FEATURES
•
•
•
•
•
•
•
up to 60 W continuous power
universal input (85~264 Vac / 120~370 Vdc)
dual output
overload, over voltage, and short circuit protections
UL/cUL and Intertek 60950-1 safety approvals
built-in EMI filter
efficiency up to 80%
MODEL
output
voltage
output
current
output
power1
ripple
and noise2
efficiency
(Vdc)
min
(A)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VGD-60-D512
5
12
0.3
0.3
6
4
60
80
120
79
VGD-60-D524
5
24
0.3
0.3
6
2.2
60
80
240
80
Notes:
1. Maximum total combined power.
2. Ripple & noise are measured at 20 MHz BW with 47 μF aluminum electrolytic capacitor and 0.1 μF ceramic capacitor on the output.
PART NUMBER KEY
VGD-60 - DXXX
Base Number
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VGD-60 │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/15/2014 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
frequency
max
units
85
120
typ
264
370
Vac
Vdc
47
63
Hz
input current
115 Vac
230 Vac
1.5
0.7
A
A
inrush current
115 Vac, full load, cold start
230 Vac, full load, cold start
30
60
A
A
max
units
OUTPUT
parameter
conditions/description
min
line regulation
typ
±1
load regulation
temperature coefficient
%
±5
%
±0.03
%/°C
hold-up time
115 Vac, full load
230 Vac, full load
10
50
ms
ms
adjustability
adjustable with built-in trim pot1
±5
%
Note:
1. Adjustment of 5 V output only.
PROTECTIONS
parameter
conditions/description
min
over voltage protection
shut down and latch off, recover after restart.
overload protection
hiccup mode, automatically recovers
short circuit protection
continuous, automatically recovers
typ
110
max
units
7
V
160
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output
input to case
output to case
isolation resistance
input to output at 500 Vdc @ 25°C
safety approvals
UL 60950-1, Intertek EN 60950-1
EMI/EMC
EN 55022 (CISPR22) Class B, EN 61000 -3-2,-3,-4-2,3,4,5,6,8,11; EN 55024
leakage current
at 240 Vac
MTBF
MIL-HDBK-217F(25°C)
RoHS
2011/65/EU
min
typ
3,000
1,500
500
Vac
Vac
Vac
100
MΩ
3.5
300,000
mA
hrs
ENVIRONMENTAL
parameter
conditions/description
operating temperature
see derating curve
min
storage temperature
operating humidity
non-condensing
storage humidity
cui.com
typ
max
units
-10
60
°C
-20
85
°C
20
90
%
10
95
%
For more information, please visit the product page.
CUI Inc │ SERIES: VGD-60 │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/15/2014 │ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
129 x 98 x 38 (5.1 x 3.9 x 1.5 inch)
min
cooling method
free air convection (see derating curve below)
typ
max
mm
weight
433
g
DERATING CURVES
MECHANICAL DRAWING
units mm[inches]
tolerance:
±0.3mm unless otherwise specified
8.20 0.323
9.50 0.374
6.50 0.256
9.00 0.354
120.00 4.724
3.50 0.138
9.50 0.374
18.00 0.709
18.50 0.728
38.00 1.496
28.50 1.122
3.50 0.138
32.50 1.280
M3 (3 PLCS)
75.50 2.972
129.00 5.079
73.50 2.894
3.50 0.138
(2 PLCS)
M3 (2 PLCS)
85.50 3.366
33.00 1.299
98.00 3.858
31.00 1.220
4.50 0.177
122.50 4.823
units
7.00 0.276
3.50 0.138
cui.com
PIN CONNECTIONS
Pin
Function
1
ac line
2
ac neutral
3
FG
4
COM
5
+V2
6
COM
7
+V1
For more information, please visit the product page.
CUI Inc │ SERIES: VGD-60 │ DESCRIPTION: AC-DC POWER SUPPLY
date 01/15/2014 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
10/26/2011
1.01
updated capacitor values for ripple measurements
04/20/2012
1.02
V-Infinity branding removed
08/21/2012
1.03
added minimum current requirements
10/29/2013
updated drawing
01/15/2014
1.04
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.