SERIES: VYB10W-T │ DESCRIPTION: DC-DC CONVERTER
chassis mount with screw terminal connectors
up to 10 W output
compact size
4:1 input range (9 ~ 36 V, 18 ~ 72 V)
single and dual outputs
1,500 V isolation
short circuit protection
wide temperature operation (-40 ~ 85°C)
efficiency up to 83%
U
•
•
•
•
•
•
•
•
•
ED
FEATURES
input
voltage
output
voltage
range
(Vdc)
(Vdc)
min
(mA)
3.3
VYB10W-Q24-S3-T2
9 ~ 36
VYB10W-Q24-S5-T
9 ~ 36
VYB10W-Q24-S12-T
9 ~ 36
9 ~ 36
9 ~ 36
output
power
ripple1
noise1
efficiency
max
(mA)
max
(W)
max
(mVp-p)
max
(mVp-p)
typ
(%)
240
2,400
8
50
150
76
5
200
2,000
10
50
150
79
12
83
833
10
50
150
81
15
67
666
10
50
150
82
±5
±100
±1,000
10
50
150
80
N
VYB10W-Q24-S15-T
VYB10W-Q24-D5-T
output
current
TI
MODEL
N
RoHS
9 ~ 36
±12
±42
±416
10
50
150
82
9 ~ 36
±15
±33
±333
10
50
150
83
2
VYB10W-Q48-S3-T
18 ~ 72
3.3
240
2,400
8
50
150
77
VYB10W-Q48-S5-T2
18 ~ 72
5
200
2,000
10
50
150
78
VYB10W-Q48-S12-T
VYB10W-Q48-S15-T
VYB10W-Q48-D5-T2
18 ~ 72
12
83
833
10
50
150
82
18 ~ 72
15
67
666
10
50
150
83
18 ~ 72
±5
±100
±1,000
10
50
150
78
18 ~ 72
±12
±42
±416
10
50
150
82
18 ~ 72
±15
±33
±333
10
50
150
83
IS
C
VYB10W-Q48-D12-T
O
VYB10W-Q24-D12-T
VYB10W-Q24-D15-T
VYB10W-Q48-D15-T
Notes:
1. Ripple and noise are measured at 20 MHz BW with 10μF tantalum capacitor and 1μF ceramic capacitor across output
2. PWM mode, others PFM mode
D
PART NUMBER KEY
Base Number
VYB10W - QXX - X XX - T
Input Voltage
Output
S = single output
D = dual output
cui.com
Output Voltage
For more information, please visit the product page.
CUI Inc │ SERIES: VYB10W-T │ DESCRIPTION: DC-DC CONVERTER
date 04/05/2013 │ page 2 of 5
INPUT
conditions/description
operating input voltage
min
typ
max
units
9
18
24
48
36
72
Vdc
Vdc
OUTPUT
parameter
conditions/description
line regulation
measured from low line to high line
min
load regulation
measured from 10% to full load
voltage accuracy
positive, refer to recommended circuit
negative, refer to recommended circuit
switching frequency
100% load, input voltage range
parameter
conditions/description
short circuit protection
continuous, automatic recovery
parameter
conditions/description
max
units
±0.5
%
±0.5
±1
%
±1
±3
±3
±5
%
%
U
min
TI
SAFETY AND COMPLIANCE
N
1. Dual output models unbalanced load: ±5%
PROTECTIONS
typ
±0.2
1
300
temperature coefficient
Notes:
ED
parameter
min
kHz
±0.03
%/°C
typ
max
units
typ
max
units
tested for 1 minute at 1 mA max.
1,500
Vdc
at 500 Vdc
1,000
MΩ
isolation capacitance
input to output, 100 kHz / 1 V
RoHS compliant
yes
MTBF
parameter
operating temperature
storage temperature
storage humidity
hours
min
max
units
see derating curve
-40
100
°C
typ
-55
125
°C
95
%
non-condensing
100% load
40
DERATING CURVES
output power vs. ambient temperaure
100
Load (%)
D
pF
conditions/description
IS
C
temperature rise
1,000
1,000,000
O
ENVIRONMENTAL
N
isolation voltage
isolation resistance
80
60
40
20
-40
-20
0
20
40
60 71 8085
Ambient Temperature (°C)
cui.com
100
120
°C
For more information, please visit the product page.
