VMS-160 Datasheet - AC-DC POWER SUPPLY | CUI Inc

For more information, please visit the product page.
date
01/30/2014
page
1 of 5
SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
•
•
up to 160 W continuous power
industry standard 2” x 4” footprint
18 W/in3 power density
universal input (85~264 Vac / 125~373 Vdc)
single output from 5~48 V
active power correction (98%)
12 V auxiliary fan output
no minimum load required
over load, over voltage, and short circuit protections
full medical and ITE safety approvals
efficiency up to 90%
MODEL
VMS-160-5
output
voltage
output
current
output
power
ripple and
noise4
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
5
20
1001
50
90
VMS-160-12
12
13.3
160
120
90
VMS-160-15
15
8
1202
50
90
VMS-160-24
24
6.66
1603
240
90
VMS-160-48
48
3.33
1603
480
90
Notes:
1.
2.
3.
4.
3
Total continuous output power will not exceed 100 W forced air (400 LFM), 70 W without fan
Total continuous output power will not exceed 120 W forced air (400 LFM), 90 W without fan
Total continuous output power will not exceed 160 W forced air (400 LFM), 100 W without fan
Measured at 20 MHz, twisted pair with 0.47 μF ceramic and 22 μF tantalum parallel capacitors
PART NUMBER KEY
VMS-160 - XX
Base Number
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/30/2014 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
frequency
current
max
units
90
125
typ
264
373
Vac
Vdc
47
63
Hz
2.5
1.25
A
A
max
units
at 100 Vac, cold start
at 200 Vac, cold start
inrush current
at 230 Vac, full load, cold start
power factor correction
measured at full load and 115 Vac/60 Hz and
230 Vac/50 Hz input source input will be less than
0.25Ω, compliant to EN61000-3-2 for harmonic
currents
0.85
0.98
parameter
conditions/description
min
typ
line regulation
low line to high line
load regulation
all other outputs
12 V aux. output
OUTPUT
temperature coefficient
transient response
%
±1
±20
%
%
0.25
mV/°C
25% Imax to Imax , 0.1 A/μs slew rate, ±5% max. deviation, 1 ms recovery
start-up
1
rise time
0.2
hold-up
16
adjustability
fan drive
±1
s
20
ms
ms
±5
%
12 Vdc / 500 mA for external fan
PROTECTIONS
parameter
conditions/description
min
typ
over voltage protection
over current protection
automatically recovers
short circuit protection
auto recovery with no damage from a short on any
output
max
units
130
%
150
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
primary to secondary (for 1 second):
primary to earth ground (for 1 second):
typ
5,656
5,656
Vdc
Vdc
safety approvals
UL 60950-1/60601-1, NEMKO EN 60950-1/EN 60601-1, CE
EMI/EMC
EN 55022:1998 (CISPR 22 class A at 10 meters, radiated), EN 55022:1998 (Class B, conducted), EN
61000-3-2: 2000, EN 61000-3-3: A1:2001, EN 55024 (IEC 61000-4-2: 1995, IEC 61000-4-3: 1995,
IEC 61000-4-4: 1995, IEC 61000-4-5: 1995, IEC 61000-4-6: 1996, IEC 61000-4-11: 1994)
leakage current
measured per IEC 60950-1, paragraph 5.1,
test voltage of 120 Vac/60 Hz
MTBF
with 400 LFM forced air, MIL-HDBK-217E-1, 75%
of rated full load, 25°C ambient
RoHS
2011/65/EU
cui.com
275
200,000
μA
hrs
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/30/2014 │ page 3 of 5
ENVIRONMENTAL
parameter
conditions/description
min
typ
max
units
operating temperature
see derating curve
-20
70
°C
storage temperature
see derating curve
operating humidity
storage humidity
non-condensing
non-condensing
-40
80
°C
8
90
95
%
%
shock
operating (11 ms, half sine, for a total of 6 shock inputs)
non-operating (2 ms, half sine, for a total of 6 shock inputs)
10
140
G
G
vibration
operating (10 ~ 300 Hz, 1 hour per axis, 3 hours total)
non-operating (10 ~ 500 Hz, 1 hour per axis, 3 hours total)
1
2
Grms
Grms
DERATING CURVE
output power vs. ambient temperature
Load (%)
100
80
60
50
40
20
-20
-10
0
10
20
30
40
Ambient Temperature (°C)
cui.com
50
60
70
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/30/2014 │ page 4 of 5
MECHANICAL DRAWING
MOLEX (22-23-2041)
4 PIN
0.10 SPACING
101.6 4.000
95.3 3.752
MAX DIA OF MOUNTING HARDWARE
Ø6.35 (Ø0.250)
TYP 4 PLCS
Ø4.04 (Ø0.159)
MOUNTING HOLE
TYP 4 PLCS
1
4
8
50.8 2.000
1
MOLEX (26-60-4030)
3 PIN, CTR PIN REMOVED
0.156 SPACING
44.5 1.752
2
1
QUICK DISCONNECT TAB
6.35 (0.250) X 0.81 (0.032)
MOLEX (19705-4301)
MOLEX (26-60-4080)
8 PIN
0.156 SPACING
21.59 0.850
27.5 1.082
4.4 0.173 MAX
SMT COMPONENT
HEIGHT
CN1
CN2
1
ac neutral
1
dc return
2
ac line
2
dc return
3
dc return
4
dc return
CN3
1
GND
5
V1
2
GND
6
V1
3
12V (fan)
7
V1
4
12V (fan)
8
V1
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/30/2014 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
05/5/2009
1.01
new template applied
06/16/2011
1.02
V-Infinity branding removed
08/15/2012
1.03
corrected power output data, updated derating curve
11/02/2012
1.04
corrected CN3 connector part number
12/04/2012
1.05
updated EMI/EMC section
01/30/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.