For more information, please visit the product page. date 01/13/2014 page 1 of 5 SERIES: VASD1-DIP │ DESCRIPTION: DC-DC CONVERTER 1 W isolated output industry standard 14 pin DIP package dual unregulated outputs 1,000 V isolation short circuit protection UL safety approvals wide temperature (-40~85°C) efficiency up to 80% U • • • • • • • • ED FEATURES MODEL input voltage typ (Vdc) range (Vdc) (Vdc) 5 4.5~5.5 ±5 output current output power ripple and noise1 efficiency min (mA) max (mA) max (W) max (mVp-p) typ (%) ±10 ±100 1 75 72 TI VASD1-S5-D5-DIP output voltage N RoHS VASD1-S5-D9-DIP 5 4.5~5.5 ±9 ±6 ±56 1 75 77 VASD1-S5-D12-DIP 5 4.5~5.5 ±12 ±5 ±42 1 75 78 5 4.5~5.5 ±15 ±4 ±33 1 75 80 VASD1-S12-D5-DIP 12 10.8~13.2 ±5 ±10 ±100 1 75 72 VASD1-S12-D9-DIP 12 10.8~13.2 ±9 ±6 ±56 1 75 78 VASD1-S12-D12-DIP 12 10.8~13.2 ±12 ±5 ±42 1 75 79 VASD1-S12-D15-DIP 12 10.8~13.2 ±15 ±4 ±33 1 75 78 VASD1-S15-D5-DIP 15 13.5~16.5 ±5 ±10 ±100 1 75 72 24 21.6~26.4 ±5 ±10 ±100 1 150 73 24 21.6~26.4 ±9 ±6 ±56 1 150 79 24 21.6~26.4 ±12 ±5 ±42 1 150 80 24 21.6~26.4 ±15 ±4 ±33 1 150 80 VASD1-S24-D9-DIP VASD1-S24-D12-DIP IS C VASD1-S24-D15-DIP O VASD1-S24-D5-DIP N VASD1-S5-D15-DIP Notes: 1. ripple and noise are measured at 20 MHz BW D PART NUMBER KEY Base Number VASD1 - SXX - DXX -DIP Input Voltage Output Voltage cui.com Packaging Style For more information, please visit the product page. CUI Inc │ SERIES: VASD1-DIP │ DESCRIPTION: DC-DC CONVERTER date 01/13/2014 │ page 2 of 5 INPUT conditions/description min typ max units operating input voltage 5 V model 12 V model 15 V model 24 V model 4.5 10.8 13.5 21.6 5 12 15 24 5.5 13.2 16.5 26.4 Vdc Vdc Vdc Vdc min typ max units 1.2 % 15 15 15 15 % % % % OUTPUT load regulation measured from 10% load to full load 5 V model 9 V model 12 V model 15 V model voltage accuracy see derating curves switching frequency 100% load, input voltage range temperature coefficient PROTECTIONS conditions/description short circuit protection SAFETY AND COMPLIANCE conditions/description isolation voltage for 1 minute at 1 mA max. isolation resistance at 500 Vdc safety approvals UL 60950-1 (E222736) MTBF 100 kHz ±0.03 %/°C typ typ max units 1 s max units 1,000 Vdc 1,000 MΩ 3,500,000 hours full load at 85°C, 4 hours at no load and 4 hours at full load O RoHS compliant min N parameter burn-in min TI parameter 10.5 8.3 6.8 6.3 U conditions/description for Vin change of 1% N parameter line regulation ED parameter yes ENVIRONMENTAL conditions/description min IS C parameter typ max units operating temperature -40 85 °C storage temperature -55 125 °C storage humidity non-condensing temperature rise at full load lead temperature 1.5 mm from case for 10 seconds D 15 cui.com 95 % 25 °C 300 °C For more information, please visit the product page. CUI Inc │ SERIES: VASD1-DIP │ DESCRIPTION: DC-DC CONVERTER date 01/13/2014 │ page 3 of 5 DERATING CURVES 2. output voltage vs. output current ED 1. output power vs. ambient temperature +10% Output Voltate (%) Load (%) 100 80 60 40 -40 -20 0 20 40 60 85 +2.5% Voltage -2.5% -7.5% U 20 +5% Nominal 105 120 50% 10% MECHANICAL parameter conditions/description dimensions 20.00 x 7.00 x 10.00 (0.787 x 0.276 x 0.394 inch) case material plastic (UL94-V0) min TI weight MECHANICAL DRAWING typ O IS C 1 1 2.1 11 9 8 7 PIN CONNECTIONS 7 9 8 D 11 14 cui.com PIN FUNCTION 1 GND 7 ND 8 0V 9 +Vo 11 -Vo 14 Vin max units mm N units: mm [inches] tolerance: ±0.25 [±0.010] pin section tolerance: ±0.10 mm [±0.004] 14 100% Output Current (%) N Ambient Temperature (°C) g For more information, please visit the product page. CUI Inc │ SERIES: VASD1-DIP │ DESCRIPTION: DC-DC CONVERTER date 01/13/2014 │ page 4 of 5 APPLICATION NOTES ED 1. Requirement on Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading. 2. Overload Protection Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. TI N U 3. Filtering In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid mutual interference (Figure 1). L L +Vo Vin Cout Figure 1 0V Cin DC DC L Cout GND -Vo 4. Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure 2). R EG N Vi n Figure 2 GND REG DC DC +Vout 0V REG -Vout O 5. External Capacitor Table It is not recommended to connect any external capacitor in the application field with less than 0.5 W output. Vin (Vdc) Vout (Vdc) Cout (µF) 5 4.7 ±5 4.7 12 2.2 ±9 2.2 15 2.2 ±12 1 24 1 ±15 0.47 D IS C Table 1 Cin (µF) Note: All specifications measured at 25°C, humidity <75%, nominal input voltage, and full load unless otherwise noted. cui.com For more information, please visit the product page. CUI Inc │ SERIES: VASD1-DIP │ DESCRIPTION: DC-DC CONVERTER date 01/13/2014 │ page 5 of 5 REVISION HISTORY description date 09/01/2009 1.0 initial release 1.01 new template applied 1.02 V-Infinity branding removed 1.03 updated spec ED rev. 03/09/2012 09/04/2012 01/13/2014 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.