CUI Inc │ SERIES: VYB10W-T │ DESCRIPTION: DC-DC CONVERTER
date 04/05/2013 │ page 3 of 5
MECHANICAL
conditions/description
dimensions
55.0 x 52.3 x 19.1 (2.17 x 2.06 x 0.75 inch)
min
case material
aluminum
typ
max
units
mm
ED
parameter
weight
50
MECHANICAL DRAWING
units: mm [inch]
tolerance: ± 0.5 [± 0.020] unless otherwise specified
3.51 0.138
(2 PLCS)
0.079 X 0.157
[2.01 X 3.99]
(2 PLCS)
19.05 0.750
N
4.75 0.187
(2 PLCS)
TI
N
U
screw terminals: Degson Electronics terminal block
part number DG301-5.0-04P-12 or equivelant (4 pin,
M2.5 screw) 5.0 mm spacing DIN rail mounting kit
available (part # STK-DIN)
g
7
6
5
4
3
2
1
1.00 0.039
(TYP)
20.32 0.800
0.010 (2 PLCS)
12.19 0.480
33.02 1.300
0.010 (2 PLCS)
5.21 0.205
(2 PLCS)
10.99 0.433
0.010 (2 PLCS)
52.99 2.086
PIN CONNECTIONS
Dual
Pin
S ingle
-Vo
1
0V
D
4.01 0.158
0.010 (TYP)
cui.com
R1.76 0.069
(2 PLCS)
34.93 1.375
0.010
34.01 1.339
0.010
9.16 0.361
0.010
IS
C
8
O
52.32 2.060
54.99 2.165
0V
2
3
4
5
No Pin
+ Vo
No Pin
Case
+ Vo
No Pin
Case
6
No Pin
No Pin
7
Vin
Vin
8
GND
GND
5.31 0.209
(5 PLCS)
M3X4
(5 PLCS)
For more information, please visit the product page.
CUI Inc │ SERIES: VYB10W-T │ DESCRIPTION: DC-DC CONVERTER
date 04/05/2013 │ page 4 of 5
APPLICATION NOTES
Requirement on Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the
minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an
appropriate resistor as extra loading.
2.
Recommended Circuit
The VYB10W series has been tested according to the following recommended testing circuit. This series should be tested under load.
(see Figure 1)
Dual Output
Single Output
Cin
GND
3
Vin
+Vo
DC/DC
2
8
GND
0V
1
3
DC/DC
Cin
Cout
8
7
U
7
Vin
+Vo
Cout
0V
Cout
-Vo
1
N
Figure 1
ED
1.
If you want to further decrease the input/output ripple, you can increase capacitance properly or choose capacitors with low ESR. If
the capacitance is too big, a startup problem might arise. The maximum allowable capacitance to ensure safe and reliable operation is
listed in Table 1.
Table 1
Cout
(μF)
Dual Vout
(Vdc)
Cout
(μF)
3.3
2,200
--
--
5
1,000
±5
680
12
470
±12
330
15
330
±15
220
Ip
Input Voltage
Range
Input Voltage (V)
Figure 2
D
IS
C
O
General: Ip ≤1.6*Iin-max
N
Input Current
When using an unstable power source, please ensure the output voltage and ripple voltage do not excced indexes of the converter.
The preceding power source must be able to provide for converter sufficient starting current Ip.
Input Current(A)
3.
Cin: 10 ~ 47 μF
Cout: 10 μF / 100 mA
Single Vout
(Vdc)
TI
General:
Notes:
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
3. No parallel connection
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VYB10W-T │ DESCRIPTION: DC-DC CONVERTER
date 04/05/2013 │ page 5 of 5
REVISION HISTORY
description
date
08/08/2011
1.0
initial release
1.01
V-Infinity branding removed
1.02
removed on/off control option, updated spec
ED
rev.
08/29/2012
04/05/2013
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.