MODEL: CPM-2F │ DESCRIPTION: 6.0 A PELTIER UNIT
FEATURES
• better seal structure for water resistance and
absorbtion of thermal stress
• easy installation
• no screws to tighten result in better heat
absorbtion and maximum performance
RoHS
MODEL
CPM-2F
Notes:
input
voltage1
input
current
output
Qmax2
output
∆Tmax2
max
(V)
max
(A)
Th=50°C
(W)
Th=50°C
(°C)
12
6
46
73
1. at inverse voltage, "cold side plate" becomes hot side plate
2. maximum cooling capacity at Imax, Vmax, and ∆T=0°C
3. maximum temperature difference at Imax, Vmax, and Q=0W (maximum parameters are measured in a vacuum)
GENERAL
parameter
conditions/description
min
typ
max
units
internal resistance
1.85
2.35
Ω
cold side plate
-20
60
°C
max
units
1,200
Vac
4
Notes:
4. measured by AC 4-terminal method at 25°C
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
for 1 second
insulation resistance
input to output at 250 Vdc
RoHS compliant
yes
min
typ
10
MΩ
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
typ
max
units
0
35
°C
storage temperature
-20
70
°C
operating humidity
30
85
%
storage humidity
10
90
%
For further information and product selection refer to peltier applicaftion notes.pdf
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: CPM-2F │ DESCRIPTION: 6.0 A PELTIER UNIT
date 05/07/2012 │ page 2 of 3
CPM-2F PERFORMANCE (Th=50°C)
Voltage Input (V)
6A
16.0
5A
4A
3A
8.0
2A
1A
0
6A
Heat Pumped (W)
40.0
5A
4A
30.0
3A
2A
20.0
10.0
1A
0
ΔT=Th−Tc(℃)
MECHANICAL
parameter
conditions/description
min
weight
typ
200
cooling medium
aluminum
heat radiation medum
aluminum
MECHANICAL DRAWING
units: mm
tolerance: ±0.3 mm
55.0 2.165
51.0 2.008
44.5 1.752
COOLING SURFACE
8.5 0.335
VENDOR: JST
PART NO: VHR-2N
27.0 1.063
RADIATING SURFACE
6.0 0.236
6.0 0.236
70.0 2.756
4.3 0.169
(4 PLCS)
32.0 1.260 0.2
(2 PLCS)
385.0 (15.16)
+20.0
-10.0
60.0 2.362
0.2 (2 PLCS)
M4X7 (4 PLCS)
cui.com
max
units
g
For more information, please visit the product page.
CUI Inc │ MODEL: CPM-2F │ DESCRIPTION: 6.0 A PELTIER UNIT
date 05/07/2012 │ page 3 of 3
REVISION HISTORY
rev.
description
date
1.0
initial release
07/09/2008
1.01
applied new template
05/07/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.