cp40

For more information, please visit the product page.
date
05/08/2012
page
1 of 5
SERIES: CP40 │ DESCRIPTION: 4.0 A PELTIER MODULE
FEATURES
•
•
•
•
solid state device
small and lightweight
precise temperature control
quiet operation
RoHS
input
voltage
input
current
max
(V)
max
(A)
CP40136
3.8
4
CP40236
8.6
4
15.4
4
33.4
MODEL
CP40336
Notes:
output
Qmax1
Th=27°C
(W)
output
∆Tmax2
Th=50°C
(W)
Th=27°C
(°C)
Th=50°C
(°C)
8.1
9.0
66
72
18.7
21.8
66
72
37.3
66
72
1. maximum cooling capacity at Imax, Vmax, and ∆T=0°C
2. maximum temperature difference at Imax, Vmax, and Q=0W (maximum parameters are measured in a vacuum)
PART NUMBER KEY
CP40 X 36
Base Number
Thickness
Length/Width:
1 = 15 x 15 mm
2 = 20 x 20 mm
3 = 30 x 30 mm
GENERAL
parameter
conditions/description
min
typ
max
units
internal resistance3
CP40136
CP40236
CP40336
0.72
1.8
3.15
0.80
2.0
3.5
0.88
2.2
3.85
Ω
Ω
Ω
solder melting temperature
connection between termoelectric pairs
assembly compression
hot side plate
MTBF
Notes:
3. measured by AC 4-terminal method at 25°C
For further information and product selection refer to peltier applicaftion notes.pdf
cui.com
138
°C
98.07
10
N/cm2
kgf/cm2
80
°C
200,000
hours
For more information, please visit the product page.
CUI Inc │ SERIES: CP40 │ DESCRIPTION: 4.0 A PELTIER MODULE
date 05/08/2012 │ page 2 of 5
Input Voltage (V)
CP40136 PERFORMANCE (Th=27°C)
3.9 A
4.0
3.12 A
2.34 A
2.0
1.56 A
0.78 A
0
8.0
Heat Pumped (W)
3.9 A
6.0
3.12 A
2.34 A
4.0
1.56 A
2.0
0.78 A
0
ΔT=Th−Tc(℃)
CP40136 PERFORMANCE (Th=50°C)
Input Voltage (V)
3.9 A
4.0
3.12 A
2.34 A
1.56 A
2.0
0.78 A
0
8.0
Heat Pumped (W)
3.9 A
3.12 A
6.0
2.34 A
1.56 A
4.0
0.78 A
2.0
0
ΔT=Th−Tc(℃)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP40 │ DESCRIPTION: 4.0 A PELTIER MODULE
date 05/08/2012 │ page 3 of 5
CP40236 PERFORMANCE (Th=27°C)
Input Voltage (V)
3.9 A
8.0
3.12 A
2.34 A
1.56 A
4.0
0.78 A
Heat Pumped (W)
0
20.0
3.9 A
3.12 A
10.0
2.34 A
1.56 A
0.78 A
0
70
60
50
40
30
20
10
0
ΔT=Th−Tc(℃)
CP40236 PERFORMANCE (Th=50°C)
3.9 A
3.12 A
Input Voltage (V)
8.0
2.34 A
1.56 A
4.0
0.78 A
Heat Pumped (W)
0
20.0
3.9 A
3.12 A
2.34 A
10.0
1.56 A
0.78 A
0
ΔT=Th−Tc(℃)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP40 │ DESCRIPTION: 4.0 A PELTIER MODULE
date 05/08/2012 │ page 4 of 5
Input Voltage (V)
CP40336 PERFORMANCE (Th=27°C)
3.9 A
16.0
3.12 A
2.34 A
8.0
1.56 A
0.78 A
0
30.0
Heat Pumped (W)
3.9 A
3.12 A
20.0
2.34 A
1.56 A
10.0
0.78 A
0
ΔT=Th−Tc(℃)
CP40336 PERFORMANCE (Th=50°C)
Input Voltage (V)
3.9 A
16.0
3.12 A
2.34 A
1.56 A
8.0
0.78 A
0
3.9 A
30.0
Heat Pumped (W)
3.12 A
2.34 A
20.0
1.56 A
10.0
0.78 A
0
ΔT=Th−Tc(℃)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CP40 │ DESCRIPTION: 4.0 A PELTIER MODULE
date 05/08/2012 │ page 5 of 5
MECHANICAL DRAWING
units: mm
MATERIAL
0.80 (TYP)
Cold Side
3.6 0.01
ceramic plate
Al203 (Alumina)
sealer
silicon rubber RTV
lead wire
UL1430 (22AWG)
joint cover
silicon rubber RTV
PLATING
tin
Hot Side
100.0 5.0
7.0 3.0
L
Red (+)
W
COLD SIDE
Black (-)
MODEL
LENGTH x WIDTH (mm)
CP40136
15 x 15 ±0.3
CP40236
20 x 20 ±0.3
CP40336
30 x 30 ±0.3
REVISION HISTORY
rev.
description
date
1.0
initial release
09/03/2009
1.01
applied new template
05/08/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.