For more information, please visit the product page. date 04/30/2015 page 1 of 4 SERIES: SWI5-E-USB │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • 5 W power level VI efficiency universal input (90~264 Vac) single regulated 5 Vdc output over voltage, over current, and short circuit protections GS safety approval MODEL SWI5-5-E-I38 Notes: output voltage output current output power ripple and noise1 (Vdc) max (A) max (W) max (mVp-p) 5 1 5 300 efficiency level VI 1. At full load, nominal input, 25 °C, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 μF ceramic and 10 μF electrolytic capacitors. PART NUMBER KEY SWI5 - 5 - E - I38 - CXX Base Number Reserved for Custom Configurations Output Voltage AC Input Type: Europe cui.com USB Type A Inlet For more information, please visit the product page. CUI Inc │ SERIES: SWI5-E-USB │ DESCRIPTION: AC-DC POWER SUPPLY date 04/30/2015 │ page 2 of 4 INPUT parameter conditions/description min voltage 90 frequency 47 typ current leakage current no load power consumption at 115/230 Vac, 50/60 Hz max units 264 Vac 63 Hz 0.2 A 0.02 mA 0.075 W max units OUTPUT parameter conditions/description min typ line regulation ±5 load regulation ±5 start-up time % % 3 s max units PROTECTIONS parameter conditions/description min typ over voltage protection over current protection auto recovery 10 Vdc 1.5 A max units short circuit protection SAFETY & COMPLIANCE parameter conditions/description min isolation voltage input to output at 10 mA for 1 minute safety approvals GS (EN60950-1) EMI/EMC CE MTBF as per Telcordia SR-332, Issue 2, at 115/230 Vac, full load, 0~40°C RoHS 2011/65/EU typ 3,000 4,242 Vac Vdc 50,000 hours ENVIRONMENTAL parameter conditions/description min operating temperature storage temperature max units 0 typ 40 °C -20 60 °C operating humidity non-condensing 20 85 % storage humidity non-condensing 5 95 % cui.com For more information, please visit the product page. CUI Inc │ SERIES: SWI5-E-USB │ DESCRIPTION: AC-DC POWER SUPPLY date 04/30/2015 │ page 3 of 4 MECHANICAL parameter conditions/description dimensions 84.82 x 36 x 22.5 input plug Europe min typ 80 MECHANICAL DRAWING units: mm tolerance: ±0.5 mm Output Voltage 1 +5V 2 Short 3 Short 4 GND +5 GND units mm weight PIN max 1 4 cui.com g For more information, please visit the product page. CUI Inc │ SERIES: SWI5-E-USB │ DESCRIPTION: AC-DC POWER SUPPLY date 04/30/2015 │ page 4 of 4 REVISION HISTORY rev. 1.0 description date initial release 04/30/2015 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.