VESD1-SIP Datasheet - DC

For more information, please visit the product page.
date
03/08/2013
page
1 of 5
SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
1 W isolated output
industry standard 7 pin SIP package
dual unregulated outputs
3,000 V isolation
short circuit protection
UL safety approvals (some models)
wide temperature (-40~85°C)
efficiency up to 81%
N
U
•
•
•
•
•
•
•
•
ED
FEATURES
MODEL
input
voltage
typ
(Vdc)
VESD1-S5-D9-SIP
VESD1-S5-D12-SIP
VESD1-S5-D15-SIP
VESD1-S12-D5-SIP
5
output
current
efficiency
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
typ
(%)
4.5 ~ 5.5
±5
±10
±100
72
UL 60950
YES
4.5 ~ 5.5
±9
±6
±56
75
YES
4.5 ~ 5.5
±12
±5
±42
78
YES
5
4.5 ~ 5.5
±15
±4
±33
79
YES
12
10.8 ~ 13.2
±5
±10
±100
74
YES
5
12
10.8 ~ 13.2
±9
±6
±56
76
YES
12
10.8 ~ 13.2
±12
±5
±42
79
YES
O
VESD1-S12-D9-SIP
5
output
voltage
N
VESD1-S5-D5-SIP
TI
RoHS
±15
15
13.5 ~ 16.5
±9
±6
±56
75
NO
VESD1-S15-D12-SIP
15
13.5 ~ 16.5
±12
±5
±42
79
NO
VESD1-S15-D15-SIP
15
13.5 ~ 16.5
±15
±4
±33
79
NO
VESD1-S24-D5-SIP
24
21.6 ~ 26.4
±5
±10
±100
74
YES
VESD1-S12-D12-SIP
VESD1-S12-D15-SIP
VESD1-S15-D5-SIP
10.8 ~ 13.2
±4
±33
80
YES
13.5 ~ 16.5
±5
±10
±100
74
NO
IS
C
VESD1-S15-D9-SIP
12
15
24
21.6 ~ 26.4
±9
±6
±56
76
YES
24
21.6 ~ 26.4
±12
±5
±42
80
YES
VESD1-S24-D15-SIP
24
21.6 ~ 26.4
±15
±4
±33
81
YES
D
VESD1-S24-D9-SIP
VESD1-S24-D12-SIP
VESD1-S XX -D XX -SIP
Base Number
Input Voltage
cui.com
Output Voltage
For more information, please visit the product page.
CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 03/08/2013 │ page 2 of 5
INPUT
conditions/description
min
typ
max
units
operating input voltage
5 V model
12 V model
15 V model
24 V model
4.5
10.8
13.5
21.6
5
12
15
24
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
min
typ
max
units
1.2
%
15
%
150
mVp-p
OUTPUT
conditions/description
for Vin change of 1%
load regulation
measured from 10% to full load
voltage accuracy
see tolerance envelope graph
output ripple
20 MHz bandwidth
switching frequency
100% load, input voltage range
10
U
parameter
line regulation
100
100
parameter
conditions/description
SAFETY AND COMPLIANCE
conditions/description
isolation voltage
tested for 1 minute
safety approvals
UL 60950
insulation resistance
at 500 Vdc
RoHS compliant
yes
parameter
O
ENVIRONMENTAL
min
N
parameter
MTBF
min
TI
short circuit protection
N
temperature coefficient
PROTECTIONS
ED
parameter
conditions/description
typ
typ
kHz
±0.03
%/°C
max
units
1
s
max
units
3,000
Vdc
1,000
MΩ
3,500,000
hours
min
typ
max
units
case operating temperature
-40
85
°C
storage temperature
-55
125
°C
95
%
25
°C
300
°C
non-condensing
IS
C
storage humidity
100% load
lead temperature
1.5 mm from the case for 10 seconds
15
D
temperature rise
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 03/08/2013 │ page 3 of 5
DERATING CURVES
ED
Load (%)
100
80
60
40
20
-40
-20
0
20
40
60
85
100
120
U
Ambient Temperature (°C)
MECHANICAL
conditions/description
19.60 x 10.00 x 6.0 (0.77 x 0.39 x 0.24 inch)
case material
plastic UL94-V0
MECHANICAL DRAWING
N
Units: mm
All pins on a 2.54mm pitch
All pin diameters are 0.50mm
Side View
D
2.00
2.54
O
1 2
2.1
5 6 7
5 6 7
IS
C
1 2
1 2
5 6 7
2.54
PIN CONNECTIONS
1
6.00
15.24
Bottom View
cui.com
units
mm
1.00 + 0.15/-0
4.10
1.25
max
Recommended Footprint
19.60
10.00
typ
TI
weight
min
N
parameter
dimensions
+Vin
2
-Vin
5
-Vout
6
COM
7
+Vout
g
For more information, please visit the product page.
CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 03/08/2013 │ page 4 of 5
APPLICATION NOTES
ED
1. Requirement on Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the
minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an
appropriate resistor as extra loading.
2. Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The
simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
N
Figure 1
L
L
+Vin
U
3. Filtering
In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to
reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be
connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also
be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid
mutual interference (Figure 1).
DC DC
C
L
COM
C
-Vout
TI
-Vin
+Vout
C
<Figure 1>
4. Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (Figure 2).
REG
+Vout
N
+Vin
Figure 2
-Vin
O
+Vin
DC DC
COM
-Vout
REG
DC DC
-Vin
+Vout
COM
REG
-Vout
IS
C
5. External Capacitor Table
It is not recommended to connect any external capacitor in the application field with less than 0.5 W output.
Cout
(µF)
Vout
(Vdc)
Cout
(µF)
5
4.7
5
4.7
12
2.2
9
2.2
24
1
12
1
--
--
15
0.47
D
Table 1
Vin
(Vdc)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 03/08/2013 │ page 5 of 5
REVISION HISTORY
description
date
12/09/2010
1.0
initial release
1.01
template update
1.02
V-Infinity branding removed
1.03
updated spec
ED
rev.
02/02/2012
09/06/2012
03/08/2013
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.