MODEL: CLS0231MP-1 DESCRIPTION: SPEAKER

For more information, please visit the product page.
date
09/30/2013
page
1 of 3
MODEL: CLS0231MP-1 │ DESCRIPTION: SPEAKER
RoHS
SPECIFICATIONS
parameter
conditions/description
min
nominal size
typ
max
23
units
mm
impedance
at 1.5 kHz, 0.9 V
6.8
8
9.2
Ω
resonant frequency
at 0.9 V
384
480
576
Hz
72
sound pressure level
0.1 W, 50 cm ave., at 0.6, 0.8, 1, 1.2 kHz
69
response
10 dB max.
Fo
input power
operation
0.1
75
dB
20,000
Hz
0.2
W
must be normal at program source
0.1
buzz, rattle, etc.
must be normal at sine wave
0.9
magnet
size: Ø9.5 x 1.5
load test
5 hours of white noise at
heat test
20 ~ 50% RH for 5 hours
63
65
67
°C
humidity test
90 ~ 95% RH for 5 hours
38
40
42
°C
RoHS
yes
0.1
conditions/description
potentiometer range
50 dB
rectifier
RMS
lower limit frequency
20 Hz
wr. speed
100 mm/sec
zero level
50 dB
Vdc
mm
FREQUENCY RESPONSE CURVE
parameter
W
cui.com
W
For more information, please visit the product page.
CUI Inc │ MODEL: CLS0231MP-1 │ DESCRIPTION: SPEAKER
date 09/30/2013 │ page 2 of 3
MECHANICAL DRAWING
units: mm
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: CLS0231MP-1 │ DESCRIPTION: SPEAKER
date 09/30/2013 │ page 3 of 3
REVISION HISTORY
rev.
description
date
1.0
initial release
07/03/2007
1.01
dimension updates
09/29/2009
1.02
dimension updates
04/13/2010
applied new spec template, corrected sound pressure level
09/30/2013
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.