used in an unregulated condition, make sure that the input fluctuations and ripple voltage do not exceed the module
standard. Refer to Figure 5 and Table 5 for the startup current of this dc-dc module.
Ip
Table 5
Input Voltage
Range
Input Voltage (V)
Note:
Vin
(Vdc)
Ip
(mA)
5
450
12
220
24
110
48
55
1. Minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. Operation under minimum load will not damage the converter, however, they may not meet all specifications listed.
2. Maximum capacitive load is tested at input voltage range and full load.
3. All specifications are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC1-S │ DESCRIPTION: DC-DC CONVERTER
date 10/14/2014 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
03/20/2013
1.01
added models, updated spec
10/14/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.